Product Usage Instructions
You can download the BFOUR app from the App Store or Google Play.
- Turn on your phone’s Bluetooth and GPS.
- Open the BFOUR app.
- Turn on the Add Device function to find your BFOUR device.
- Pair your smartphone with the BFOUR device.
- Download and install the BFOUR App.
- Press the power button until the LCD lights up with a single beep to power on the booster station.
- Charge the booster station using a Type-C charger.
- Remove the probes from the booster station. The temperature will display on the screen, indicating pairing with the probes.
- Connect your smart device to the booster station via Bluetooth. The screen will display temperature and signal icons once paired.
- Handle the device and probes with care to avoid any damage. Keep away from water sources to prevent damage to internal components.
The app provides various options for monitoring and setting temperatures. You can also customize settings for personalized usage.
FAQ
- Q: How do I charge the device?
- A: The booster station can be charged using a Type-C charger. Ensure it is fully charged before use.
- Q: Can I use the thermometer without the app?
- A: While the app enhances functionality, basic temperature readings can still be obtained without pairing with the app.
Overview
Specifications
Model: | BF-60 |
---|---|
Internal Temperature: | 32℉ to 212℉(0℃ to 100℃) |
Temperature Accuracy: | ±1℃/±1.8℉ |
Wireless Connection Range: | 60m/196FT |
Probes Charging Time: | 2 Min |
Booster Charging Time: | 3 H |
Probe Usege Time: | 60 H |
Booster Usege Time: | 40 H |
Probe Material: | SUS304,Zirconia |
Waterproof Grade: | IP67 |
Battery: | 500 mAh |
Package: | Probe x2, Booster x1, |
Type-c cable x1, User Manual x1
Compatible System:| A smartphone or tablet running ios 8.0
(or above) or Android 4.3(or above).
Feature
- Booster: The booster receives temperature signals from the probes and transmits them to the display and a smart device. It also serves as a power source to charge the probes.
- Probes: the probes are inserted into the meat to measure its internal temperature.
- Probe Battery: When the probes are being charged, the screen will display “charging for 2 minutes.” Once the charging process is complete, the screen will show “full charge.”
- Booster Battery Power Indicator: When the display battery icon is low, it indicates that the booster is low on power and needs to be charged.
- Connection Indicator: if the probes lose connection to the booster, it will sound an alarm. Press the power button twice to deactivate the alarm.
- Probe Safety Notch: To avoid damage, insert probe into meat past the safety notch.
- Power Button: The power button is not only used to turn the booster on and off, but also to deactivate the alarm sound.
- Sensors: The temperature sensors can monitor the internal meat temperature up to 212°F (100°C).
Connect Your Device with the BFOUR APP
- You can download this app by searching ” BFOUR ” in the App Store or Google Play.
Pairing with your smartphone
- Turn on your phone’s Bluetooth and GPS
- Open the BFOUR app
- Turn on the “Add Device” to find the device
- Pair it with your phone
Notice
- Ensure GPS and Bluetooth on your phone are turned on; it will affect your connection to the device.
- Our thermometers can’t connect to more than one phone at a time, but our app can connect to more than one thermometer at a time.
- Q: Why is it necessary to enable GPS on my Android device when adding a BF Home device?
- A: Enabling GPS is a requirement set by the Android system when pairing a Bluetooth device. However, once the device is added, you can turn off the GPS. In contrast, iOS does not mandate GPS activation during the pairing process for Bluetooth devices.
Usage
-
Step 1: Download and install the ” BFOUR ” App.
-
Step 2: Press the power button until the LCD lights up with a single beep. This indicates that the booster station is powered on.
-
Step 3: Charge the booster station using a type-C charger. Remove the probes from the booster station. The temperature will display on the screen, indicating that the booster station is paired with the probes.
Connect your smart device to the booster station via Bluetooth. The screen will display the temperature and signal icons, indicating that your device is paired with the booster station. -
Step 4: Start Cooking
-
- Insert the probes deeply into the meat, ensuring that the notch on the probes is fully covered by the meat.
-
- Set your desired meat temperature or select the meat type and desired doneness within the BFOUR App.
-
- Once the internal temperature reaches your target temperature, an alarm will sound from the booster station and the app. Press the power button to disarm the alarm. The booster station and alarm clock icons will flash. The flashing will stop once the temperature falls below the target temperature or when another target temperature is set.
-
Attention
- If the temperature exceeds 100°C/212°F, the booster station will sound an alarm, and the screen will display a flashing exclamation mark icon. In such cases, you should immediately stop heating the meat to avoid damaging the probes.
- If the black and white probe colors are not positioned correctly on the booster, the temperature will not be displayed on the booster screen. If you are only using one probe, please place the other probe back in its corresponding position on the booster.
- The advertised 196ft (60m) distance measurement is based on an accessibility test. However, in real-world scenarios, the actual distance may be shorter than 196ft (60m) due to obstacles or other factors.
- When inserting the probes into the meat, position the booster station as close as possible to the cooking device, and monitor the screen for temperature display. If the screen remains blank or an alarm sounds, it indicates a broken connection between the probes and the booster station. In such cases, move the booster station closer to the probes until the temperature is displayed correctly and the alarm clears.
- If the device is in standby mode, the booster will automatically shut down and you will need to turn it back on when you use the device.
- If the device cannot connect to the phone or if the probe cannot be detected for charging, please contact us via email.
Caution
-
Due to the presence of sophisticated and delicate electronics within the probes, it is crucial to always insert the probes deeply into the meat so that the notch on the probes is fully covered. This will prevent exposure to extremely high temperatures that could potentially damage the electronics.
-
Avoid using this device in the microwave as it is not designed for such use.
-
After use, refrain from touching the probes directly. To prevent burns, it is recommended to wear insulated gloves when handling the probes.
-
After each use, clean the probes using a clean kitchen towel or rag.
Rinse the probes only when they have returned to a normal temperature.
Avoid rinsing the probes when they are still hot, as it may cause damage. -
Once the probes are cleaned, always place them back in the booster station for charging and storage.
-
Do not immerse the booster station in water, as it is not waterproof.
-
Avoid placing the probes directly in a burning flame, as it can damage the probes.
-
Always ensure the probes are placed back into the booster station in the correct position. The black probe should be placed on the left side of the booster, and the white probe should be placed on the right side of the booster.
APP Description
Trouble Shooting
- Q: Why can’t it charge?
- A: Please check if the charging spring of the probe slot is loose, if it is loose, please contact us!
- Q: What should I do if I get a white screen?
- A: Please long press the power button to try to restart, if it still can’t be solved, please contact us!
- Q: How much remote range should I expect?
- A:1.Connect in an outdoor open area with a wireless range of up to 200 ft (60 m) from the booster to the phone and up to 32 ft (10 m) from the probe to the booster.
- 2. The actual Bluetooth range also relates to the cell phone you are using and the cell phone’s Bluetooth version.
- Q: What should I do if no temperature display after powering on?
- A: If the temperature is not displayed, it may be due to the probe not being plugged into the booster properly. You should reinsert the probe into the booster.
Black probes on the left, white probes on the right.
FCC STATEMENT
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
- This device may not cause harmful interference, and
- this device must accept any interference received, including interference that may cause undesired operation.
Any Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, according to part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used under the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment to an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
FCC Radiation Exposure statement
The device has been evaluatec to meel general RF exposure requirement. The
device can be used in porlable exposure condition without restriction.
NOTE
- If you encounter any problems, please contact us at sale@szbfour.com.
- We will provide a free warranty or replacement service.
For more New Arrivals & Exclusive Deals, please Follow Us
- @Bfour
- @Bfour
- @Bfourshop_us
- @Bfour_meatthermometer
- https://bfour.cc/
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>