Ovente ST2010 CYCLONIC VACUUM INSTRUCTION MANUAL
- September 20, 2024
- OVENTE
Table of Contents
Ovente ST2010 CYCLONIC VACUUM
Thanks for purchasing this product. Please read the instruction manual carefully before operation and well preserve it.
SAFETY DIRECTIONS
- Check before operation that the local power supply is the same as the specifications on the rating plate.
- Do not use the vacuum cleaner to suck glowing ash, glowing cigarettes or matches, water, damp dust, etc.
- don’t let children play with this machine.
- Please unplug the cleaner from the supply before cleaning it.
PARTS NAME
- Floor brush For carpet and wooden floor, etc.
- Crevice nozzle For corners, cracks, etc. Bristle brush
- For sofa, bookshelf, curtain and furniture, etc.
OPERATION METHOD
-
Insert the hose connector into the swivel of the Vacuum Cleaner.
-
Insert the handle into the tube with a twisting force.
-
Same as above.
-
Same as above.
-
Standing position
Put the fixing block into the hole on the body. -
(1)Pull out the cord as long as you need, but do not exceed the mark of red and yellow.
-
(2)Hold the plug when rewinding, you can press the button with your foot to retract the cable into the machine.
-
(1)Press the switch button to turn on/off the cleaner.
-
You can adjust the airflow by push the sliding block up and down.
Warning: This machine is a cyclonic design, no dust bag filted. The LED dust indicator will light up when the dust conainer is full, or the filters are clogged. You can follow below MAINTENANCE instructions to resolve this problem.
MAINTENANCE
Dust cup maintenance: Please always Keep the dust cup clean before each
operation.
You can wash the cup in water whenever necessary.
-
Press the locking block, then push front to open the dust compartment
-
Take up the dust compartment
-
To clean, turn the dust compartment upside down.
Press the automatic release black button and open the gray cover. Twist counterclockwise to take the filter out and twist clockwise to lock. -
Push the dust compartment down to fix it on the body.
Note:- Dusts will be present.
- Clean the filter by washing it.
- Make sure the filter is dry before placing back in the vacuum
- Close the gray lid and reattach it on the vacuum.
Filter maintenance
- Take out the central HEPA filter and wash by running water,just as above picture shows.
- Assemble the dried accessories as shown in the picture. NOTE:
- Filter has to be connected on the
- Unlock sign has to be matching with the down arrow.
- Once aligned, twist the lid to the right to lock it.
- Take out the exhaust filter tapping it or washing in running water drying naturally then put it back.
CAUTION
- Don’t pull the cord to unplug, when you would like to retract the cable, hold the plug and then press the rewinder button.
- Don’t suck at large fragments or sharp objects.\
- Keep off from ovens and stoves, etc.
- Don’t wrest, tramp and haul the hose.
Warning:
- Never use this machine when the suction power becomes very weak. When this happens, please check HEPA if they are dirty(see MAINTENANCE); Lastly check the floor brush, tube, and hose to see if any part is jammed.
- Don’t use the machine until it becomes normal. If the problem remains, please submit to the Repairing Center.
- If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similarly qualified person to avoid a hazard.
FAQs
What is the power rating of the Ovente ST2010?
The Ovente ST2010 has a power rating of 1200W, ensuring powerful suction for effective cleaning.
What type of filter does the Ovente ST2010 use?
The Ovente ST2010 is equipped with a HEPA filter, which removes 99.9% of dust and allergens from the air.
How does the automatic cord rewind feature work on the Ovente ST2010?
The Ovente ST2010 automatically rewinds the cord for easy storage, eliminating clutter and making cleanup more convenient.
What accessories come with the Ovente ST2010?
The Ovente ST2010 comes with an accessory kit that includes a dusting brush and a crevice tool for versatile cleaning options.
What is the weight of the Ovente ST2010?
The Ovente ST2010 weighs approximately 12 pounds, making it relatively lightweight and easy to maneuver.
What kind of maintenance does the Ovente ST2010 require?
The Ovente ST2010 requires regular cleaning or replacement of the HEPA filter and emptying the dust container after each use.
How does the suction power of the Ovente ST2010 compare to other vacuums?
The Ovente ST2010's powerful 1200W motor provides strong suction, often outperforming many standard vacuums in its category.
What is the length of the power cord on the Ovente ST2010?
The Ovente ST2010 features a 15-foot power cord, providing ample reach for cleaning large areas without frequent outlet changes.
What is the capacity of the dust container on the Ovente ST2010?
The dust container has a capacity of 2.0 liters, allowing for extended cleaning sessions before needing to be emptied.
How does the HEPA filter work in the Ovente ST2010?
The HEPA filter traps small particles and allergens, preventing them from being released back into the air during vacuuming.
Video-Ovente ST2010 CYCLONIC VACUUM
Download this Manual:Ovente ST2010 CYCLONIC VACUUM INSTRUCTION MANUAL
Reference Link
Ovente ST2010 CYCLONIC VACUUM INSTRUCTION MANUAL- Device.report
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>