GRIVEN AL8365 Lighting Equipment User Manual
- September 28, 2024
- GRIVEN
Table of Contents
- GRIVEN AL8365 Lighting Equipment
- Product Usage Instructions
- Frequently Asked Questions
- Specification
- Dimension
- Important notices
- Fixing
- Connection
- DMX Configurations
- Splitter Connections
- DMX Chart
- 1
- 2
- 3
- 4
- 5
- 6
- 1| 1| 0%-100% Warm white| 0-255|
- 2| 2| 0%-100% Cold white| 0-255|
- 3
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
GRIVEN AL8365 Lighting Equipment
Product Specifications:
-
Model: Underwater MK3 Line
-
Power Consumption: Micro Waterled MK3 AL8365 – 9W RGBW / 9W DW/W, Mini Waterled MK3 AL8369 – 25W RGBW / 25W DW/W, Waterled MK3 AL8373 – 39W RGBW / 48W DW/W, Maxi Waterled MK3 AL8377
65W RGBW / 86W DW/W -
Power Supply: 24Vdc
-
Electrical Class: III
-
Weight: Micro Waterled MK3 – 2.3 Kg / 5.1 lb, Mini Waterled MK3 – 3.7 Kg / 8.2 lb, Waterled MK3 – 4.9 Kg / 10.8 lb, Maxi Waterled MK3 – 6.0 Kg / 13.23 lb
-
Operating Temperature: Operating temperatures * (not specified)
-
IP Rating: IP68 (-3M)
-
IK Rating: IK10
-
Size: Micro Waterled MK3 – 232.50 x 155 x 66.2 mm, Mini Waterled MK3 – 172.5 x 89.45 x 215 mm, Waterled MK3 – 155 x 89.45 x 298 mm, Maxi Waterled MK3 – 315 x 89.45 x 298 mm
Product Usage Instructions
Installation:
- The product must be installed in accordance with applicable national and local electrical and construction codes by a person familiar with the product’s construction and operation.
- Install the product underwater and protect it against freezing.
Precautions:
- Do not stay at the operating light source.
- Use an overvoltage protection device on the electrical system to prevent damage from excess voltage.
- Disconnect power before installing or servicing the product to avoid electrical shock.
- Do not handle the unit with wet hands or in wet environments.
- Ensure proper cables and connectors are used with correct section and length according to power consumption.
Maintenance:
- Apply to qualified staff for any maintenance service not described in the manual.
- If the external cable is damaged, replace it only with manufacturer-approved personnel to avoid hazards.
Positioning:
- Position the luminaire so that prolonged observation at a distance of less than 2 meters is not expected.
Frequently Asked Questions
- Q: Can I exceed the maximum quantity of fixtures per line?
- A: No, it is recommended to avoid power surges by not exceeding the specified maximum quantity of fixtures per line.
- Q: What should I do if the external cable is damaged?
- A: If the external cable is damaged, it must only be replaced by the manufacturer, its assistance service, or equivalent qualified personnel to avoid hazards.
Specification
| Micro Waterled MK3| Mini Waterled MK3| Waterled
MK3| Maxi Waterled MK3
---|---|---|---|---
Code / Codice| AL8365| AL8369| AL8373| AL8377
Power consumption Consumo di energia| 9W – RGBW
9W – DW/W
| 25W – RGBW
25W – DW/W
| 39W – RGBW
48W – DW/W
| 65W – RGBW
86W – DW/W
Power supply Alimentazione elettrica| 24 Vdc
Electrical class Classe elettrica| III
Weight / Peso| 2.3 Kg / 5.1 lb| 3.7 Kg / 8.2 lb| 4.9 Kg / 10.8 lb| 6.0
Kg / 13.23 lb
Operating temperature Temperatura di funzionamento| ta max = 50° C /
ta max = 122° F
IP rating / Grado IP| IP68 (-3M)
IK rating / Grado IK| IK10
WARNING ! The product must only be operated underwater and must be protected against freezing in
Dimension
Important notices
- This product must be installed in accordance with applicable national and local electrical and construction codes by a person familiar with the construction and operation of the product and the hazards involved. Failure to comply with the following installation instructions may result in death or serious injury.
- Do not stare at the operating light source.
- The fi xture might be damaged by excess voltage. The installation of an overvoltage protection device on the electrical system (SPD) is recommended for reduce the risk of damage.
- The use of an adequate magnetothermic switch along the power supply line is recommended.
- Connect the fi xtures to each other only when disconnected from mains.
- Never leave cables and connectors unconnected or unprotected for long periods.
- Disconnect power before installing or servicing to avoid electrical shock.
- Disconnect power before any connection operation.
- Check voltage and frequency before powering the fi xture. Do not exceed fi xture specifi ed voltage.
- Do not handle the unit with wet hands or in wet environments.
- Apply to qualifi ed staff for any maintenance service not described in this instructions manual.
- Do not exceed the maximum quantity of fi xtures per line in order to avoid power surges.
- Before powering the unit, ensure to use cables and connectors with proper section and length, according to its power consumption.
- Fix the projector by using screws, hooks or other adequate supports that can bear its weight.
- If the external fl exible cable of this appliance is damaged, it must only be replaced by the manufacturer, its assistance service or equivalent qualifi ed personnel in order to avoid hazards.
- Integrated temperature control, the projector reduces power when Ta >35°C.
- The luminaire should be positioned so that prolonged observation of the luminaire at a distance of less than 2 meters (6.56 ft) is not expected.
CAUTION: Prolonged staring at the LED source should be avoided by placing the fixture in a proper position.
- WARNING! Fixing and connecting operations must mandatorily be carried out by qualified personnel only !
- WARNING! Make sure that power supply is off before connecting or disconnecting fixtures !
- The possibility of reusing some electrical parts of the device is subject to the total responsibility of the user. The label shows the symbol indicated in Legislative Decree n.49 of 14 March 2014 which transposes Directive 2012/19 / EU, which indicates the need to dispose of the product in separate waste, specifically in electrical waste. and electronic. Refer to the waste collection center located in your area
- Replaceable control gear by a professional
- Replaceable (LED only) light source by a professional
Fixing
Vertical beam-aiming
Connection
DMX Configurations
Single Chain configuration
DMX cable type:
- 2×0.34 mm2 impedance 110Ω, capacity 43pF/m, resistance 50Ω/Km.
- Use a DMX repeater in case the total DMX LINE length exceeds 300m (1000 ft)
Including the projector cable
A| Power Input (24 Vdc)|
---|---|---
B| DMX/RDM Controller|
C| Linea WaterLed MK3|
D| DMX Cable| Code: AL0512
E| Junction Box (Not Included) Minimum IP Rating: IP67 (only external
connections to water) Junction Box
MONOCABLE 5-Pole
Brown| VDC +
Blue| VDC –
Red| Data +
Black| Data –
White| GND
MONOCABLE 4-Pole
Num.1| VDC +
Num.2| VDC –
Num.3| Data +
Num.4| Data –
Connection Detail – Monocable 5-pole Connection
Connection Detail – Monocable 4-pole Connection
Connection Detail – Separate Cables Connection
Connection Detail – Separate Cables Connection
Splitter Connections
2 channels example
4 channels example
NOTE: The possible use of one or more splitters depends on the type of project to be developed. For more details consult GRIVEN
PSU Dimensioning
| MICRO WATERED MK3| MINI WATERED MK3|
WATERLED MK3| MAXI WATERLED MK3
---|---|---|---|---
RGBW| Driver 120W – MAX.12 UNITS| Driver 150W – MAX.5 UNITS| Driver 150W –
MAX.3 UNITS| Driver 150W – MAX.2 UNITS
RGBW| | Driver 240W – MAX.9 UNITS| Driver 240W – MAX.6 UNITS| Driver 240W –
MAX.3 UNITS
WHITE| | Driver 150W – MAX.5 UNITS| Driver 150W – MAX.2 UNITS| Driver 150W –
MAX.1 UNITS
WHITE| | Driver 240W – MAX.9 UNITS| Driver 240W – MAX.4 UNITS| Driver 240W –
MAX.2 UNITS
IR Remote Control operations
The fixture must be configured only by using the AL1321 IR remote control ( sold separately ) or via any DMX-RDM compatible controller
Not valid for MICRO WATER LED MK3
Non valido per MICRO WATER LED MK3
- WARNING ! In this mode, no other DMX control device must be present along the line.
- Only on wireless fixtures
DMX Chart
RGBW
Mode | Channel | Function | Value |
---|
1
IR=4
| 1| 0-100% Red| 0-255
2| 0-100% Green| 0-255
3| 0-100% Blue| 0-255
4| 0-100% White| 0-255
2
IR=5
| 1| 0-100% Red| 0-255
2| 0-100% Green| 0-255
3| 0-100% Blue| 0-255
4| 0-100% White| 0-255
5| 0-100% Dimmer| 0-255
3
IR=6
| 1| 0-100% Red| 0-255
2| 0-100% Green| 0-255
3| 0-100% Blue| 0-255
4| 0-100% White| 0-255
5
| 0% Dimmer| 0-5
0%-100% Dimmer| 6-250
100% Dimmer| 251-255
6
| No Strobo| 0-5
0-100% Strobo| 6-250
100% Strobo| 251-255
4
IR=7
| 1| 0-100% Red| 0-255
2| 0-100% Green| 0-255
3| 0-100% Blue| 0-255
4| 0-100% White| 0-255
5
| NO FUNCTION| 0-5
2700K| 6-7
2700K-3000K| 8-40
3000K| 41-42
3000K-3500K| 43-75
3500K| 76-77
3500K-4000K| 78-110
4000K| 111-112
4000K-4500K| 113-145
4500K| 146-147
4500K-5000K| 148-179
5000K| 180-181
5000K-5500K| 182-214
5500K| 215-216
5500K-6000K| 217-249
6000K| 250-255
6| 0-100% Dimmer| 0-255
5
IR=8
| 1| 0-100% Red| 0-255
2| 0-100% Red fine-tuning| 0-255
3| 0-100% Green| 0-255
4| 0-100% Green fine tuning| 0-255
5| 0-100% Blue| 0-255
6| 0-100% Blue fine-tuning| 0-255
7| 0-100% White| 0-255
8| 0-100% White fine-tuning| 0-255
Mode| Channel| Function| Value
---|---|---|---
6
IR=9
(Default)
| 1| 0-100% Red| 0-255
2| 0-100% Green| 0-255
3| 0-100% Blue| 0-255
4| 0-100% Calibrated White (affects RGB channels)| 0-255
Note: in the absence of a DMX signal the LEDs will remain OFF.
DW (Dynamic White)
Mode| Channel| Function| Value|
---|---|---|---|---
1| 1| 0%-100% Warm white| 0-255|
IR=2|
| | |
(Default)| 2| 0%-100% Cold White| 0-255|
| 1| 0%-100% Warm white| 0-255|
2| 2| 0%-100% Cold white| 0-255|
IR=3|
3| 0%-100% dimmer| 0-255|
|
| 1| 0%-100% Warm white| 0-255|
3
| 2| 0%-100% Warm white fne| 0-255|
IR=3| 3| 0%-100% Cold white| 0-255|
| 4| 0%-100% Cold White fne| 0-255|
Note: in absence of DMX signal the LEDs will remain ON.|
Monochromatic version
Channel | Function | Value |
---|---|---|
1 | 0%-100% dimmer | 0-255 |
Note: in absence of DMX signal the LEDs will remain ON.
RDM functions
- When operating in DMX mode the fixture can accept the following RDM commands:
- Discovery: upon request of the RDM controller, the fixture will signal its own presence (the RDM controller will display the fixture on a list).
- DMX address reading and setting.
- Channels number reading and setting.
- On / Off identification: this command is used to identify the fixture you want to get access to (the identification happens by switching on all the LEDs at full intensity).
- Manufacturer: it displays the name of the manufacturer (Griven).
- Model description: it displays the fixture’s model.
- Software version description: it displays the current version of the firmware.
- Temperature: it displays the LEDs operating temperature value.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>