Bullard XTCHARGERBASE XT Series Thermal Imager User Manual
- September 26, 2024
- Bullard
Table of Contents
- XTCHARGERBASE XT Series Thermal Imager
- Product Specifications:
- Desktop Charger (XTCHARGERBASE) – Installation and Usage:
- Truck Mount Charger (XTTRUCKMOUNT) – Installation and
- Truck Mount Charger (XTTRUCKMOUNT) – Troubleshooting:
- Frequently Asked Questions (FAQ):
- Q: What should I do if the charger indicates an AMBER LED?
XTCHARGERBASE XT Series Thermal Imager
“`html
Product Specifications:
-
Product Name: Bullard XT Series Charging Units
-
Battery Type: Sealed, internal long-life lithium ion battery
pack -
Charging Technology: Advanced wireless charging
-
Charging Options: Desktop Charger (XTCHARGERBASE), Truck Mount
Charger (XTTRUCKMOUNT)
Desktop Charger (XTCHARGERBASE) – Installation and Usage:
To install the Desktop Charger, follow these steps:
-
Select a convenient tabletop location to place the unit.
-
Connect the included power supply to a nearby AC power
outlet. -
Insert the power supply’s output power pin into the receptacle
on the rear of the charger.
When power is first applied to the charger, follow these
indications:
-
All three LEDs will briefly illuminate as a bulb check
cycle. -
The WHITE LED will remain illuminated, indicating the Charger
unit is ready for use.
Truck Mount Charger (XTTRUCKMOUNT) – Installation and
Usage:
To install the Truck Mount Charger:
- Connect it either hardwired to a vehicle or using the optional
AC power adapter.
When power is applied to the charger, follow these steps:
-
All three LEDs will briefly illuminate as a bulb check
cycle. -
The WHITE LED will remain illuminated, indicating the Charger
unit is ready for use.
To remove the imager from the Truck Mount Charger, depress the
release button and remove the imager.
Truck Mount Charger (XTTRUCKMOUNT) – Troubleshooting:
If the WHITE power LED is not illuminated when appropriately
wired to a vehicle:
-
Locate and open the fuse holder near the unit to inspect the
fuse. -
If the fuse has blown, replace it with a 5-Ampere glass fuse of
appropriate size.
WARNING: Only replace with an equivalent 5-Ampere fuse. Contact
a qualified technician if needed.
Frequently Asked Questions (FAQ):
Q: What should I do if the charger indicates an AMBER LED?
A: If the charger shows an AMBER LED, try re-seating the imager.
If the issue persists, contact Bullard Customer Service.
“`
Bullard XT Series Charging Units User Manual
Introduction
Your Bullard XT Series Thermal Imager is equipped with a sealed, internal
long-life lithium ion battery pack as well as advanced wireless charging
technology for use with the included Desktop Charger or optional Truck Mount
Charger. These easy to use charging stations are the fastest way to
charge your Bullard XT Series Thermal Imager’s battery.
Desktop Charger (XTCHARGERBASE)
Installation and Usage
To install the Desktop Charger, select a convenient tabletop location to place
the unit and connect the included power supply to a nearby AC power outlet.
Insert the power supply’s output power pin into the receptacle on the rear of
the charger. When power is first applied to the charger, all three LEDs will
briefly illuminate as a bulb check cycle, after which the WHITE LED will
remain illuminated. This indicates the Charger unit is powered on and ready
for use (Figure 1).
To charge the XT Thermal Imager’s battery in the Desktop Charger, place the
imager on the charger with the display side being cradled by the upright
portion of the charger and the four holes on the bottom side of the thermal
imager aligned with the four pins of the Interface Ring. When seated
correctly, the charger will emit a short beep and a BLUE LED will illuminate
on the right side of the charger. This indicates a connection with the imager.
When the connection has been verified and the battery is charging, the thermal
imager’s power button LED will pulse RED. When fully charged, the same LED
will change to steady GREEN.
If there is a problem with the charger or the connection with the imager, the
charger will illuminate an AMBER LED, located beneath the BLUE LED. In this
event, remove and attempt to re-seat the imager. If the issue
persists, contact Bullard Customer Service (Figure 2).
Truck Mount Charger (XTTRUCKMOUNT)
Installation
The XT Series Truck Mount Charger utilizes the same wireless charging
mechanism as the Desktop Charger but is is designed to be mounted securely in
accordance with NFPA 1901-14.1.10.2 and DIN EN 1846-2 5.1.2.2.2 when storage
of the Imager in a vehicle is required. Additionally, although the Truck Mount
Charger is designed for permanent vehicle installation, you may also choose to
use this unit in a free-standing manner. Free-standing use is not recommended
for vehicles. The same AC power supply functions with both the Truck Mount and
Desktop Chargers, but this power supply is optional with the Truck Mount
Charger (XTCHARGEPWR).
To install the Truck Mount Charger in a vehicle, select a convenient location
in either a vertical or horizontal orientation. Leave sufficient clearance
above the Charger for installation of the imager, below the Charger (if
additional accessories will be stored on the Charger), and in front of the
Charger for removal and reinstallation of the imager (Figure 3). A mounting
template is included with the Charger as a reference for clearance
requirements and mounting hole spacing. Mount the Charger using the included
(4) 5/16″ self-tapping hex screws. No drill holes are
required because of this type of screw.
Power on LED (White)
Interface Ring
Imager Charging LED (Red) (May flash Amber in extremely high or low temps)
Input Power Port
Imager Connected LED (Blue)
Fault LED (Amber)
Figure 1
Imager Connected LED (Blue)
Figure 2
The unit is provided with two wires for attachment to the power supply in the
vehicle. The wires are color-coded, with red signifying the positive (+)
conductor and white signifying the negative (-) conductor. Provide power to
the mounting location from a 5-Ampere fused power source with output of 12-24
VDC. For best results, the unit should be connected to an unswitched circuit
which continues to provide power when the vehicle is not in use so that a
mounted imager will remain charged at all times. Your vehicle maintenance
technician can advise as to the best wiring method for each individual
apparatus. Securely fasten the vehicle’s power supply wiring to the matching
positive and negative wires from the Charger by soldering or using twist-on or
crimp-style connectors. Consult an electrician if you experience difficulty or
require assistance.
California Proposition 65 WARNING Cancer and Reproductive Harm –
www.P65Warnings.ca.gov.
Propuesta de California 65 ADVERTENCIA Cáncer y Daño Reproductivo – www.P65Warnings.ca.gov.
Proposition de la Californie 65 AVERTISSMENT Cancer et Troubles de l’appareil
reproducteur – www.P65Warnings.ca.gov.
www.bullard.com
Truck Mount Charger (XTTRUCKMOUNT)
Usage
When power is first applied to the charger, (via either hardwired to a vehicle
or the optional AC power adapter) all three LEDs will briefly illuminate as a
bulb check cycle, after which the WHITE LED will remain illuminated. This
indicates the Charger unit is powered on and ready for use (Figure 3).
To charge the XT Thermal Imager’s battery, place the imager into the charger
with the display side up and the bottom of the imager facing the long side of
the charger. Ensure that the four pins of the Interface Ring align with the
four holes on the bottom side of the thermal imager. When seated correctly,
the release button will pop up and lock, and the charger will emit a short
beep and a BLUE LED will illuminate on the right side of the charger. This
indicates a connection with the imager. When the connection has been verified
and the battery is charging, the imager’s power button LED will pulse RED.
When fully charged, the same LED will change to steady GREEN..
To remove the imager from the charger, depress the release button and remove
the imager (Figure 4).
If there is a problem with the charger or the connection with the imager, the
charger will illuminate an AMBER LED, located beneath the BLUE LED. In this
event, remove and attempt to re-seat the imager. If the issue
persists, contact Bullard Customer Service.
Interface Ring Mounting Holes
Power on LED (White)
Imager Release Button
Mounting Holes
Imager Connected LED (Blue) Fault LED (Amber)
Input Power Port (for offvehicle use)
Figure 3
XTTRUCKMOUNT – Troubleshooting
If the Truck Mount Charger is appropriately wired to a vehicle but the WHITE
power LED is not illuminated, it is possible that the fuse has blown. Locate
and open the fuse holder which is on the red wire near the unit to inspect the
fuse. If the fuse has blown, it can be replaced with a 5x15mm or 5x20mm
5-Ampere glass fuse, commonly available at most automotive parts suppliers.
WARNING
Only replace with an equivalent 5-Ampere fuse. NEVER replace this or any fuse
with one of a higher current rating than designed. If the fuse blows
repeatedly, this indicates a fault with either the vehicle or the Charger. In
this event, contact a qualified vehicle technician or Bullard Customer
Service.
Imager Charging LED (Red) (May flash Amber in extremely high or low temps)
Imager Connected LED (Blue)
Interface Ring – Replacement
The Interface Ring on the Desktop and Truck Charger is user-replaceable in the
event of damage (XTCHARGERRING). This kit comes with a new ring and mounting
screws. A TORX® T8 bit is required to operate these screws. Remove the five
screws, then pull the old interface ring away from the charger and replace
with the new one. If the screw holes become worn, alternative holes are
provided and may also be used to secure the Interface Ring.
Warranty
Bullard warrants to the original purchaser that the Desktop and/or Truck Mount
charging station is free of defects in materials and workmanship under
intended use and service for a period of one year from date of manufacture.
Bullard’s obligation under this warranty is limited to repairing or replacing,
at Bullard’s option, articles that are returned within the warranty period and
that, after examination, are shown to Bullard’s satisfaction to be defective,
subject to the following limitations:
a) Article must be returned to Bullard with shipping charges prepaid. b)
Article must not be altered from its original configuration. c) Articles must
not have been misused, abused, or damaged in transport.
Imager Release Button
Figure 4
In no event shall Bullard be responsible for damages, loss of use, or other
indirect, incidental, consequential or special costs, expenses or damages
incurred by the purchaser, notwithstanding that Bullard has been advised of
the possibility of such damages. Any implied warranties, including warranties
of merchantability and fitness for a particular purpose, are limited in
duration to two years from the date of manufacture of this product. Some
states do not allow the exclusion or limitation of incidental or consequential
damages, or allow limitations on how long an implied warranty lasts, so the
above limitations or exclusions may not apply to you. This warranty gives you
specific legal rights and you may have other
rights which vary from state to state.
Bullard Center 2421 Fortune Drive Lexington, KY 40509 · USA 877.BULLARD (285.5273) Tel: +1.859.234.6616
Americas Operations 1898 Safety Way Cynthiana, KY 41031 · USA 877.BULLARD (285.5273) Tel: +1.859.234.6616
Bullard GmbH Dieselstrasse 8a 53424 Remagen · Germany Tel: +49.2642.999980
www.bullard.com
Bullard Asia Pacific 51 Changi Business Park Central 2 #03-04 The Signature
Singapore 486066 Tel: +65.6745.0556
©2024 Bullard. All rights reserved. 60510011097D (0124)
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>