GREE G207MN Series Window Type Air Conditioner Instruction Manual
- October 30, 2023
- Gree
Table of Contents
Window type Air Conditioner
OPERATING INSTRUCTIONS
Models:
G207MN G207RN
G209MN G209RN
G212MN G212RN
G218MN G218RN
G224MN G224RN
G207MN Series Window Type Air Conditioner
Thank you for choosing air conditioner. Our design is based on the best
efficiency and the lowest noise operation and it can keep the room
comfortable. Please read this operating manual carefully before operating the
unit and keep it for consultation.
NOTICE:
This appliance is not intended for use by persons (including children) with
reduced physical, sensory or mental capabilities, or lack of experience and
knowledge, unless they have been given supervision or instruction concerning
use of the appliance by a person responsible for their safety.
Children should be supervised to ensure that they do not play with the
appliance.
The appliance shall be installed in accordance with local regulations
If the supply cord is damaged, it must be replaced by the manufacturer, its
service agent or similarly qualified persons in order to avoid a hazard.
Please read this operating manual carefully before operating the unit.
The figures in this manual may be different with the material objects, please
refer to the material objects for reference.
Explanation of Symbols
DANGER Indicates a hazardous situation that, if not avoided, will result
in death or serious injury.
WARNING Indicates a hazardous situation that, if not avoided, could
result in death or serious injury.
CAUTION Indicates a hazardous situation that, if not avoided, may result
in minor or moderate injury.
NOTICE Indicates important but not hazard-related information, used to
indicate risk of property damage.
**** Indicates a hazard that would be assigned a signal word WARNING or
CAUTION.
Structure mechanism and Installation
Precautions
Warning
Children shall not play with the appliance.
Cleaning and user maintenance shall not be made by children without
supervision.
The air conditioner should be installed in accordance with local regulation.
Air Conditioner should be properly grounded. Incorrect grounding may cause
electric shock.
- This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved.
- Do not connect air conditioner to multi-purpose socket. Other hazard.
- Do install the air switch. If not, it may cause malfunction. is, it may cause fire
- Do not spill water on the remote controller, otherwise the remote controller may be broken.
- Do not spray water on air conditioner. It may cause electric shock or malfunction.
- Do not extend fingers or objects into air inlet or air outlet. It may cause personal injury or damage.
- Do not step on air conditioner, or put heavy objects. It may cause damage or personal injury.
- Do not block air outlet or air inlet. It may cause malfunction.
- Do disconnect power supply when cleaning air conditioner. Otherwise, it may cause electric shock.
- Do not repair air conditioner by yourself. It may cause electric shock or damage.
- Please contact qualified service agent when you need to repair air conditioner.
- Maintenance must be performed by qualified professionals. Otherwise, it may cause injury or damage.
- The appliance is not to be used by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction.
- Children being supervised not to play with the appliance.
Please install the devices for short-circuit protection and electrical leakage
protection when installing the air conditioner.
According to the local safety regulations, use qualified power supply circuit
and circuit break.
Working temperature range
※ Operating Temperature Range
| Indoor side DB/WB(°C)| Outdoor side DB/WB(°C)
Maximum cooling| 32/23| 43/-
Maximum heating| 27/-| 24/18
The operating temperature range (outdoor temperature) for cooling only unit is
18°C~ 43°C; for heat pump unit is -7°C~ 43°C.
Function
Introduction
Window type room air conditioners can regulate the room temperature and dry
the room. It is convenient for your work, study and life. It can be widely
used in residence, shop, hotel, office, library and laboratory, and so on.
Cooling in summer
In hot summer, Air conditioner can cool down the room air by transferring heat
out.
Dehumidifying in rainy or humid season
Without reducing the room temp., air conditioner can dehumidify and make the
room air dry and comfortable.
Heating in winter (Only for heat unit)
In cold winter, Air conditioner can heat up room air.
Exchange fresh air
Open ventilation lever to keep the fresh air in the room.
Operating Condition
Please operate air conditioner in the correct conditions as following.
COOL mode operation
Outdoor temperature should be in range of 18 °C to 43 °C , otherwise it is
possible for air conditioner to breakdown.
Room humidity should be lower than 90%. Otherwise, it is possible for air
conditioner to dew at air conditioner surface and even drop water after
running for so much time. But this is normal.
DRY mode operation
Outdoor temperature should be in range of 18 °C to 43 , otherwise it is
possible for air conditioner to breakdown.
Power requirement
The electric components will be damaged when the voltage is too high.
If the voltage is too low, the compressor will vibrate violently to damage the
refrigerant system and easily cause the compressor and electric components not
work.
The ground must be connected.
Special socket must be used. Furthermore, the socket and wiring must conform
to the wiring regulations. And the earthing method must be reliable.
In fixed circuit, there must be electricity leakage protection switch of
enough power capacity and air switch with enough space.
Earth wire To ensure the reliable earthing, please do not connect earth wire to the following places:
Installation
Installation precaution:
Window type conditioner is so valuable and the improper installation of it
will cause a lot of damage! Please associate the professional technician to
install the unit and don’t install it by yourself. Otherwise, we are not
responsible for the damage due to the improper installation.
Location:
- The condensation water must be drained away conveniently.
- Install air conditioner unit far away from TV set or radio etc. to avoid disturbing video or voice.
- In salt and coastal area or place where is near thermal springs and polluted by sulphurous gas, or other special areas, please contact the seller before use.
- Avoid a place where is possible for inflammable gas to leak out.
- Avoid other heat sources or direct sun light.
- Avoid a place where is easy for children to touch.
- Don’t use the unit in the immediate surroundings of a laundry, a bath, a shower or a swimming pool.
- For window type air conditioner with remote control, install in a location where is strong electromagnetic disturbance, you should contact the seller in advance to avoid the malfunction in use.
How to install:
Choose a location where there are no any obstacle surrounding the unit, and
the plug is accessible.
Prepare the installation hole slightly bigger than unit size.
Choose the installation space according to the following diagram.
Installation procedure:
-
Remove the sticker from the front panel.
-
Put the unit into the installation hole.
• When installing the unit, it should be slanted down to the back to avoid the enlargement of noise or vibration. (Slant between 6-10mm.) (Shown at right figure.)
• The installation place should be strong enough to avoid the enlargement of noise or vibration. -
Fill up sews in the cabinet with sponge or foam.
Installation assistance:
-
Use iron support
The installation hole should be strong enough to support the air conditioner. If it cannot, iron support has to be used outdoors. Iron support should be fixed on the building (Shown at right figure.) -
Use sunshade board
Air conditioner should avoid anything to be dropped into it and avoid direct sunshine. If there is no cover on it, you should contact the seller for installing the sunshade board. When installing the sunshade board, don’t let it block the air inlet at the side grille.
Drain water for one style:
To get the maximum cooling efficiency, the air conditioner is designed to
splash the condensate on the condenser coil.
If the splashing sound annoys you, you can provide an outside drain by using
the following procedure, which may cause a small loss of performance.
- There is a drainage outlet at the back of the unit.
- Remove cover from the drainage outlet, and then connect drainage joint to it with screw.
- Connect the drain hose to the outlet.
Note:
Drain hose or tubing can be purchased locally to satisfy your particular
needs.
Drain water for another style:
To get the maximum cooling efficiency, the air conditioner is designed to
splash the condensation water on the condenser coil.
To the cooling only unit, If the splashing sound annoys you, you can provide
an outside drain by using the follo -wing procedure, which may cause a small
loss of performance.
- Slide out the chassis from the cabinet.
- Remove the rubber plug from the body base plate.
- Install the drain pan to the corner of the cabinet with 2 screws.
- Connect the drain hose to the outlet on the drain pan bottom.
- Slide the chassis into its original place in the cabinet.
Note:
Drain pan and drain hose must be installed before using reverse cycle models.
Drain hose or tubing can be purchased locally to satisfy your particular
needs.
Notes for installation
Remove
Before removing air conditioner to the other place, you should contact the
seller firstly.
Then it must be done under the direction of the professional technician. In
addition, the charge of this must be paid.
Noise
- Install in a location where is firm enough to avoid the enlargement of noise and vibration.
- Don’t put anything in front of the outlet of the unit to avoid increasing noise.
- Be sure that hot air or noise will not inconvenience neighbors.
- Please contact the seller as soon as there is strange noise during operation.
- Please use the safety support.
Electric wiring
- Must connect with ground reliably.
- The exclusive circuit must be used. But removable socket can’t be used because poor contact of it can cause over heat or fire.
- Don’t pull the power cord strongly.
- In fixed circuit, there must be electricity leakage protection switch and leakage current is less than 30mA.
- Connecting method between air conditioners and power cord and interconnecting method of each individual element with one another should accord with wiring diagram on the unit.
- The air conditioner should be installed in accordance with local regulation.
- An all-pole disconnection switch having a contact separation of at least 3mm in all poles should be connected in fixed wiring
- Air switch (thermal-magnetic breaker) should be installed in the circuit
- If the supply cord is damaged, it must be replaced by the manufacturer or your dealer or a qualified person to avoid a hazard.
- All the electrical work must be done according to the local wiring regulations.
- Shall be installed in the circuit of miniature circuit switch and it has a capacity of 10A (G207MN/ RN , G209MN/RN, G212MN/RN),16A (G218MN/RN ) or 25 A(G224MN/RN);
- Fixed line shall be greater than 1.5mm (G207MN/RN, G209MN/RN, G212MN/RN) and 2.5mm (G218MN/RN,G224MN/RN);
Operation procedure
Part identification
Air direction adjustment
Vertical airflow direction vane
(Airflow direction adjustment up and down).
The vertical airflow direction vane is controlled by positioning the vane to
discharge the air upwards, downwards or straight out.
Main switch operation procedure
-
Main Control Knob
Set to Low Cool, Med Cool or High Cool as desired (FAN setting operates the fan only.)
CAUTION: If the main control knob is turned off of changed to a fan setting from a cooling operation setting.
WAIT at least 3 minutes before resetting to cooling operation. -
Thermostat control Knob
Set the thermostat control knob to your desired setting (Usually 6-7 is recommended), If the room temperature is not as desired after a reasonable period, turn the thermostat. When the thermostat control knob is set to 10, moisture may freeze onto evaporator fins and the thermostat control knob counter clockwise. This will quickly defrost the evaporator fins so that normal cooling can be resumed. -
Air Swing Switch
(Airflow direction adjustment Side-to Side)
To obtain a fix airflow direction, set the air swing switch to “ON” for the vanes to swing from side to side until the desired flow direction is reached, then switch it to “OFF”. For continuous side-to-side air circulation, set the air swing switch to “ON”.
Remote control operation procedure
Buttons on remote controller
- ON/OFF button
- MODE button
- +/- button
- FAN button
- SWING button
- SLEEP button
- TIMER button
Introduction for icons on display screen
Introduction for buttons on remote controller
Note:
- This is a general use remote controller, it could be used for the air conditioners with multifunction; For some function, which the model doesn’t have, if press the corresponding button on the remote controller that the unit will keep the original running status.
- When power is connected (stand by condition), you can operate the air conditioner through the remote controller.
- When unit is on, each time you press the button on remote controller, the sending signal icon ” ” on the display of remote controller will blink once. If the air con- ditioner gives out a beep sound, it means the signal has been sent.
- When unit is off, set temperature will be displayed on the remote controller (If the light of the unit display is turned on, the corresponding icon will be displayed); When unit is on, it will display the icon of the on-going function.
-
ON/OFF button
Press this button to turn unit on/off. -
MODE button
Pressing this button once can select your required mode circularly as below (the corresponding icon “ ” will be lit up after the mode is selected):● When selecting auto mode, air conditioner will operate automatically according to ambient temperature. Set temperature can’t be adjusted and won’t be displayed either. Press FAN button to adjust fan speed.
● When selecting cool mode, air conditioner will operate under cool mode. Then press + or – button to adjust set temperature. Press FAN button to adjust fan speed.
● When selecting dry mode, air conditioner will operate at low fan speed under dry mode. In dry mode, fan speed can’t be adjusted.
● When selecting fan mode, air conditioner will operate in fan mode only. Then press FAN button to adjust fan speed.
● When selecting heat mode, air conditioner will operate under heat mode. Then press + or – button to adjust set temperature. Press FAN button to adjust fan speed. (Cooling only unit can’t receive heating mode signal. If set HEAT mode by remote controller, press ON/OFF button can’t turn on the air conditioner.) -
+ / – button
● Pressing + or – button once will increase or decrease set temperature by 1°F(°C). Hold + or – button for 2s, set temperature on remote controller will change quickly. Release the button after your required set temperature is reached.
● When setting Timer On or Timer Off, press + or – button to adjust the time. (See TIMER Button for setting details)
Introduction for buttons on remote controller
-
FAN button
Pressing this button can select fan speed circularly as: AUTO, SPEED 1 ( ), SPEED 2 ( ) , SPEED 3 ( ), SPEED 4 ( ) (unavailable in this air conditioner.
Speed 4 is the same with speed 3.). Note:
● Under Auto speed, air conditioner will select proper fan speed automatically according to ambient temperature.
● Fan speed can’t be adjusted under Dry mode. -
SWING button
Press this button to turn on left & right air swing. -
SLEEP button
Under Cool, Heat mode, press this button to turn on Sleep function. Press this button to cancel Sleep function. Under Fan, Dry and Auto mode, this function is unavailable. -
TIMER button
● When unit is on, press this button to set Timer Off. T-OFF and H icon will be blinking. Within 5s, press + or – button to adjust the time for Timer Off. Pressing + or – button once will increase or decrease the time by 0.5h. Hold + or – button for 2s, time will change quickly. Release the button after your required set time is reached. Then press TIMER button to confirm it. T-OFF and H icon will stop blinking.
● When unit is off, press this button to set Timer On. T-ON and H icon will be blinking. Within 5s, press + or – button to adjust the time for Timer On. Pressing + or – button once will increase or decrease the time by 0.5h. Hold + or – button for 2s, time will change quickly. Release the button after your required set time is reached. Then press TIMER button to confirm it. T-ON and H icon will stop blinking.
● Cancel Timer On/Off: If Timer function is set up, press TIMER button once to review the remaining time. Within 5s, press TIMER button again to cancel this function.
Introduction for buttons on remote controller
Note:
- Range of time setting is: 0.5~24h.
- The interval between two motions can’t exceed 5s, otherwise the remote con trolled will exit setting status.
Function introduction for combination buttons
Child lock function
Press “+” and “-” buttons simultaneously can turn on or turn off child lock
function.
When child lock function is started up, LOCK indicator on remote controller is
ON.
If you operate the remote controller, remote controller won’t send signal.
Temperature display switchover function
Under OFF status, press “-” button and “MODE” button simultaneously can switch
between °C and °F.
Operation guide
- After putting through the power, press “ON/OFF” button on remote controller to turn on the air conditioner.
- Press “MODE” button to select your required mode: AUTO, COOL, DRY, FAN, HEAT(Only Applicable for Model with Heating Function).
- Press “+” or “-” button to set your required temperature. (Temperature can’t be adjusted under auto mode).
- Press “FAN” button to set your required fan speed: auto, low, medium and high speed.
Replacement of batteries in remote controller
- Press the mark “ ” on back cover of batteries box cover for remote controller with fingers as shown in the fig, and then remove the batteries box cover along the arrow direction.
- Replace with two (AAA 1.5V) dry batteries. Make sure positions for “+” pole and “-” pole are correct.
- Reinstall batteries box cover.
NOTICE
- The distance between signal sender and receiving window should be no more than 8m, and there should be no obstacles between them.
- As the signal will be interfered in the room with electronic fluorescent lamp, conversion fluorescent lamp or wireless phone, please get closer to the air conditioner when using the remote controller.
- Replace new batteries of the same model when replacement is required.
- When you don’t use remote controller for a long time, please take out the batteries.
Remote control panel
Note:
If wireless remote controller is lost, open the surface panel and operate
manually.
-
ON/OFF BUTTON
Operation starts when pressing this button, and stops when pressing this button again. -
SWING BUTTON
Activate the automatic air swing function. -
FAN BUTTON
Select the fan speed HIGH, MID, LOW and AUTO in sequence. -
TIME/TEMP BUTTON
Press the keypad to increase the set (operating) temperature of the unit. and Press the keypad to decrease the set (operating) temperature of the unit.
The temperature setting range is from 16~30°C.Press the keypad also to increase the selected time in 0.5 hour increments, and Press the keypad to to decrease the selected time in 0.5 hour decrements, The time setting range is from 0~10 hours. Press the keypad also to increase the selected time in 1 hour increments, and Press the keypad to decrease the selected time in 1 hour decrements, The time setting range is from 10~24 hours. -
SIGNAL RECEIVER
-
M ODE BUTTON
Select the operation mode AUTO,COOL,FAN, DRY. -
FILTER BUTTON
This feature is a reminder to clean the Air Filter (See Care and Cleaning) for more efficient operation and cooling. The LED (light) will illuminate after 250 hours of operation. To reset after cleaning the filter, press the “Check Filter” button and the light will go off.
VENTILATION LEVER
Ventilation Lever
When the slider at the: | When the slider at the: |
---|---|
-“OPEN” position, the ventilation door opens to allow air, smoke or odors to
be expelled from the room.| -“CLOSE” position, the ventilation door is closed
and the air will be circulated
inside the room and conditioned.
Operation Tips
Operation for comfort and economy
Do not overcool the room temperature. This is not good for health and wastes
electricity.| Keep blind or curtains closed.
Do not let sunshine enter the room directly when the air condition is in
operation.| Keep the room temperature Adjust the vertical consistent.
and horizontal airflow direction to ensure temperature consisted -nt in the
room. Air-inlet cannot discharge the air flow.
---|---|---
Make sure the doors and win- room dows are tightly closed. Avoid opening doors
and windows as much as possible to keep air conditioning in the room.| Clean
the air filter regularly. Blockages in the air filter reduce effects. Clean
the air filter at least once every two weeks.| Ventilate the room
occasionally. Since windows are kept closed, it is a good idea to open them
and ventilate the room now and then. When starting the unit, curtains or
windows should be closed to prevent the heat/cool leakage.
Care and maintenance
Caution
Operations for safety and health
- The plug must be accessible after the appliance is positioned.
- Do not use this appliance in the laundry.
- If the power cord is damaged, it must be replaced by the manufacturer or its service agent against any hazard.
● Do not pull out the power cord.
● Damage to the cord may result in serious electric shocks.| ● Do not use
the air conditioner for other purposes except for cooling the room.
● Do not use the air conditioner for other purposes such as drying clothes,
preserving foods, or cultivating
vegetables.| ● Do not block the air intake and outlet vents This causes
lowered performance and irregular operation.
● Do not insert sticks or other objects into these vents as it is dangerous
to touch the electric components and the fan.
---|---|---
Select the most appropriate temperature.
Pay attention to adjust the temperature to suit the
conditions.
Rooms occupied by infants, elders or the patient should be kept at an
appropriate temperature.| Do not use heating apparatuses nearby. The air
conditioner
plastic parts will melt if exposed to excessive heat environment.| Avoid
exposing the body directly to a continuous unidirectional air flow for long
periods.
This is not recommended for health reason.
Always wait at least 3 minutes before switching the air conditioner on again after you have switched it off during cooling or heating.
Care and maintenance
Always turn off the air conditioner and cut off the main power supply for
secure before cleaning.
Cleaning unit
-
Cut off power supply before cleaning.
-
Use soft cloth when cleaning cabinet.
If the cabinet is very dirty, dip cloth into warm water below 40 °C dry the cloth and then rub off the dirt. -
Don’t use gas, benzene, solvent, wash, chemical solvent, etc. for cleaning. 4. Do not splash water directly into the unit, in which there are microcomputer and circuit plate, they must not be drenched with water.
* Check earth wire
Air filter
The air filter behind the intake grille should be washed at least once every
two weeks or as often as it needs cleaning.
How to clean the air filter:
- To remove the air intake grille, grasp the tab on the filter and pull to take out.
- Vacuum the filter on the dusty side to remove dust.
- Wash the filter, cleaner side up under gently flowing water to wash out accumulated dust and lint.
- If the filter is very dirty, use a mild household detergent in the wash water.
Let the filter dry thoroughly before reinstalling it.
If necessary, please ask the professional personnel to clean it.
- Check if air inlet and outlet of the unit are blocked or not.
Trouble shooting guide
Please check the following items before asking for repair,it saves your time
and money.
Fault phenomenon | Trouble-shooting |
---|---|
Air conditioner can not operate at all. | * Is there a power failure? |
Is the plug out?
Is power fuse or switch off ?
Whether the voltage is too high(242V) or too low(198V).
Cool or heat efficiency is not good.| Is air inlet or outlet locking?
Is there any other heat/cool source in room?
Are air filters dirty very much?
* Is indoor fan speed set at LOW?
- Maybe the room is too hot/cool when the unit is started.
Foggy air flows out.| At COOL mode operation, sometimes there is foggy air flowing out from the unit, this is because the room humid air has been cooling rapidly.
The unit is normal while the indoor outlet is sending out some odor, because the inlet air may be mixed with the smell of furniture and smoke.
The air conditioner opera tion is noisy.| For a noise that sounds like water flowing:
This is the sound of freon flowing inside the air con- ditioner unit.
For a noise that sounds like a shower:
This is the sound of the dehumidifying water being processed inside the air conditioner unit.
It seems that condensation is leaking from air conditioner.| Condensation occurs when the airflow from the air conditioner cools the warm room air.
Air conditioner cannot operate for about 3 minutes when restart.| This is used to protect the mechanism.
* Wait about three minutes and operation will begin.
Immediately stop all operations and plug out, please contact your dealer in the following situations.
- Operation starts or stops abnormally;
- Power fuse or switch often breaks;
- Carelessly splash water or something into air conditioner;
- Electrical lines are much hot or lines cover breaks;
- Other strange situations.
After service
- If your air conditioner has the questions of quality or anything else, please contact the service center.
MODEL No .:…………………………..
SERIAL No .:………………………….
DEALER .:………………………………………….
DATE OF PURCHASE .:……………………..
INVOICE No .:………………………………..
The product specifications may be changed without prior notice. Please contact
customer service for details if necessary.
If there is any inconsistency or ambiguity between the English version and the
Chinese version, the English version shall prevail.
Tool Box Customer Service Centre
4/F, DCH Building, 20 Kai Cheung Road, Kowloon Bay, Hong Kong
Customer Service Hotline :
(852) 8210 8210 Service
E-mail : 8210service@gilman-group.com
Please register now at
www.toolbox.hk
Website www.gilman-group.com
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>