Circutor M6-8 Epark Charge Point Instructions
- September 26, 2024
- Circutor
Table of Contents
Circutor M6-8 Epark Charge Point
Specifications
- Charge Point for electric vehicles, according to IEC 61851 standards
- Input: 32 A, 7.4 kW or 22 kW, 50 Hz / 60 Hz
- Connectivity: 10/100 BaseTx (TCP-IP), 2.4GHz (IEEE 802.11b/g/n), 4G LTE/3G/GPRS
- RFID: IEC 14443 A&B
- Dimensions: 700mm x 1000mm x 115mm
- Weight: 4 kg
Product Usage Instructions
Safety Precautions
Before installation or handling operations, ensure the device is
disconnected from power sources. Contact after-sales service for any
operational faults.
Installation Steps
- Ensure the device is powered off and disconnected.
- Mount the device on the wall using the provided screws.
- Connect the ground cable to the ground terminal.
- Use the provided cable glands for cable connections.
Connecting to Power
Connect the device to a power source according to the input specifications
provided (32 A, 7.4 kW or 22 kW).
Network Configuration
Set up the network connectivity as per your requirements using the provided
options (Ethernet, Wi-Fi, or Cellular).
Charging Electric Vehicles
Once installed and connected, the ePark Charge Point is ready to charge
electric vehicles. Follow the vehicle manufacturer’s instructions for
connecting and charging.
Frequently Asked Questions (FAQ)
-
Q: What should I do if I suspect an operational fault in the device?
A: Contact the after-sales service immediately for assistance and do not attempt any repairs yourself. -
Q: Can I use non-original accessories with the device?
A: It is recommended to use only original products or accessories made by the manufacturer to avoid any damage or malfunctions. -
Q: How do I ensure proper grounding during installation?
A: Connect the ground cable to the ground terminal as instructed in the manual and make sure to use copper cables for proper grounding.
RECHARGE BOX
This manual is a ePark installation guide. For further information, please download the full manual from the CIRCUTOR web site: www.circutor.com
| IMPORTANT!
---|---
The device must be disconnected from its power supply sources (power supply
and measurement) before under- taking any installation, repair or handling
operations on the device’s connections. Contact the after-sales service if you
suspect that there is an operational fault in the de- vice The device has been
designed for easy replacement in case of malfunction.
The manufacturer of the device is not responsible for any damage resulting
from failure by the user or in- staller to heed the warnings and/or
recommendations set out in this manual, nor for damage resulting from the use
of non-original products or accessories or those made by other manufacturers.
DESCRIPTION
ePark is a Charge Point which has been designed and tested to allow charging electric vehicles, vehicles, as specified at IEC 61851 standards.
INSTALLATION
Personal protective equipmen
What’s included
Technical features
AC Power supply|
---|---
Power supply (1)| 1P + N + PE, 3P + N + PE
Input|
Input voltage (1)| 230 V~ ± 10%, 400 V~ ± 10%
Output|
Output current| 32 A
Output power (1)| 7.4 kW, 22 kW
Frequency| 50 Hz / 60 Hz
Mínimum cable cross section| 10 mm2
User interface|
Light beacon| Indicador de color RGB / RGB Colour indicator
Connectivity|
Ethernet| 10/100 BaseTx (TCP-IP)
Wi-Fi| 2.4GHz (IEEE 802.11b/g/n)
Modem (Optional)| 4G LTE/3G/GPRS
Protocol| OCPP 1.6J / 2.0.1 (Preparado / Ready)
Authentication| RFID – IEC 14443 A&B
Environmental features|
Operating temperature| -5 ºC … +45 ºC (2)
Relative humidity (non-condensing)| 5 % … 95 %
Protection degree IP| IP54
Protection degree IK| IK10
Mechanical features|
Weight| 4 kg
Enclosure| PC + GF 10%
Enclosure closing system| Tornillos Allen antivandalismo / Antivandalism
Allen screws
Protections|
Upstream protections| MCB, RCD (No incluido / Not included)
Earth system compatible| TT, TN-S
Standards
IEC 61851-1; IEC 61851-21-2; IEC 62196-1; IEC 62196-2; Directives: 2014/35/EU,
LVD; 2014/30/EU, EMC; Compliant with The Electrical equipment (safety)
regulations 2016 guidance and The Electromagnetic compatibility regulations
2016 guidance; RFID complies with ISO/IEC 14443A/B; Modem 4G complies with
CE/RED and Radio Equipment Regulations 2017;
- Depending on model.
- -30ºC … +45ºC con/with LTK.
Dimensions
Minimum distances
WIRING
Single Phase: 230 V~
Three Phase: 400 V~
If single Phase: L1+N
Terminal block cross-section: ≤16 mm2
Do not forget to connect the ground cable to the ground terminal
Type of cable: Copper
Make sure all screws are securely tightened.
CLOSING SEQUENCE
Note: Device images are for illustrative purposes only and may differ from the actual device.
Service technique
CIRCUTOR SAT: 902 449 459 (SPAIN) / (+34) 937 452 919 (out of Spain)
Vial Sant Jordi, s/n
08232 – Viladecavalls (Barcelona)
Tel: (+34) 937 452 900 – Fax: (+34) 937 452 914
e-mail : sat@circutor.com
References
- Productos y Soluciones para la Eficiencia Energética Eléctrica
- Productos y Soluciones para la Eficiencia Energética Eléctrica
Read User Manual Online (PDF format)