Blue-White F-462 Flow Meter
Specifications
- Maximum Working Pressure: Maximum Fluid Temperature
- Full Scale Accuracy: +/- 2.5%
- Calibration Fluid: Water, specific gravity 1.0
- Scale Length: 8 (200 mm)
- Environment: Not for direct sunlight exposure
- Maximum Pressure Drop: 2 PSI
- Approximate Shipping Weight: 5 lb. (2.27 kg)
Product Usage Instructions
1. Installation
1.1 Installation Requirements
Ensure the installation area meets the requirements specified in the manual to prevent any issues during operation.
1.2 Tools Required
Gather the necessary tools as listed in the manual before starting the installation process.
1.3 Installation Instructions
Follow the step-by-step installation instructions provided in the manual to set up the F-462 Flow Meter correctly.
1.4 Installing the Polycarbonate Shield
If applicable, carefully install the polycarbonate shield\ following the guidelines in the manual to ensure proper protection.
2. Reading your Flow Meter
Refer to the user manual to understand how to interpret the readings displayed on the Flow Meter accurately.
3. Maintenance and Troubleshooting
Regular maintenance is essential for optimal performance. Follow the maintenance procedures outlined in the manual. In case of issues, refer to the troubleshooting section for guidance.
4. Spare Parts
Information on spare parts and replacements can be found in the dedicated section of the manual for future reference.
5. Warranty
Review the warranty terms provided by the manufacturer to understand coverage and procedures for warranty claims if needed.
FAQ
- Q: Can this Flow Meter be used with chemicals other than water?
- A: While it may be suitable for other chemicals, it is recommended to test and determine compatibility before use as calibration is done for water only.
- Q: What should I do if I encounter electrical installation doubts?
- A: Contact a licensed electrician for assistance to ensure safe and correct electrical setup.
SAFETY INFORMATION
Please read this manual completely before unpacking, installing, and operating this equipment. In particular, pay attention to all dangers, warnings, and precautions, otherwise, it may cause serious injury to the operator or damage to the equipment.
Note: When in doubt regarding your electrical installation, contact a licensed electrician
Introduction
Congratulations on purchasing the F-462 Flow Meter! Your Flow Meter is calibrated and ready for use. The unit is designed to give many years of service. For more information or questions on this product or any of our Industrial products, please visit us at www.blue-white.com
What’s in the box
- Flow meter (1)\ (Flow meter may contain plastic tubing for protection during shipping. Remove before installation.)
- Quick Start Guide
Check all packaging for completeness and inspect for damage before installation.
System Features
- Dual Scale (GPM / LPM), screen printed for easy reading
- Tested and calibrated for clean water applications
- Durable Polysulfone body
- No metal in the fluid path
- Threaded adapters make for simple install on piping
- Optional Polycarbonate Shield
- Unique O-ring design prevents leaks
- Not for use in direct sunlight
- Upward flow, vertical installation only
Application Notes
Although meters may be suitable for other chemicals, Blue-White cannot guarantee their suitability. It is the responsibility of the user to determine the suitability of the flow meter in their application. Flow meters are tested and calibrated for water only.
Ordering Information / Model Number Matrix
In-house NIST Calibration, OEM packaging and silicone oil free options are also available
Engineering Specifications
Flow Meter Specifications
Maximum Working Pressure | 150 PSI (10.3 bar) @ 70 °F (21 °C) |
---|---|
Maximum Fluid Temperature | 200 °F (93 °C) @ 0 Bar |
Full-Scale Accuracy | +/- 2.5% |
Calibration Fluid | Water, specific gravity 1.0 |
Scale Length | 8” (200 mm) |
Environment | Not for direct sunlight exposure |
Maximum Pressure Drop | 2 PSI |
Approximate Shipping Weight | 5 lb. (2.27 kg) |
Materials of Construction
Wetted Components: Non-wetted Components:
Meter Body| Polysulfone| Union Nuts Fiber reinforced nylon
(optional PVC)
Adapters| Polysulfone|
O-ring Seals| Viton® (optional EP)|
Float| PTFE|
Float Stop| Polysulfone|
Optional Shield| Polycarbonate|
Temperature vs. Pressure Graph
Flow Specifications
Dimensions
Installation
Installation Requirements
Before beginning installation, review your system flow and pressure to ensure your F-462 is proper for your system parameters.
Pipe Requirements:
- The flow meter is designed to work best when installed in a perfectly vertical pipe system.
- Ensure piping design prevents any stress on the meter fittings, minimizes vibration, and ensures location with direct visibility and minimal possibility of damage from forcible contact.
- Pipe should be clean and free of debris.
- The connecting pipe should be uniform and not warped.
- Pipe must be properly supported even during maximum water flow conditions.
- Don not install in direct sunlight.
- Use of unionized fittings before and after the flow meter will allow for easier installation and removal for maintenance.
- On/Off solenoid valves and pumps installed before the flow meter should be accompanied by flow regulating/throttling valves, or similar device, to prevent sudden and forcible flows through the flow meter which can cause damage to flow meter components.
- Choose location where pipe will be full at all times.
Tools Required
- PTFE Tape
- Level
Note: Keep flow meter away from pipe glue fumes. Ensure all pipe glue is dry before installation flow meter. Pipe glue solvents will damage meter.
Warning
Always wear protective clothing, face shield, safety glasses and gloves when working on your equipment. Use caution when lifting and mounting equipment. When in doubt, contact factory for assistance
Installation Instructions
- The flow meter must be installed in a vertical plane to ensure accuracy. Misalignment may damage the flow meter and also may cause the o-ring seals to leak. The meterbody material can be damaged by UV rays. Do not install in direct sunlight.
- Use only PTFE tape on the threaded adapters. Pipe dope and glue will damage the meter body and fittings. Or install the flow meter after all glued fittings have dried \and fumes have been purged from the system. Never hold the meter body with pliers or like tools. Union nuts should be hand-tightened only. DO NOT OVER-TIGHTEN!
- Mounts and supports must be sturdy enough to support the plumbing and prevent vibration. Vibration and heavy loads will damage the meter.
- Avoid imposing a sudden burst of flow to the meter. Solenoid valves will damage the meter. Such a burst will cause the float to impact the top float stop with destructive force.
- The Maximum fluid temperature is dependent on the working pressure. High pressure and temperature will damage the meter. (see temperature VS pressure chart)
Polycarbonate Shield Installation Instructions
Use these instructions if you have purchased the optional Polycarbonate Shield Kit, KIT-SHL.
- Unpack the KIT-SHL. The kit includes a shield and two new grooved union nuts. Ensure all components are present and in good shape. The flow meter must be disassembled to install the shield.
- Place meter on flat surface. Unscrew top and bottom union nuts and remove them. Place these union nuts to the side, they will no longer be used.
- With existing adapters in place. Screw one new union nut onto the meter body.
- Place shield over the meter body and onto the new union nut groove.
- With the top adapter in place, put another grooved union nut onto the meter body and shield. (Be sure shield fits into grooves properly without bending)
- Hand tighten union nuts. The flow meter is ready for service.
Reading your F-462 Flow Meter
Avoid imposing a sudden burst of flow to the meter. Solenoid valves may cause the float to impact the top float stop with destructive force. Always read float at top.
Maintenance and Troubleshooting
- The F-462 Flow Meter requires very little maintenance. However, the flow meter may become clogged due to excess debris in the water. If this happens, simply shut of the process pump or valve and remove any pressure from the piping. If isolation valves are installed, shut these to minimize the amount of water that may leak. Locate the nearest unions on piping to allow for the removal of the flow meter. The F-462 Flow Meter may also be removed by unscrewing the flow meter union nuts. Remove the flow meter and clean any debris in the flow meter. Use mild soap and a soft bristle brush.
- Reinstall the flow meter and test. If the float was removed during the cleaning process, ensure the float was reinstalled properly. The float is wider at the top.
- If flow meter requires NIST Calibration Certification, please contact the factory for this service.
Spare Parts
Item| Model No.| Product Name| Qty.
Req.
---|---|---|---
1| F-452004N| Union Nut (Nylon)| 2
2| F-452330N| 2.0” Adapter FNPT (PSF)| 2
3| F-452002| Float Stop (PSF)| 2
4| F-452043N| O-Ring (Viton)| 2
| F-452043NE| O-ring (EP)| 2
5| –| Float (PTFE) (contact factory)| 1
6| –| Meterbody (PSF) (contact factory)| 1
WARRANTY
LIMITED WARRANTY
Your new Flow Meter is a quality product and is warrantied for 12 months from date of purchase (proof of purchase is required). The unit will be repaired or replaced at our discretion. Failure must have occurred due to defect in material or workmanship and not as a result of operation of the product other than in normal operation as defined in the manual. Warranty status is determined by the serial label and the sales invoice or receipt. The serial label must be on the unit and legible. The warranty status of the unit will be verified byBlue-White or a factory authorized service center.
WHAT IS NOT COVERED
- Wear items.
- Unit removal, or re-installation, and any related labor charge.
- Freight to the factory, or service center.
- Units that have been tampered with, or in pieces.
- Damage to the unit that results from misuse, carelessness such as chemical spills on the enclosure, abuse, lack of maintenance, or alteration which is out of our control.
- Units damaged by faulty wiring, power surges or acts of nature.
PROCEDURE FOR IN WARRANTY REPAIR
Contact the factory to obtain a RMA (Return Material Authorization) number. Carefully pack the unit to be repaired. Please enclose a brief description of the problem as well as the original invoice or sales receipt, or copy showing the date of purchase. Prepay all shipping costs. COD shipments will not be accepted. Warranty service must be performed by the factory or an authorized service center. Damage caused by improper packaging is the responsibility of the sender. When In-Warranty repair or replacement is completed, the factory pays for return shipping to the dealer or customer.
PRODUCT USE WARNING
Blue-White products are manufactured to meet the highest quality standards in the industry. Each product instruction manual includes a description of the associated product warranty and provides the user with important safety information. Purchasers, installers, and operators of Blue-White products should take the time to inform themselves about the safe operation of these products. In addition, Customers are expected to do their own due diligence regarding which products and materials are best suited for their intended applications. Blue-White is pleased to assist in this effort but does not guarantee the suitability of any particular product for any specific application as Blue-White does not have the same degree of familiarity with the application that the customer/end-user has. While Blue-White will honor all of its product warranties according to their terms and conditions, Blue- White shall only be obligated to repair or replace its defective parts or products in accordance with the associated product warranties. BLUE-WHITE SHALL NOT BE LIABLE EITHER IN TORT OR IN CONTRACT FOR ANY LOSS OR DAMAGE WHETHER DIRECT, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL,\ ARISING OUT OF OR RELATED TO THE FAILURE OF ANY OF ITS PARTS OR PRODUCTS OR OF THEIR NONSUITABILITY FOR A GIVEN PURPOSE OR APPLICATION.
CHEMICAL RESISTANCE WARNING
Blue-White offers a wide variety of wetted parts. Purchasers, installers, and operators of Blue-White products must be well informed and aware of the precautions to be taken when injecting or measuring various chemicals,\ especially those considered to be irritants, contaminants or hazardous. Customers are expected to do their own due diligence regarding which products and materials are best suited for their applications, particularly\ as it may relate to the potential effects of certain chemicals on Blue-White products and the potential for\ adverse chemical interactions. Blue-White tests its products with water only. The chemical resistance information included in this instruction manual was supplied to Blue-White by reputable sources, but Blue- White is not able to vouch for the accuracy or completeness thereof. While Blue-White will honor all of its product warranties according to its terms and conditions, Blue-White shall only be obligated to repair or replace its defective parts or products in accordance with the associated product warranties. BLUE-WHITE SHALL NOT BE LIABLE EITHER IN TORT OR IN CONTRACT FOR ANY LOSS OR DAMAGE, WHETHER DIRECT, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL, ARISING OUT OF OR RELATED TO THE USE OF CHEMICALS IN CONNECTION WITH ANY BLUE- WHITE PRODUCTS.
Users of electrical and electronic equipment (EEE) with the WEEE marking per Annex IV of the WEEE Directive must not dispose of end of life EEE as unsorted municipal waste, but use the collection framework available to them for the return, recycle, recovery of WEEE and minimize any potential effects of EEE on the environment and human health due to the presence of hazardous substances. The WEEE marking applies only to countries within the European Union (EU) and Norway. Appliances are labeled in accordance with European Directive 2002/96/EC. Contact your local waste recovery agency for a Designated Collection Facility in your area.
5300 Business Drive, Huntington Beach, CA 92649
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>