Dimplex LI 1422C Air to Water Heat Pump Instruction Manual
- June 12, 2024
- Dimplex
Table of Contents
LI 1422C Air to Water Heat Pump
Product Information: Product Name: Air-to-Water Heat Pump for
Indoor Installation Manufacturer: Glen Dimplex Deutschland Model
Numbers: LI 1422C, LI 1826C Order Number: 452170.66.01-EN Product
Usage Instructions: 1. Safety Notes: – The user manual contains
important safety information marked with “CAUTION!” and “NOTE”. –
“CAUTION!” indicates immediate danger to life, severe personal
injury, or significant property damage. 2. Intended Use: – The heat
pump is designed for indoor installation. – Follow the instructions
provided in the user manual for safe and proper use. 3. Scope of
Supply: – Refer to the user manual for a detailed list of
components included with the product. 4. Transport: – Follow the
guidelines provided in the user manual for safe transportation of
the heat pump. 5. Installation: – Detailed installation
instructions can be found in the user manual. – Ensure proper
electrical connections and plumbing according to the guidelines
provided. 6. Assembly: – Follow the assembly instructions provided
in the user manual. – Ensure all components are securely connected
and properly aligned. 7. Commissioning: – Refer to the user manual
for step-by-step instructions on how to commission the heat pump. –
Follow all safety precautions during the commissioning process. 8.
Cleaning/Maintenance: – Regular cleaning and maintenance are
essential for optimal performance. – Follow the guidelines provided
in the user manual for cleaning and maintenance procedures. 9.
Faults/Troubleshooting: – In case of any faults or issues, refer to
the troubleshooting section in the user manual. – Follow the
recommended steps to diagnose and rectify the problem. 10.
Decommissioning/Disposal: – When decommissioning or disposing of
the heat pump, follow the guidelines provided in the user manual. –
Ensure proper disposal methods are followed to protect the
environment. 11. Device Information: – Detailed information about
the heat pump can be found in this section of the user manual. 12.
Product Information: – This section provides information about the
product as per Regulation (EU) No 813/2013, Annex II, Table 2. 13.
Dimension Drawings: – Refer to the dimension drawings provided in
this section for accurate measurements and installation
requirements. 14. Diagrams: – Detailed diagrams are provided in
this section for better understanding of the heat pump’s components
and connections. 15. Integration Diagram: – This section provides
an integration diagram for connecting the heat pump to other
systems. 16. Declaration of Conformity: – The user manual includes
a declaration of conformity to applicable standards and
regulations. For more information and support, visit the
manufacturer’s website: www.dimplex.de
LI 1422C LI 1826C
Glen Dimplex
Deutschland
Dimplex
Installation and Operating Instruction
Air-to-Water Heat Pump for Indoor Installation
Order no.: 452170.66.01-EN
EN · FD 0303
LI 1422C – 1826C
English
Table of contents
1 Safety notes………………………………………………………………………………………………………………………………..EN-2
1.1 Symbols and markings …………………………………………………………………………………………………………………………………EN-2
1.2 General safety information
………………………………………………………………………………………………………………………….EN-2 1.3 Intended
use………………………………………………………………………………………………………………………………………………….EN-3 1.4 Legal
regulations and directives …………………………………………………………………………………………………………………EN-3 1.5
Energy-efficient use of the heat
pump………………………………………………………………………………………………………EN-3
2 Intended use of the heat pump …………………………………………………………………………………………………EN-4
2.1 Area of
application………………………………………………………………………………………………………………………………………..EN-4 2.2
Operating principle……………………………………………………………………………………………………………………………………….EN-4
2.3 Functional description for integrated thermal energy metering.
…………………………………………………………..EN-4
3 Scope of supply ………………………………………………………………………………………………………………………….EN-5
3.1 Basic device …………………………………………………………………………………………………………………………………………………..EN-5
3.2 Switch box ……………………………………………………………………………………………………………………………………………………..EN-5
3.3 Heat pump manager …………………………………………………………………………………………………………………………………….EN-5
4 Transport …………………………………………………………………………………………………………………………………….EN-6
5 Installation ………………………………………………………………………………………………………………………………….EN-8
5.1 General……………………………………………………………………………………………………………………………………………………………EN-8 5.2
Condensate pipe …………………………………………………………………………………………………………………………………………..EN-8 5.3
Sound ……………………………………………………………………………………………………………………………………………………………..EN-8
6 Assembly …………………………………………………………………………………………………………………………………….EN-9
6.1 General……………………………………………………………………………………………………………………………………………………………EN-9 6.2
Air connection ……………………………………………………………………………………………………………………………………………….EN-9 6.3
Connection on heating side ……………………………………………………………………………………………………………………..
EN-10 6.4 Water Quality in Heating
Systems…………………………………………………………………………………………………………… EN-10 6.5 Electrical
connection ………………………………………………………………………………………………………………………………… EN-12
7 Commissioning ……………………………………………………………………………………………………………………….. EN-13
7.1 General………………………………………………………………………………………………………………………………………………………… EN-13
7.2 Preparation…………………………………………………………………………………………………………………………………………………. EN-13
7.3 Procedure …………………………………………………………………………………………………………………………………………………… EN-14
8 Cleaning / maintenance …………………………………………………………………………………………………………. EN-14
8.1 Care……………………………………………………………………………………………………………………………………………………………… EN-14 8.2
Cleaning the heating system …………………………………………………………………………………………………………………… EN-15
8.3 Cleaning the air system……………………………………………………………………………………………………………………………..
EN-15
9 Faults / troubleshooting …………………………………………………………………………………………………………. EN-15
10 Decommissioning/disposal ……………………………………………………………………………………………………. EN-15
11 Device information …………………………………………………………………………………………………………………. EN-16
12 Product information as per Regulation (EU) No 813/2013, Annex II, Table 2
……………………… EN-18
13 Dimension Drawings……………………………………………………………………………………………………………….. EN-20
13.1 Dmension Drawing …………………………………………………………………………………………………………………………………….
EN-20
14 Diagrams …………………………………………………………………………………………………………………………………. EN-21
14.1 Characteristic curves for heating operation LI 1422C
…………………………………………………………………………. EN-21 14.2 Characteristic curves for cooling
operation LI 1422C …………………………………………………………………………. EN-22 14.3 Characteristic
curves for heating operation LI 1826C …………………………………………………………………………. EN-23 14.4
Characteristic curves for cooling operation LI 1826C
…………………………………………………………………………. EN-24 14.5 Operating limits diagram heating
……………………………………………………………………………………………………………. EN-25 14.6 Operating limits diagram
cooling LI 1422C …………………………………………………………………………………………… EN-26 14.7 Operating
limits diagram cooling LI 1826C …………………………………………………………………………………………… EN-27
15 Integration diagram ………………………………………………………………………………………………………………… EN-28
15.1 Hydraulic integration diagrams
……………………………………………………………………………………………………………….. EN-28 15.2 Hydraulic integration
diagrams ……………………………………………………………………………………………………………….. EN-29 15.3 Legend
………………………………………………………………………………………………………………………………………………………… EN-30
16 Declaration of Conformity ……………………………………………………………………………………………………… EN-31
www.dimplex.de
452170.66.01-EN · FD 0303
EN-1
English
LI 1422C – 1826C
1 Safety notes
1.1 Symbols and markings
Particularly important information in these instructions is marked with
CAUTION! and NOTE.
! CAUTION!
Immediate danger to life or danger of severe personal injury or significant
damage to property.
º NOTE
Risk of damage to property or minor personal injury or important information
with no further risk of personal injury or damage to property.
1.2 General safety information
The following warnings and safety notes must be observed in all life phases of
the device:
! CAUTION!
Work on the heat pump must only be performed by authorised and qualified
after-sales service technicians!
! CAUTION!
Failure to use personal protective equipment could result in severe injury.
Risk of injury!
Use of personal protective equipment (PPE) in accordance with DGUV regulation
100-500 Chap. 2.35
Personal protective equipment consisting of safety gloves, safety shoes,
safety glasses and long, closed clothing must be used.
! CAUTION!
There is a risk of falling or slipping on trip hazards and leaking operating
materials. Risk of injury!
Trip hazards caused by cables, pipes and hoses must be avoided.
Operating material leaks must be absorbed with suitable binding agents and
disposed of in accordance with the hazard class.
! CAUTION!
Before opening the device, ensure that all circuits are powered down.
! CAUTION!
Failure to observe the safety rules could result in electric shock. Danger to
life!
National and regional regulations on accident prevention and carrying out
electrical installations must be observed.
The five safety rules must be applied when carrying out electrical
installations: – Disconnect, – Secure against being switched on again, –
Ensure that there is an absence of voltage at all poles. – Earth and short
circuit, -Cover or cordon off neighbouring live parts. After disconnecting the
power supply, you have to wait 5 minutes before all components are de-
energised.
! CAUTION!
It is forbidden to operate the heat pump without safety devices (cover,
grating).
! CAUTION!
Please refrain from tampering with or altering the device.
EN-2
452170.66.01-EN · FD 0303
www.dimplex.de
LI 1422C – 1826C
English
1.3 Intended use
This device is only intended for use as specified by the manufacturer. Any
other use beyond that intended by the manufacturer is prohibited. This
requires the user to abide by the relevant project planning documents.
1.4 Legal regulations and directives
This heat pump is designed for use in a domestic environment according to
Article 1, Paragraph 2 k) of EU directive 2006/42/ EC (Machinery Directive)
and is thus subject to the requirements of EU directive 2014/35/EU (Low
Voltage Directive). It is thus also intended for use by non-professionals for
heating shops, offices and other similar working environments, agricultural
establishments and hotels, guest houses and other residential buildings.
The construction and design of the heat pump complies with all relevant EU
directives, and DIN/VDE regulations (see CE declaration of conformity).
When connecting the heat pump to the power supply, the relevant VDE, EN and
IEC standards are to be adhered to. Any further connection requirements
stipulated by local utility companies must also be observed.
When connecting the heating system, all applicable regulations must also be
adhered to.
This unit can be used by children aged 8 and over and by persons with limited
physical, sensory or mental aptitude or lack of experience and/or knowledge,
providing they are supervised or have been instructed in safe use of the unit
and understand the associated potential dangers.
Children must not play with the device. Cleaning and user maintenance must not
be carried out by children without supervision.
º NOTE
When operating or maintaining a heat pump, the legal requirements of the
country where the heat pump is operated apply. Depending on the refrigerant
fill quantity, the heat pump must be inspected for leaks at regular intervals
by a certified technician, and these inspections must be recorded.
More information can be found in the accompanying log book.
1.5 Energy-efficient use of the heat
pump
With the purchase of this heat pump, you are helping to protect the
environment. A prerequisite for energy-efficient operation is the correct
design of the heat source system and heating system.
To maintain heat pump efficiency, it is particularly important to keep the
temperature difference between the heating water and heat source to a minimum.
For this reason, it is advisable to design the heat source and heating system
very carefully. A temperature difference of approx. 1 Kelvin (1 °C) increases
the power consumption by around 2.5 %. When designing the heating system, it
should be borne in mind that special consumers such as domestic hot water
preparation should also be taken into consideration and dimensioned for low
temperatures. Underfloor heating systems (panel heating) are optimally suited
for heat pump use on account of the low flow temperatures (30 °C to 40 °C).
It is important to ensure that the heat exchangers are not contaminated during
operation, as this increases the temperature difference, which in turn reduces
the coefficient of performance (COP).
When set correctly, the heat pump manager is also an essential factor in the
energy-efficient use of the heat pump. Further information can be found in the
heat pump manager operating instructions.
www.dimplex.de
452170.66.01-EN · FD 0303
EN-3
English
LI 1422C – 1826C
2 Intended use of the heat pump
2.1 Area of application
The air-to-water heat pump is to be used exclusively for the heating and
cooling of heating water. It can be used in new or existing heating systems.
The heat pump is suitable for mono energy and bivalent operation in outside
air temperatures to -22 °C.
Proper defrosting of the evaporator is guaranteed by maintaining a heating
water return temperature of more than 22 °C (+2 °C/-0 °C) during continuous
operation.
The heat pump is not designed for the increased heat consumption required when
a building is being dried out. For this reason, the additional heat
consumption should be met using special devices provided by the customer. If a
building is to be dried out in autumn or winter, we recommend installing an
additional electric heating element (available as an accessory).
In cooling operation, the heat pump is suitable for air temperatures ranging
from +15 °C to + 45 °C. It can be used for silent and dynamic cooling. The
minimum cooling water inlet temperature see “Device information” on page 16.
º NOTE
The device is not suitable for operation with a frequency converter.
2.2 Operating principle
Heat
Outside air is drawn in by the ventilator and fed via the evaporator (heat
exchanger). The evaporator cools the air, i.e. extracts heat from it. This
extracted heat is then transferred to the working medium (refrigerant) in the
evaporator.
The heat is “pumped” to a higher temperature level by increasing its pressure
with the aid of the electrically driven compressors. It is then transferred to
the heating water via the liquefier (heat exchanger).
Electrical energy is used to raise the temperature level of the heat from the
environment. Since the energy extracted from the air is transferred to the
heating water, this type of device is referred to as an air-to-water heat
pump.
Main components of the air-to-water heat pump are the evaporator, fan,
expansion valve, 4-way reversing valve, as well as the compressor, the
liquefier and the electrical control system.
At low ambient temperatures, humidity accumulates on the evaporator in the
form of frost, reducing the transfer of heat. Uneven accumulation during this
process does not indicate a fault. The evaporator is defrosted automatically
by the heat pump as required. Under certain atmospheric conditions, steam may
be emitted from the air outlet.
Cooling
The functions of the evaporator and the liquefier are reversed in the
“Cooling” operating mode.
The heating water transfers its heat to the refrigerant via the liquefier,
which is now functioning as an evaporator. The refrigerant is brought to a
higher temperature level using the compressor. Heat is transferred to the
surrounding air via the liquefier (which, in heating operation, functions as
an evaporator).
2.3 Functional description for integrated thermal energy metering.
The compressor manufacturer’s performance specifications for different
pressure levels are stored in the heat pump software. Two additional pressure
sensors for determining the current pressure level are installed in the
refrigerating circuit, one before and one after the compressor. The current
heat output can be calculated from the compressor data stored in the software
and the current pressure level. The integral for the heat output over the
runtime gives the quantity of thermal energy supplied by the heat pump, which
is displayed separately for heating, domestic hot water preparation and
swimming pool water preparation on the heat pump manager display.
The integrated thermal energy metering must not be used for heating cost
billing purposes. EN 1434 is not applicable.
EN-4
452170.66.01-EN · FD 0303
www.dimplex.de
LI 1422C – 1826C
3 Scope of supply
3.1 Basic device
The heat pump contains the components listed below. The refrigeration circuit
is “hermetically sealed” and contains the fluorinated refrigerant R410A
incorporated in the Kyoto protocol. Information on the GWP value and CO2
equivalent of the refrigerant is available under “Device information”. The
refrigerant is CFC-free, non-ozone depleting and non-combustible.
English
1 2
7
4 3
5
6
- Evaporators 2) Fan 3) Switch box 4) Dirt trap 5) Liquefier 6) Filter dryer
- Compressor
3.2 Switch box
The switch box located in the device can be folded out once the bottom front cover has been removed and the fixing screw has been loosened. The power supply terminals, power contactors, the soft starter units and the extended controller unit (refrigeration circuit control) are inside the switch box. The refrigeration circuit control monitors and controls all heat pump signals and communicates with the heat pump manager. Communication and control or mains cables, which should be routed apart from each other, are fed into the switch box through the cable entry area on the side plate.
3.3 Heat pump manager
The heat pump manager included in the scope of supply must be used to operate
the air-to-water heat pump.
The heat pump manager is a convenient electronic regulation and control
device. It controls and monitors the entire heating system based on the
outside temperature, as well as domestic hot water preparation and safety
systems.
Sensors for heating demand and outside temperature to be installed on site,
including mounting material, are included with the heat pump manager.
The functions and usage of the heat pump manager are described in the
operating instructions supplied with it.
www.dimplex.de
452170.66.01-EN · FD 0303
EN-5
English
LI 1422C – 1826C
4 Transport
! CAUTION!
Risk of injury when lifting and setting down the load. Risk of crushing!
Do not stand under the load when lifting and setting down.
! CAUTION!
Risk of injury if unsuitable lifting devices are used incorrectly. Risk of
falling and crushing!
People may only stand outside the danger area. (Germany: DGUV regulation
100-500 Chap. 2.3)
Observe the load capacity of the lifting devices and slings used. (Germany:
DGUV regulation 100-500 Chap. 2.8)
! CAUTION!
Risk of the heat pump tipping over if unsuitable attachment points are used.
Risk of falling and crushing!
The heat pump may only be lifted from the operator side with a lift truck or
forklift.
! CAUTION!
Work may only be carried out on the device outdoors in dry weather conditions.
Risk of damage to the device or electric shock!
In wet weather conditions such as rain, snow etc., the housing of the heat
pump must be kept properly closed
! CAUTION!
Do not stand near the device during storms. Risk of lightening!
Do not stand in the immediate vicinity of the heat pump.
! CAUTION!
Weather-related conditions on transport routes. Risk of injury due to
slipping!
Transport routes must be kept clear and weather-related conditions such as ice
and snow must not impair safe transport.
! CAUTION!
The heat pump must not be tipped during transport. The machine must be secured
to prevent the risk of tipping.
A pallet should be used to transport the heat pump to its final installation
location. The basic device can be transported with a lift truck, hand truck or
by means of 3/4″ pipes fed through the holes in the baseplate or frame.
Before using the transport holes in the frame, it is necessary to remove the
lower side panel assemblies. This is done by loosening each of the two screws
at the base and then withdrawing the panels by unhooking them from above.
Rehang the panels by gently pushing them in an upwards direction.
Be careful not to damage any components when inserting the pipes through the
frame.
Any transport holes are to be covered at the installation location using the 8
black dust caps, which are included in the device’s accessories pack.
1. 2. Opening the cover
Closing the cover
After transportation, the transport fastening in the device is to be removed from both sides of the base.
Remove (2 screw)
transport lock
º NOTE
Before commissioning, the transport fastening must be
removed.
EN-6
452170.66.01-EN · FD 0303
www.dimplex.de
LI 1422C – 1826C
For easier transportation into existing homes/buildings, it is possible to separate the basic device into two parts.
Once the covering panels have been removed, please proceed as follows:
-
Drain refrigerant
-
Remove condensate hose
-
Loosen the switch box from the frame
-
Remove the pipe insulation above the soldering points
-
Separate 4x soldering points chip-free.
-
Disconnect the fan cable in the switch box
-
Unfasten 4x screws in the corners in each case
-
Lift down the top part of the heat pump
-
Areas for lifting on the frame
-
Transport heat pump to the installation location
-
Join the parts
4+5
- Re-solder the separation points again (with inert gas flush-
ing)
-
Evacuate the refrigeration circuit
-
Add refrigerant
-
Perform leakage tightness test
-
Re-attach pipe insulation
-
Re-connect fan
-
Bores for attaching a transport aid (e.g. lifting straps etc.)
-
Remove the transport locks on the base on both sides be-
fore commissioning
18
º NOTE
Do not lift by the condensate tray. This cannot withstand any
forces.
º NOTE
The condensate hose must be removed before the upper part
is put down.
18
English
3 2
9
8
1237 758
www.dimplex.de
452170.66.01-EN · FD 0303
7
EN-7
English
LI 1422C – 1826C
5 Installation
5.1 General
The air-to-water heat pump must be installed in a frost-free, dry room on an
even, smooth and horizontal surface. The entire base of the frame should lie
directly on the floor to ensure an adequate soundproof seal. If this is not
the case, additional sound insulation measures may be necessary. The heat pump
must be installed in a way that allows maintenance work to be carried out
without hindrance. This is ensured when observing the distances to solid walls
as shown in the figure.
0,2 m
0,6 m
0,6 m
5.2 Condensate pipe
Condensate that forms during operation must be drained off frost free. To
ensure proper drainage, the heat pump must be mounted horizontally. The
condensate pipe must have a minimum diameter of 50 mm and must be fed into a
sewer in such a way that it is safe from frost. Do not discharge the
condensate directly into clearing tanks or cess pits. The aggressive vapours
and a condensate pipe laid in an area which is not frost-free can destroy the
evaporator.
5.3 Sound
To prevent solid-borne sound from being transmitted to the heating system, we
recommend connecting the heat pump to the heating system using a flexible
hose. Installed air ducts should be sound-isolated from the heat pump to
prevent the transmission of solid-borne sound to the ducts.
1m
º NOTE
The heat pump is not intended for use above 2000 metres (mean sea level).
Never install the device in rooms subject to high humidity. Condensation can
form on the heat pump and air circuit if the humidity exceeds 50 % and the
external temperature is below 0 °C. Neither frost nor temperatures higher than
35 °C must occur in the installation room at any time of the year. If the heat
pump is installed on an upper storey, the load-bearing capacity of the ceiling
should be checked. On account of the acoustics, measures for isolating
possible vibrations should also be very carefully planned in advance as well.
Installation on floors above wooden ceilings is not recommended.
EN-8
452170.66.01-EN · FD 0303
www.dimplex.de
LI 1422C – 1826C
English
6 Assembly
6.1 General
The following connections need to be established on the heat pump: – Fresh and
exhaust air – Flow and return of the heating system – Communication line (heat
pump manager) – Control voltage line (heat pump manager) – Supply voltage line
(electrical distribution system) – Condensate outflow
6.2 Air connection
º NOTE
Do not restrict or block the area around the intake or the air outlet area.
º NOTE
Only operate the heat pump with the air ducts connected.
The glass fibre reinforced concrete air ducts offered as accessories are
moisture-resistant and diffusion-free. The following components are available:
Channel Bend Connection set Connection frame Sealing collar The sealing collar
is used to seal the air ducts on the heat pump. The air ducts themselves are
not screwed directly onto the heat pump. When the system is installed ready
for operation, only the rubber seal comes into direct contact with the heat
pump. This guarantees easy assembly and disassembly of the heat pump and also
ensures that solid-borne noise is well insulated.
Connection of onsite air duct
If an alternative type of air duct is used to the one available as an
accessory, the external and internal dimensions as specified in the drawing
must be adhered to. Also ensure that the vibration and duct insulation are
adequate. If flange-mounted air ducts are used, connecting stubs are secured
on the air inlet and air outlet sides of the evaporator with 4 M8 x 16 hexagon
bolts in the threaded holes provided. When doing this, ensure that both air
duct stubs touch only the insulation. There should be no contact with the
external sheeting.
785
M 8 x 16
min. 725
max. 805
www.dimplex.de
452170.66.01-EN · FD 0303
EN-9
English
LI 1422C – 1826C
6.3 Connection on heating side
The heating system connections on the heat pump have a 1 1/4″ external thread.
A spanner must be used to firmly grip the transitions when connecting the heat
pump.
! CAUTION!
Fault on the safety switching equipment of the hydraulic circuit intended for
pressure limitation. Risk of injury!
The safety switching equipment of the hydraulic circuit intended for pressure
limitation must be checked for proper installation and functionality before
commissioning.
Before connecting the heating water system to the heat pump, the heating
system must be flushed to remove any impurities, residue from sealants, etc.
Any accumulation of deposits in the liquefier may cause the heat pump to
completely break down. For systems in which the heating water flow rate can be
shut off via the radiator or thermostat valves, an overflow valve must be
installed by the customer in a heating bypass downstream from the heat pump.
This ensures a minimum heating water flow rate through the heat pump and helps
to avoid faults.
Once the heat pump has been connected to the heating system, it must be
filled, purged and pressure-tested.
6.4 Water Quality in Heating Systems
6.4.1 Scale Formation
Scale formation in heating systems cannot be avoided, but in systems with flow
temperatures below 60 °C the problem is so small that it is negligible. With
high-temperature heat pumps and in particular with bivalent systems in the
higher performance range (heat pump + boiler combination), flow temperatures
of 60 °C and more can be achieved. One preferred method for preventing scale
formation is softening because this permanently removes alkaline earths
(calcium and magnesium ions) from the heating system.
The following values for water quality in heating water and cold water must be
observed and checked during an on-site check:
Degree of hardness Conductivity pH value Filterable materials
The following (limit) values must absolutely be observed: Maximum degree of
hardness in filling water and supplementary water 11 dGH. The conductivity in
demineralised water (DM water) (lowsalt) may not be greater than 100 S/cm. The
conductivity in partially demineralised water (saline) may not be greater than
500 S/cm. The pH value must be between 8.2 and 9. The limit value for
filterable materials in heating water is < 30 mg/l
If necessary, for example in bivalent systems, the specifications listed in
the table below must also be observed, or the precise guidelines for filling
water and supplementary water and the total hardness must be taken from the
table in accordance with VDI 2035 Sheet 1.
º NOTE
The specific volumes of a heating system must be determined
before filling the system.
The saturation index SI is used to determine whether water has a tendency
towards lime dissolution or lime separation. This shows whether the pH value
corresponds to a neutral pH point or by how much it undershoots it due to
excess acid or by how much it exceeds it due to carbonic acid deficit. At a
saturation index below 0, the water is aggressive and will tend towards
corrosion. At a saturation index above 0, the water is calcareous.
The saturation index SI should be between – 0.2 < 0 < 0.2
Filling and supplementary water as well as heating water, depending on heat output
Total alkaline earths in mol/m³ (Total hardness in dGH)
Overall heat output in kW
20
20 to 50
50
Specific system volume in l/kW Heat output 1
50 specific water content heat generator > 0.3 k per kW 2
none
3.0 (16.8)
50 specific water content heat generator > 0.3 k per kW 2 (e.g. circulating
water heaters) and systems with electric heat-
ing elements
3.0 (16.8)
1.5 (8.4)
< 0.05 (0.3)
50 kW to 200 kW
2.0 (11.2) 1.0 (5.6)
200 kW to 600 kW > 600 kW
1.5 (8.4) < 0.05 (0.3)
< 0.05 (0.3)
Heating water, depending on heating output
Operating mode
Electrical conductivity in µS/cm
Low-salt 3
10 to 100
Containing salt
100 to 1500
Appearance
clear, free from sedimentary substances
1. For the purpose of calculating the specific system volume, the smallest
individual heat output is to be used for systems with several heat generators.
2. In systems with several heat generators with different specific water
contents, the smallest specific water content is decisive.
3. Full softening is recommended for systems with aluminium alloys.
Fig. 6.1:Guideline values for filling and supplementary in accordance with VDI
2035
! CAUTION!
When using demineralised water, ensure that the minimum permissible pH value
of 8.2 is not undershot. Failure to comply with this value can result in the
heat pump being destroyed.
EN-10
452170.66.01-EN · FD 0303
www.dimplex.de
LI 1422C – 1826C
English
6.4.2 Corrosion
The VDI 2035 recommends the use of partially demineralised water or
demineralised water in systems with larger-than-average specific system
volumes of 50 l/kW.
These measures (e.g. pH stabilizers) are implemented to set the pH value of
the heating water to minimise the risk of corrosion in the heat pump and in
the heating system.
Irrespective of the legal requirements, the following limit values in the
heating water used for various substances must not be undershot or exceeded.
This is to ensure safe operation of the heat pump. A water analysis must be
carried out before commissioning the system. If the water analysis produces a
“-” for a maximum of one indicator or a “o” for a maximum of two indicators,
the analysis must be classed as negative.
Evaluation characteristic Bicarbonate (HCO3-) Sulphate (SO42-)
Hydrogencarbonate/sulphate HCO3-/SO42Electrical conductivity 1
pH value 2
Ammonium (NH4+) Chloride ions (Cl-)
Free chlorine (Cl2)
Hydrogen sulphide (H2S) Carbon dioxide (CO2)
Nitrate (NO3-) Iron (Fe) Aluminium (Al) Manganese (Mn)
Concentration range
(mg/l or ppm) < 70
70 – 300 > 300 < 70
70 – 300 > 300 > 1.0 < 1.0
< 10 µS/cm 10 – 500 µS/cm
500 µS/cm < 6.0
6.0 – 8.2 8.2 – 9.0
9.0 < 2 2 – 20 > 20 < 50 50 – 150 > 150 < 0.5 0.5 – 5 > 5 < 0.05 > 0.05 < 5 5 – 10 > 10 < 100 > 100 < 0.2 > 0.2 < 0.2 > 0.2 < 0.05 > 0.05
Stainless steel
Copper
o
o
o
o/-
–
–
o
–
o
o
o
o
–
–
o
o
o
o
o
o
–
–
o
o
–
–
–
o
–
–
o/-
o
o
–
o
o
o
o
o
o
o
Saturation Index
Filterable materials Total hardness Oxygen (O2) Nitrite (NO2-) Sulphide (S2-)
< -0.2 -0.2 – 0.1 0.1 – 0.2
0.2 < 30 > 30 < 6 °dGH 6 – 11 °dGH > 11 °dGH < 0.02 < 0.1 > 0.1 < 0.1 > 0.1 < 1.0 > 1.0
o
o
o
o
o
–
–
o/+
o/+
–
–
+/o
+/o
–
–
–
–
–
–
1. If the limit values in the VDI 2035 are more restrictive, these apply
accordingly.
2. When using demineralised water, ensure that the minimum permissible pH
value of 8.2 is not undershot. Failure to comply with this value can result in
the heat pump being destroyed.
Fig. 6.2:Limit values for the quality of heating water
Resistance of copper-soldered or welded stainless-steel plate heat exchangers
to the substances present in water:
Notes “+” = Normally good resistance “o” = Corrosion problems may
arise,particularly if several factors receive an evaluation of “o” “-” =
Should not be used
º NOTE
The water quality should be checked again after 4 to 6 weeks, as the quality
could change during the first few weeks of operation due to chemical
reactions.
º NOTE
It is mandatory to use hydraulically closed systems. It is not
permissible to use any open hydraulic systems!
www.dimplex.de
452170.66.01-EN · FD 0303
EN-11
English
LI 1422C – 1826C
Minimum heating water flow rate
The minimum heating water flow rate through the heat pump must be assured in
all operating states of the heating system. This can be accomplished, for
example, by installing either a dual differential pressureless manifold or an
overflow valve. The procedure for setting an overflow valve is described in
the chapter “Commissioning”. When the minimum heating water flow is undershot,
the plate heat exchanger in the refrigeration circuit can freeze, which can
lead to total loss of the heat pump.
The nominal flow rate is specified depending on the max. flow temperature in
the device information and must be taken into account during planning. With
design temperatures below 30 °C in the flow, the design must be based on the
max. volume flow with 5 K spread for A7/W35.
The specified nominal flow rate (see “Device information” on page 16.) must be
assured in all operating states. A built-in flow rate sensor is used only for
switching off the heat pump in the event of an unusual and abrupt drop in the
heating water flow rate and not for monitoring and fusing the nominal flow
rate.
º NOTE
The use of an overflow valve is only recommended for panel heating and a
maximum heating water flow of 1.3 m³/h. System faults may result if this is
not observed.
Frost protection
A method of manual drainage (see illustration) should be provided for heat
pumps which are exposed to frost. The frost protection function of the heat
pump manager is active whenever the heat pump manager and the heat circulating
pump are ready for operation. In the event of decommissioning or power
failure, the system must be drained and, if necessary, blown out at the points
shown (see illustration). For heat pump systems where a power failure cannot
be detected (holiday home), the heating circuit must be operated with suitable
non-toxic antifreeze (such as polypropylene glycol) added at the concentration
specified by the antifreeze manufacturer.
6.5 Electrical connection
6.5.1 General
All electrical installation work must be carried out by a trained electrician
or a specialist for the specified tasks in accordance with the
installation and operating instructions, country-specific installation
regulations (e.g. VDE 0100), technical connection conditions of the energy
supplier and supply grid operator (e.g. TAB) and local conditions.
To ensure that the frost protection function of the heat pump works properly,
the heat pump manager must remain connected to the power supply and the flow
must be maintained through the heat pump at all times.
The switching contacts of the output relay are interferencesuppressed.
Therefore, depending on the internal resistance of the measuring instrument, a
voltage can also be measured when the contacts are open. However, this will be
much lower than the line voltage.
Controller terminals -N0/J2..J15; -N1/J1..15, J25 and J26 or the LV adapter
boards are connected to extra-low voltage. If, due to a wiring error, the line
voltage is mistakenly connected to these points, the controller will be
destroyed.
1
2
Fig. 6.3:
! CAUTION!
Swallowing or contact with glycol and glycol mixtures. Risk of poisoning!
When using glycol and glycol mixtures, the valid national and regional
regulations on environmental protection, water protection and worker
protection must be observed.
Workers must be instructed in the dangers and risks associated with glycol and
glycol mixtures.
In Germany, operating instructions in accordance with §14 of the Ordinance on
Hazardous Substances (GefStoffV) must be created. Otherwise, country-specific
regulations must be observed.
EN-12
452170.66.01-EN · FD 0303
www.dimplex.de
LI 1422C – 1826C
English
6.5.2 Electrical installation work
3 lines/cables must be routed to the heat pump in total: A standard 5-core
cable is used to connect the heat pump to the power supply. The cable must be
provided on-site. The conductor cross section is selected in accordance with
the power consumption of the heat pump (see attachment Device Information) and
the applicable VDE (EN) and VNB regulations. An all-pole disconnecting device
with a contact gap of at least 3 mm (e.g. utility blocking contactor or power
contactor) must be installed in the heat pump power supply. A 3pole circuit
breaker with joint tripping of all outer conductors (trip current in
accordance with device information) provides the short circuit protection
taking into account the layout of the internal wiring. The relevant components
in the heat pump contain an internal overload protection. When connecting,
ensure that the incoming supply has a clockwise rotating field. Phase
sequence: L1, L2, L3.
º NOTE
Ensure that there is a clockwise rotating field: With incorrect wiring,
starting of the heat pump is prevented. A corresponding warning is indicated
on the display of the heat pump manager (adjust wiring).
The control voltage is supplied via the heat pump manager. A 3-pole line must
be laid for this in accordance with the electrical documentation. Further
information on the wiring of the heat pump manager is available in the heat
pump manager operating instructions.
A shielded communication line (e.g. data line; shielded: JY(ST)Y 2 x 2×0.6
(not included in the scope of supply) connects the heat pump manager to the
refrigeration circuit controller installed in the heat pump. More detailed
instructions can be found in the heat pump manager operating instructions and
in the electrical documentation.
º NOTE
The communication cable is necessary for the function of airto-water heat
pumps. It must be shielded and laid separately from the mains cable.
6.5.3 Demand sensor connection
The demand sensor R2.2 (NTC 10) is included with the heat pump manager. It
must be installed depending on the hydraulics used (see Appendix Chap. 3 on P.
V).
If a demand sensor is not connected, the second heat generator cannot be
controlled with the heat pump manager in the event of an interruption in
communication .
º NOTE
The return sensor R2 installed in the heat pump is active when the compressor
is running and must not be disconnected.
7 Commissioning
7.1 General
To ensure that commissioning is performed correctly, it should only be carried
out by an after-sales service technician authorised by the manufacturer. This
may be a condition for an additional warranty (see “Warranty service”).
7.2 Preparation
The following items must be checked prior to commissioning: All of the heat
pump connections must be installed as described in Chapter 6. The transport
locks on the compressor must be removed. All valves which could impair the
proper flow of the heating water in the heating circuit must be open. The air
intake and air outlet paths must be clear. The fan must turn in the direction
indicated by the arrow. The settings of the heat pump manager must be adapted
to the heating system in accordance with the operating instructions. Ensure
that the condensate drain functions properly. The hydraulic network must be
flushed correctly before installing the heat pump. This includes the supply
line to the heat pump. Only when flushing is complete can the heat pump be
hydraulically integrated. The dirt traps present as standard or included for
assembly must be inspected between 4 and 8 weeks after the heat pump is
commissioned or changes made to the heating system and cleaned if necessary.
Further maintenance intervals must be scheduled depending on the level of
soiling, which must be defined and carried out by a suitably qualified person.
Special notes for the integration of heat pumps in existing systems
(renovations):
The existing heat distribution network (pipe materials, connection types,
etc.) and the existing heating systems (e.g. radiators, underfloor heating,
etc.) can impact the quality of the water in existing systems. Particularly
when welded steel pipes or pipes that are not oxygen diffusion-proof are used,
deposits, scaling, silting or similar may be present that can cause damage in
the heat pump system. This can result in a total failure of the heat pump The
following measures must be observed to avoid this:
Compliance with the water properties and water quality Flushing of the
hydraulic system Maintenance interval of the dirt traps If silting or
ferromagnetic particles are to be expected in
the hydraulic network, dirt separators or magnetite separators must be
installed on-site before the medium enters the heat pump. The maintenance
intervals must be defined by a suitably qualified person.
www.dimplex.de
452170.66.01-EN · FD 0303
EN-13
English
LI 1422C – 1826C
7.3 Procedure
The heat pump is commissioned via the heat pump manager. Settings should be
made in compliance with the heat pump manager’s instructions. If an overflow
valve is fitted to ensure a minimum heating water flow, the overflow valve
must be set in accordance with the requirements of the respective heating
system. Incorrect adjustment can lead to faulty operation and increased energy
consumption. We recommend carrying out the following procedure to set the
overflow valve correctly: Close all heating circuits that may also be closed
during operation (depending on how the heat pump is being used) so that the
most unfavourable operating status with regard to the water flow is achieved.
This normally means the heating circuits of the rooms on the south and west
sides of the building. At least one heating circuit must remain open (e.g.
bathroom). The overflow valve should be opened far enough to produce the
maximum temperature spread between the heat flow and heat return flow, listed
in the following table, for the current heat source temperature. The
temperature spread should be measured as close as possible to the heat pump.
The heating element of mono energy systems should be disconnected during
commissioning.
Heat source temperature
from
to
max. temperature spread between flow and return
-20 °C
-15 °C
4 K
-14 °C
-10 °C
5 K
-9 °C
-5 °C
6 K
-4 °C
0 °C
7 K
1 °C
5 °C
8 K
6 °C
10 °C
9 K
11 °C
15 °C
10 K
16 °C
20 °C
11 K
21 °C
25 °C
12 K
26 °C
30 °C
13 K
31 °C
35 °C
14 K
At heating water temperatures under 7°C, commissioning is not possible. The water in the buffer tank must be heated with the 2nd heat generator to at least 18 °C.
To ensure problem-free commissioning, the following procedure is to be
implemented: 1) Close all consumer circuits. 2) Ensure that the heat pump has
the correct water flow. 3) Select “Winter” mode on the heat pump manager. 4)
In the special functions menu, start the “Commissioning”
program. 5) Wait until a return temperature of at least 25 °C has been
reached. 6) Now slowly reopen the heating circuit valves in succession
so that the heating water flow rate is constantly raised by slightly opening
the respective heating circuit. The heating water temperature in the buffer
tank must not be allowed to drop below 20 °C during this process. This ensures
that the heat pump can be defrosted at any time. 7) When all heating circuits
are fully open and a return temperature of at least 18 °C is maintained, the
commissioning is complete.
º NOTE
Operating the heat pump at low system temperatures may cause the heat pump to
break down completely.
8 Cleaning / maintenance
8.1 Care
To protect the paintwork, avoid leaning anything against the device or putting
objects on the device. External heat pump parts can be wiped with a damp cloth
and commercially available domestic cleaner.
º NOTE
Never use cleaning agents containing sand, soda, acid or chloride, as these
can damage the surfaces.
To prevent faults due to sediment in the heat exchanger of the heat pump,
ensure that the heat exchanger in the heating system cannot be contaminated.
We recommend protecting the evaporator by installing a bird guard in the inlet
duct. At least 80% of the cross section of the grating should be open. Should
operating malfunctions due to contamination still occur, however, the system
should be cleaned as described below.
EN-14
452170.66.01-EN · FD 0303
www.dimplex.de
LI 1422C – 1826C
English
8.2 Cleaning the heating system
º NOTE
Pressure relief devices must be checked and maintained regularly.
º NOTE
The integrated dirt trap must be cleaned at regular intervals.
The maintenance intervals should be defined according to the degree of soiling
in the system. The filter insert should also be cleaned.
For cleaning, the heating circuit must be made pressureless in the vicinity of
the dirt trap, the filter compartment unscrewed, and the filter insert removed
and cleaned. Assembly carried out in reverse order requires attention to
correct assembly of the screen inserts and tightness of the screw joints.
The ingress of oxygen into the heating water circuit may result in the
formation of oxidation products (rust), particularly if steel components are
used. These enter the heating system via the valves, the circulating pumps
and/or plastic pipes. A diffusionresistant installation is therefore
essential, especially with regard to the piping of underfloor heating systems.
º NOTE
We recommend the installation of a suitable corrosion protection system to
prevent the formation of deposits (e.g. rust) in the condenser of the heat
pump.
Residue from lubricants and sealants may also contaminate the heating water.
In the event of severe contamination leading to a reduction in the performance
of the liquefier in the heat pump, the system must be cleaned by a heating
technician. Based on current information, we recommend using a 5% phosphoric
acid solution for cleaning purposes. However, if cleaning needs to be
performed more frequently, a 5% formic acid solution should be used. In both
cases, the cleaning fluid should be at room temperature. We recommend flushing
the heat exchanger in the direction opposite to the normal flow direction. To
prevent acidic cleaning agents from entering the heating system circuit, we
recommend connecting the flushing device directly to the flow and return of
the liquefier of the heat pump.
It is then important that the system be thoroughly flushed using appropriate
neutralising agents to prevent any damage from being caused by cleaning agent
residue remaining in the system. Acids must be used with care and the
regulations of the employers liability insurance associations must be adhered
to. The instructions of the cleaning agent manufacturer must always be
observed.
8.3 Cleaning the air system
Air channels, air ducts, evaporator, ventilator and condensate outflow should
be cleaned of contamination (leaves, twigs, etc.) before each new heating
period. To do this, the heat pump must be opened at the side. The bottom
section should be opened first, followed by the top section.
Remove and rehang the side panel assemblies, as described in Chapter 4.
To prevent the evaporator and the condensate tray from being damaged, do not
use hard or sharp objects when cleaning.
9 Faults / troubleshooting
This heat pump is a quality product and is designed for troublefree operation.
Should a fault occur, however, it will be indicated on the heat pump manager
display. In this case, consult the “Faults and troubleshooting” page in the
operating instructions of the heat pump manager. If you cannot correct the
fault yourself, please contact your after-sales service technician.
10 Decommissioning/disposal
Before removing the heat pump, disconnect it from the power source and close
all valves. The heat pump must be dismantled by trained personnel. Observe all
environmental requirements regarding the recovery, recycling and disposal of
materials and components in accordance with all applicable standards.
Particular attention should be paid to the proper disposal of refrigerants and
refrigerant oils.
º NOTE
Use suitable transport devices.
! CAUTION!
Work may only be carried out on the device outdoors in dry weather conditions.
Risk of damage to the device or electric shock!
In wet weather conditions such as rain, snow etc., the housing of the heat
pump must be kept properly closed.
! CAUTION!
Weather-related conditions on transport routes. Risk of injury due to
slipping!
Transport routes must be kept clear and weather-related conditions such as ice
and snow must not impair safe transport.
! CAUTION!
Do not stand near the device during storms. Risk of lightening!
Do not stand in the immediate vicinity of the heat pump.
www.dimplex.de
452170.66.01-EN · FD 0303
EN-15
English
LI 1422C – 1826C
11 Device information
1 Type and order code
LI 1422C
LI 1826C
2 Design
2.1 Heat source
Air
Air
2.2 Seasonal coefficient of performance (COP) average climate 35 °C / 55 °C
179 % / 135 %
175 % / 135 %
2.3 Controller
WPM Touch
WPM Touch
2.4 Heat generator installation location
Inside
Inside
2.5 Heat source installation location
Inside
Inside
2.6 Thermal energy metering
Integrated
Integrated
2.7 Performance levels
2
2
3 Operating limits
3.1 Heating water flow / return 1 3.2 Air (heating) 1
°C
up to 60 ± 2K / from 22
°C
-22 to +35
up to 60 ± 2K / from 22 -22 to +35
3.3 Cooling water flow
°C
+7 to +20
+9 to +20
3.4 Air (cooling)
4 Flow2 / sound
°C
+15 to +45
+15 to +45
4.1 Heating water flow rate internal pressure differential
Nominal flow rate in accordance with 14511A7 / W35 … 30
m³/h / Pa
1.95 / 12900
2.5 / 12500
A7 / W45 … 40
m³/h / Pa
1.85 / 11500
2.4 / 11200
A7 / W55 … 47
m³/h / Pa
1.10 / 4800
1.45 / 2300
Minimum heating water flow
m³/h / Pa
1.10 / 4800
1.45/ —
4.2 Cooling water flow rate / internal pressure differential
Nominal flow rate in accordance with EN1451135 / W18 … 23
m³/h / Pa
3.3 / 37000
3.0 / 19300
Minimum cooling water flow
4.3 Sound power level according to EN12102 with A7 / W55
Indoors/outdoors 3 4
Normal operation
4.4 Sound power level according to EN12102 with A7 / W55
Indoors / outdoors 3 4
Reduced operation 5
4.5 Sound pressure level at a distance of 1 m indoors 3 4 6
4.6 Air flow with an external static pressure differential
5 Dimensions, weight and filling quantities
m³/h / Pa
dB(A)
dB(A) dB(A) m³/h /Pa m³/h /Pa
1.95 / 12900
54 / 56
53 / 54
46 5500 / 0 4000 /25
2.5 / 12500
57 / 60
55 / 58
49 8300 / 0 7300 / 25
5.1 Device dimensions 7
H x W x D mm
1770 x 750 x 1000
1770 x 750 x 1000
5.2 Device connections for heating
Inches
1 1/4″ thread
1 1/4″ thread
5.3 Weight of the transportable unit(s) incl. packaging
kg
307
326
5.4 Weight of head pump
kg
281
299
5.5 Refrigerant/total filling weight
Type/kg
R410A / 5.4
R410A / 6.6
5.6 GWP value / CO2 equivalent
— / t
2088 / 11
2088 / 14
5.7 Refrigeration circuit hermetically sealed
Yes
Yes
5.8 Lubricant/total filling quantity
Type/litres
Polyolester (POE)/2.48
Polyolester (POE)/2.48
5.9 Volume of heating water in the indoor component
litres
3.8
4.0
6 Electrical connection
6.1 Supply voltage/fusing/RCD type
3~/PE 400V (50Hz) / C16A / B 3~/PE 400V (50Hz) / C20A / B
6.2 Control voltage / fusing / RCD type
1~/N/PE 230V (50Hz) / C13A / A 1~/N/PE 230V (50Hz) / C13A / A
6.3 Degree of protection according to EN 60 529
IP 21
IP 21
6.4 Starting current limiter
Soft starter
Soft starter
6.5 Starting current
A
19
26
6.6 Nominal power consumption A2 W35/ max. power consumption 2
kW
4.7 / 8.0
5.1 / 9.9
6.7 Nominal current A2 / W35 / cos
A / —
8.5 / 0.8
9.2 / 0.8
6.8 Power consumption of fan
W
up to 300
up to 400
7 Complies with the European safety regulations
8
8
8 Additional model features
EN-16
452170.66.01-EN · FD 0303
www.dimplex.de
LI 1422C – 1826C
English
8.1 Type of defrosting
8.2 Condensate tray frost protection/water in device is protected from freezing 9
8.3 Max. operating overpressure (heat sink)
bar
9 Heat output / COP 2 5
9.1 Heat output / coefficient of performance (COP)
Reverse cycle Yes 3.0
EN 14511
Reverse cycle Yes 3.0
EN 14511
1
2
1
2
at A-7 / W35
kW / —
7.5 / 3.3
13.9 / 3.1
9.8 / 3.4
18.3 / 3.2
at A2 / W35
kW / —
at A7 / W35
kW / —
10 Cooling capacity / coefficient of performance (COP) 2 3
10.1 Cooling capacity / coefficient of performance (COP)
9.4 / 4.1 11.7 / 5.0
15.9 / 3.7 (20.9 / 4.7) 10
EN 14511
11.3 / 3.9 14.2 / 4.8
18.6 / 3.7 (21.3 / 4.2) 10
EN 14511
at A27 / W18
kW / —
1 10.4 / 4.0
2 21.0 / 3.6
1 10.9 / 3.3
2 19.2 / 2.6
at A27 / W7
kW / —
6.8 / 2.7
16.0 / 2.8
7.9 / 3.5
16.5 / 2.3
at A35 / W18 at A35 / W7
kW / –kW / —
10.3 / 4.0 6.5 / 2.3
19.3 / 2.9 14.8 / 2.3
9.5 / 2.5 7.0 / 1.9
17.7 / 2.1 14.9 / 1.9
1. For air temperatures between -22 °C and -5 °C, flow temperature increasing
from 45 °C to 60 °C. 2. This data indicates the size and capacity of the
system according to EN 14511. For an analysis of the economic and energy
efficiency of the system, the bivalence point and
the regulation should be taken into consideration. These figures are only
achieved with clean heat exchangers. Instructions for care, commissioning and
operation can be found in the relevant sections of the installation and
operation instructions. The specified values have the following meaning, e.g.
A2/W35: Heat source temperature 2 °C and heating water flow temperature 35 °C.
3. Tonal component according to DIN 45681 Table 1 is indoors 2 dB / outdoors 1
dB 4. Sound measurement takes place with two 90° bends and weather protection
grills on the intake and air outlet. 5. The heat output and COP is reduced by
approx. 5% in lower operation
6. The specified sound pressure level represents the free sound area level.
The measured value can vary by up to 16 dB(A), depending on the installation
location.
7. Note that additional space is required for pipe connections, operation and
maintenance. 8. see CE declaration of conformity
9. The heat circulating pump and the heat pump manager must always be ready
for operation.
10.Special operation, normal operation above 5 °C outside temperature 1
compressor operation
www.dimplex.de
452170.66.01-EN · FD 0303
EN-17
English
12 Product information as per Regulation (EU) No 813/ 2013, Annex II, Table 2
LI 1422C – 1826C
Information requirements for heat pump space heaters and heat pump combination heaters
Model
LI1422C
Air-to-water heat pump
yes
Water-to-water heat pump
no
Brine-to-water heat pump
no
Low-temperature heat pump
no
Equipped with a supplementary heater
no
Heat pump combination heater
no
Parameters shall be declared for medium-temperature application, except for low-temperature heat pumps. For low- temperature heat pumps, parameters shall be declared for low-temperature application.
Parameters shall be declared for average climate conditions:
Item Rated heat output (*)
Symbol Prated
Value 12
Unit
Item
Symbol
Value
Unit
Seasonal space heating energy
kW efficiency
s
135
%
Declared capacity for heating foer part load at indoor temperature 20°C and outdoor temperature Tj
Declared coefficient of performance or primary energy ratio for part load at indoor temperature 20 °C and outdoor temperature Tj
Tj = – 7°C
Pdh
Tj = + 2°C
Pdh
Tj = + 7°C
Pdh
Tj = + 12°C
Pdh
Tj = bivalent temperature
Pdh
Tj = operation limit temperature
Pdh
For air-to-water heat pumps
Tj = -15°C (if TOL < -20°C)
Pdh
Bivalent temperature
Tbiv
13,6
kW Tj = – 7°C
COPd
2,28
–
9,2
kW Tj = + 2°C
COPd
3,36
–
11,5
kW Tj = + 7°C
COPd
4,39
–
13,1
kW Tj = + 12°C
COPd
5,40
–
12,4
kW Tj = bivalent temperature
COPd
2,04
–
12,4
kW Tj = operation limit temperature
COPd
2,04
–
For air-to-water heat pumps:
–
kW Tj = -15°C (if TOL < -20°C)
For air-to-water heat pumps:
-10
°C
Operation limit temperature
COPd
–
–
TOL
-10
°C
Cycling interval capacity for heating
Pcych
Degradation co-efficient (**)
Cdh
Power consumption in modes other than active mode
Off mode Thermostat-off mode Standby mode Crankcase heater mode Other items
POFF PTO PSB PCK
Capacity control
Sound power level, indoors/ outdoors
LWA
Emissions of nitrogen oxides
NOx
0,99
0,020 0,020 0,020 0,000
fixed
54 /56 –
kW Cycling interval efficiency
Heating water operating limit
–
temperature
Supplementary heater
kW Rated heat output (*)
kW Type of energy input
kW
kW
COPcyc WTOL Psup
For air-to-water heat pumps: Rated
–
air flow rate, outdoors
For water-/brine-to-water heat
dB
pumps: Rated brine or water flow
–
mg/kWh rate, outdoor heat exchanger
60 0 eletrical
4000 —
°C kW
m³ /h m³ /h
For heat pump combination heater: Declared load profile
–
Water heating energy efficiency
wh
–
%
Daily electricity consumption
Qelec
–
kWh Daily fuel consumption
Qfuel
–
kWh
Contact details
Glen Dimplex Deutschland GmbH, Am Goldenen Feld 18, 95326 Kulmbach
(*) For heat pump space heaters and heat pump combination heaters, the rated output P rated is equal to the design load for heating Pdesignh , and the rated heat output of a supplementary capacity for heating sup(Tj ).
(**) If Cdh is not determined by measurement nthen the default degradation is C dh = 0,9 (–) not applicable
EN-18
452170.66.01-EN · FD 0303
www.dimplex.de
LI 1422C – 1826C
English
Information requirements for heat pump space heaters and heat pump combination heaters
Model
LI1826C
Air-to-water heat pump
yes
Water-to-water heat pump
no
Brine-to-water heat pump
no
Low-temperature heat pump
no
Equipped with a supplementary heater
no
Heat pump combination heater
no
Parameters shall be declared for medium-temperature application, except for low-temperature heat pumps. For low- temperature heat pumps, parameters shall be declared for low-temperature application.
Parameters shall be declared for average climate conditions:
Item Rated heat output (*)
Symbol Prated
Value 17
Unit
Item
Symbol
Value
Unit
Seasonal space heating energy
kW efficiency
s
135
%
Declared capacity for heating foer part load at indoor temperature 20°C and outdoor temperature Tj
Declared coefficient of performance or primary energy ratio for part load at indoor temperature 20 °C and outdoor temperature Tj
Tj = – 7°C
Pdh
Tj = + 2°C
Pdh
Tj = + 7°C
Pdh
Tj = + 12°C
Pdh
Tj = bivalent temperature
Pdh
Tj = operation limit temperature
Pdh
For air-to-water heat pumps
Tj = -15°C (if TOL < -20°C)
Pdh
Bivalent temperature
Tbiv
18,1
kW Tj = – 7°C
COPd
2,39
–
11,0
kW Tj = + 2°C
COPd
3,33
–
13,8
kW Tj = + 7°C
COPd
4,30
–
15,8
kW Tj = + 12°C
COPd
5,26
–
16,8
kW Tj = bivalent temperature
COPd
2,20
–
16,8
kW Tj = operation limit temperature
COPd
2,20
–
For air-to-water heat pumps:
–
kW Tj = -15°C (if TOL < -20°C)
For air-to-water heat pumps:
-10
°C
Operation limit temperature
COPd
–
–
TOL
-10
°C
Cycling interval capacity for heating
Pcych
Degradation co-efficient (**)
Cdh
Power consumption in modes other than active mode
Off mode Thermostat-off mode Standby mode Crankcase heater mode Other items
POFF PTO PSB PCK
Capacity control
Sound power level, indoors/ outdoors
LWA
Emissions of nitrogen oxides
NOx
0,99
0,028 0,020 0,020 0,027
fixed
57 /60 –
kW Cycling interval efficiency
Heating water operating limit
–
temperature
Supplementary heater
kW Rated heat output (*)
kW Type of energy input
kW
kW
COPcyc
–
WTOL
60
Psup
0 eletrical
For air-to-water heat pumps: Rated
–
air flow rate, outdoors
For water-/brine-to-water heat
dB
pumps: Rated brine or water flow
–
mg/kWh rate, outdoor heat exchanger
7300 —
°C kW
m³ /h m³ /h
For heat pump combination heater: Declared load profile
–
Water heating energy efficiency
wh
–
%
Daily electricity consumption
Qelec
–
kWh Daily fuel consumption
Qfuel
–
kWh
Contact details
Glen Dimplex Deutschland GmbH, Am Goldenen Feld 18, 95326 Kulmbach
(*) For heat pump space heaters and heat pump combination heaters, the rated output P rated is equal to the design load for heating Pdesignh , and the rated heat output of a supplementary capacity for heating sup(Tj ).
(**) If Cdh is not determined by measurement nthen the default degradation is C dh = 0,9 (–) not applicable
www.dimplex.de
452170.66.01-EN · FD 0303
EN-19
www.dimplex.de
452170.66.01-EN · FD 0303
EN-20
1772
770
785
1002 825
785
Q725
752
5 Air outlet
825
944
50
694
1 Heating water flow Heat pump outlet 1 1/4″ external thread
2 Heating water return flow Heat pump inlet 1 1/4″ external thread
3 Condensate outflow
4 Electric lines
5 4x internal thread M8 x 15
Direction of air flow Operating side
ca. 50
750
825
691
785
825 785 Q725
5
Air inlet
2
4
1
3
106 90 0
0 68 118 168 242 337 401
English
13 Dimension Drawings
13.1 Dmension Drawing
LI 1422C – 1826C
LI 1422C – 1826C
14 Diagrams
14.1 Characteristic curves for heating operation LI 1422C
Heizleistung in [kW] Heating capacity in [kW] 30 Puissance de chauffage en
[kW] 2-Verdichterbetrieb 2-compressor mode Fonctionnement à 2 compresseurs
25
EN 14511
20
A7 W35…30 1,95 m³/h
A7 W45…40 1,85 m³/h
A7 W55…47 1,10 m³/h
15
10
5
English
Wasseraustrittstemperatur in [°C] Water outlet temperature in [°C] Température
de sortie de l’eau en [°C] 35 45 55
35 45 55 1-Verdichterbetrieb 1-compressor mode Fonctionnement à 1 compresseur
0
-25 -20 -15 -10
-5
0
5
10
15
20
25
30
35
40
45
Lufteintrittstemperatur in [°C] · Air inlet temperature in [°C] · Température d’entrée d’air en [°C]
Leistungsaufnahme in [kW] (incl. Pumpenleistungsanteil)
Power consumption in [kW] (incl. power input to pump)
Consommation de puissance en [kW] (y compris part de consommation de la pompe)
7
55
6
5
45
4
35
55
3
45
2
35
1
0 -25 -20 -15 -10 -5 0 5 10 15 20 25 30 35 40 45
Lufteintrittstemperatur in [°C] Air inlet temperature in [°C] Température
d’entrée d’air en [°C]
Leistungszahl (incl. Pumpenleistungsanteil)
Coefficient of performance (incl. power input to pump
Coefficient de performance (y compris part de consommation de la pompe)
10
9
8
7 6
35
5 4
45
3
55
2
1
0
-25 -20 -15 -10 -5 0 5 10 15 20 25 30 35 40 45
Lufteintrittstemperatur in [°C] Air inlet temperature in [°C] Température d’entrée d’air en [°C]
Druckverlust in [Pa] Pressure loss in [Pa] 16000 Perte de pression en [Pa]
14000
Verflüssiger Condenser Condenseur
12000
10000
8000
6000
4000
2000
0
0,0
0,5
1,0
1,5
2,0
Heizwasserdurchfluss in [m³/h] Heating water flow rate in [m³/h]
Débit d’eau de chauffage en [m³/h]
www.dimplex.de
452170.66.01-EN · FD 0303
EN-21
English
14.2 Characteristic curves for cooling operation LI 1422C
Kühlleistung in [kW] Cooling capacity in [kW] Puissance de refroidissement en
[kW] 30
2-Verdichterbetrieb 2-compressor mode Fonctionnement à 2 compresseurs 25
20
15
10
LI 1422C – 1826C
Wasseraustrittstemperatur [oC] Water outlet temperature in [°C] Température de sortie de l’eau en [°C] Bedingungen · Conditions · Conditions:
Kühlwasserdurchsatz Cooling water flow rate Débit de l’eau de rafraîchissement
A35 WA18 A35 WA7
1,95 m³/h 1,95 m³/h
18
7 18
7 5
1-Verdichterbetrieb 1-compressor mode Fonctionnement à 1 compresseur
0
10
15
20
25
30
35
40
45
50
Lufteintrittstemperatur in [°C] · Air inlet temperature in [°C] ·Température d’entrée d’air en [°C]
Leistungsaufnahme in [kW] (incl. Pumpenleistungsanteil) Power consumption in
[kW] (incl. power input to pump) Consommation de puissance in [kW] (y compris
part de la pompe) 10
18
7
5 18 7
Druckverlust in [Pa] Pressure loss in [Pa] Perte de pression en [Pa] 16000
14000
Verdampfer Evaporator Evaporateur
12000
0 10 15 20 25 30 35 40 45 50 Lufteintrittstemperatur in [°C] Air inlet
temperature in [°C] Température d’entrée d’air en [°C] Leistungszahl (incl.
Pumpenleistungsanteil) Coefficient of performance (incl. power input to pump)
Coefficient de performance (y compris part de consommation de la pompe) 6
5
4
3 18
2 7
1
0 10 15 20 25 30 35 40 45 50 Lufteintrittstemperatur in [°C] Air inlet
temperature in [°C] Température d’entrée d’air en [°C]
10000 8000 6000 4000 2000 0 0,0
0,5
1,0
1,5
2,0
Kühlwasserdurchfluss in [m3/h]
Cooling water flow rate in [m³/h]
Débit de l’eau de rafraîchissement en [m³/h]
EN-22
452170.66.01-EN · FD 0303
www.dimplex.de
LI 1422C – 1826C
English
14.3 Characteristic curves for heating operation LI 1826C
Heizleistung in [kW] Heating capacity in [kW] 40 Puissance de chauffage en [kW] 35
2-Verdichterbetrieb 2-compressor mode Fonctionnement à 2 compresseurs
30
EN 14511
A7 W35…30 2,5 m³/h
25
A7 W45…40 2,4 m³/h
A7 W55…47 1,45 m³/h
20
15
Wasseraustrittstemperatur in [°C] Water outlet temperature in [°C] Température
de sortie de l’eau en [°C] 35 45 55
35 45 55
10
1-Verdichterbetrieb
1-compressor mode
Fonctionnement à 1 compresseur
5
0
-25 -20 -15 -10
-5
0
5
10
15
20
25
30
35
40
45
Lufteintrittstemperatur in [°C] · Air inlet temperature in [°C] · Température d’entrée d’air en [°C]
Leistungsaufnahme in [kW] (incl. Pumpenleistungsanteil)
Power consumption in [kW] (incl. power input to pump)
Consommation de puissance en [kW] (y compris part de consommation de la pompe)
9
8
55
7
45
6
35
5 4 3
55 45
2
35
1
0
-25 -20 -15 -10 -5 0 5 10 15 20 25 30 35 40 45
Lufteintrittstemperatur in [°C]
Air inlet temperature in [°C] Température d’entrée d’air en [°C]
Leistungszahl (incl. Pumpenleistungsanteil)
Coefficient of performance (incl. power input to pump
Coefficient de performance (y compris part de consommation de la pompe)
10
9
8
7
35
6
45
5 4
55
3
2
1
0
-25 -20 -15 -10 -5 0 5 10 15 20 25 30 35 40 45
Lufteintrittstemperatur in [°C] Air inlet temperature in [°C] Température d’entrée d’air en [°C]
Druckverlust in [Pa] Pressure loss in [Pa] 16000 Perte de pression en [Pa]
14000
Verflüssiger Condenser Condenseur
12000
10000
8000
6000
4000
2000
0 0,0 0,5 1,0 1,5 2,0 2,5 3,0 3,5 4,0 4,5 5,0
Heizwasserdurchfluss in [m³/h] Heating water flow rate in [m³/h] Débit d’eau
de chauffage en [m³/h]
www.dimplex.de
452170.66.01-EN · FD 0303
EN-23
English
14.4 Characteristic curves for cooling operation LI 1826C
Kühlleistung in [kW] Cooling capacity in [kW] Puissance de refroidissement en
[kW] 25
2-Verdichterbetrieb 2-compressor mode Fonctionnement à 2 compresseurs 20
15
10
1-Verdichterbetrieb
1-compressor mode
5
Fonctionnement à 1 compresseur
LI 1422C – 1826C
Wasseraustrittstemperatur [oC] Water outlet temperature in [°C] Température de sortie de l’eau en [°C] Bedingungen · Conditions · Conditions:
Kühlwasserdurchsatz Cooling water flow rate Débit de l’eau de rafraîchissement
A35 WA18 A35 WA9
2,5 m³/h 2,5 m³/h
18 9
18 9
0
10
15
20
25
30
35
40
45
50
Lufteintrittstemperatur in [°C] · Air inlet temperature in [°C] ·Température d’entrée d’air en [°C]
Leistungsaufnahme in [kW] (incl. Pumpenleistungsanteil) Power consumption in [kW] (incl. power input to pump) Consommation de puissance in [kW] (y compris part de la pompe) 15
18
10
9
18 5
9
Druckverlust in [Pa] Pressure loss in [Pa] Perte de pression en [Pa] 16000
14000
Verdampfer Evaporator Evaporateur
12000
0 10 15 20 25 30 35 40 45 50 Lufteintrittstemperatur in [°C] Air inlet temperature in [°C] Température d’entrée d’air en [°C] Leistungszahl (incl. Pumpenleistungsanteil) Coefficient of performance (incl. power input to pump) Coefficient de performance (y compris part de consommation de la pompe) 5
4
3
2
18
1
9
0
10 15 20 25 30 35 40 45 50 Lufteintrittstemperatur in [°C] Air inlet
temperature in [°C] Température d’entrée d’air en [°C]
10000
8000
6000
4000
2000
0 0,0 0,5 1,0 1,5 2,0 2,5 3,0 3,5 4,0 4,5 5,0 Kühlwasserdurchfluss in [m3/h]
Cooling water flow rate in [m³/h] Débit de l’eau de rafraîchissement en [m³/h]
EN-24
452170.66.01-EN · FD 0303
www.dimplex.de
LI 1422C – 1826C
14.5 Operating limits diagram heating
65
60
Wasserau (+/- 2 K)
Water outlet (+/- 2 K) So d’eau (+/- 2 K)
English
Heizwassertemperatur [°C] / Heating water temperature [°C] / Température d’eau chauffage [°C] 2 Verdichterbetrieb 2 compressor mode Fonctionement à 2 compresseur 1 Verdichterbetrieb 1 compressor mode Fonctionement à 1 compresseur
55
50
45
40
35
30
25
20
Wassereintri / Water inlet / *Entrée d’eau
15
Die maximalen Vorlauemperaturen werden beim geforderten Mindestheizwasserdurchuss erreicht.
The maximum ow temperatures are achieved at the speci minimum heng water ow.
Les températures départ maximales sont eintes en cas de débit minimum d’eau de chauage donne.
10 -30 -25 -20 -15 -10 -5 0 5 10 15 20 25 30 35 40
Wärmequelleneintrittstemperatur [°C] Heat source inlet temperature [°C]
Température d’entrée de la source de chaleur [°C] Bei Luft/Wasser-Wärmepumpen
stellt die minimale Heizwassertemperatur die Mindest-Rücklauftemperatur dar
For air-to-water heat pumps the minimum heating water temperature is the
minimum return temperature *Sur les pompes à chaleur air / eau, la température
minimale d’eau de chauffage correspond à la température retour minimale
www.dimplex.de
452170.66.01-EN · FD 0303
EN-25
English
14.6 Operating limits diagram cooling LI 1422C
25
20
Wasseraustri (+/- 2 K)
Water outlet (+/- 2 K) So d’eau (+/- 2 K)
LI 1422C – 1826C
Kühlwassertemperatur [°C] / Cooling water temperature [°C] / Température d’eau de rafraîchissement [°C]
15
10
5
Die Angaben gelten bei Einhaltung des geforderten
Mindestkühlwasserdurchflusses. The values are valid for the specified minimum
cooling water flow.
Les données sont valables en cas de respect du débit d’eau de rafraîchissement
donné.
0
10
15
20
25
30
35
40
45
50
Wärmesenkeneintrittstemperatur [°C] Heat sink inlet temperature [°C] Température d’entrée de dissipation thermique [°C]
EN-26
452170.66.01-EN · FD 0303
www.dimplex.de
LI 1422C – 1826C
14.7 Operating limits diagram cooling LI 1826C
25
20
Wasserau (+/- 2 K)
Water outlet (+/- 2 K) So d’eau (+/- 2 K)
English
Kühlwassertemperatur [°C] / Cooling water temperature [°C] / Température d’eau de rafraîchissement [°C]
15
10
5
Die Angaben gelten bei Einhaltung des geforderten
Mindestkühlwasserdurchflusses. The values are valid for the specified minimum
cooling water flow.
Les données sont valables en cas de respect du débit d’eau de rafraîchissement
donné.
0
10
15
20
25
30
35
40
45
50
Wärmesenkeneintrittstemperatur [°C] Heat sink inlet temperature [°C] Température d’entrée de dissipation thermique [°C]
www.dimplex.de
452170.66.01-EN · FD 0303
EN-27
English
15 Integration diagram
15.1 Hydraulic integration diagrams
LI 1422C – 1826C
R2.2 N1
E10.1
º NOTE
The hydraulic integration diagram is an example and intended only as an aid.
The system requires professional and safetyapproved layout by a specialist
planner. All information in the section on installation and the corresponding
safety notes must be observed at all times.
EN-28
452170.66.01-EN · FD 0303
www.dimplex.de
LI 1422C – 1826C
15.2 Hydraulic integration diagrams
English
R2.2 N1
E10.1
º NOTE
The hydraulic integration diagram is an example and intended only as an aid.
The system requires professional and safetyapproved layout by a specialist
planner. All information in the section on installation and the corresponding
safety notes must be observed at all times.
www.dimplex.de
452170.66.01-EN · FD 0303
EN-29
English
15.3 Legend
Isolating valve Safety valve combination Circulating pump Expansion vessel
Room-temperature controlled valve Isolating valve with check valve Isolating
valve with drainage Heat consumer Four-way reversing valve
M
Temperature sensor Flexible connection hose Check valve Three-way mixer Dirt
trap (optional)
Air-to-water heat pump Heat pump manager Buffer tank connected in series Domestic hot water cylinder
E9 E10.1 M13
M15
M16 M22 N1 R1 R2.2 R3
R5
SMF M18
Flange heater domestic hot water Immersion heater Heat circulating pump main
circuit Heat circulating pump for 2nd heating
circuit Auxiliary circulating pump Mixer for 2nd heating circuit Heat pump
manager External wall sensor Demand sensor Domestic hot water sensor
Temperature sensor for 2nd heating cir-
cuit Dirt trap (optional) Domestic hot water circulating pump
LI 1422C – 1826C
EN-30
452170.66.01-EN · FD 0303
www.dimplex.de
LI 1422C – 1826C
16 Declaration of Conformity
You can find and download the current CE conformity declaration at:
https://dimplex.de/li1422c https://dimplex.de/li1826c
English
www.dimplex.de
452170.66.01-EN · FD 0303
EN-31
English
LI 1422C – 1826C
EN-32
452170.66.01-EN · FD 0303
www.dimplex.de
LI 1422C – 1826C
English
www.dimplex.de
452170.66.01-EN · FD 0303
EN-33
Glen Dimplex Deutschland
Head office Glen Dimplex Deutschland GmbH Am Goldenen Feld 18 D-95326 Kulmbach
T +49 9221 709-101 F +49 9221 709-339 info@dimplex.de www.dimplex.de
On site service
After-sales service, technical support and spare partsl. Assistance before and after installation of your equipment
T +49 9221 709-545
F +49 9221 709-924545
Mon – Thu: 7:00 to 17:00
Fri:
7:00 to 15:00
service@dimplex.de
Outside these opening times, in an emergency you can contact our 24/7 hotline.
Request after-sales service on the internet: www.dimplex.de/dimplex-service
References
- Dimplex | Wir heizen, kühlen und lüften die Zukunft.
- Kundendienst und Services | Dimplex
- LI 1422C | Dimplex
- LI 1826C | Dimplex