Clarke 6909951 Richmond Ii Eco Design Cast Iron Stove User Guide
- September 26, 2024
- Clarke
Table of Contents
- 6909951 Richmond Ii Eco Design Cast Iron Stove
- Product Information
- Technical Specifications
- Product Usage Instructions
- Installation
- Compliance with Regulations
- Maintenance and Usage
- Q: What should I do if I suspect a fault with the stove?
- Q: Can I use fuels other than wood logs in the Richmond II
- Q: How often should I clean the stove?
6909951 Richmond Ii Eco Design Cast Iron Stove
Product Information
Technical Specifications
- Product Name: Richmond II Eco Design Cast Iron Stove
- Part Number: 6909951
- Guarantee: 12 months from the date of purchase
- Recommended Fuel: Wood logs
- Compliance: Clean Air Act 1993 & Smoke Control Areas
Product Usage Instructions
Installation
Warning: An accredited heating engineer must
carry out the installation of this stove to prevent risks of fire
or carbon monoxide poisoning. Failure to comply with installation
regulations may have legal consequences.
Ensure that the stove is fitted correctly by an approved person
to prevent any safety hazards.
Compliance with Regulations
Read all instructions carefully before installation. The
installation must comply with Building Regulation ‘J’, Local
Authority Bye-laws, European and National standards, and any other
relevant specifications or regulations.
Maintenance and Usage
Use only wood logs as the recommended fuel for the Richmond II
stove. Ensure that a permanent stop is fitted to prevent closure of
the secondary air control beyond 3mm open when in use in smoke
control areas.
FAQ
Q: What should I do if I suspect a fault with the stove?
A: If you suspect a fault with the stove,
please contact our Parts & Service team at 020 8988 7400 or via
email at Parts@clarkeinternational.com or
Service@clarkeinternational.com for assistance.
Q: Can I use fuels other than wood logs in the Richmond II
stove?
A: No, it is recommended to use only wood logs
as the fuel for the Richmond II stove to ensure compliance with
regulations and optimal performance.
Q: How often should I clean the stove?
A: Regular cleaning is essential for
maintaining the stove’s efficiency. Clean the stove according to
the manufacturer’s instructions or when a build-up of ash or soot
is visible.
RICHMOND II ECO DESIGN CAST IRON STOVE
PART NO: 6909951
USER GUIDE
ORIGINAL INSTRUCTIONS
08 July 24 GC Rev 3
INTRODUCTION
Thank you for purchasing this CLARKE Stove which is approved for use in
smokecontrolled zones. It is designed and produced according to the standard
EN13240+Amendment A2:2004. The stove is supplied with various removable
components including the lining panels, the log retainer, ash pan, and handle
which require checking for correct fitting. Before attempting to operate the
stove, it is essential that you read this manual thoroughly and carefully
follow all instructions given. In doing so you will ensure the safety of
yourself and that of others around you, and you can also look forward to the
product giving you long and satisfactory service.
INSTALLATION OF THIS PRODUCT
WARNING: AN ACCREDITED HEATING ENGINEER MUST CARRY OUT THE INSTALLATION OF
THIS STOVE. ALTERNATIVELY, SHOULD A NON-ACCREDITED ENGINEER UNDERTAKE THE
INSTALLATION, YOUR LOCAL BUILDING CONTROL OFFICER WILL BE REQUIRED TO APPROVE
THE COMPLETED INSTALLATION UNDER BUILDING REGULATION “J”. IT IS AN OFFENCE
UNDER UK LAW, NOT TO COMPLY WITH THIS MANDATORY REQUIREMENT.IF THE STOVE IS
NOT FITTED CORRECTLY BY AN APPROVED PERSON, IT COULD RESULT IN A HOUSE FIRE OR
CARBON MONOXIDE POISONING.
READ ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLATION
CAUTION: The instructions cover the basic principles to ensure satisfactory
installation of the stove, although detail may need slight modification to
suit particular site conditions. In all cases the installation must comply
with current Building Regulation `J’, Local Authority Bye-laws, European and
National standards and any other specifications or regulations as they affect
the installation of the stove.
CAUTION: The information contained in this manual includes extracts from the
Building Regulations 2000 “Approved Document J” (Combustion Appliances and
Fuel Storage Systems), updated 2013. This guidance information in no way
replaces your responsibility as an installer or end user to comply with the
appropriate standards.
2 of 32
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or
Service@clarkeinternational.com
TECHNICAL SPECIFICATIONS
GUARANTEE
This CLARKE product is guaranteed against faulty manufacture for a period of
12 months from the date of purchase. Please keep your receipt as proof of
purchase. This guarantee is invalid if the product is found to have been
abused or tampered with in any way, or not used for the purpose for which it
was intended. Faulty goods should be returned to their place of purchase, no
product can be returned to us without prior permission. This guarantee does
not effect your statutory rights.
3 of 32
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or
Service@clarkeinternational.com
CLEAN AIR ACT 1993 & SMOKE CONTROL AREAS
Under the Clean Air Act local authorities may declare the whole or part of the
district of the authority to be a smoke control area. It is an offence to emit
smoke from a chimney of a building, from a furnace or from any fixed boiler if
located in a designated smoke control area. It is also an offence to acquire
an “unauthorised fuel” for use within a smoke control area unless it is used
in an “exempt” appliance (“exempted” from the controls which generally apply
in the smoke control area).
In England appliances are exempted by publication on a list by the Secretary
of State in accordance with changes made to sections 20 and 21 of the Clean
Air Act 1993 by Section 15 of the De-regulation Act 2015. Similarly in
Scotland appliances are exempted by publication on a list by Scottish
Ministers under section 50 of the Regulatory Reform (Scotland) Act 2014. In
Northern Ireland appliances are exempted by publication on a list by the
Department of Agriculture, Environment and Rural Affairs under Section 16 of
the Environmental Better regulation Act (Northern Ireland) 2016.
In Wales appliances are exempted by regulations made by Welsh ministers.
Further information on the requirements of the Clean Air Act can be found
here:
https://www.gov.uk/smoke-control-area-rules
Your local authority is responsible for implementing the Clean Air Act 1993
including designation and supervision of smoke control areas and you can
contact them for details of Clean Air Act requirements.
This Richmond II stove has been recommended as suitable for use in smoke
control areas when burning wood logs. The Richmond II must be fitted with a
permanent stop to prevent closure of the secondary air control beyond 3mm
open.
Please note the following advice on minimising smoke emissions:
REFUELLING ON TO A LOW FIRE BED
If there is insufficient burning material in the fire-bed to light a new fuel
charge, excessive smoke emission can occur. Refuelling must be carried out
onto a sufficient quantity of glowing embers and ash that the new fuel charge
will ignite in a reasonable period. If there are too few embers in the fire
bed, add suitable kindling to prevent excessive smoke.
FUEL OVERLOADING
The maximum amount of fuel is not specified in this manual but in general,
overloading can cause excess smoke.
OPERATION WITH DOOR LEFT OPEN Operation with the door open can cause excess
smoke. DO NOT operate the stove with the door open except when re-fuelling.
4 of 32
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or
Service@clarkeinternational.com
DAMPERS LEFT OPEN Operation with the air controls or appliance dampers open
can cause excess smoke. The appliance must not be operated with air controls,
appliance dampers or door left open except as directed in the instructions.
SAFETY WARNINGS FOR YOUR GUIDANCE
CAUTION: FIRES CAN BE DANGEROUS – Always use a fireguard in the presence of
children, the elderly or the infirm. The fireguard should be manufactured in
accordance with B.S. 6539 – Fireguards for use with solid fuel appliances.
CAUTION: DO NOT OVERFIRE – it is possible to fire the stove beyond its design
capacity. This could damage the stove, so watch for signs of overfiring – if
any part of the stove starts to glow red, the stove is in an overfire
situation and the controls should be adjusted accordingly. Never leave the
stove unattended for long periods without first adjusting the controls to a
safe setting. Careful air supply control should be exercised at all times.
CAUTION: THIS STOVE MUST BE CONNECTED TO A SUITABLE FLUE OUTLET. Due to high
temperature this stove should be located well away from furniture and
curtains. Children and adults should be alerted to the hazards of hot
surfaces. Young children should be carefully supervised when they are in the
same room as the stove. Do not place clothing or other flammable material on
or near the stove. Keep the stove area clear of combustible materials,
flammable liquids or vapours. CAUTION: CARBON MONOXIDE POISONING CAN BE FATAL.
Carbon Monoxide detectors to BS EN 50291 are available for use in domestic
premises and details are available in the official HETAS guide that can be
viewed on their website at www.hetas.co.uk. Due consideration should be given
to the dangers of carbon monoxide poisoning following incomplete combustion of
solid fuels in an enclosed space. SEE PAGE 18 OF THIS BOOKLET.
5 of 32
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or
Service@clarkeinternational.com
GENERAL SAFETY RULES
WARNING: THIS STOVE WILL BE HOT WHEN IN OPERATION AND DUE CARE SHOULD BE
TAKEN. THICK GLOVES SHOULD BE USED TO OPERATE THE PRIMARY/SECONDARY CONTROLS
OR REACHING INSIDE THE STOVE TO POSITION FUEL OR REMOVE ASH.
1. ALWAYS read and understand the manual before installing and commissioning
the stove.
2. ALWAYS check for damage before using the stove. Check for breakage of
parts and any other condition that may affect the stoves performance. Any
damage should be properly repaired or the part replaced. If in doubt, DO NOT
use the stove. Consult your local dealer. Always ensure the stove is installed
in accordance with local regulations.
3. ALWAYS ensure that the stove is correctly installed and positioned as
described under POSITIONING AND INSTALLATION, and that the immediate area is
kept clear.
4. ALWAYS keep children and visitors at a safe distance from the stove. 5.
NEVER direct any kind of liquid on to the stove, particularly when it is hot.
6. NEVER use petrol or other flammable liquids for fire starting. 7. NEVER use
the stove to incinerate materials other than recommended fuels. 8. NEVER carry
out any modifications to this product. If experiencing difficulty of
any kind consult your local dealer. 9. The installation of the stove and
chimney MUST comply with all National,
European and local building regulations. It is the responsibility of the owner
and the installer to ensure that the installation complies. 10. All rooms
where a stove is situated must have a non-motorised air vent. Refer to details
contained in the Building Regulations. IMPORTANT: Building Regulation “J” is
the Government approved document covering the installation of solid fuel
stoves.
6 of 32
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or
Service@clarkeinternational.com
UNPACKING
WARNING: DUE TO THE WEIGHT OF THE STOVE IT IS ADVISED THAT TWO PEOPLE PERFORM
THE UNPACKING.
Unpack the stove and remove packing materials. Open the door and remove the
loose items from inside the stove. Before proceeding, please check contents
against the following list and advise your dealer immediately if any parts are
missing. Refer also to parts list & diagram on pages 28 & 29.
· 1 x Stove · 1 x Flue Collar · 4 x Legs · Fixings (packed) · 1 x Ash Pan · 1
x Ashpan Handle · Heat resistant mitt · Hex Key
TOOLS REQUIRED
· CLARKE Fire Cement (Part No 691000) · 13mm spanner · Hex key (supplied)
A full range of flue pipes and fire cement is available from your CLARKE
dealer. See page 26.
7 of 32
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or
Service@clarkeinternational.com
ASSEMBLY
1. Attach the flue adaptor using the screws supplied. Ensure the fireproof
gasket is correctly seated.
· The blanking plate will be installed in the rear of the stove when the
normal flue exit is required.
· If the rear mounting flue configuration is to be used, the blanking plate
will be fitted to the top of the stove and the flue connector to the rear
panel.
2. Check that the firebricks, top baffle and log retaining grate have not
been dislodged during transit and re-position if required.
3. Bolt the legs to the base of the stove using the bolts and large washers
supplied as in Fig 2.
4. Slide the ashpan into position. · An ashpan handle is supplied for
when the stove is in use. 5. Position the stove in the desired
location as shown in POSITIONING AND INSTALLATION. Take care not to damage the
floor surface. 6. Adjust the stove levelling bolts shown in Fig 3 until the
stove is level, evenly supported and does not rock. Take care not to damage
the floor surface. 7. If there are any gaps between the components, these
should be filled with CLARKE fire cement to prevent smoke emissions.
8 of 32
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or
Service@clarkeinternational.com
POSITIONING AND INSTALLATION
REGULATORY COMPLIANCE
In England and Wales, there are only two routes to legally install a domestic
solid fuel or wood burning appliance. In other parts of the UK there are
variations in legislation and processes.
You can either:
· Use a registered installer who can self certify that the work he does
complies with the relevant Building Regulations; or
· The consumer applies to their local authority building control department
for a building notice, and pays the appropriate fee.
It is generally worthwhile to use a HETAS registered installer who will supply
a Certificate of Compliance as a record of the job and that it complies with
Building Regulations. A copy of the certificate is forwarded to HETAS who
notify the local authority on your behalf.
Failure to notify the work through the registration scheme (in this case
HETAS) or directly to the local authority can lead to enforcement. It can also
cause problems for future house sales if there is no official record of a
compliant installation. All local regulations, including those referring to
National and European Standards need to be complied with when installing this
appliance.
For specific guidance when cast iron stoves are being installed in boats or in
homes with thatched roofs, please refer to the SOLIFTEC website at:
www.soliftec.com/installation.htm
SUPPORTING FLOORS
The stove must only be installed on floors with an adequate load bearing
capacity and if the existing construction is not suitable, additional measures
such as a load distributing plate must be provided.
The hearth should be able to accommodate the weight of the stove and its
chimney if the chimney is not independently supported. Stoves should stand
wholly above hearths made of non-combustible board/sheet material or tiles at
least 12mm thick, if the stove is not to stand in a recess and has been tested
to an applicable standard to verify that it cannot cause the temperature of
the upper surface of the hearth to exceed 100oC.
A constructional hearth should be used when the stove has beed tested to an
applicable standard and the upper surface of the hearth exceeds 100oC.
Constructional hearths should be made of solid, non-combustible material such
as concrete or masonry, at least 125mm thick, including the thickness of any
noncombustible floor and/or decorative surface.
9 of 32
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or
Service@clarkeinternational.com
Specific guidance for surfaces on which the stove may be allowed to stand is
given in Approved Document J and must be followed. Combustible material should
not be placed beneath constructional heaths unless there is an air space of at
least 50mm between the underside of the hearth and the combustible material,
or the combustible material is at least 250mm below the top of the hearth. The
maximum hearth temperature recorded in the Type Test Report for this stove is
126oC. NOTE: Always refer to building regulations 2000 Approved Document J.
When the stove is positioned near a wall constructed of flammable material,
the distances shown on Fig 4 must be adhered to. Alternatively, a heat shield
may be used, mounted according to the position of the fireplace. A firewall
must be at least 100mm thick and typically made of brick, or concrete/stone.
MATERIAL CLEARANCES
The stove must have a minimum clearance of 700mm to a combustible ceiling
above. FIG 4
It is recommended that the stove be installed at least 700 mm from combustible
materials which could be adversely affected by heat. The stove can be recessed
in a suitable sized fireplace but a permanent free air gap of at least 700mm
must be left around the sides and top and at least 725mm at the back of the
stove to obtain maximum heat output and for access to the rear of the stove.
MINIMUM DISTANCE TO COMBUSTIBLE MATERIALS Note: combustible material refers to
any material that will degrade when subjected to heat e.g. plaster.
10 of 32
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or
Service@clarkeinternational.com
Due to the heat of a hot stove, a suitable fire guard should always be used to
provide additional protection. Never allow young children to be left
unsupervised in a room containing a hot stove.
Note; If in doubt, refer to the Building Regulations 2000 Approved Document
“J”.
CHIMNEY CONSTRUCTION
The stove is supplied with both a top and rear flue pipe connector. It should
never be connected to a shared chimney/flue system.
Flue pipes with a smaller cross-sectional area than that of the stove outlet
should never be used and must not project into the chimney connector, such as
to cause a restriction to the gas flow.
Sizes of flues in chimneys are stipulated in Table 2 of the Building
Regulations 2000 Approved Document “J” as follows: 1. Stoves under 20kW rated
output which burn smokeless or low volatile fuel require
a minimum flue size of 125mm diameter (or rectangular flues having the same
cross-sectional area and a minimum dimension not less than 100mm for straight
flues or 125mm for flues with bends or offsets.
2. Stoves of up to 30kW rated output burning any fuel require 150mm diameter
(or rectangular flues having the same cross-sectional area and a minimum
dimension not less than 125mm.
Liners should be installed in accordance with their manufacturers
instructions. Appropriate components should be selected to form the flue
without cutting and to keep joints to a minimum. Bends and offsets should be
formed only with the matching factory-made components. Liners need to be
placed with the sockets or rebate ends uppermost to contain moisture and other
condensates in the flue. Joints should be sealed with fire cement, refractory
mortar or installed in accordance with their manufacturers instructions.
Ensure the joints are completely sealed as air leakage will lead to poor
performance. Avoid having more than two bends in the flue system. Any offset
between bends should be minimised and the flue should be equipped with
suitable access doors for inspection & cleaning. For further detail refer to
Building Regulations document “J”.
Special methods are required when passing through a wall or ceiling. Please
refer to your local building regulations and/or fire department. Refer to
Building Regulations Document “J”.
CAUTION: THIS STOVE MUST NOT BE INSTALLED INTO A CHIMNEY THAT SERVES ANY OTHER
HEATING APPLIANCE. THERE MUST NOT BE AN EXTRACTOR FAN FITTED IN THE SAME ROOM
AS THE STOVE, AS THIS CAN CAUSE THE STOVE TO EMIT FUMES INTO THE ROOM
11 of 32
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or
Service@clarkeinternational.com
FLUE HEIGHT
The chimney height and the position of the chimney should conform to the
Building Regulations document “J”. Flues should be high enough to clear the
products of combustion. The height necessary for this will depend on the type
of the stove, the height of the building, the type of flue and the number of
bends in it, and an assessment of local wind patterns. However, a minimum flue
height of 4.5m could be satisfactory if the guidance in paragraphs 2.10 to
2.12 of the Approved Document “J” is adopted. FIG 5
External flue pipes should be “twin wall”. These retain the heat, enabling it
to rise and disperse from the chimney. As an alternative approach, the
calculation procedure within BS EN 13384-1 (2005) can be used as the basis for
deciding whether a chimney design will provide sufficient draught. If in
doubt, consult the Building Regulations. The outlet from a flue should be
above the roof of the building in a position where the products of combustion
can discharge freely and will not present a fire hazard, whatever the wind
conditions.
12 of 32
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or
Service@clarkeinternational.com
FLUE PIPE COMPONENTS REQUIRED
FIG 6
A wide selection of flue pipes, connectors and other components as shown above
is available from your CLARKE stockist. See page 25.
13 of 32
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or
Service@clarkeinternational.com
BENDS IN FLUES Openings for inspection & cleaning should be formed using
purpose factory-made components compatible with the flue system, having an
access cover that has the same level of gas-tightness as the flue system and
an equal level of thermal insulation.
Offsets in flues are only acceptable if the following rules are respected:
· The chimney system shall have no more than 4 bends in total; – 2 bends in
the chimney and 2 bends in the flue pipe connection.
· The offset shall provide a change of direction no more than 45 degrees from
the vertical.
· Maximum length of horizontal flue must not exceed 150mm (6″).
The run of the chimney between bends shall not exceed 20% of the total chimney
length.
INSPECTION & CLEANING
Check that the chimney is in good condition, dry and free from cracks and
obstructions. The diameter of the chimney should not be less than 150mm and
not more than 230mm. If any of these requirements are not met, the chimney
should be lined by a suitable method.
The chimney must be swept before connection to the stove. Where the chimney is
believed to have previously served an open fire installation, it is possible
that the higher flue gas temperature from the stove may loosen deposits that
were previously firmly adhered, with the consequent risk of flue blockage. It
is therefore recommended that the chimney be swept a second time within a
month of regular use after installation.
Assuming that when the stove is first installed, the chimney is clean, and
sound, then the chimney flue should be inspected part way through the burning
season to establish the regularity of sweeping required. If you have any
doubts about the suitability of your chimney, consult your local
dealer/stockist.
If there is no existing chimney, then a prefabricated block chimney in
accordance with Building Regulations Approved Document J, or a twin-walled
insulated stainless steel flue to B.S.4543 can be used. These chimneys must be
fitted in accordance with the manufacturer’s instructions and Building
Regulations.
FLUE DRAUGHT
A flue draught of approx 12 Pa is required for satisfactory stove performance.
The flue draught should be checked under fire at high output. If it exceeds
the recommended maximum, a draught stabiliser must be fitted so that the rate
of burning can be controlled to prevent over-firing. If the reading is less
than the recommended minimum, then the performance of the stove will be
compromised.
14 of 32
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or
Service@clarkeinternational.com
AIR FOR COMBUSTION
Any room or space containing a stove should have a permanent air vent opening
of at least the sizes shown in the table below. For stoves designed to burn a
range of different solid fuels, the air supply should be designed to
accommodate burning the fuel that produces the highest heating output.
There must always be a permanent means of providing air for combustion into
the room in which the fire is installed. A permanent vent with a total free
area of at least 550mm2 for every kW rated above 5kW should be connected
directly to the outside air or an adjacent room which itself has a permanent
vent of the same size direct to the outside air.
The fitting of an extractor fan to either of these rooms is not permitted.
Stove Air Supplies Stove with flue draught stabiliser
Stove with no flue draft stabiliser
Permanently open vents as below:
If design air permeability>5.0m3/(h.m2) then 300mm2/kW for first 5kW of
appliance rated output 850mm2/kW for balance of appliance rated output
If design air permeability<5.0m3/(h.m2) then 850 mm2/kW for balance of
appliance rated output Permanently open vents as below:
If design air permeability>5.0m3/(h.m2) then 550 mm2/kW of appliance rated
output above 5kW
If design air permeability<5.0m3/(h.m2) then 550 mm2/kW for balance of
appliance rated output
CONNECTION TO THE CHIMNEY
This MUST be carried out by an accredited/competent person and/or approved by
your local Building Control Officer before using the stove.
Any existing flue must be in good condition with suitable access for
collection and removal of debris. Details of suitable linings for use with
solid fuel are given in the Official HETAS guide that can be viewed on their
website at www.hetas.co.uk
It is also important that suitable flue pipe complying with Building
Regulations is used to connect the stove to the chimney flue and that suitable
access is provided into the flue for regular inspection and sweeping of the
flueways.
15 of 32
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or
Service@clarkeinternational.com
Chimneys should be as straight as possible. Horizontal runs should be avoided
and the horizontal section should never exceed 150mm (6 inches) in length.
Flue connections must be well sealed. With a vertical rear flue the chimney
may be swept through the stove. If it is not possible to pass the sweeps brush
through the stove, a soot door will be necessary. This may be either in the
actual brickwork of the chimney or fitted in the register plate. Suitable
positions of soot doors are shown in Figures 7-8.
FIG 7 A non-combustible register plate minimum 1.5 mm thick should be fitted
to all installations between the flue and the building structure. It’s
suitability and fit should be checked by a qualified stove installation
engineer against the current Building Regulations App”J”. FIG 8
16 of 32
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or
Service@clarkeinternational.com
CLEANING THE FLUE
Access for cleaning the flue should be incorporated in the system other than
through the appliance (e.g. a soot door or access through a register plate).
Purpose-made soot doors and inspection lengths are available from the CLARKE
range. Ensure that the whole length of the flue can be reached from the soot
door.
FUME EMISSIONS
To avoid chimney problems, your fire should not be burnt slowly for longer
than 12 hours without a period of fast burning. Properly installed and
operated, this stove will not emit fumes although occasional fumes from de-
ashing and refuelling may occur. Persistent fume emission must not be
tolerated and if fume emission persists, the following immediate action should
be taken:1. Open doors and windows to ventilate room. 2. Let the fire out or
eject and safely dispose of fuel from the stove. 3. Check for flue chimney
blockage and clean if required. 4. DO NOT attempt to re-light the fire until
the cause has been identified and
corrected. If necessary, seek professional advice. IMPORTANT: NEVER fit an
extractor fan in the same room as this stove.
17 of 32
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or
Service@clarkeinternational.com
CARBON MONOXIDE ALARMS
Due consideration should be given to the dangers of carbon monoxide poisoning
following incomplete combustion of solid fuels in an enclosed space. Carbon
monoxide detectors to BS EN 50291 are available for use in domestic premises
and details are available in the official HETAS guide that can be viewed on
their website at www.hetas.co.uk. Where a new or replacement fixed solid fuel
appliance is installed in a dwelling, a carbon monoxide alarm should be
provided in the room where the appliance is located. Carbon monoxide alarms
should comply with BS EN 50291 and be powered by a battery, designed to
operate for the working life of the alarm. The alarm should incorporate a
warning device to alert users when the working life of the alarm is due to
pass. Mains-powered BS EN 50291 Type A carbon monoxide alarms with fixed
wiring (not plug-in types) may be used as alternative applications, provided
they are fitted with a sensor failure warning device. The carbon monoxide
alarm should be located in the same room as the stove: · on the ceiling at
least 300mm from any wall or, if located on a wall, as high up as
possible (above any doors and windows) but not within 150mm of the ceiling
and: · between 1m and 3m horizontally from the stove.
NOTE: Further guidance on the installation of carbon monoxide alarms is
available in BS EN 50292 and from manufacturers instructions. Provision of an
alarm should not be regarded as a substitute for correct installation and
regular servicing.
18 of 32
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or
Service@clarkeinternational.com
USING YOUR STOVE
STOVE CONTROLS
WARNING: THE TEMPERATURE REACHED BY THESE ITEMS DURING OPERATION MAY CAUSE AN
INJURY TO AN END-USER. AS THESE ARE INTENDED TO BE ADJUSTED DURING OPERATION,
IT IS RECOMMENDED THAT A PROTECTIVE MITT IS WORN WHEN HANDING THESE PARTS.
The amount of heat emitted by the stove is regulated using the air control
built into the door and to a lesser extent, by the air wash vent at the top of
the stove.
By adjusting the degree to which the main and airwash vents are opened, good
control of the combustion rate can be achieved. Both should be fully opened
while combustion is being established.
Opening the main air control vent can be used to revitalise the fire
effectively, producing significantly more vigorous combustion.
The `air-wash’ feature, when used, should function to effectively keep the
inside of the door glass clear of smoky deposits
SUITABLE FUELS
This stove can be used in smoke controlled zones to burn wood/logs and all
fuel should be dry and timber should be well seasoned so as to have a moisture
content below 20%.
· The use of damp wood will result in more soot and tar deposits being left in
the chimney, flue and stove, and will not release heat if thermal energy is
being used to drive out moisture from the fuel.
The smoke control website includes details of fuels authorised for use in
Smoke Control Areas but does not provide locations of Smoke Control Areas –
the user should check with the Local Authority to determine if they are in a
Smoke Control Area. The
19 of 32
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or
Service@clarkeinternational.com
current address of the smoke control website is https://www.gov.uk/smoke-
controlarea-rules.
Do not use the stove to incinerate other materials including household waste.
Avoid using `green’ unseasoned wood, treated wood such as telegraph poles, or
plywood / chipboard containing glues and resins which pollute the environment
and cause the fire to burn too quickly.
Such materials can produce excessive tar or creosote which can be damaging and
in extreme cases cause a fire inside the chimney.
The dryness of wood can be assessed by looking at the end of the log. Radial
cracks, deep enough to be considered as splits should be present in dry,
seasoned logs.
The maximum length of fuel suitable for this stove is approx 36 cm so as to
lay flat over the embers and logs of greater than 22 cm diameter should be
split.
Confirm with your fuel provider as to which type will suit best. Larger fuels
will allow a greater draught in the firebox which will speed up combustion.
For further information on type and availability of fuel, the Solid Fuel
Association (http:/www.solidfuel.co.uk) serves as an advice centre to domestic
consumers including all aspects of fuel types.
INITIAL SEASONING
CAUTION: THIS STOVE MUST BE SEASONED BEFORE USE. FAILURE TO CARRY OUT THIS
IMPORTANT PROCEDURE WILL RESULT IN PERMANENT DAMAGE TO THE STOVE AND WILL VOID
YOUR WARANTY.
Following installation and before regular use, the stove must be seasoned to
prevent cracking of the metal casting. This procedure should also be followed
if the stove has not been used for prolonged periods (during the summer months
for example) and is carried out as follows:
1. Light a small fire in the middle of the stove, well away from the sides.
2. Allow the stove to warm up slowly and evenly with the air controls almost
closed, avoiding intense flames.
3. Keep the fire burning for three hours or so, gradually increasing the size
of the fire using larger logs which will burn naturally but slowly, keeping
the stove on a low setting.
4. After a couple of days burning at this level, increase the brightness &
intensity of the fire gradually over the next 10 days.
Full strength fires should not be used until completion of approx 20 days of
mild use. Only from this time will the stove have been properly seasoned.
20 of 32
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or
Service@clarkeinternational.com
It should be remembered that this procedure should be carried out at the
beginning of each season of use in order to remove the moisture retained by
the metal during the period of non-use.
When used for the first time the fireplace may smell a little, due to gas
being given off. The gas is not toxic but the room should be thoroughly
ventilated. Let the fire burn with a high draught until no smells can be
detected.
Burning the stove at a very high temperature the first few times may damage
the paint. Burn fires at a moderate level the first few days. DO NOT place
anything on the stove top during the curing process as this may result in
damage to your paint finish.
Take care not to open the stove door too vigorously in case of causing smoke
spillage. If smoke spillage occurs after the fire door has been opened this
could be due to poor chimney draft. SEE TROUBLESHOOTING ON P27.
STARTING THE FIRE
1. Open the air control.
2. Lay firelighters or rolled up newspapers on the grate with a reasonable
quantity of dry kindling wood. Place 2 or 3 small logs on top.
3. Light the newspaper or firelighters using a long taper and close the door.
4. When the fire is burning strongly add further logs up to 10cm diameter.
5. When the stove is really hot, close the air control as required. Ensure
there are lasting flames until the wood becomes charcoal.
REFUELLING
1. Always open the door slowly to avoid a sudden rush of intake air and smoke
escaping into the room and add fuel.
2. Open the air controls and leave open for a few minutes to allow the gasses
in the wood to burn before closing the air controls.
· The rate of refuelling and heat available are dependant upon individual
requirements based upon the user’s experience. When re-loading, it is normally
necessary to burn the stove fast initially, to drive off any gasses and
moisture, before closing the air vents to control the burn rate.
· Ensure the door is kept closed to contain fumes except when lighting up,
refuelling or removing ash.
· It is not recommended to leave the stove alight at night or to continue
using the stove in mild weather which gives poor combustion leading to a
greater buildup of soot.
· If overnight burning is required, it can best be achieved by first driving
off any gasses or moisture as usual, following a full charge of fuel and then
closing the air vents fully. Experience will indicate the optimum setting.
However, by reducing the burn rate to such a level that the fire is still
burning the following day, the burning
21 of 32
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or
Service@clarkeinternational.com
process creates heavy, tarry chemicals which will become deposited on the
inside of the flue or chimney. This is an inefficient process which greatly
increases the risk of a chimney fire and makes it necessary to sweep the
chimney more often.
ASH REMOVAL
Keep the stove free from a heavy buildup of ash. The frequency of this is
dependant upon the type and quality of fuel being used. Ash should be removed
before it builds up to the underside of the grate, at which point, the grate
would be burning hot on both sides, shortening its life expectancy. When
disposing of ashes, ensure they have cooled and always place in a metal
container. Be sure to remove the ash when the fire is at its lowest point,
such as first thing in the morning. The CLARKE ASHVAC1200 Vacuum Cleaner (Part
No 6471130) is ideal for collecting ash and debris from stoves. See page 26.
22 of 32
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or
Service@clarkeinternational.com
MAINTENANCE
CLEANING
The inside of the stove may require regular cleaning, especially during
periods of peak use, the frequency of this being indicated by experience. It
is advisable to wear a dust mask, protective gloves and safety glasses when
cleaning. Use a stiff brush and industrial type vacuum cleaner to dislodge and
remove as much material as possible, starting at the top of the stove and
working down to the bottom. Particular attention should be given to the air
inlet controls which can become obstructed. An ASHVAC1200 Vacuum Cleaner is
ideal for this process.
GENERAL MAINTENANCE
Take this opportunity to check for any damaged parts inside the stove. In the
event of damage or broken components, replacements can be obtained from Clarke
Parts & Service. On no account should unauthorised spare parts be used. The
stove and flueway should be inspected and maintained when in a cold condition.
NO unauthorised modification of this product should be carried out. This stove
requires regular maintenance by a competent engineer. STOVE BODY The stove is
finished with a heat-resistant paint which can be cleaned with a soft brush.
Wait until the stove has cooled down before doing this. This finish can be
renovated with stove paint, although the paint may not be an exact match and
it may be necessary to repaint the complete stove. If the stove is purely
ornamental, painting will provide a durable, attractive finish. If the stove
is used for heating, a high temperature heat resistant paint (available from
your CLARKE dealer) must be used, in either aerosol or brush applied form.
Should rust become apparent, clean thoroughly with a wire brush and apply a
suitable antirust treatment. During prolonged periods out of use, the air
inlet should be left open and the door left slightly ajar in order to
circulate fresh air and discourage condensation from forming which could
encourage corrosion.
23 of 32
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or
Service@clarkeinternational.com
FIRE ROPE
Check the rope around the door and glass. If rope is in poor condition,
replace with rope approved for this purpose.
Inspect the fireproof door seal where fitted, to ensure there is an effective
seal around the door and re-fix it if loose using stove rope adhesive. If in
poor condition it should be replaced.
GLASS PANELS
Clean any glass panel when cool, avoiding abrasive substances which could
scratch the glass and make subsequent cleaning more difficult. Wet logs
against a heated glass, a badly aimed poker or heavy slamming of the door
could crack the glass panel. The glass will not fracture with heat. Never
replace any broken glass with glass NOT approved for use with stoves.
The window glass should remain clean during normal use but it can become
blackened if the stove is being operated with either damp fuels or at a slow
burn rate. The blackening may be dispersed by burning briefly at a much higher
temperature or it may be cleaned off using specialist glass cleaner.
In the event of the glass being broken, it can be removed by unscrewing the
retaining tabs, taking care not to damage the fireproof rope seal. The
replacement glass should be carefully placed against the seal and the
retaining tabs retensioned. Take care to tension these evenly or there is a
risk of breaking the new glass pane.
CHIMNEYS AND FLUE-WAYS
It is important that the chimney, flue-ways and any connecting flue pipe are
swept regularly. This means at least once a year for smokeless fuels and at
least twice a year for wood and other fuels.
Only wire-centred sweep’s brushes fitted with a guide wheel should be used. If
it is not possible to sweep all parts of the chimney through the stove, ensure
there is adequate access to cleaning doors.
If the stove is fitted in place of an open fire, then the chimney should be
swept one month after installation to clear any soot falls which may have
occurred, due to the difference in combustion performance between the stove
and the open fire.
The flue and chimney should be inspected for a build-up of deposits especially
following prolonged periods without use. The entire chimney/flue should be
swept frequently from top to bottom by a registered chimney sweep to remove
any build-up of soot etc, the frequency being dependant upon the usage and the
fuels being burnt.
24 of 32
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or
Service@clarkeinternational.com
If the chimney is swept after a few weeks of regular use, the condition found
will give an indication of the frequency of sweeping required. On an annual
basis, the chimney is best swept just before the main winter burning season.
HETAS recommends that chimney sweeping is best carried out by an approved
chimney sweep who will normally be a member of the National Association of
Chimney Sweeps or the Guild of Master Sweeps, details of which can be found on
the HETAS website, www.hetas.co.uk.
ACCESSORIES
Refer to the CLARKE website www.clarkeinternational.com for a full range of
Flue Pipes & Cowls (both Vitreous Enamel or Stainless Steel) for use with this
classic cast iron stove. See also the following accessories on page 26.
1
Straight flue pipe
2
Flue connector
3
90 deg tee with soot box
4
Twin wall standard cowl
5
Flue pipe with door
6
45 deg elbow with door
7
Ventilated fire stop
8
Storm collar
9
Adjustable roof plate
10 Wall band
25 of 32
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or
Service@clarkeinternational.com
Choose from the range of accessories suitable for use with this stove. Part No
6910000: Fire Cement (1Kg tub)
Part No 6912215 & 6912220: Heat-powered Stove Fans CSF4 & 5
Part No 3402152: Logbuster H4 (230v) Part No 3402048: Stand also available See
also Part No 3402032: Logbusters H5 and Part No 3402150: Logbuster V6
Part No 6910202: Glass Cleaner Part No 6910204: Stove Cleaner Spray
Part No 6910206: Matt Black Stove Paint (500ml)
Part No: 1801617: Paper Briquette Maker
Part No 6912112: Companion Set CS5
Part No 6471130: 1200W Ash Vacuum Cleaner
An extensive range of flue components is also available from your CLARKE
stockist.
ENVIRONMENTAL PROTECTION
Recycle unwanted materials instead of disposing of them as waste. All unwanted
accessories and packaging should be sorted and taken to a recycling centre for
disposal in a manner which is compatible with the environment.
26 of 32
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or
Service@clarkeinternational.com
TROUBLESHOOTING
PROBLEM Fire difficult to start. Fire goes out.
Fire burns too quickly.
Stove smokes when lighting up.
Low heat output. Smokes while burning
Smoke spillage when opening door.
CAUSE
SOLUTION
Wood green, too damp or Use recommended fuel. See p19 poor quality.
Logs are too large.
When lighting, use small, dry kindling. To maintain the fire use split logs.
Air starvation
Open air control. See p19
Insufficient draft.
Check that flue is not obstructed, sweep flue if necessary.
Too much draft.
Ensure the air control is closed.
Install a draught stabiliser. Consult your dealer.
DO NOT continuously burn small wood, sticks, carpentry offcuts, plywood etc
Flue duct is cold.
Burn paper and kindling wood to increase heat.
Room is at negative air pressure to the outside.
In houses equipped with mechanical ventilation, open a window until the fire is well established.
Incorrect fuels.
Use recommended fuels. See p19
Draft is insufficient
Consult a specialist. Check that flue is not obstructed. Sweep if necessary
Downdraught present.
Install an anti-downdraught cowl. Consult your dealer.
Room is at negative pressure to outside.
In houses equipped with mechanical ventilation, an outside air intake must be installed in the chimney.
Chimney not tall enough to Increase height of chimney. be clear of roof line.
Poor sealing of flue-pipe Re-connect flue or replace jointing
joints.
material
Flue is partially blocked with soot.
Arrange to have chimney swept.
House too tightly sealed. Ensure a fresh air supply is reaching the stove.
27 of 32
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or
Service@clarkeinternational.com
COMPONENT PARTS
28 of 32
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or
Service@clarkeinternational.com
COMPONENT PARTS
No Description
1
C/sunk screw
2
Flue adaptor
3
Fire rope gasket
4
Top panel
5
Baffle plate 1
6
Bolt
7
Baffle plate 2
8
Right firebrick
9
Right panel
10 Rear vermiculite firebrick
11 Rear air inlet
12 Rear panel
13 Fire rope gasket
14 C/sunk screw
15 Blanking plate
16 Left panel
17 Left firebrick
18 Grate
19 Log retainer bar
20 Vermiculite base panel 1
21 Vermiculite base panel 2
22 Base panel
No Description 23 Leg 24 Ashpan handle 25 Ashpan 26 Hinge pin 27 Top air inlet control bar 28 Top air inlet box 29 Top air inlet slider 1 30 Top air inlet slider 2 31 Slider bracket 32 Fire rope gasket 33 C/sunk screw 34 Glass retaining tab 35 Window glass 36 Door 37 Door handle shank 38 Door handle 39 Lower air inlet disc 40 Bolt 41 Nut 42 Leg fixing set 43 Front panel
29 of 32
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or
Service@clarkeinternational.com
DECLARATION OF PERFORMANCE – UK
30 of 32
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or
Service@clarkeinternational.com
DECLARATION OF PERFORMANCE – CE
31 of 32
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or
Service@clarkeinternational.com
References
- Home - Clarke International
- HETAS | Working together for a cleaner safer environment
- Smoke control areas: the rules - GOV.UK