Satel WZ-110 Remote Alarm Indicator User Manual

September 24, 2024
Satel

WZ-110 Remote Alarm Indicator

“`html

Product Information

Specifications:

  • Model: WZ-110 EN

  • Manufacturer: SATEL

  • Designed for: Conventional or addressable fire alarm
    systems

  • Installation: Indoor spaces with normal air humidity

Product Usage Instructions

1. Installation:

  1. Disconnect power before making any electrical connections.

  2. Open the enclosure.

  3. Place the enclosure base against the surface and mark the
    location of mounting holes.

  4. Drill the holes for plugs (screw anchors).

  5. Run the cable through the hole in the enclosure base.

  6. Secure the enclosure base to the surface using plugs (anchors)
    and screws.

  7. Close the indicator enclosure.

2. Maintenance:

The WZ-110 indicator should be checked together with the
detector to which it is connected at least every 6 months. In
challenging environments, more frequent checks are recommended.

Ensure that the indicator LEDs are working by starting a
detector test in the control panel and testing the connected
detector. Check the control panel manuals for instructions on how
to start the test.

3. Specifications:

  • Conforms to essential requirements of National Technical
    Assessment CNBOP-PIB-KOT-2021/0268-1002 and EMC Directive
    2004/108/WE

  • Certificate and Declaration of Constancy of Performance
    available for download on www.satel.pl

FAQ:

Q: Can the WZ-110 indicator be used outdoors?

A: No, it is designed for indoor installation only.

Q: How often should maintenance checks be performed?

A: Maintenance checks should be carried out at least every 6
months, or more frequently in challenging environments.

“`

Remote alarm indicator
WZ-110 EN
wz-110_en 04/24 SATEL sp. z o.o. · ul. Budowlanych 66 · 80-298 Gdask · POLAND tel. +48 58 320 94 00
www.satel.pl

IMPORTANT
The device should be installed by qualified personnel. Prior to installation, please read carefully this manual in order to avoid mistakes that can lead to malfunction or even damage to the equipment. Disconnect power before making any electrical connections. Changes, modifications or repairs not authorized by the manufacturer shall void your rights under the warranty.
The following symbols may be used in this manual: – note, – caution.

The WZ-110 indicator LEDs are flashing when a detector or a group of detectors (at least one detector in the group) reports alarm. The indicator is designed for operation within conventional or addressable fire alarm systems.
1. Installation
Disconnect power before making any electrical connections. The indicator is designed for indoor installation, in spaces with normal air humidity. Select the place of installation so that the indicator is easily visible. 1. Open the enclosure (Fig. 1). 2. Place the enclosure base against the surface and mark the location of mounting holes
(Fig. 2). 3. Drill the holes for plugs (screw anchors). 4. Run the cable through the hole in the enclosure base (Fig. 2).
5. Using plugs (anchors) and screws, secure the enclosure base to the surface. Proper plugs must be selected for the type of mounting surface (different for concrete or brick wall, different for plaster wall, etc.).
6. Connect the wires to the corresponding terminals. Depending on the fire alarm system to which the indicator is to be connected: conventional: connect the terminal ­ [minus] to the terminal no 2 in the detector base, and the terminal + [plus] to the terminal no 3 or 4 in the detector base (Fig. 3), addressable: connect the terminal ­ [minus] to the terminal no 2 in the detector base, and the terminal + [plus] to the terminal no 1 in the detector base (Fig. 4).
7. Close the indicator enclosure.

2

WZ-110

SATEL

2. Maintenance
The fire alarm system elements require regular maintenance. The WZ-110 indicator should be checked together with the detector to which the indicator is connected. The periodic checks should be carried out at least every 6 months. In spaces where working conditions are difficult (e.g. dust, aggressive environment that may cause corrosion, etc.), the periodic checks should be carried out more often.

SATEL

WZ-110

3

As part of maintenance, make sure that the indicator LEDs are working. To do it, start a detector test in the control panel and test the detector to which the indicator is connected. Please go to the control panel manuals to find out how to start the test. Start of the test and test activation of devices will be registered in the control panel event log.

3. Specifications
Supply voltage …………………………………………………………………………………………..10…24 VDC Average current consumption (from the detector)…………………………………………………..0.4 mA IP code……………………………………………………………………………………………………………… IP 3X Flashing frequency …………………………………………………………………………………………….2.4 Hz Operating temperature range…………………………………………………………………….-10°C…+55°C Maximum humidity ……………………………………………………………………………………………. 93±3% Enclosure dimensions…………………………………………………………………………..84 x 84 x 30 mm Weight………………………………………………………………………………………………………………… 56 g

4

WZ-110

SATEL

The WZ-110 remote alarm indicator conforms to the essential requirements of the National Technical Assessment CNBOP-PIB-KOT-2021/0268-1002 (first edition of 30.06.2021) and the essential requirements of the directive:
EMC 2004/108/WE Electromagnetic Compatibility Directive.
The CNBOP-PIB Certification Body in Józefów issued the Certificate of Constancy of Performance 063-UWB-0366 for the WZ-110 type remote alarm indicator, confirming its compliance with the requirements of the National Technical Assessment.
The Certificate can be downloaded from the www.satel.pl website.
The National Declaration of Constancy of Performance no. 063-UWB-0366 of 2021-08-24 for the WZ-110 type remote alarm indicator can be downloaded from the www.satel.pl website.

SATEL

WZ-110

5

21
SATEL Sp. z o.o. · ul. Budowlanych 66 · 80-298 Gdask · POLAND Certificate No. 063-UWB-0366
The National Technical Assessment CNBOP-PIB-KOT-2021/0268-1002 (first edition of 30.08.2021)
Name and type: WZ-110 type remote alarm indicator Intended use: Fire safety ­ devices for use in buildings.

Essential characteristics of the construction product
for the intended use Design requirements Labelling requirements Signaling by the remote alarm indicator
Visibility of the remote alarm indicator
Resistance to cold
Resistance to dry heat
Resistance to sulfur dioxide corrosion
Resistance to impact
Resistance to steady damp heat
Protection against the ingress of foreign bodies provided by the enclosure
Immunity to electrostatic discharge RF electromagnetic field immunity Immunity to electrical fast transients/bursts
Surge immunity Immunity to conducted disturbances inducted by
radio frequency fields

Declared performance

Notes

pass pass pass pass
pass pass pass
pass pass
pass

pt. 3.3 of the National Technical Assessment
pt. 3.1 of the National Technical Assessment
The remote alarm indicator LEDs flash to signal the alarm condition of the detectors connected to
it.
The remote alarm indicator powered from the detector, with background illuminance up to 500 lx, is visible from a distance of 6 m directly in front of
the indicator.
Temperature: -10°C (± 3°C) Endurance: 16 hours
Temperature: +55 (± 2°C) Endurance: 16 hours
Temperature: +25 (± 2°C) Relative humidity: 93% (± 3%) SO2 concentration: 25 ppm (± 5 ppm) Endurance: 504 hours (21 days)
Impact energy: 0.5 J (±0.04J) Number of impacts per point: 3
Temperature: +40°C (± 2°C) Relative humidity: 93% (± 3%) Endurance: 96 hours (4 days)
IP 3X

pass pass pass pass pass

PN-EN 50130-4:2012 + A1:2015-03 PN-EN 50130-4:2012 + A1:2015-03 PN-EN 50130-4:2012 + A1:2015-03 PN-EN 50130-4:2012 + A1:2015-03 PN-EN 50130-4:2012 + A1:2015-03

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>