amazonbasics B073Q48YGF, B073Q3BSPG Surge Protector Battery Power Backup User Guide

June 3, 2024
AmazonBasics

B073Q48YGF, B073Q3BSPG Surge Protector Battery Power Backup
User Guide
amazonbasics B073Q48YGF, B073Q3BSPG Surge Protector Battery
Power BackupStandby UPS 600VA 360W, 8 Outlets,
Standby UPS 800VA 450W, 12 Outlets
UPS De Respaldo, 600VA 360W, 8 Tomas,
UPS De Respaldo, 800VA 450W, 12 Tomas
Alimentation Sans Interruption (ASI) 600 VA 360 W, 8 Prises,
Alimentation Sans Interruption (ASI) 800 VA 450 W, 12 Prises
B073Q48YGF, B073Q3BSPG

Description

amazonbasics B073Q48YGF, B073Q3BSPG Surge Protector Battery Power Backup -
Figure 1

Basic Operation

  1. Battery and Surge Protected Outlets
    The unit has several battery and surge protected outlets (4 for 600VA and 6 for 800VA unit) to ensure temporary uninterrupted operation of your equipment during a  power failure. (Do not plug a laser printer, paper shredder, copier, space heater, vacuum, sump pump or other large electrical device into the “Battery and Surge  Protected Outlets.” The power demands of these devices will overload and possibly damage the unit.).

  2. Full-Time Surge Protection Outlets
    The unit has several surge suppression outlets (4 for 600VA and 6 for 800VA unit) to provide surge and line noise protection.

  3. Power Switch
    To turn the UPS on, press the power button for approximately 2 seconds – you will hear a constant tone (1 second) – and release after a short beep.
    To turn the UPS off, press the power button for approximately 2 seconds – you will hear a constant tone (1 second) – and release after two short beeps.
    Quickly press the POWER button twice can turn off or turn on the audible Alarm. The default setting is for the Alarm On.
    To turn the alarm off, press the power button twice. You will hear two short beeps when the alarm is turned off.
    To turn the alarm back on, press the power button twice. You will hear a short beep when the alarm is turned on.
    *When the alarm is turned off, no audible notification when the UPS reaches a (low) battery state.

  4. Power On Indicator (green)
    This LED is illuminated when the utility power is normal and the UPS outlets are providing power, free of surges and spikes. When In the event of a complete power  loss, severe brownout, or over-voltage, the UPS will turn to battery mode and the LED will flash.
    Please refer to the following “Definitions for Illumination LED Indicators” for more information.

  5. Circuit Breaker
    Located on the side of the UPS, the circuit breaker serves to provide overload and fault protection.

  6. USB Port to PC
    The USB port allows connection and communication between the USB port on the personal computer and the UPS unit. The UPS communicates its status to the Power Management Software.

  7. Outlets Designed for AC Adapters
    The UPS unit has several widely-spaced outlets (2 for 600VA and 4 for 800VA unit), so AC power adapters can be plugged into the UPS without overlapping or blocking  adjacent outlets.

Important Safety Warnings

(SAVE THESE INSTRUCTIONS)

  • This manual contains important safety instructions. Please read and follow all instructions carefully during installation and operation of the unit. Read this manual  thoroughly before attempting to unpack, install, or operate your UPS.
  • CAUTION! To prevent the risk of fire or electric shock, install in a temperature and humidity controlled indoor area free of conductive contaminants. (Please see  specifications for acceptable temperature and humidity range).
  • CAUTION! To reduce the risk of electric shock, do not remove the cover. There are no user serviceable parts inside.
  • CAUTION! Hazardous live parts inside can be energized by the battery even when the AC input power is disconnected.
  • CAUTION! The UPS must be connected to an AC power outlet with fuse or circuit breaker protection. Do not plug into an outlet that is not grounded. If you need to  de-energize this equipment, turn off and unplug the unit.
  • CAUTION! To avoid electric shock, turn off the unit and unplug it from the AC power source before installing a computer component.
  • CAUTION! Not for use in a computer room as defined in the Standard for the Protection of Electronic Computer/Data Processing Equipment, ANSI/NFPA 75.
  • CAUTION! To reduce the risk of fire, connect only to a circuit provided with 20 amperes maximum branch circuit over current protection in accordance with the  National Electric Code, ANSI/NFPA 70.
  • CAUTION! Risk of explosion if battery is replaced by an incorrect type. Batteries shall be installed by service personnel, and the replacement of batteries with a suitable  recommended type. Dispose of used batteries according to the instructions.
  • CAUTION! Do not dispose of batteries in a fire. The batteries may explode.
  • CAUTION! Do not open or mutilate batteries. Released electrolyte is harmful to the skin and eyes. It may be toxic.
  • DO NOT USE FOR MEDICAL OR LIFE SUPPORT EQUIPMENT! AmazonBasics does not sell products for life support or medical applications. Do not use in any circumstance that would affect operation and safety of life support equipment, any medical applications or patient care.
  • DO NOT USE WITH OR NEAR AQUARIUMS! To reduce the risk of fire or electric shock, do not use with or near an aquarium. Condensation from the aquarium  can cause the unit to short out.
  • DO NOT USE THE UPS ON ANY TRANSPORTATION! To reduce the risk of fire or electric shock, do not use the unit on any transportation such as airplanes or  ships. The effect of shock or vibration caused during transit and the damp environment can cause the unit to short out.
  • WARNING! This product contains chemicals known to State of California to cause cancer and birth defects or other reproductive harm.
  • CAUTION! Not for use in a computer room as defined in Standard for the Protection of Electronic Computer/Data Processing Equipment, ANS/NFPA 75.

Installing Your UPS System

Unpacking
Inspect the UPS upon receipt. The box should contain the following: (a) UPS unit (b) User’s manual (c) USB Cable
*Power Management software is available on our website. Please visit amazon.com and go to the product page for free download.
How To Determine The Power Requirements Of Your Equipment

  1. Ensure that the equipment plugged into the UPS does not exceed the UPS unit’s rated capacity (600VA / 360W for AmazonBasics Standby UPS 600VA, 800VA/450W  for AmazonBasics Standby UPS 800VA). If the rated capacities of the unit are exceeded, an overload condition may occur and cause the UPS unit to shut down or the  circuit breaker to trip.
  2. There are many factors that can affect the amount of power that your electronic equipment will require. For optimal system performance, keep the load below 80% of  the unit’s rated capacity.

Hardware Installation Guide

  1. Your new UPS may be used immediately upon receipt. However, after receiving a new UPS, to ensure the battery’s maximum charge capacity, it is recommended that you  charge the battery for at least 8 hours. Your UPS is equipped with an auto-charge feature. When the UPS is plugged into an AC outlet, the battery will automatically  charge whenever it’s turned on or turned off.

  2. With the UPS unit turned off and unplugged, connect your equipment requiring battery backup into the battery power supplied outlets. Plug the other peripheral equipment (printer, scanner, speakers) into the full-time surge protection outlets. Do not plug a laser printer, paper shredder, copier, space heater, vacuum, sump pump  or other large electrical device into the “Battery and Surge Protected Outlets”. The power demands of these devices will overload and possibly damage the unit.

  3. Plug the UPS into a 2 pole, 3 wire grounded receptacle (wall outlet). Make sure the wall branch outlet is protected by a fuse or circuit breaker and does not service  equipment with large electrical demands (e.g. air conditioner, refrigerator, copier, etc.). The warranty prohibits the use of extension cords, outlet strips, and surge strips in  conjunction with the UPS.

  4. Press the power switch to turn the unit on. The Power On indicator will illuminate green and the unit will “beep” twice.

  5. If an overload is detected, an audible alarm will be sounded and the unit will emit long beep. To correct this, turn the UPS off and unplug at least one piece of equipment  from the battery power supplied outlets. Make sure the circuit breaker is depressed and then turn the UPS on.

  6. To maintain optimal battery charge, leave the UPS plugged into an AC outlet at all times.

  7. To store the UPS for an extended period of time, cover it and store with the battery fully charged. While in storage, recharge the battery every three months to ensure  battery life.

  8. For pluggable equipment, the socket-outlet shall be installed near the equipment and shall be easily accessible.

  9. Do not lay the UPS on its side and please follow the direction as below to mount the UPS to ensure the battery life.

amazonbasics B073Q48YGF, B073Q3BSPG Surge Protector Battery Power Backup -
Figure 3

Definitions For Illuminated LED Indicators

Power ON Alarm CONDITION
On Off Normal

Flash when
Beeps| Beeps twice every
30 seconds| Utility Failure – Battery Mode
The UPS is providing power to battery and surge protected outlets from its battery.
Flash when
Beeps| Rapid  Beeping
every 1/2 second| Utility Failure – Low Battery
The UPS is providing battery power. Rapid beeping indicates the unit will run out of power shortly
On| Constant tone| Overload – Occurs when connected equipment exceeds the listed capacity of the UPS. Turn the UPS off, unplug at least one piece of equipment from battery outlets, reset the circuit breaker and turn the unit on.
Off| Constant tone| Charge Fault – In line mode, the battery charging voltage is too high or too low.
Off| Constant tone| Utility Failure – The frequency is beyond 47-63 Hz. The UPS will not turn on in line mode.

Technical Specifications

Model Standby UPS 600VA Standby UPS 800VA
Capacity 600 VA / 360 W 800 VA / 450 W
Input Voltage on Utility 96V typical – 140V typical
Input Frequency 50/60 ± 3 Hz (Auto-sensing)
Nominal Input Voltage 120 VAC
On-Battery Output Voltage 120 VAC ± 8 %
On-Battery Output Frequency 50 Hz / 60 Hz ± 1 %
Transfer Time 8 ms Typical
Max. Load for UPS Outlets 600 VA / 360 W I 800 VA/450 W
Model Standby UPS 600VA Standby UPS 800VA
--- --- ---

Max. Load for Full-Time Surge
Protection outlets| 10 Amps
On-Battery Output Wave Form| Simulated Sine Wave
Operating Temperature| + 32 °F to 104 °F / 0 °C to 40 °C
Operating Relative Humidity| 0 to 95% non-condensing
Size (L x W x H)| 10.7 x 3.1 x6.1 in.
(272 x 80 x 155 mm)| 12.2 x 3.1 x7.0 in.
(310 x 80 x 178 mm)
Net Weight| 6.53 lbs (2.96 kg)| 9.23 lbs (4.18 kg)
Typical Battery Recharge Time| 8 hours typical from total discharge
Typical Battery Life| 3 to 6 years, depending on number of discharge/
recharge cycles
Recommended Battery| Sealed Maintenance Free Lead Acid Battery
Safety Approvals| UL, cUL, FCC Class B, ICES-003: Class B, CEC

System Function Block Diagram

amazonbasics B073Q48YGF, B073Q3BSPG Surge Protector Battery Power Backup -
Figure 4

Troubleshooting

Problem Possible Cause Solution

Full-time surge protection outlets stop providing power to equipment. Circuit breaker button is projecting from the side of the unit.| Circuit breaker has
been tripped due to an overload.| Turn the UPS off and unplug at
least one piece of equipment. Wait 10 seconds, reset the circuit breaker by pressing the button, and then turn the UPS on.
The UPS does not perform expected runtime.| Battery not fully charged.| Recharge the battery by leaving the UPS plugged in.
Battery is worn out.| Please contact Amazon about replacement batteries.
The UPS will not turn on.| The on/off switch is designed to prevent damage from rapidly turning it off and on.| Turn the UPS off. Wait
10 seconds and then turn the UPS on.
The unit is not
connected to an AC outlet.| The unit must be connected to a 110/120 V 50/60 Hz outlet.
The battery is worn out.| Please contact Amazon about replacement batteries.
Mechanical problem.| Please contact Amazon.
The frequency is
outside of the operating range of 47-63 Hz.| Turn the UPS off. Make sure the frequency range is within
47-63 Hz. Or you can turn the UPS on in battery mode.
Problem| Possible Cause| Solution
---|---|---
Power Management Software is inactive (all icons are gray).| The USB cable is not connected or connected well.| Use the USB cable which comes along with the unit and connect the UPS unit to an open USB port on the computer.
The USB cable is connected to a bad USB port.| Check for a different USB port
and plug the cable in.
The unit is not turned on.| Shutdown your computer and turn the UPS off.
Wait 10 seconds and turn the UPS back on. This should reset the unit.

FCC Information
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide  reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and  used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a  particular installation.
If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to  try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

Changes or modifications not expressly approved by the party responsible for compliance may cause interference and void the user’s authority to operate the equipment. This  device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this  device must accept any interference received, including interference that may cause undesired operation.

IC Regulatory Statement

This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference,  and (2) this device must accept any interference, including interference that may cause undesired operation of the device.

Feedback and Help

Love it? Hate it? Let us know with a customer review.
AmazonBasics is committed to delivering customer-driven products that live up to your high standards. We encourage you to write a review sharing your experiences with the  product.

amazon.com/review/review‑your‑purchases#
amazon.com/gp/help/customer/contact‑us

**amazon.com/AmazonBasics
MADE IN CHINA**

Documents / Resources

| amazonbasics B073Q48YGF, B073Q3BSPG Surge Protector Battery Power Backup [pdf] User Guide
B073Q48YGF, B073Q3BSPG, B073Q48YGF Surge Protector Battery Power Backup, B073Q3BSPG Surge Protector Battery Power Backup, Surge Protector Battery Power Backup, Protector Battery Power Backup, Surge Protector, Battery Power Backup
---|---

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

AmazonBasics User Manuals

Related Manuals