SUNNY EX Emergency Exit Sign Light User Manual

September 25, 2024
Sunny

EX Emergency Exit Sign Light

“`html

Specifications:

  • Product Name: Emergency Exit Sign Light Series 6

  • Models: EX Series – Type C,W; EX Series – Type F; SL Series –
    Type C,W; SL Series – Type R

  • Indicators: AC, Charge/Full, On/Test, Fail

Product Usage Instructions:

Installation and Operation:

  1. Install the emergency exit sign light fixture in the desired
    location for displaying the emergency exit symbol.

  2. Ensure proper and secure installation to prevent accidents or
    damage.

  3. During operation, tests can be performed by pressing the
    Off/Test button on the fixture. The light will illuminate
    continuously.

  4. To turn off the light without plugging in the fixture, press
    the Off/Test button.

Important Notes on Using the Unit:

  1. Install indoors, away from direct sunlight and humidity. Avoid
    environments with temperatures above 50 degrees Celsius.

  2. Store in temperatures below 25 degrees Celsius and charge the
    battery every 3 months to maintain operational life.

  3. Always read the manual carefully before operating the unit for
    safe and effective use.

Indicators:

Display Meaning
AC A continuous orange light – Unit receiving normal AC power

supply.
The light turns off – No AC power supply.
Charge/Full| A continuous red light – Battery charging.
The light turns off – Battery fully charged.
On/Test| A continuous green light – Unit performing battery test.
Slow blinking green light every 2 seconds – Auto Test off.
Fast blinking green light every 1 second – Auto Test on.
Fail| Red light blinks three times every 15 seconds – Battery
Fail.
Red light blinks four times every 15 seconds – Charging Fail.

Remote Testing:

  • Button for turning on ECO Mode, an energy-saving system.
  • Button for testing device function for 30 minutes.
  • Button for testing device function for 60 minutes.

Frequently Asked Questions (FAQ):

Q: How often should I charge the battery of the emergency exit

sign light?

A: The battery should be charged every 3 months to maintain its
operational life.

Q: What does it mean when the Fail indicator lights up?

A: The Fail indicator lights up when there is a problem with the
battery, either when it supplies lighting for less than 120 minutes
or when the charging system fails to charge properly.

“`

USER MANUAL
Emergency Exit Sign Light Series 6

EX Series – Type C,W

EX Series – Type F

SL Series – Type C,W

SL Series – Type R

Switch Off/Test
LED AC LED Charge/Full IR LED On/Test LED Fail

Press to turn off the lamp and the system of the unit (while the power is off or the unit is not plugged in) / Press to test the device’s availability (during normal circumstance and the unit is plugged in) Indicates that the unit is receiving a power supply Indicates that the unit’s battery is charging Infrared signal receiver Indicates that the unit is receiving a power / Indicates if the unit is performing a self-test Indicates there is a problem with the battery

Status Indicators and Testing Buttons

Installation and Operation

1. Install the emergency exit sign light fixture by securing it in the desired location for displaying the emergency exit symbol.
2. Install properly and securely to prevent accidents that could cause damage to the unit or other people and property.
3. Plug the device’s power plug into the power outlet of the building or household with an electrical voltage of 220-240VAC/50Hz. The emergency exit sign lights will illuminate. Please observe the operation of the device as follows: 3.1 The LED “AC” will turn on indicating that the unit is receiving power. 3.2 LED “On/Test” lit indicates the status of the unit ready to use. 3.3 The LED “Charge/Full” will be on when the battery is charging. 3.4 The LED “Charge/Full” will be off when the battery is fully charged.
4. When the unit is operational, tests can be performed. 4.1 Press the Off/Test button on the emergency exit sign light fixture. The light from the sign will continuously illuminate.
5. When you want to turn off the light without plugging in the emergency exit sign light fixture, press the Off/Test button.

Caution: Please always read the manual prior to installation and operation.

1

Important Note on Using the Unit
1. The unit should be installed indoors, out of direct sunlight and humidity. It should not be installed in environment with temperatures higher than 50 degrees Celsius.
2. The unit should be stored in temperatures under 25 Degree Celsius and the battery should be charged every 3 months to maintain its operational life.
3. Please always read the manual carefully prior to operating the unit for the saftest and most effective use of the product.

Indicators

Indication Lights

Display

Meaning

AC

– A continuous orange light – The unit is receiving a normal AC power supply.

– The orange light turns off – The unit is not receiving an AC power supply.

Charge/Full – A continuous red light
– The red light turns off

– The battery is charging. – The battery is fully charged.

On/ Test

– A continuous green light
– Slow blinking green light every 2 seconds
– Fast blinking green light every 1 seconds

– When pressing “OFF” to turn off the automatic battery test system (Auto Test) from the remote.
– When pressing “ON” to turn on the automatic battery test system (Auto Test) from the remote.
– The unit is performing a battery test (Auto Test).

Fail

– A red light blinks three

– “Battery Fail” When the emergency light unit supply

times every 15 seconds

backs up the lighting for less than 120 minutes, or less

than the time tested with a remote control.

– A red light blinks four

– “Charging fail” When the battery charging system does

times every 15 seconds

not charge, the charger does not cut off, the charging

circuit cuts off, but the battery charge decreases too

quickly.

2

Remote Testing

Button for turning on ECO Mode an energy-saving system.
Button for testing the device’s function for 30 minutes.
Button for testing the device’s function for 60 minutes.
Button for turning on auto battery test system.
Button for turning off auto battery test system.
While Power is On · Use to turn lamps on and off (In case the light is turned off,
the ECO Mode function will be canceled) · Use to stop the device’s automated testing (Auto Test) · Use to cancel the device testing for 30 minutes or 60 minutes · Use to cancel alerts when abnormality alerts are issued
by the device During Power Outage · Can use to turn lamps off

Initial Trouble Shooting

Problem
– Power not getting to the unit after plugging in. The LED AC light does not turn on.

Cause

What to do

– The power socket might not have any power.
– The junction is loose. – The AC fuse is blown.

– Check the 220-240VAC power supply.
– Check the junction. – Contact customer service.

– The unit and lamp does not illuminate when the power goes out

– The lamp is faulty – The circuit’s wiring is loose. – The DC fuse is blown

– The unit’s lamp only turns on for a short duration after the power has gone out.

– The battery is not fully charged. – The battery is past its operational

lifetime or has deteriorated

– Contact customer service. – Contact customer service. – Contact customer service.
– Take the unit to charge until the “LED Charge” indicator turns off.
– Contact customer service to replace the battery

3

Types Of Mounting Options SL SERIES

Ceiling (Type C) (installation without accessories)

Recessed (Type R) (installation without accessories)

Wall (Type W) (installation with kit included)

Suspended (Optional) (installation with kit not included)
EX SERIES

Ceiling (Type C) (installation without accessories)

Wall (Type W) (installation without accessories)

Flag (Type F) (installation without accessories)

Suspended (Optional)

(installation with kit not included)

4

Installation Steps SLS6-10LED (C) Step 1

Step 2

230

Step 3

Embed the anchor bolt and secure the slide rail into the ceiling.

Attach the exit sign to the slide rail.

SLS6-10LED (R)

Push the exit sign to the end of the rail as shown in the picture.
*Units are in millimeters.

Step 1

Step 2

Step 3

8 18.5

398
382 345

8 18.5

16 52 16 42
84

Drill holes in the ceiling as shown in the picture.
Step 4

Embed anchors bolt or fastening devices and secure screws into
the ceiling.

Use a screwdriver to disassemble the device as shown in the picture.

Step 5

Secure the top cover onto the ceiling.

Assemble the bottom cover onto the top cover.

*Units are in millimeters.

5

SLS6-10LED (W) Step 1

Step 2

230

Embed the anchor bolt and fasten the screw into the wall.

Attach the exit sign to the screw.

*Units are in millimeters.

Suspended (Optional)

Step 1

Step 2

Step 3

Assemble the mounting accessories for hanging on the slide rail.

Assemble the Hanger Rod with the mounting accessories.

Attach the exit sign to the slide rail. *Units are in millimeters.

6

EXS6-10LED (C) Step 1

Step 2

Step 3

205

2

1

Use a screwdriver to press the hanging hole.
EXS6-10LED (W) Step 1

Embed the anchor bolt and fasten the screw into the ceiling.

Attach the exit sign to the screw.

*Units are in millimeters.

Step 2

Step 3

205

Use a screwdriver to press the hanging hole.

Embed the anchor bolt and fasten the screw into the wall.

Attach the exit sign to the screw. *Units are in millimeters.

7

EXS6-10LED (F) Step 1

Step 2

40 145

Step 3
1

Remove the side panel.

Secure the box to the wall.

Suspended (Optional)

Step 1

Step 2

Insert the exit sign into the box. *Units are in millimeters.
Step 3
2 1

Drill the mounting accessories according to the size of the Hanger Rod.

Assemble the Hanger Rod with the mounting accessories.

Remove the screws from the device at positions 1 and 2.

Step 4

Assemble the device with the mounting accessories using the securing screws.
*Units are in millimeters. 8

Terms for Warranty and Service
1. The Warranty will only be covered if the customer fills in the “warranty registration form” and
mail the return part back to the company within 7 days from the day of purchase. If this is not
carried out the warranty will be considered void.
2. The warranty only covers the unit’s internal parts. The conditions and durations for the warranty of each part is as specified and the duration of the warranty is calculated from the date of purchase.
3. Please show your warranty card every time you contact our service center or the dealer you
purchased the product from. 4. Products that fall into the following category are considered not covered by the warranty.
The product was used in a way not specified in the manual. The product was used with accessories not meeting the required specifications specified in
the manual. The product seems to have been damaged from being dropped or from strong impact, for example, the parts are loose, dented, scrapped or misshapen. The product has been repaired or modified by personnel not authorized by our company.
The Warranty Void sticker is torn or removed. The product is damaged from careless use or incorrect maintenance, for example, the battery is swollen from overcharging, quick charging was used on the battery, the battery terminals have been short-circuited, the unit was used until the battery was completely discharged and not recharged immediately, the product was stored for long periods until the Battery Checker warning activates and still it is not plugged-in to charge or taking the battery to normal temperature conditions and not recharging it every 1 month. The product was stored in an unsuitable environment, for example, a location with moisture
or water vapor. The product was supplied with a faulty AC power supply such as electrical overvoltage, electrical current surges, or lightning strikes entering the AC power line. Damages from natural causes such as fire, being summered in fluids, humidity, chemicals or
force majeure. Damages from insects or animals.
Note : Please read the manual carefully before installation and operation to understand how to
properly operate the unit.

For any further questions about your product please feel free to contact SUNNY’s customer service department. Tel. (+66) 02-948-4450-2 E-mail: service@sunnyemergencylight.com

IsOn Import-Export Co., Ltd.
2915-2917 Ladprao Road, Klongjan, Bangkapi, Bangkok 10240

9

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Sunny User Manuals

Related Manuals