Bullard SALUS HC System with Narrow LF Hood Instruction Manual
- June 3, 2024
- Bullard
Table of Contents
- Bullard SALUS HC System with Narrow LF Hood
- Limitations of Use and Warnings
- What’s in the box
- SALUS HC diagram
- Setup and Getting Started
- Operating Instructions
- Cleaning, Storage, and Disposal
- Powered Air Purifying Respirator Limited Warranty
- WARRANTY EXCLUSIONS AND DISCLAIMERS
- Supplemental Battery & Charger Instructions
- Specifications
- FCC Advice, valid in USA
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Bullard SALUS HC System with Narrow LF Hood
Limitations of Use and Warnings
Failure to follow these warnings AND INSTRUCTIONS could result in death or serious injury. Use strictly in accordance with instructions, labels and limitations pertaining to the EVA/EVAHL/SALUS HC-series respirators.
- This respirator does not supply oxygen. Use only in adequately ventilated areas containing at least 19.5% oxygen.
- Do not use when concentrations of contaminants are immediately dangerous to life or health (IDLH), i.e. – one for which the wearer cannot escape without the aid of a respirator without suffering injury either immediate or long term. See 29 CFR 1910.134 (b).
- Do not use this respirator for respiratory protection during abrasive blasting or clean-up.
- Do not use in circumstances where the airborne concentration level of a contaminant exceeds the maximum use concentration for this type of respirator as established by regulatory standards.
- Leave area immediately if:
- Breathing becomes difficult
- Dizziness or other distress occurs
- You taste or smell the contaminant
- Unit becomes damaged
- Battery alarm activates
- Low Flow alarm activates
- This apparatus must not be worn with the blower unit switched off. If the blower is switched off, a rapid build-up of carbon dioxide and depletion of oxygen may occur, which could result in death or serious injury.
- Never alter or modify this respirator. Use only Bullard-manufactured components and replacement parts for use with this respirator. Failure to use Bullard manufactured components and replacement parts, as listed on the NIOSH approval label, voids NIOSH approval of the entire respirator, and invalidates all Bullard warranties.
- This device is not immune to highly powered RFI/EMI emissions.
- Use strictly in accordance with instructions, labels and limitations pertaining to this respirator
In addition to the above stated warning and instructions, the SALUS HC respirator is intended to be used only in a pharmaceutical, hospital and/or medical setting.
Approvals and Certifications
The SALUS™ HC Powered Air-Purifying Respirator (PAPR) system, manufactured by
Bullard, meets the NIOSH PAPR100-P standard Bullard is certified to ISO
9001:2015
What is a PAPR
A PAPR or powered air-purifying respirator protects the user by filtering out
contaminants in the air. The system uses a blower to force the ambient air
through an air-purifying element to the hood and the breathing zone of the
wearer. This process creates an airflow inside the hood, providing a higher
assigned protection factor (APF) than the reusable elastomeric non-powered
air-purifying half facepiece (half mask) or N95 FFRs. A PAPR can be used for
protection during healthcare procedures in which HCP are exposed to greater
risks of aerosolized pathogens causing acute respiratory infections.
What’s in the box
PROTECTION
PAPR100-P – PAPR100-P Particulate Air Filter for Powered, Air Purifying
Respirators
CAUTIONS AND LIMITATIONS
- A. Not for use in atmospheres containing less than 19.5 percent oxygen.
- B. Not for use in atmospheres immediately dangerous to life or health.
- C. Do not exceed maximum use concentrations established by regulatory standards.
- F. Do not use Powered Air-Purifying Respirators if airflow is less than four cfm (115 lpm) for tight-fitting facepieces or six cfm (170 lpm) for hoods and / or helmets.
- I. Contains electrical parts that may cause an ignition in flammable or explosive atmospheres.
- J. Failure to properly use and maintain this product could result in injury or death.
- L. Follow the manufacturer’s User Instructions for changing cartridges, canister and / or filters.
- M. All approved respirators shall be selected, fitted, used, and maintained in accordance with MSHA, OSHA, and other applicable regulations.
- N. Never substitute, modify, add, or omit parts. Use only exact replacement parts in the configuration specified by the manufacturer.
- O. Refer to User Instructions, and/or maintenance manuals for information on use and maintenance of these respirators.
- P. NIOSH does not evaluate respirators for use as surgical masks.
SALUS HC diagram
Pre-Inspection
Closely inspect the entire PAPR (Powered Air-Purifying Respirator) system
paying attention to component connection points for wear and damage. If parts
are missing or damaged, replace them with only SALUS HC replacement parts
before proceeding.
- Inspect the filter for physical damage and check the label to ensure the filter has not exceeded its “use-by” date.
- Inspect the batty for any physical damage and check the fuel gauge to determine sufficient chare is available.
- Inspect the loose-fitting facepiece for any physical damage.
- Examine the breathing tube for tears, holes, or cracks. The breathing tube should fit securely into the blower unit connection and the loose-fitting facepiece.
- SALUS HC is pre-calibrated to ensure required airflow. With the system completely assembled, the blower unit automatically checks upon start up that the system is delivering adequate airflow.
Checking for adequate airflow
With the blower motor OFF, press and told the power button for ten (10)
seconds until there is an audible sound. This audible sound indicates that
there is adequate airflow to create a positive pressure inside the hood.
Setup and Getting Started
Initial unboxing
SALUS HC will ship in an outer pack box and package up to three (3) units per
box. The inner box is intended to keep your SALUS HC free from damage, clean
and organized for long-term storage. The unit will arrive partially assembled
only requiring the user to install the HEPA filter, and battery and attach the
breathing tube and hood. The Quick Start Guide that comes with SALUS should
remain with the user or in an area accessible by the user(s). The Quick Start
Guide provides two (2) useful QR codes and web addresses to enhance your
experience.
- SALUS HC online User Instructions provides an online and printable reference to detailed information about your PAPR. www.bullard.com/SALUS/usermanual
- SALUS HC onboarding gives you the opportunity to sign up for product training, virtually or in person, register your product, and get to know Bullard.
www.bullard.com/SALUS/onboarding
Complete assembly
- Charge and install the battery
Note: The battery initially ships with an approximately 30% charge but must be placed on the charging dock to activate. It is recommended to charge the battery fully before operating the respirator.
Battery charging
-
Connect the power cord to the power supply and the power supply to the battery charging dock
-
Plug the battery charger into a 110-120V electrical outlet
-
Place the battery into the battery charger
Battery fuel gauge -
Remove the battery to check battery level
Battery installation -
Open battery door on the SALUS HC
-
With battery pull tab facing out and the battery terminal on top, insert the battery into the battery housing
-
Close the battery door on SALUS HC
Install blower motor on shoulder carriage
- Press the carriage release hook into the opening on the shoulder carriage
- Insert blower motor cradle into shoulder carriage
- Insert slotted tabs of blower motor into the blower motor cradle
- Gentle press the neck of the blower motor down until you hear a CLICK
- Turn the shoulder carriage over to connect the power cord to the battery and blower motor unit
- Connect one (1) end of the power cord to the battery terminal and the other end to the blower motor terminal
- Begin pressing the power cord into the groove starting at the battery terminal and working towards the motor
Install the HEPA filter
- Insert the slotted tab of the filter into the blower motor
- Press filter down onto blower motor and lock filter tabs
- The filter will be secured when you hear both filter tabs CLICK
Connecting hood and breathing tube
- Insert the bayonet-style connection end of the breathing tube into the hood
- Turn clockwise a quarter turn until it locks into place
- Insert the other end of the breathing tube into the blower motor until you hear a CLICK
Complete Disassembly
- Disassemble SALUS HC in reverse order of assembly
- Breathing tube
- Engage the breathing tube release lever on the blower motor to uninstall the breathing tube
Blower motor
- Disconnect the power cord from the blower motor prior to removing the blower motor from the shoulder carriage
- Place thumb or finger on the blower motor cradle and gentle lift blower motor up
Battery housing
- The battery housing and battery door can be removed from the shoulder carriage for deep cleaning
- Disconnect the power cord from the battery housing prior to removing the battery housing from the shoulder carriage
Donning and Doffing
Prepare to don the PAPR system in a safe, hazard-free area. Prior to entering
a contaminated area and donning, complete the Pre-Inspection process.
Donning
Warning: Turn the blower motor ON before donning the hood
-
With SALUS HC completely assembled, place the PAPR onto your shoulders.
-
Turn the blower unit on. See Operating Setting for details.
-
Don the hood starting with your chin and pulling over your head. Make any final adjustments to the fit as required to ensure a comfortable and stable fit.
-
Connect the buckles on the body straps.
-
Adjust body straps to ensure a comfortable and stable fit.
-
Excess body strap material can be cut for a more customized fit.
Note: See Selecting Hood Size for more guidance in selecting an appropriate hood size -
Donning complete
Note: SALUS can be worn under isolation gowns with special consideration. The blower motor must not be covered by the isolation gown to allow the respirator to actively draw air through the filter and into the hood or breathing zone. Air flow may be reduced and trigger the low airflow alarm if the isolation gown is covering the air inlet or filter of the respirator.
Doffing
- Disconnect both body straps and allow to hang freely at your side
- With the breathing tube still connected, doff the hood back to front
- Slide the ball of the carriage release hook down and through the opening on the left shoulder of the carriage
- Move the shoulder carriage and entirety of the PAPR system to the right side of your torso to prevent the potential contamination of your breathing zone
- Turn blower OFF. See Operating Instructions for details
Note: Bullard does not make any specific claims around this doffing method relating to sterility. Please follow your organization’s standard operating procedures for specific donning and doffing instructions.
Operating Instructions
Operating Settings
When removed from the shoulder carriage, the battery housing includes a
diagram of the operational functions of SALUS.
-
ON/HIGH-SPEED
Press the button one time to turn the blower unit ON, confirmed by a short beep. The blower unit automatically turn ON at the high-speed setting after approximately 3 – 4 seconds. -
LOW-SPEED
Press the button again to toggle from High-Speed and Low-Speed, confirmed by a short beep. -
OFF
Press and hold the button for approximately 3 seconds to turn the blower unit OFF, confirmed by a short beep
Understanding Alarms
Low Battery Alarm
The Low Battery Alarm will sound an electronic beep indicating that there is
approximately 5% charge remaining.
Low Airflow Alarm
The Low Airflow Alarm will sound a continuous electronic beep indicating that
the flow to the hood has dropped below the designed specifications of 170
L/min (6 CFM)
Loss of Communication
The Loss of Communication will sound a continuous electronic beep of varying
frequencies indicating that the blower motor and battery are no longer
communicating.
Changing the HEPA filter
If the SALUS respirator is being used to reduce exposure to airborne
biological aerosols such as droplets containing viruses or bacteria, the HEPA
filter will likely not load (clog) from these particles to the point that they
will affect airflow. Loading of the HEPA filters is typically not an issue
when used for biological aerosols. In healthcare facilities, PAPR filter
change schedules for airborne biological aerosols are primarily determined by
the facility’s infection control policy, which should be developed based on
applicable national, state, and local guidelines. Most healthcare systems
develop their filter use and reuse policy based on the biological agent of
concern, the likelihood of the filter becoming contaminated, and the potential
for patient-to-patient and patient-to-worker cross-contamination. While the
outside filter body can be wiped down for cleaning, do not attempt to clean
the filter media inside the filter body. When changing the HEPA filter, follow
the hygiene and infection control practices established by your employer based
on the specific contaminants to which the respirator assembly has been exposed
and the cleaning agent used.
Selecting Hood Size
The LF-Series hood is available in two (2) widths and three (3) sizes in each
width to accommodate various face and head sizes for maximum comfort and
protection. The comfort fit, designated by 20LF, has a wider profile while the
contour fit, designated by 20LF2, has a narrower profile. If using the LF-
Series hood, select the size that fits most comfortably and where the entire
elasticized edge of the faceseal encounters your face. For additional
guidance, refer to the LF-Series Sizing Chart to further match your face shape
and head size. If your proper fit falls between two (2) sizes, default to the
smaller size to ensure a snug fit.
The LF-Series hood is available with a built-in PTFE-based HEPA panel along the jaw of the hood, which replaces the perforated panel under the user’s chin in the 20LF/20LF2 models. This model is designated with an HE suffix. Users should select their size using the same methodology as the 20LF model. The 20LF model with the HE suffix can be used in any application where the SALUS HC respirator, certified under the PAPR100-P standard, is appropriate. Additionally, it is intended to block large-particle droplets, splashes, sprays, or splatter from entering thehood.
Battery Maintenance and Operation
The blower motor speed, number of charge/discharge cycles, and battery age has
a direct relationship to battery life between charge cycles. A higher speed
will result in more airflow but reduce the battery run time. Batteries should
be stored in a cool, dry location and with a temperature between -20°C to 60°C
(max). Optimal temperature is -20°C to 25°C. Batteries have a life expectancy
of greater than 300 cycles with a minimum of 75% of initial capacity or 1 year
per the product warranty. See section called Supplemental Battery & Charger
Instructions for additional battery information.
Cleaning, Storage, and Disposal
Cleaning – Hood, filter
- Clean, dry and inspect prior to each use and before storage.
- Use warm water, mild dishwashing liquid and a soft brush to remove any dirt from exterior surfaces.
- Do not immerse equipment in water.
- Mechanical laundering of loose-fitting hoods is not recommended.
- Do not soak components in cleaning solutions or solvents.
- Thoroughly rinse the loose-fitting hood with clean, fresh water and allow to airdry.
- Bullard has tested several common decontamination and cleaning agents to determine if the integrity of the loose-fitting hood has been compromised after decontaminating. Based on this testing, it was determined that the hoods did not suffer any significant degradation when cleaned with these agents after eight times
- Coverage Plus NPD (Steris) 1:256 concentration with distilled water
- Process NPD (Steris) 1:256 concentration with distilled water
- Spor Klenz (Steris) undiluted
- Bleach (Clorox) 1% concentration
- Decon Alcohol (Veltek) 70%
- Decon Spore (Veltek) 6.4:128 concentration
- Quant 256 (Buckeye) 1:256 concentration with distilled water
- Superguard (Buckeye) 1:256 concentration with distilled water
- Sanicloth HB (Nice-Pak) undiluted
- SaniWipes (Prochem) undiluted
- Cavacide (Metrex) undiluted
- Cidex OPA (Johnson & Johnson) undiluted
Cleaning – Blower motor, breathing tube, shoulder carriage
-
Clean, dry and inspect prior to each use and before storage.
-
Use warm water, mild dishwashing liquid and a soft brush to remove any dirt from exterior surfaces.
-
As per CDC guidelines for disinfection, diluted household bleach solutions, alcohol solutions with at least 70% alcohol, and most common EPA-registered household disinfectants should be effective to disinfect exterior surfaces of the blower motor, breathing tube, exterior surface of the HEPA filter and shoulder carriage. Possible disinfection methods include:
-
ECOLAB® KLERCIDE™ 70/30 IPA (EPA Reg. No. 1677-249)
-
PeridoxRTU™ (EPA Reg. No 8383-13)
-
Sani-Cloth® Bleach Germicidal Disposable Wipes (9480-8)
-
Clorox Healthcare® Bleach Germicidal Disinfectant Wipes (EPA Reg. No.
67619-12) -
Sodium hypochlorite solution (free chlorine concentration of 5,000 ppm)
-
Process NPD (1.256) from Steris
-
Spor Klenz (undiluted) from Steris
-
Clorox liquid bleach at 10% concentration
-
Sani-Cloth HB wipes
-
100% Methanol
-
70% IPA
-
D-wipe
-
D-lead
-
3% hydrogen peroxide
-
1:10 ratio of bleach to water (0.5% sodium hypochlorite)
-
Clorox Healthcare Bleach Wipes (EPA ID 67619-12) – 0.55% Sodium Hypochlorite
-
Clorox Healthcare Bleach Trigger Spray (EPA ID 56392-7) – 0.65% Sodium Hypochlorite
-
Sani-Cloth® Bleach Germicidal Disposable Wipe (product of PDI Inc.) – Orange Top (EPA ID 9480-8)
-
Peridox RTU (EPA ID 8383-13)
-
Warning: Always read and follow the user instructions and/or EPA label for your selected disinfectant. Bullard strongly recommends that a water rinse/wipe down occurafter disinfection to thoroughly remove disinfection solution and reduce the possibility of user irritation and premature degradation of equipment.
- Components of PAPR respiratory systems may become damaged over time with prolonged or extended use of disinfecting products. Users must inspect the components of their PAPR respiratory systems following each disinfecting cycle and prior to use. If you discover any signs of damage, remove the component from service and either discard and replace or repair as appropriate.
- It is the responsibility of the employer to ensure appropriate cleaning chemicals are used which do not damage the PAPR system and components or cause harm to the wearer.
Storage
- The SALUS packaging is designed to store the respirator system where all system components have a place and everything in its place. All contents of the system are identified on the outside of the packaging for intuitive identification. Packaging is constructed to utilize the stacking of multiple respirator systems for long term storage.
- Store in a clean, contaminant free environment, protected from prolonged exposure to heat, sunlight, radiation, and chemicals.
- For prolonged storage, the motor/blower should be run at least once per year for 5 minutes to ensure continued proper lubrication of the motor.
- Respirators used for emergency purposes must be inspected monthly per OSHA 29CFR1910.134. This should include running the motor/blower.
Disposal
- Damaged or worn-out batteries should be disposed of in accordance with local, state and federal regulations at an approved hazardous waste recycling or disposal facility.
- Used filters and loose-fitting hoods should be disposed of based on the contaminates collected on it and according to local environmental regulations
Powered Air Purifying Respirator Limited Warranty
Models EVA, EVAHL, AND SALUS HC
Congratulations on your purchase! Bullard is to provide you with one of the
best Limited Warranties in the industry to cover your Powered Air-Purifying
Respirator (PAPR). Please read this document carefully as it contains
information to help you protect and service your investment. This document
contains important information about the limited warranty, the purchaser’s
obligations, warranty coverage and exclusions and other terms and conditions
that may affect Bullard’s obligations under this warranty.
Warranted Party
Bullard provides the following warranty to the Purchaser upon the terms and
conditions set forth herein. For purposes of this warranty, Purchaser shall
mean the original purchaser of the product. This warranty is not
transferrable.
WARRANTY PERIOD AND COVERAGE
PAPR sold after May 1, 2021, subject to the terms and conditions set forth
herein, shall have the following warranty periods:
WARRANTY COVERAGE
Defects in materials or workmanship. Bullard has the discretion to either
repair or replace the covered items. Covered items:
- PAPR blower motor & assembly
- Loose-fitting hood
- Breathing tube
- Filter / cartridge
SALUS HC blower motor – optional free Standard Warranty Extension, upon
product
registration, within ninety (90) days of purchase. Please review the SALUS HC
WARRANTY EXTENSION section below for details.
SALUS HC BLOWER MOTOR WARRANTY EXTENSION
The SALUS HC blower motor is eligible for a one (1) year Standard Limited
Warranty Extension, if the Purchaser registers the product online, WARRANTY
PERIOD ABOVE. NEITHER BULLARD NOR ITS DISTRIBUTORS SHALL BE LIABLE FOR ANY
INCIDENTAL, CONSEQUENTIAL, INDIRECT, SPECIAL, OR PUNITIVE DAMAGES OF ANY
NATURE, INCLUDING WITHOUT LIMITATION, LOST PROFITS, BUSINESS INTERRUPTION, OR
ANY OTHER DAMAGE WHETHER BASED IN CONTRACT, TORT, OR OTHERWISE. Some states do
not allow the exclusion or limitation of incidental or consequential damages
or limitations on how long an implied warranty lasts, so the above exclusion
or limitation may not apply to you. This warranty gives you specific legal
rights and youmay also have other rights that vary from state to state. THIS
LIMITED WARRANTY EXPRESSLY EXCLUDES ROUTINE PRODUCT MAINTENANCE AND SOFTWARE
UPDATES. ANY MISUSE, ALTERATION, MODIFICATION, REPAIR, ATTEMPTED REPAIR,
IMPROPER MAINTENANCE, NEGLECT, ABUSE OR FAILURE TO FOLLOW THE PRODUCT
INSTRUCTIONS, DAMAGE OR ANY OTHER IMPROPER CARE OR HANDLING OF THE PRODUCT
VOIDS THIS LIMITED WARRANTY. The foregoing is the only warranty made by
Bullard. No representative, dealer or any other person is authorized to make
any warranty, representation, condition or promiseon behalf of Bullard with
respect to this product. No terms or conditions other than those stated herein
or provided by law, and no agreement or understanding, oral or written, in any
way purporting to modify this warranty shall be binding upon Bullard, unless
made in writing and signed by an authorized employee of Bullard.
RETURN AUTHORIZATION
Please read the information below carefully and follow the process outlined
prior to returning any item(s) to Bullard. within ninety (90) days of
purchase. Purchasers may complete the SALUS HC product registration at
www.bullard.com/salushc/getstarted.
LIMITED WARRANTY CONDITIONS
Bullard’s obligation under this limited warranty is only to repair or replace,
at Bullard’s option. Items may be covered under this limited warranty period
if returned within the warranty period and determined by Bullard to be
defective, subject to the following limitations:
- this warranty does not apply to any parts that have been misused, altered or had repair attempted, or have been subject to abuse, accidental or otherwise.
- this warranty does not apply to expendable consumables, accessories or fabric components, such as, but not limited to, filters/cartridges, loose-fitting hoods/visors that have already been used.
- Bullard and all subsidiaries reserve the right to use replacement parts that are refurbished. Replaced or repaired parts, whether they have been refurbished or are original equipment, will operate properly and be free from defects in materials and workmanship for a period of ninety (90) days from the date of shipment to the customer, or for the remainder of the original warranty period, whichever is longer.
- All products must be returned to Bullard with shipping charges prepaid.
WARRANTY EXCLUSIONS AND DISCLAIMERS
THIS WARRANTY IS IN LIEU OF ANY OTHER WARRANTY, EXPRESS OR IMPLIED, INCLUDING WITHOUT LIMITATION, ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. TO THE EXTENT ANY IMPLIED WARRANTY IS REQUIRED BY LAW, IT IS LIMITED IN DURATION TO THE EXPRESS If you would like to make a warranty claim, please follow these steps:
- Submit an online RMA request to customerservice@bullard.com. Upon receipt, the Customer Service Representative will initiate a case.
- Your claim will be processed if found valid. You will be provided written permission, an RMA number and instructions for where to return the product.
- Shipping costs for warranted products are to be sent to Bullard pre-paid. Bullard cannot accept returned goods on a freight collect basis. Bullard is responsible for shipping costs for repaired or replaced products.
- Prior to returning the product, you must submit a PAPR Service-Certificate of Decontamination form found at www.bullard.com and submit to customerservice@bullard.com. Before returning a product, decontaminate and clean it to remove any hazardous materials which may have settled on the product during use. Laws and/or regulations prohibit the shipment of hazardous or contaminated materials. Products suspected to be contaminated will be professionally discarded at the customer’s expense.
- Returned products will be inspected upon return to the Bullard facility. A Customer Service Representative will call or email you with a quote for required repair work which is not covered by warranty. If the cost of repairs exceeds stated quote by more than 20%, your Customer Service Representative will call you again for authorization to complete repairs. After repairs are completed and the goods have been returned to you, Bullard will invoice you for actual work performed.
Supplemental Battery & Charger Instructions
Warning: This manual contains instructions for use and important safety information. Read the instructions carefully before using the product.
Safety
- Do not open or dismantle batteries.
- Do not expose batteries to heat or fire. Avoid storage in direct sunlight.
- Do not short-circuit a battery.
- Do not store batteries haphazardly in a box or drawer where they may shortcircuit each other or be short-circuited by other metal objects.
- Do not remove a battery from its original packaging until required for use.
- Do not subject batteries to mechanical shock.
- In the event of a battery leaking, do not allow the liquid to come in contact with the skin or eyes. If contact has been made, wash the affected area with copious amounts of water and seek medical advice.
- Do not use any charger other than that specifically provided for use with the equipment. See also chapter “Charging”.
- Observe the plus (+) and minus (–) marks on battery and equipment and ensure correct use.
- Do not mix batteries of different manufacture, capacity, size or type within a device.
- Keep batteries out of the reach of children.
- Keep batteries clean and dry.
- Secondary batteries need to be charged before use.
- Use only the battery in the application for which it was intended.
- When possible, remove the battery from the equipment when not in use.
- Do not store batteries longer than 1 month in discharged state.
- Do not storage batteries longer than 1 year without recharge.
- The battery must be recycled or disposed of properly
Operating Temperature
- For charge: 0°C to +45°C
- For discharge: -20°C to +60°C
Storage Temperature:
- < 1 year: -20°C to +20°C
- < 3 month: -20°C to +45°C
- < 1 month: -20°C to +60°C
Recommendation
Store the battery at below 20°C, low humidity, no dust and no corrosive gas
atmosphere. Store the battery with a state of charge between 40-60%. Charging:
Charge only with a SMBUS compliant charger, e.g. RRC-SMB-MBC. Refer also to
the manufacturer’s instructions or equipment manual for proper charging
instructions.
Specifications
- Type RRC2057
- Voltage 7.50V
- Capacity 6.40Ah
- Max. charge current 4.34A
- Max. charge voltage 8.70V
- Max. discharge current 8.50A
- Dimensions (L x W x H) 85.35mm x 77.65mm x 23.0mm (max.)
- Weight 240g
Recycling
Recycle batteries according to national and local regulations. Contact your
local representative for assistance. The batteries must be disposed only in a
discharged state at the collection center. In case of not fully discharged
batteries, provide for a risk against short circuits. Short circuits can be
prevented by isolating the terminals with tape.
Declaration of conformity
CE: The battery complies with the current regulations of the EU guidelines.
FCC: This device complies with part 15 of the FCC Rules. Operation is subject
to the following two conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
Introduction
The smart battery charger is used to charge SMBUS batteries (Smart Batteries)
with form factors RRC2040, 2040-2, 2054, 2057 or smart batteries with a
similar footprint e.g. 204x range, 205x range, etc..
Caution
Only batteries that comply with the Data Specification 1.0 or 1.1 can be
charged with this battery charger. Other rechargeable batteries or
conventional batteries may not be used.
Tip
Use smart batteries for as long as possible in your device before recharging.
The more completely they are discharged, the more exact the charger can
calculate capacity andcharge requirements.
Making Connections
- Connect the cable from the mains adapter to the battery charger.
- Connect the power cable to the mains adapter and plug it into the mains socket.
- The LED is going out after the selftest of the battery charger. The battery charger is ready for use.
- If the red control lamp remains on and no battery is in the charger, the battery charger is defective.
Charging Batteries
- Connect up the battery charger as described above.
- Place a discharged Smart Battery into the battery charger.
- The battery charger makes a battery recognition and intialisation.
- The battery will be charged. Leave the battery until the green control lamp lights.
- Then the battery is fully charged. Remove the battery for use.
FCC Advice, valid in USA
Warning: This battery charger may not be located in the vicinity of a patient. In accordance with EN60601-1-1, the horizontal distance must be at least 1.5 meters. Do not insert a fully charged battery into the charger repeatedly. Due to the high initial charge, the battery could be overcharged which could lead to damage to the battery andto the battery charger Use the battery charger only in dry indoor environments! Wet and moisture covered products should not be used! This product has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help. Changes or modifications of the device are not allowed.
Declaration of Conformity:
The battery charger complies to the current regulations of the EU guidelines
.
valid only for power supply
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>