“`html
Specifications:
- Product: Steambath Generator Systems
- Manufacturer: MrSteam
- Model Number: PUR100378 5.22
- Address: 43-20 34th Street, Long Island City, NY 11101
- Contact: TEL: 1-800-76-STEAM
Product Information:
The Steambath Generator Systems by MrSteam provide a luxurious
steam experience in the comfort of your own home. It is designed to
generate steam for steam rooms, creating a relaxing and
rejuvenating environment.
Installation Instructions:
-
Read the entire Installation, Operation, and Maintenance Manual
carefully. -
Ensure all safety precautions are followed during
installation. -
Place the steambath generator in a suitable location with
proper ventilation. -
Connect the generator to the water and electrical supply
following the provided guidelines. -
Test the system to ensure it is functioning correctly before
regular use.
Operation Instructions:
-
Read and understand all safety instructions provided in the
manual. -
Supervise children at all times when using the steam room.
-
Avoid direct contact with hot surfaces like the steam
head. -
Limit steam usage to prevent overheating and ensure proper body
temperature regulation.
Maintenance Instructions:
-
Regularly clean and descale the steambath generator as per the
maintenance guidelines. -
Check for any leaks or malfunctions and address them
promptly. -
Follow the recommended maintenance schedule provided by the
manufacturer.
FAQ:
Q: Can I use alcohol in the steam room?
A: No, using alcohol in conjunction with the steam room can be
dangerous and increase the risk of injury through slipping and
falling.
Q: What should I do if I feel uncomfortable or dizzy in the
steam room?
A: Exit the steam room immediately as staying too long in a
heated area can cause overheating. Consult a doctor if
necessary.
Q: How often should I clean the steambath generator?
A: The steambath generator should be regularly cleaned and
descaled as per the maintenance guidelines provided by the
manufacturer.
“`
Installation, Operation and Maintenance Manual
Steambath Generator Systems
Residential Models: MS90E MS400E and MSSUPER1E 3E
____ ____ IMPORTANT: Leave this material with
the home owner.
mr.steam®
Feel Good Inc.®
READ ME FIRST!
As you follow these instructions, you will notice warning and caution symbols.
This blocked information is important for the safe and efficient installation
and operation of this generator. These are types of potential hazards that may
occur during installation and operation:
Indicates a potentially hazardous situation, which, if not avoided, could
result in death or serious injury.
Indicates a potentially hazardous situation, which, if not avoided may result
in minor or moderate injury or product damage.
is used to address practices not related to physical injury.
IMPORTANT NOTE: This highlights information that is especially relevant to a
problem-free installation.
All information in these instructions is based on the latest product
information available at the time of publication. MrSteam reserves the right
to make changes at any time without notice. More current instructions may be
available at www.mrsteam.com.
When installing and using this electrical equipment, basic safety precautions should always be followed, including the following:
IMPORTANT SAFETY INSTRUCTIONS 1. READ AND FOLLOW ALL INSTRUCTIONS
-
Supervise children at all times.
Steam is hot and can
cause injury or death if improperly used.
Steam rooms contain steam and elevated
temperatures. Please read and observe all
warnings in this manual before installing
or using a steam room.
- To reduce the risk of injury: A. The wet surfaces of steam enclosures may be slippery. Use care when entering or leaving. B. The steam head is hot. DO NOT touch the steam head and avoid the steam near the steam head. C. Prolonged use of the steam system can raise excessively the internal human body temperature and impair the body’s ability to regulate its internal temperature (hyperthermia). Limit your use of steam to
10-15 minutes until you are certain of your body’s reaction. D. Excessive
temperatures have a high potential for causing fetal damage during the early
months of pregnancy. Pregnancy or possibly pregnant women should consult a
physician regarding correct exposure. E. Obese persons and persons with a
history of heart disease, low or high blood pressure, circulatory system
problems, or diabetes should consult a physician before using a steambath. F.
Persons using medication should consult a physician before using a steambath
since some medication may induce drowsiness while other medications may affect
heart rate, blood pressure and circulation.
SAVE THESE
INSTRUCTIONS
! WARNING
REDUCE THE RISK OF OVERHEATING AND SCALDING
1. EXIT IMMEDIATELY IF UNCOMFORTABLE, DIZZY OR SLEEPY. STAYING TOO LONG IN A
HEATED AREA IS CAPABLE OF CAUSING OVERHEATING.
2. SUPERVISE CHILDREN AT ALL TIMES. 3. CHECK WITH A DOCTOR BEFORE USE IF
PREGNANT, DIABETIC, IN POOR HEALTH OR UNDER
MEDICAL CARE. 4. BREATHING HEATED AIR IN CONJUNCTION WITH CONSUMPTION OF
ALCOHOL, DRUGS, OR
MEDICATION IS CAPABLE OF CAUSING UNCONSCIOUSNESS. 5. DO NOT CONTACT STEAM HEAD
OR STEAM AT THE STEAM HEAD.
REDUCE THE RISK OF SLIPPING AND FALL INJURY
1. USE CARE WHEN ENTERING OR EXITING THE STEAM ROOM. FLOOR MAY BE SLIPPERY
NOTE: FOR ADDITIONAL SAFETY CONSIDERATIONS SEE OWNER’S MANUAL WHICH IS
KEPT:___ THE OWNER’S MANUAL CAN BE FOUND
AT WWW.MRSTEAM.COM USE OF STEAM ROOM IN CONJUNCTION WITH CONSUMPTION OF
ALCOHOL CAN BE DANGEROUS AND CAN RESULT IN INJURY THROUGH SLIP AND FALL OR
OTHERWISE.
43-20 34th Street , Long Island City, NY 11101 · 1 800 76 STEAM ·
www.mrsteam.com
PUR100378 5.22
®
mr.steam hello@mrsteam.com · www.mrsteam.com
43-20 34th Street, Long Island City, NY 11101 TEL: 1 800 76 STEAM 9410 S. La
Cienega Blvd. Inglewood, CA 90301 TEL: 1 800 72 STEAM
1
HYPERTHERMIA occurs when the internal temperature of the body reaches a level
several degrees above the normal body temperature of 98.6° F. The symptoms of
hyperthermia include an increase in the internal temperature of the body,
dizziness, lethargy, drowsiness, and fainting. The effects of hyperthermia
include: a) Failure to perceive heat; b) Failure to recognize the need to exit
the steambath; c) Unawareness of impending risk; d) Fetal damage in pregnant
women; e) Physical inability to exit the steambath and f) Unconsciousness.
The use of alcohol, drugs, or medication can greatly increase the risk of
hyperthermia
The peel and stick warning label is an essential part of providing a safe
environment for steam room users. The peel and stick warning label is supplied
with the instruction manual provided with the steam generator and must be
applied to the wall of the shower or steam enclosure, at a point that is
visible to all users. Failure to install this sticker may result in serious
injury or death.
PUR 100472A REV 6.24
Designed, Engineered and Assembled in the
USA
RESIDENTIAL STEAMBATH GENERATOR SYSTEMS
INSTALLATION, OPERATION & MAINTENANCE MANUAL
MODELS: MS90E, MS150E, MS225E, MS400E, MSSUPER1E, MSSUPER2E, MSSUPER3E
TABLE OF CONTENTS
Important Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . .
. . . .1 Select Your MrSteam Model . . . . . . . . . . . . . . . . . . . . . .
. . . . . . .3 Generator Specification Chart . . . . . . . . . . . . . . . . .
. . . . . . . . . .3
INSTALLER SECTION
Before Installing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . .4 Steam Room Guidelines . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . 4 Water Quality Information . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . .5 Locating the Steam Generator . . . . .
. . . . . . . . . . . . . . . . . . . . . .5 Typical Installation Instructions
. . . . . . . . . . . . . . . . . . . . . . . . . . .6 Typical Multi-Unit
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
Installation: Plumbing, Water Supply, Drain, Steam Outlet
Safety Valve, Condensation Pan, AromaSteam . . . . .8 AromaSteam Steamhead
Installation . . . . . . . . . . . . . . . . . . . . . .9 Steam Generator
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . .10 Electrical
Specifications & Field Power Wiring . . . . . . . . . . . . . .11 Wiring
Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
.12-13 Optional Tandem Cable Diagram . . . . . . . . . . . . . . . . . . . . .
. . .13 Initial Start-Up & Checkout . . . . . . . . . . . . . . . . . . . . .
. . . . . . . .14 Optional & Accessary Equipment . . . . . . . . . . . . . . .
. . . . . . . . .14 Troubleshooting . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . .14 System Status Codes . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . .15 Liquid Level Control Board . . .
. . . . . . . . . . . . . . . . . . . . . . . . . .15 Optional AutoFlush
System . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16 Optional
Condensation Pan . . . . . . . . . . . . . . . . . . . . . . . . . . . .17
Optional Express Steam . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . .17 Parts Identification Diagrams . . . . . . . . . . . . . . . . . . . .
. . . . . . .18 Replacement Parts List . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . .19
CONTROL INSTALLATION
Before Installing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . .20 Control Rough-In . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . .20
HOMEOWNER SECTION
Important Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . .
. . .21 Setting Steam Bath Temperature & Duration . . . . . . . . . . . . . .
. 22 Safety & Operating Info . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . .22 Care Tips for Controls and Generator Maintenance . . . . . . . .
. .22 Using the AromaSteam Essential Oils . . . . . . . . . . . . . . . . . .
. . .23 Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . .23
mr.steam®
Feel Good Inc.
2
MODEL ____ SERIAL NO.
I N STA L L E R
Installation, Operation & Maintenance Manual
SELECT YOUR MrSteam
MrSteam @ Your Fingertips: Start working smarter with MrSteam’s mobile sizing
app, now available for the iPad®, iPod® and most smart phones. Visit
mrsteam.com to size your generator automatically or go directly to:
http://isizing.mrsteam.com
Materials of construction, room size and special design features such as large glass areas, all affect the steam generator model selection.
1. Measure length, width & height in feet of the steam/shower or tub/shower
Multiply the Length x Width____ x Height =
ROOM VOLUME
2. Construction Materials:
For ceramic or porcelain tile on cement board or mortar bed
For natural stones: natural marble, stone, shale, glass block or concrete
For acrylic or fiberglass subtract
3. Ceiling Height: For each foot above 8 feet (max 10 feet)
Add 0% Add 50% Subtract 40% Add 15 to the volume with material ad ustment
4. Total Room Volume
Compare your Room Volume to the Chart below and select the appropriate model.
In considering the purchase or use of this steambath system, please note that
if you are pregnant, have a coronary condition, are in poor health, are being
treated for any other medical condition, or are using medication or drugs,
MrSteam recommends that you obtain the approval of a physician before use.
For information about this product and safety issues, please call
1.800.76.STEAM
IMPORTANT NOTES: For steam rooms constructed of acrylic or synthetic
materials, select next lower-rated MS model.
The MrSteam Sizing Chart allows for up to 60 feet of insulated steam piping
from the MS generator to the steam room. If the 60 foot steam piping is
exceeded consult with factory. The steam generator control locations must be
taken into account. A 30 foot cable is standard. Contact MrSteam to purchase
an optional 60 ft. cable PN 103990-60 for iTempo® and AirTempo® and PN
104117-60 for iSteam®. The maximum cable length is 60 feet.
RESIDENTIAL STEAM GENERATORS SPECIFICATION CHART
Model No. MS90E MS150E MS225E MS400E
Amps (for KW 240v/1PH)
5
21
6
25
7.5
32
9
38
Wire Size
10 8 8 8
Total Adj. Room Vol.
0-71 72-107 108-161 162-257
Water Usage Gallons 0.67 0.80 1.0 1.2
Dimensions* 14 “L x 14 “H x 6 “D 14 “L x 14 “H x 6 “D 14 “L x 14 “H x 6 “D 14 “L x 14 “H x 6 “D
Shipping Wt. (lbs)**
27 27 27 27
MSSUPER1E
10
42
MSSUPER2E
12
50
MSSUPER3E
15
63
8
258-339
6
340-411
4
412-482
1.4
17″L x 18 “H x 77/8″D
39
1.6
17″L x 18 “H x 77/8″D
39
2.0
17″L x 18 “H x 77/8″D
39
IMPORTANT NOTES:
- Dimensions are for generator only, without
· Add C1 suffix to Model No. for 240V/1Ph; Add B1 suffix to
AutoFlush® or plumbing features
Model No. for 208V/1Ph
** Shipping weight & pricing are for generator
· All MrSteam MS Models are cULus Listed and CE approved
only, without control or steamhead
Water usage based on 20 minutes of
operation
All MS Generators available in 240v/1PH, 208v/1PH and other voltages/phases
Amps are for 240/1PH rated units
Wire size (AWG) based on minimum 90°C rated THHN copper conductors
Refer to the National Electrical Code for other types of conductors
See MrSteam Installation and Operation Manual for complete dimensional and
installation information
3
I N STA L L E R
Not actual size
Installation, Operation & Maintenance Manual
BEFORE INSTALLING
Carefully inspect the Steam Generator and packaging for shipping damage. In
the event of shipping damage, please contact the carrier for claim
information. Our customer service department can assist you with any missing
or damaged parts.
Read these instructions before installation or service. Although this MS
steambath generator has been fully qualified for shipment by MrSteam®, the
following must be reviewed for proper, safe and enjoyable steam bathing: 1.
Verify that the model and accessories specifications are
correct for the incoming line voltage. 2. Insure steambath generator has been
correctly sized for the
steambath room. Pay particular attention to room volume and construction. If
any questions, please refer to MrSteam sizing and selection guide on page 3.
3. Marble or glass walls or ceilings. “ENLARGE” the room’s size, requiring a
generator larger than one based only on the room’s cubic foot (L x H x W)
volume.
4. The physical size of the unit, clearance for plumbing servicing, and its
distance from the steam room must all be considered before final installation.
5. Consider any controls and accessories before initiating installation. Read
the Installation and Operation Manual of all controls and accessories
available at www.mrsteam.com technical downloads.
Record the serial number of the steam
generator in the space provided in the table of contents
of this manual.
STEAM ROOM GUIDELINES
1. Steam room must be completely enclosed, with full walls, door, floor and
ceiling.
2. It is recommended that a gasketed door is used for steam containment.
To prevent slip and fall hazard, nonslip flooring,
nonslip floor strips, or tiles designed for floors must be installed in
the steam room.
4. Check the suitability of any materials with the manufacturer.
Walls and ceilings must be constructed of water-resistant,
non-corrosive surface, such as tile, marble, molded acrylic, or
other non-porous material.
5. The ceiling should be sloped to prevent dripping of condensate.
6. Provide a floor drain.
7. No heating, venting or air conditioning devices should be
installed inside the steam room.
8. Steam room tile construction information is available from the
Tile Council of America, Inc. by purchasing the TCA
Handbook for Ceramic Tile Installation. Tel. 864-646-8453 or
www.tileusa.com.
9. Windows that are part of the steam room should be double
paned and tempered safety glass.
10. Limit steam room ceiling height to 8 feet. Exceeding 8 feet
may require a higher-rated steam generator.
The peel and stick warning label located in the manual is an essential part of
providing a safe environment for steam room users. The peel and stick warning
label must be applied to the wall of the shower or steam enclosure, at a point
that is visible to all users. Failure to install this sticker may result in
serious injury or death. The location where this owner’s manual is kept shall
be written in the space provided on the label using permanent ink. For a
replacement warning label contact MrSteam customer service at 1-800-76-STEAM
or hello@mrsteam.com
! WARNING
REDUCE THE RISK OF OVERHEATING AND SCALDING
1. EXIT IMMEDIATELY IF UNCOMFORTABLE, DIZZY OR SLEEPY. STAYING TOO LONG IN A
HEATED AREA IS CAPABLE OF CAUSING OVERHEATING.
2. SUPERVISE CHILDREN AT ALL TIMES. 3. CHECK WITH A DOCTOR BEFORE USE IF
PREGNANT, DIABETIC, IN POOR HEALTH OR UNDER
MEDICAL CARE. 4. BREATHING HEATED AIR IN CONJUNCTION WITH CONSUMPTION OF
ALCOHOL, DRUGS, OR
MEDICATION IS CAPABLE OF CAUSING UNCONSCIOUSNESS. 5. DO NOT CONTACT STEAM HEAD
OR STEAM AT THE STEAM HEAD.
REDUCE THE RISK OF SLIPPING AND FALL INJURY
1. USE CARE WHEN ENTERING OR EXITING THE STEAM ROOM. FLOOR MAY BE SLIPPERY
NOTE: FOR ADDITIONAL SAFETY CONSIDERATIONS SEE OWNER’S MANUAL WHICH IS
KEPT:___ THE OWNER’S MANUAL CAN BE FOUND
AT WWW.MRSTEAM.COM USE OF STEAM ROOM IN CONJUNCTION WITH CONSUMPTION OF
ALCOHOL CAN BE DANGEROUS AND CAN RESULT IN INJURY THROUGH SLIP AND FALL OR
OTHERWISE.
43-20 34th Street , Long Island City, NY 11101 · 1 800 76 STEAM ·
www.mrsteam.com
PUR100378 5.22
Never use damaged equipment, doing so may result in an inoperative or
hazardous installation. · Discontinue use of the steam generator and control
if the
steam generator or control are damaged or otherwise not functioning properly.
Doing so may result in an inoperative or hazardous installation · ELECTRICAL
SHOCK HAZARD. MrSteam steam generators are connected to 208V or 240V line
voltage and contain live electrical components. All installation and service
to be performed by qualified and licensed electricians and plumbers only.
Installation or service by unqualified persons or failure to use MrSteam parts
may result in property damage or in a hazardous condition. · The MS series of
steam generators are for residential use only. Commercial or other
nonresidential applications void the warranty and may adversely affect product
performance and may represent a safety hazard.
4
If acrylic, fiberglass or other non-heat resistant materials are used as part of the steam room enclosure. Consult with the material manufacture and see pg. 9, “Installing the Steamhead” for additional details. IMPORTANT NOTES: This document contains important safety, operation and maintenance information. Leave this document with the homeowner. Do not discard this document. The following general information should be used in conjunction with consultations with an architect, designer and contractor in determining factors necessary in providing a suitable and safe steam room. MrSteam steam generators are intended to be operated with MrSteam iSteam®, AirTempo®, iTempo/Plus®, iTempo® Home Wizard® and iGenie® controls only, and are to be installed strictly in accordance with the specific instructions contained in this manual and as supplied in the manuals provided with the controls or accessories.
I N STA L L E R
Installation, Operation & Maintenance Manual
WATER QUALITY INFORMATION
For optimum results, the water supply should be tested prior to installation.
If the mineral content exceeds the following recommended limits, various
external treatment processes are recommended to correct the problem.
An analysis of the on-site water must be made by a recognized and reliable
water treatment company to ascertain the existing condition and treatment
required.
Poor water quality can affect efficiency or result in steam generator damage.
Water contains impurities in solution and suspension. These impurities
concentrate in the generator. The concentration of these impurities increases
as more feedwater is introduced into the generator and steam is produced. If
the suspended solids are allowed to concentrate beyond certain limits, a
deposit or “scale” will form on the generator internal surfaces. This deposit
can interfere with the proper generator operation and cause generator failure.
The concentration of these impurities is generally controlled by the water
quality and by periodic draining of the generator.
RECOMMENDED FEEDWATER QUALITY
Hardness, ppm 8 85 (~0.5 5 gpg) P-Alkalinity, ppm 85 410 (~5 24 gpg)
T. Alkalinity, ppm 200 500 (~7 0 gpg) pH (strength of alkalinity) 8.0
11.4
Every 2 months, or more often in “hard” water areas, the manual drain valve
should be opened fully flushing out accumulated materials, salts and other
particles which are natural by-products of boiling water. The optional
AutoFlush System feature automatically drains the MrSteam® generator following
each use. A time delay allows the water to cool down (about two hours) before
it drains by gravity for a safe and gentle operation.
LOCATING THE STEAM GENERATOR
Select a location as near as practical to the steam room.
Typical locations include: closet, vanity cabinet, heated attic or basement.
The standard length of the cable for connecting the control to the steam generator is 30 feet. The steam generator and control must be located accordingly. A 60 foot cable is available as a special order part for iTempo® and AirTempo®, PN 103990-60 and PN 104117-60 for iSteam®. The maximum cable length is 60 feet. IMPORTANT NOTE: The control cable should be run in a dedicated 1″ conduit to facilitate installation and service.
DO NOT route iSteam, AirTempo, iTempo/Plus, iTempo, HomeWizard or iGenie control wiring inside conduit together with power lines or close to hot water or steam piping. Doing so may result in an inoperative or hazardous installation.
(Items 1-4) 1. DO NOT install steambath generator inside steam room, a
shock hazard will occur 2. DO NOT install steambath generator outdoors or
wherever environmental conditions may result in a shock hazard or affect
performance of the generator. 3. To prevent damage to the steam generator or a
fire hazard DO NOT install steambath generator near flammable or corrosive
materials or chemicals such as gasoline, paint thinners, or the like.
Installation in areas having high concentrations of chlorine (such as pool
equipment room) must be avoided. 4. Burn Hazard. Steam piping, safety valve,
drain valve and plumbing become hot during operation and remain hot after
shutdown for a period of time. Provide appropriate protection, including
insulating plumbing lines. Avoid plumbing runs and steamhead locations that
can come in contact with bathers.
(Items 5-7) 5. DO NOT install steambath generator or plumbing lines in
unheated attic or any locations where water could freeze and cause pipes to
rupture and cause property damage. 6. Install steambath generator on a solid
and level surface. Provide supports under steam generator when wall mounting.
Keyhole slots are provided for wall mounting.
Insure the steam generator is properly secured and level when mounting with
keyhole slots to prevent damage to the steam generator. 7. Install steambath
generator in an upright position only to prevent damage to the generator.
IMPORTANT NOTES: (Items 8-12) 8. Install anti-water hammer device as
necessary. 9. Provide a minimum of 12 inches at both ends and top of
the steam generator or as required for servicing. See page 10. 10. Provide
unions as required to facilitate installation and
disconnection of piping. 11. MrSteam controls can be located inside the steam
room
or on the outside of the steam room. See the Control Installation Manual for
your specific control package for specific details. 12. The MS series of steam
generators are for residential use only. Commercial or other nonresidential
applications void the warranty and may adversely affect product performance
and may represent a safety hazard.
MrSteam Generators (inclusive of the iTempo, AirTempo and iSteam series
Controls) are CE and UL listed.
Suitable for operation in ambient not exceeding 45 °C (113° F)
5
I N STA L L E R
Installation, Operation & Maintenance Manual
TYPICAL MrSteam INSTALLATION
Provide unions as required to facilitate installation and disconnect of piping
FiFeiledldiinnssttaalllleedd popowweer suupppplyly
FieFiledldiinnssttallleedd wawtaeterrssuupppplylylinliene
Drawings for illustrative purposes only. Consult with qualified designer, architect or contractor for steam room construction details.
The control features an integral temperature sensor. Locate the control in a
location representative of the desired steam bathing temperatures. Do not
locate the control above or near the steam head or direct steam emissions.
Control cable run in 1″ conduit (located behind the wall)
iSteam®, AirTempo® or iTempo/Plus® Control Refer to Control Installation Manual for installation information
Steam Generator
Drain Valve must be closed when the optional AutoFlush is not installed
FieFlideldininssttaalllleedd stesatemamppiippiinngg
Steam Head (shown with optional acrylic shield) See page 9 for Steamhead Installation information
When installing the optional AromaSteam, install a 90-degree T in the steam piping. See the AromaSteam Installation Manual for complete information.
To avoid unintentional steambath operation, do not locate the control where other controls, accessories, shower heads, valves, body sprays or similar within the shower could cause confusion or interfere with the MrSteam control’s intended use and function.
All drawing are for illustrative purposes only
6
I N STA L L E R
Installation, Operation & Maintenance Manual
TYPICAL MULTI-UNIT INSTALLATION
(shown with optional AutoFlush)
1. Install each steam generator as in a single installation. Install generators as close as practical to each other, not exceeding 10 feet. The interconnecting cable length is 12 feet.
Shock Hazard. Power must be disconnected at the main
electrical supply. Remove steam generator covers. Retain screws and covers
for reuse.
3. Connect the iSteam®, iTempo/Plus® or AirTempo® control to either unit as per the Installation Manual supplied with each control. The control must be connected to the primary unit.
4. Remove one knock-out on each generator as shown. Insert the ends of interconnecting cable provided (PN 103904) through the knock-outs as shown in diagram. Connect each end to the printed circuit board connector labeled “TANDEM” as shown.
5. Prevent the interconnecting cable from contacting hot surfaces such as steam outlet, safety valve and the like.
6. Connect separate plumbing and power supplies for each unit. Replace covers with cover screws.
7. Provide unions as required to facilitate installationand disconnection of piping
The secondary unit will de-energize when the steam room reaches steam bathing temperature resulting in a more gentle and energy efficient operation.
All drawing are for illustrative purposes only
7
I N STA L L E R
Installation, Operation & Maintenance Manual
INSTALLATION
PLUMBING
All plumbing shall be performed by a qualified licensed plumber and in
accordance with applicable National and local codes. 1. Use unions on all pipe
connections. 2. Use only brass piping or rigid copper tubing as permitted
by codes. 3. DO NOT use black, galvanized, PVC pipe or PEX except
as noted below.
Water supply and steam piping must be flushed to remove flux and other debris
prior to connecting the steam generator. Failure to flush the steam piping may
result in flux poisoning or a hazardous condition. Failure to flush the steam
piping may result in blockage or an inoperable system.
WATER SUPPLY (3/8″ NPT)
1. Connect to cold water line.
AROMASTEAM
If the optional AromaSteam Electronic Oil Delivery System (PN: MS AROMA) is to
be installed, a 90 degree T plumbing fitting must be installed at a designated
location on the steam piping. See the MrSteam AromaSteam Operation and
Instruction Manual for installation information before the steam piping is
installed at the technical downloads section of www.mrsteam.com
STEAM PIPING (1/2 NPT)
1. DO NOT install any valve in steam piping. Flow of steam must be
unobstructed.
2. Use 1/2-inch brass pipe or copper tubing from unit to steam head as
permitted by codes.
3. Insulate steam piping with fiberglass pipe insulation or similar
insulation rated 212° F or higher.
4. Pitch steam piping1/4″ per foot towards steam head or steam generator to
avoid valleys and trapping of condensate.
Water feed line may be flexible copper tubing, braided hose, PVC or PEX if
permissible by local codes. 2. Provide a shut off valve in the water supply
line upstream of the steambath generator. 3. DO NOT overheat inlet solenoid
valve with solder connections. Overheating will damage parts. 4. Flush inlet
water line thoroughly before making connection to unit. 5. Strainer
recommended upstream of feed water connection. 6. In order to reduce operating
noise, reducing feed water pressure to between 15 – 20 psi is recommended.
Optional pressure reducing valve part number 104198. 7. Provide anti-water
hammer device as required. 8. Install an approved backflow preventer as
required by local codes.
DRAIN (1/2″ NPT)
Failure to pitch the steam piping as required for condensate to drain, may
cause condensate to block the flow of steam. Blocking the steam flow may cause
steam pressure to discharge boiling water through the steamhead, resulting in
a scalding hazard. Blocking the flow of steam may cause steam to discharge
through the safety valve, resulting in a scalding hazard.
A 1.5″ hole in the steam room is required to mount the steamhead. For Linear
steamhead, please refer to the installation instructions.
The drain from the generator should not share an under sink trap, unless the
generator is mounted higher than the sink to prevent damage to the generator
if the drain backs up.
A drain valve is provided to facilitate servicing. Provide a drain line
connection from steambath generator drain valve according to National and
local Codes. Check local plumbing code for receptor, trap and vent
requirements. DO NOT connect Drain line and Safety Valve line together. Unit
drains by gravity.
DO NOT plumb the generator drain and condensation pan drain together in such a
way that will cause drain water to back into condensation pan. DO NOT drain
into a steam enclosure or any location where accidental contact with drain
water may occur. In the event of a power failure the AutoFlush System valve
will open and may discharge boiling water causing a scalding hazard.
SAFETY VALVE (3/4″ NPT)
Where permitted by local codes, provide an outlet plumbing connection for
safety valve.
To insure proper and automatic safety valve operation: DO NOT connect a shut
off valve or a plug at safety valve outlet. DO NOT connect a shut off valve or
any obstruction in steam supply pipe. DO NOT connect the safety-valve output
into the steam piping.
CONDENSATION PAN
MrSteam strongly recommends the use of a condensation pan in the unlikely
event of a plumbing leak. Check local plumbing codes for receptor, trap and
vent requirements. Condensation pans drain by gravity. The condensation pan is
equipped with an integral 3/4″ fitting. See page 17 for additional
condensation pan installation information.
Do not plumb the generator drain and condensation pan drain together in such a
way that will cause drain water to back into condensation pan.
DO NOT connect the drain valve to the steam piping.
8
All drawing are for illustrative purposes only
I N STA L L E R
Installation, Operation & Maintenance Manual
INSTALLING THE ROUND OR SQUARE AROMASTEAM STEAMHEAD (1/2″ NPT)
A 1 1/2″ clearance hole around the steam pipe is needed to mount the
steamhead.
Use Teflon® or equal sealant on
pipe threads
STEP 1
Steam Piping
Locate steam head 6-12 inches above floor, except for:
1. Tub/shower enclosures, install 6 inches above tub top edge.
For
enclosures
with
acrylic
or
other
non-heat
resistant
flooring
Apply with silicone or equal sealant as required for
install Acrylic Shield Part Number 103938.
moisture seal.
3.To prevent door seals from deteriorating do not locate the steam
head where direct steam emission would contact door seals.
Oil Well
4. To reduce noise, do not locate steamhead within 12″ from a wall.
STEP 2 Install steamhead with the oil well facing up as shown. Hand tightening is sufficient when teflon or equal pipe thread sealing compound is used.
STEP 3
STEP 3 Secure a bronze drop ear fitting to a header and run 1/2″ copper steam piping from the steam generator to the drop ear fitting. Install a temporary nipple (6″ or longer) in the drop ear fitting to locate the steamhead after the wall is finished.
STEP 4 After the wall has been finished, mark on the nipple where the surface
of the wall is. Remove the nipple and measure the portion that was in the wall
(the end to your mark). Subtract 1/4″ from that dimension and select a brass
nipple of that length to finish the installation.
STEP 5 Wrap teflon tape around the threads of the new nipple and screw the
nipple into the steamhead. Do not use wrenches or tools which would damage the
steamhead’s finish. Wrap teflon tape around the threads of the nipple and
screw the nipple and steamhead assembly you just made into the drop ear
fitting in the wall. The steamhead should be flush with the wall and the well
must be facing up.
STEP 4
1/8″ minimum clearance required when Acrylic Shield is used. See installation
instructions provided with the Acrylic Shield.
End of pipe to be recessed 1/4″ (without Acrylic Shield) 1/8″ (with Acrylic
Shield)
Drop Ear Fitting
IMPORTANT NOTE: DO NOT disassemble steamhead. MrSteam’s steamhead is shipped
fully assembled and requires no additional assembly. To preserve steam head
finish, DO NOT use wrench or other tools to tighten. DO NOT use abrasive
cleansers or chemicals. Use only water with mild soap and a non-abrasive
sponge.
Because the steam head and direct steam emissions are very hot, locate the
steam head where incidental contact by bather with the steam head or direct
steam emission cannot occur.
Consult with supplier of acrylic, fiberglass and other non-heat resistant
enclosures for recommended steamhead location. Use Acrylic Shield PN 103938
(round) or PN 103938SQ (square). See instructions provided with steam shield.
All drawing are for illustrative purposes only
9
STEP 5
Steamhead Locating Nipple
I N STA L L E R
GENERATOR DIAGRAM
Installation, Operation & Maintenance Manual
Water Inlet Control & Accessory Connections Steam Outlet
Safety Valve
Optional AutoFlush Manual Drain Valve J
IMPORTANT NOTES: Provide a minimum of (12) inches at both ends and top of the
steam generator or as required for servicing. Alternately, provide unions as
required to facilitate installation and disconnection of the steam generator.
The minimum clearance from combustible surfaces is zero all around.
Side View Showing Element Access Panel
61 #81+& ’37+2/’06 &#/#)’ &1 016 %100’%6 219’4 5722.; &+4’%6.; 61 ‘.’/’065
__/5’__’__/5_5_W_R_GT_’’
x
£ÓÇ®
Ç£|{
£n{®
$ n£|n
ÓäÈ®
Ç|n
Óx£®
% £££|{ ÎÓ®
£x£|Ó Î{®
& £{£|{ ÎÓ®
£nÎ|{ {ÇÈ®
‘ £Ç|n
{n®
££|{
ÎÓ®
(Ó
x£®
Ó£|{
xÇ®
) xÇ|n
£{®
È
£xÓ®
*x
£ÓÇ®
{Ç|n
£Ó{®
+ ÈÇ|n
£Çx®
ÇÇ|n
Óää®
,Ó
x£®
Ó
x£®
– £{£|Ó ÎÈn®
£Ç {ÎÓ®
. Ó£|Ó
È{®
Ó£|Ó
È{®
/ ÈÎ|n
£ÈÓ®
ÈÎ|n £ÈÓ®
£° r “«Ì> ÕÌÕà Ӱ ÕÌà Vià ®
7/
,
/
Î|n» */
-/
“1/
/
£|Ó» */
–
/9 66
Î|{» */
1 , 66
£|Ó» */
1/”1- 66
£|Ó» */
All drawing are for illustrative purposes only
10
I N STA L L E R
Installation, Operation & Maintenance Manual
ELECTRICAL
All electrical wiring to be installed by a qualified licensed electrician in
accordance with National Electrical Code and local electrical code.
POWER WIRING See “Field Power Wiring” Diagrams (below) 1. Check power voltage.
Use 240V rated unit when
supply is greater than 208V. (Most homes have 240V, 1PH service). Use 208V
rated unit for 208V power. 2. Use minimum 90° C/300V rated insulated copper
conductors only, sized in accordance with National Electrical Code and local
electrical code for the current in Ampere Chart. If allowed by codes, NM cable
may require a larger wire size than as listed on the chart. 3. Connect
suitably sized equipment grounding wire to ground terminal provided. 4.
Install a separate circuit breaker between supply and unit. Provide a power
supply disconnect within sight of the steam generator or one that is capable
of being locked in the open position. 5. For single phase units, use two-wire
supply source and equipment grounding wire. Neutral (white) wire is not
required.
__ELEC__TR_I_C__AL__CHA__RT____
Vol Max Room
Wire Size Wire Size
Model No. (Cu. Ft.*) KW
Volts Phase Amps (AWG)for 40° C (AWG) for 45° C
_____A_mb_i_e_n_t _____A_mb_ie_nt____
208 1 24 10
8
MS90E 71
5.0
3 14 12
12
240 1 21 10
10
____3__12__12____1__2
208 1
29
8
8
MS150E 107
6.0
3 17 10
10
240 1
25
8
8
____3__14__12____1__2
208 1
36
8
8
MS225E 161
7.5
3 21 10
10
240 1
32
8
8
____3__18__10____1__0
208 1
44
8
6
MS400E 257
9.0
3
25
8
8
240 1
38
8
8
____3__22__10____1__0
208 1
49
6
6
MSSuper 339 10.0
3
28
8
8
1E
240 1
42
8
6
____3__24____8__8____
208 1
58
6
4
MSSuper 411 12.0
3
34
8
8
2E
240 1
50
6
6
____3__29____8__8____
208 1
73
4
3
MSSuper 482 15.0
3
42
8
6
3E
240 1
63
4
4
____3__36____8__8____
*See page 3 for room sizing.
All specifications shown are for 208V and 240V Consult factory for other voltage specifications.
PROVIDE A POWER SUPPLY DISCONNECT WITHIN SIGHT OF THE STEAM GENERATOR OR ONE THAT IS CAPABLE OF BEING LOCKED IN THE OPEN POSITION AS REQUIRED BY CODE.
FIELD POWER WIRING
Contactor
1. TO AVOID EQUIPMENT DAMAGE DO
NOT CONNECT POWER SUPPLY
DIRECTLY TO ELEMENTS!!!
2. L1, L2, Ground to be field wired
3. Super 1E 240/1 models are not supplied
with internal fusing.
4. All Drawings are for illustrative purposes only. Consult with qualified licensed
Power Supply Knock-Out Field
Wiring
Liquid Level Probe
electrician for electrical installation. Models MS90E MS400E
(single phase wiring shown)
Liquid Level Control Board
Transformer
Water Feed Solenoid
Water Feed
AutoFlush Plug and Play Connection
(see page 16)
Steam Outlet
Power Supply Knock-Out
Field Wiring
Power Block Fuses
Liquid Level Control Board
Contactor
Transformer Water Feed Solenoid
All drawing are for illustrative purposes only
Liquid Level Probe
Models MSSUPER1E – 3E
(single phase wiring shown)
11
Water Feed
AutoFlush Plug
and Play Connection (see page 16)
Steam Outlet
I N STA L L E R
Installation, Operation & Maintenance Manual
SSIINNGGLLEEPPHHAASSEE220088/2/24400VVOOLLTTWWIRIRININGGDDIAIAGGRARMAMS S
POWER INPUT
MMOODDEELSLSMMS9S09E0,EM, MS1S5105E0,E, MMSS222255EE,,MMSS440000EE
HEATER
GROUND
S
CONTACTOR
THERMOSTAT
EXPRESS STEAM (optional)
HEATING ELEMENT
TO PROBE
TRANSFORMER CONTROL BOARD
S
WATER FEED SOLENOID VALVE
L E G E N D (All Diagrams)
FIELD WIRING
FACTORY WIRING
AutoFlush (optional)
HomeWizard iGenie (optional) iSteam, AirTempo, iTempo, iTempoPlus Control
MMOODDEELSLSMMSSSUSPUEPRE1RE1,E, MMSSSSUUPPEERR22EE, , MMSSSSUUPPEERR33E E
(N(Nootete: :SSuuppeer1r1EE224400VV ddooeessnnoot thhaavveefufuseses)s)
POWER INPUT FUSES
TRANSFORMER GROUND
WATER FEED SOLENOID VALVE
HEATER
CONTACTOR
THERMOSTAT
EXPRESS STEAM (optional)
HEATING ELEMENT
TO PROBE
CONTROL BOARD
AutoFlush (optional)
HomeWizard iGenie (optional) iSteam, AirTempo, iTempo, iTempoPlus Control
TTHHRREEEEPPHHAASSEE220088/2/24400VVOOLLTTWWIRIRININGGDDIAIAGGRARMAM
MMOODDEELSLSMMS9S09E0,EM, MS1S5105E0,E, MMMMMSSSSS2SSS2U2UU2P55PPEEEEER,,RRM1M12ESEE,S4,,40000EE,, MMSSSSUUPPEERR23EE, MSSUPER3E
POWER INPUT GROUND
TRANSFORMER
WATER FEED SOLENOID VALVE
HEATER
CONTACTOR
THERMOSTAT
EXPRESS STEAM (optional)
HEATING ELEMENT
TO PROBE
12
CONTROL BOARD
AutoFlush (optional)
HomeWizard iGenie (optional) iSteam, AirTempo, iTempo, iTempoPlus Control
All drawing are for illustrative purposes only
I N STA L L E R
Installation, Operation & Maintenance Manual
MULTI-INSTALLATION INSTRUCTIONS
1. Install each unit as in a single installation. Install the two generators
as close to each other as possible.
Shock Hazard. Power must be disconnected at the main electrical supply before removing steam
generator covers.
3. Connect the iSteam®, AirTempo® or iTempo/Plus® control to either generator per the control instructions.
The control must be connected to the primary unit. 4. Insert the ends of
interconnecting cable provided (PN 103904) through the knock-outs as shown in
the
Diagram on page 7. Connect each end to the printed circuit board as shown. 5.
Connect separate plumbing and power supplies for each unit.
WWiririninggDDiiaaggram
PRIMARY UNIT
SECONDARY UNIT
L E G E N D (All Diagrams)
FIELD WIRING
FACTORY WIRING
AutoFlush (optional) iTempo/Start (optional) iSteam, AirTempo or iTempo/Plus
CONTACTOR
{
AutoFlush (optional) Do Not Connect Control
OOPTPIOTNIOANL TAALNDTAEMNDCAEBMLECABLE
FoFr ocorncnoenctninegcmtinogre mthaonre2 tshteaanm2gesnteeraamtorgs
einnteanradteomrs in tandem
PRIMARY UNIT
SECONDARY UNIT
PLUG THIS END TO PRIMARY UNIT Note: The control must be connected to the Primary Unit
AutoFlush (optional)
HomeWizard iGenie (optional)
iSteam, AirTempo, iTempoPlus, iTempo Control
Optional Tandem Cable for 2-5 Generators
Length is 30 ft. PN: 103917
TO FIFTH UNIT
TO FOURTH UNIT
TO THIRD UNIT AutoFlush (optional) Do Not Connect Control
All drawing are for illustrative purposes only
13
I N STA L L E R
Installation, Operation & Maintenance Manual
INITIAL START-UP & CHECKOUT
1. Turn on control. Follow specific instructions provided with controls. 2.
Steam will begin to appear in approximately 5 minutes (unless equipped with
factory-installed Express Steam option) at the
steam head. Steam will shut off when desired temperature is reached and will
automatically resume when room temperature drops below set point. 3. Steam
will shut off automatically when control counts down to zero. To shut steam
off manually, turn control OFF. To clear steam from enclosure area, turn
shower on before opening door. 4. If unit does not start and control does not
turn ON (control display does not light up) then turn breaker off for 20
seconds and try again. 5. Check all internal and external plumbing fittings
for leaks while the steam is on.
OPTIONAL & ACCESSORY EQUIPMENT
Refer to specific instruction manual for installation, operation and
maintenance of optional equipment and accessories such as iSteam®, AirTempo®,
iTempo/Plus®, iTempo®, Home Wizard®, iGenie® and MSTS.
TROUBLESHOOTING
All electrical troubleshooting to be performed by a qualified
licensed electrician
IMPORTANT NOTE: The model and serial number is
printed on the data plate on the front of the steam
bath generator. Step 1 Check main incoming power to the unit.
Contactor
19
7 3
Transformer
Water Feed Solenoid
Step 2 Verify power on secondary side of all
10
fuses.(Model MSSUPER1E-3E only)
Step 3 Ensure the black wires from the primary side of the transformer are
connected to the quick connect tabs on the line side of the contactor.
Step 4 Verify that you have 24VAC coming out of the transformer, WHT & WHT/BLU
wires, into the board.
Step 5 Verify that you have the green light on the PC board.
Step 6 Push the white test button to run the generator for 10 minute test
cycle. Make sure the steam room is empty.
Step 7 Verify that you have 24 VAC to the water feed solenoid, GRAY & WHT/GRAY
wires (will fill when needed).
Step 8 Temporarily short out the WLS (Purple wire) and GND (Green wire)
terminals and verify the contactor engages.
4
Power Supply
8
Knock-Out Field Wiring Liquid
Level Probe Liquid Level
Control Board
5
Models MS90E MS400E
(single phase wiring shown)
Power Supply Knock-Out
Power Block Fuses
10
Field Wiring
1
Water Inlet AutoFlush® Plug and Play Connection
6
Steam Outlet
Contactor
9
Transformer Water Feed Solenoid
7
Step 9 When the red light is on, verify 24 VAC, RED & WHT/RED wires, to the
contactor.
Step 10 Check main voltage on the load side of the contactor when it is
engaged.
Step 11 If all steps on the power path were verified, turn off power to the
unit and pull the heating element via the left hand access panel for
inspection.
DO NOT disassemble internal components, internal components contain no
serviceable parts.
Liquid
Level Probe
2
8
4
Liquid Level
Control Board
3
56
Steam Outlet
Water )NLET
AutoFlush Plug and Play Connection
All drawing are for illustrative purposes only
14
I N STA L L E R
Installation, Operation & Maintenance Manual
SYSTEM STATUSCODES
TThhee ccoonntrtorol (liT(ieTmepmop/Polu/Ps®lu)
ms®a)ymdaisypldayisaplsataytuassctoadtuesifctohedesteifamthegesnteeraatmorgisennoetrfautnocrtioisninnogtpfruonpcetrilyo.ning
properly.
Code H20
H20y
Code Meaning
Water level is not
Watersleavteislfisendotwithin 6 satisfiemdiwni.thin 6
min.
oPPorrrrrPr1P1rrr2r2 TempeTreamturpeePrraotbuereErProror be Error
Probable Cause
Suggested Remedy
WPraotbearbSluepCpaluysies off
SugTguernsteodn RWeamteerdSyupply
Water Supply is off
Turn on Water Supply
DDeeffeeccttiviveewwatearteferefdeseodlesnooildenWoaitderWater CheCchk/erecpkl/arceepwlaacteer wsoaletneoridsovlaelvneoid valve
ffeeedd pprroobbeenontofutnfcutniocntiinogning Drain Valve Open AutoFlush not DffuurnnaccitntioioVnnianilgnvge Open AutoFlush not
CheCchk/eccleka/nclperaobnep. robe. CheCchkepcrokbperwoibrinegw. iring. CheCchk/eCcloks/eCdlorasien vdarlavein valve CheCchk/eRcekp/laRceepAlautcoeFlAusuhtoFlush
Control cable/MSTS cable cut
Replace control cable / MSTS
CIInnotteenrrtnnraoalllpcproarobblbleeml/eMmwSitwhTSictohcnactrboolnle/MtrcoSuTl/tSMSTS R epRRlaeecppellcaaoccneetroccloo/nnMttrrSooTllS/cMaSbTleS/MSTS
EErrr1r1
I(bgnocreaoerrdnreIVlwenlciogivctlllhFeotbtailreeorgclednoeocSfnltti(uq)gtFpruroipieedlleylbdlenVovoSleailugltracdphgoptenwltoyriolnll
liquid be oft)
IttInonoccGGoorererrneneecectratrvtaovotlortoalrtgaegseupspulipepd lied
Err2 Button on control is pressed for
Control cover misalignment
Err2 more tBhauntt5onmionuntecsontrol is pressed CDoebnrtirsoblechoinvdecromntrioslacloigvenrment for more than 5 minutes
Debris behind control cover
Err7 Liquid Level Control Board malfunction Memory error in LLCB
Err7
Liquid Level Control Board Memory error in LLCB
malfunction
SvuopltScpaouglyrpersepnteoclayttemsdtgeoenanmethraetgoderatnwaeitphrlaatttheoelracobwrerilet.hct
the voltage noted on the data plate label.
Remove and reinstall control cover
RemRoevme coovnetroalncdovreer iannsdtacllelacnocnotvreor,l cover control and
keypad with a damp cloth
Remove control cover and clean cover, Precsos nOtNro/Ol aFnFdtokeclyepara.
dRewpliathcea damp cloth conPtrreolssif OcoNde/OreFmFaitnos.clear. Replace
control if code remains.
LIQUID LEVEL CONTROL BOARD Explanation of LED Indicators
GREEN
LED is ON when there is 208/240 Volt incoming power connected, 24 Volt transformer secondary output and on-board 5 Volt DC control power are present.
YELLOW
Water level indicator-LED is OFF when no water is detected (for more that 5 seconds). ON when water level is satisfactory. For units with AutoFlush, if more than five hours have elapsed since last usage and this LED is ON it is indicative of an AutoFlush or water level probe circuit malfunction.
RED
Contactor relay indicator-L ED is ON when relay is closed and sending 24 Volts to the contactor coil. (This LED comes ON if the generator is ON.)
FORCE ON BUTTON
Press this button to operate the generator. This button is for trouble shooting only and will operate TEST if a control is connected or not. Pressing the button again will shut the generator OFF. The test button will only allow the generator to operate for 10 minutes.
Liquid Level Control Board PN 104288 (shown without wiring)
All drawing are for illustrative purposes only
Green (Power)
Yellow (Water Level)
15
Red (Heater) Force On Test Button
I N STA L L E R
Installation, Operation & Maintenance Manual
OPTIONAL AUTOFLUSH®
Box Contents AutoFlush Valve with Cord Installation Instructions
OPERATION The optional AutoFlush System feature automatically drains the
MrSteam generator following each use. A time delay allows the water to cool
down (about two hours) before it drains by gravity for a safe and gentle
operation.
If the Express Steam® option has been installed, the AutoFlush will drain for
ten minutes then refill with fresh water to begin the pre-heat cycle.
INSTALLATION INSTRUCTIONS
1. Plumbing to be performed by a qualified plumber and shall be in accordance
with applicable national and local codes. Unit drains by gravity. A drain line
that is lower than the AutoFlush® assembly must be available. The AutoFlush
System valve outlet is 1/2″ NPT. Check plumbing code for receptor, trap and
vent requirements.
2. Use copper or brass nipple 1/2″ NPT x 31/2″ or longer (not supplied) to
connect AutoFlush valve to the Drain Valve (follow arrow on AutoFlush valve
for flow direction, arrow should point away from generator’s drain valve).
DO NOT REMOVE THE DRAIN VALVE Removal may cause equipment and property damage.
If there is not enough room for the valve, an elbow and a short nipple (not
provided) can be added.
3. Open Drain Valve (handle must be aligned with brass nipple).
4. Connect the AutoFlush System cord connector to the three pin connector as
shown.
5. The AutoFlush valve must be installed within the orientation range shown.
DO NOT drain into a steam enclosure or any location where accidental contact
with drain water may occur. In the event of a power failure the AutoFlush
System valve will open and may discharge boiling water causing a scalding
hazard.
SWEAT FITTINGS When using sweat fittings use only tin base solder with a
melting
point below 600 degrees F. DO NOT overheat. Ends of water supply tubing must
be thoroughly clean for a minimum distance of 1″ from ends. DO NOT remove
valve cover.
TO CHECK OPERATION 1. Turn on MrSteam and allow tank to fill with water. 2.
Turn off MrSteam control. Water should stay in tank. 3. Turn off power at the
panel box. Water should discharge from
tank. 4. Turn on power at panel box. 5. Repeat
PROVIDE DRAIN PLUMBING ACCORDING TO LOCAL CODES. PLUMB AS REQUIRED FOR
AUTOFLUSH SYSTEM.
16
Steam Generator
3 Pin Connector for AutoFlush
AutoFlush Cord Connector
AutoFlush Cord
Nipple copper or brass nipple 1/2″ NPT x 31/2″ or longer (not supplied)
AutoFlush Valve
Drain Valve (shown in the correct open position)
DO NOT REMOVE THIS DRAIN VALVE
Plumb to Drain Line Arrow indicates correct direction of flow
AutoFlush Valve
Steam Generator
Drain Valve DO NOT TURN OR REMOVE
THE DRAIN VALVE (shown in the correct open
position)
Nipple
AutoFlush Shown Fully Assembled
Plumb to Drain Line
All drawing are for illustrative purposes only
I N STA L L E R
Installation, Operation & Maintenance Manual
OPTIONAL CONDENSATION PAN
MrSteam strongly recommends the use of a condensation pan in the unlikely
event of a plumbing leak. Locate the condensation pan on a solid level surface
and place the steam generator inside the condensation pan. Insure the steam
generator is level (see page 5 for locating the steam generator). All plumbing
shall be performed by a qualified licensed plumber and in accordance with
applicable national and local codes. Check local plumbing code for receptor,
trap and vent requirements. Condensation pans drain by gravity. The
condensation pan is equipped with an integral female 3/4″ NPT fitting.
Do not plumb the generator drain and condensation pan drain together in such a
way that will cause drain water to back into condensation pan.
OPTIONAL EXPRESS STEAM®
(only available factory installed) Available for all MS Models. Express Steam
generators are equipped with a low power heating element and thermostat to
keep the water in the tank warm enough to bring up steam quicker. All Express
Steam components and wiring are installed at the factory. No additional wiring
or plumbing is required by installers.
All drawing are for illustrative purposes only
17
I N STA L L E R
Installation, Operation & Maintenance Manual
PARTS IDENTIFICATION DIAGRAMS
MS REGULAR MODELS: MS90E – MS400E
(with AutoFlush®)
shown with cover removed
Liquid Level Probe
Power Supply Knock-Out
Access Cover
Contactor
Liquid Level Control Board
Transformer
Water Feed Solenoid
Water Inlet
Plug and Play Connection (see pg. 16)
Steam Outlet
FOR ILLUSTRATIVE PURPOSES
ONLY.
Some components may be omitted
or altered for clarity. DO NOT use for
wiring, repair or other purposes not
related to component identification.
Express Steam Heater (optional)
Heating Element Stainless Steel Tank
Safety Valve
Nipple Manual (not included) Drain Valve
AutoFlush Valve (optional)
Drain Line
MS SUPER MODELS: MSSUPE1E – MSSUPER3E
(with AutoFlush®) shown with cover removed
Super1E 240/1 models are not supplied with internal fusing.
Liquid Level Probe
Power Supply Knock-Out
Power Block
Fuses
Liquid Level Control Board
Contactor
Transformer
Water Feed Solenoid
Water Inlet
Element Access Cover
FOR ILLUSTRATIVE PURPOSES
ONLY. Some components may be omitted or altered for clarity. DO NOT use for
wiring, repair or other purposes not related to component identification.
Express Steam
heater (optional) Heating Element
Stainless Steel Tank
Plug and Play Connection (see pg. 16)
Safety Valve
Steam Outlet
Nipple Manual (not included) Drain Valve
AutoFlush
Valve (optional)
All drawing are for illustrative purposes only
18
I N STA L L E R
Installation, Operation & Maintenance Manual
REPLACEMENT PARTS LIST
Part No.
99178MS 99297 100479 10477-3 104288 103904 103917 103990-60 104117-30
104117-60 MSTS MSTS-60 100476-2 99012 103453 100471-2 99096MS 103938RD
103938SQ 99314 29051BMS 29051CMS 29061BMS 29061CMS 29071BMS 29071CMS 29091BMS
29091CMS 29101BMS 29101CMS 29121BMS 29121CMS 29151BMS 29151CMS
Description
Drain Valve Safety Valve 15PSI Water Feed Solenoid Valve w/filter Transformer
24VAC Liquid Level Control Board Tandem Cable for 2 generators (12 ft.) Tandem
Cable for up to 5 generators (30 ft.) Cable for iTempo® Control (60 ft.) Cable
for iSteam®, AirTempo® & iTempo/Plus® (30 ft.) Cable for iSteam (60 ft) Remote
Temperature Probe (integral 30ft cable) Remote Temperature Probe (integral
60ft cable) Contactor 50A 2-pole Contactor 50A 3-pole Contactor 50A 4-pole
Probe Assembly Heating Element Gasket Acrylic Shield for Round Steamhead
Acrylic Shield for Square Steamhead Power Fuse 60A 250V Heating Element 5 KW
208V Single Phase Heating Element 5 KW 240V Single Phase Heating Element 6 KW
208V Single Phase Heating Element 6 KW 240V Single Phase Heating Element 7.5
KW 208V Single Phase Heating Element 7.5 KW 240V Single Phase Heating Element
9 KW 208V Single Phase Heating Element 9 KW 240V Single Phase Heating Element
10 KW 208V Single Phase Heating Element 10 KW 240V Single Phase Heating
Element 12 KW 208V Single Phase Heating Element 12 KW 240V Single Phase
Heating Element 15 KW 208V Single Phase Heating Element 15 KW 240V Single
Phase
Generator
All Models All Models All Models All Models All Models All Models All Models
All Models All Models All Models All Models All Models MS90E-400E, Single
phase All 3-Phase Models MSSuper1E3E All Models All Models All Models All
Models MSSuper2E3E MS90E MS90E MS150E MS150E MS225E MS225E MS400E MS400E
MSSUPER1E MSSUPER1E MSSUPER2E MSSUPER2E MSSUPER3E MSSUPER3E
For other voltages and phases contact MrSteam
19
I N STA L L E R
Installation, Operation & Maintenance Manual
CONTROL INSTALLATION
Refer to Control Manual for specific installation requirements
BEFORE INSTALLING
Turn power to the steam generator OFF before connecting the control to the
generator. Failure to turn the power off will result in an inoperable control.
To avoid unintentional steambath operation, DO NOT locate the control where
other controls, accessories, shower heads, valves, body sprays or similar
within the shower could cause confusion or interfere with the MrSteam
control’s intended use and function.
Probe. Failure to install according to instructions will result in an
inoperative control and overheating of the steam room.
DO NOT route iSteam, AirTempo, iTempo/Plus, iTempo, HomeWizard or iGenie
control wiring inside conduit together with power lines or close to hot water
or steam piping. Doing so may result in an inoperative or hazardous
installation.
DO NOT alter or modify any MrSteam product. Doing so may result in an
inoperative or hazardous installation and will void the UL listing and
warranty.
DO NOT use any iSteam®, AirTempo®, iTempo/Plus®, iTempo®, HomeWizard® or
iGenie® controls without reading and understanding its own manual and the
MrSteam steam generator Installation and Operation Manual. Failure to read and
understand these instructions may result in an inoperative or hazardous
installation.
A peel and stick warning sticker must be read and permanently affixed in a
conspicuous location near the steam room. Failure to read and affix this
warning sticker in a conspicuous location may result in serious injury or
death. .
Install the iSteam, AirTempo, iTempo or iTempo/Plus controls according to
installation instructions. Failure to install according to instructions will
result in an inoperative control or hazardous overheating or inadequate
heating of the steam room.
If an iSteam, AirTempo, iTempo or iTempo/Plus control is installed outside the
steam room a Remote Temperature Probe (PN MSTS) must be installed inside the
steam room per installation instructions supplied with the Remote Temperature
IMPORTANT NOTES: 1. Turn power to the steam generator OFF before connecting
the control to the generator. Failure to turn the power off will result in an
inoperable control. 2. DO NOT operate iSteam, AirTempo, iTempo/Plus, iTempo,
HomeWizard or iGenie controls with other than a MrSteam iSteam, AirTempo, or
iTempo compatible steam generator. MrSteam residential steam generators with
serial numbers lower than 900000, or any other brand of steam generator are
not to be operated with iTempo controls. Doing so may result in an inoperative
or hazardous installation. If iSteam is used with a generator having serial
number less than 1174000, contact MrSteam technical support for an upgraded PC
board. 3. This document contains important safety, operation and maintenance
information. Leave this document with the homeowner. DO NOT discard this
document. 4. Discontinue use of the steam generator or control if the steam
generator is damaged or otherwise not functioning properly. Operating a
damaged steam generator may result in an inoperative or hazardous installation
CONTROL ROUGH IN
Refer to Installation Instructions for the specific control
IMPORTANT NOTE: The control cable should be run in a dedicated 1″ conduit to
facilitate installation and service.
1. Determine the desired installation location of the control. The iSteam®,
AirTempo®, iTempo® and iTempo/Plus® controls are designed to be installed
inside or outside the steam room as a matter of personal preference. If the
control is installed inside the steam room the control must be located:
2. 4 – 5 feet above the floor near the bather seating area
3. The control features an integral temperature sensor. Locate the control in
a location representative of the desired steam bathing temperatures. DO NOT
locate the control above or near the steam head or direct steam emissions.
4. On a vertical wall The iSteam and iTempo control cable length is 30 feet.
Insure that the control and/or steam generator are located accordingly. An
optional 60 foot cable is available, PN103990-60 for AirTempo and iTempo and
PN 104117-60
20
for iSteam. Contact a MrSteam technical service representative if a 60 foot
cable is required. Excess control cable should be neatly coiled and twisted
into a figure 8. The AirTempo dongle is provided with a 3 foot cable. The
maximum cable length is 60 feet.
IMPORTANT NOTES: · If the control is installed outside the steam room a Remote
Temperature Probe Part Number MSTS must be installed inside the steam room,
depending on the control. · Insure MrSteam steam generator is iSteam, AirTempo
or iTempo compatible and has a serial number 900000 or higher. If iSteam is
used with a generator having serial number less than 1174000, contact MrSteam
technical support for an upgraded PC board. · See instructions for the MSTS
Temperature Probe (located in the Control Installation Manual related to your
specific control package) before rough-in or installation of control.
®
mr.steam®
Installation, Operation & Maintenance Manual
mr.steam
HOMEOWNER SECTION
READ ME FIRST!
As you follow these instructions, you will notice warning and caution symbols.
This blocked information is important for the safe and efficient installation
and operation of this generator. These are types of potential hazards that may
occur during installation & operation:
Indicates a potentially hazardous situation, which, if not avoided, could
result in death or serious injury.
Indicates a potentially hazardous situation, which, if not avoided may result
in minor or moderate injury or product damage.
is used to address practices not related to physical injury.
IMPORTANTNOTE: This highlights information that is especially relevant to a
problem-free installation.
All information in these instructions is based on the latest product
information available at the time of publication. MrSteam reserves the right
to make changes at any time without notice. More current instructions may be
available at www.mrsteam.com.
When installing and using this electrical equipment, basic safety precautions
should always be followed, including the following:
IMPORTANT SAFETY INSTRUCTIONS
1. READ AND FOLLOW ALL INSTRUCTIONS
2. all times.
Supervise children at
Steam is hot and can
cause injury or death if improperly
used. Steam rooms contain steam and
elevated temperatures. Please read
and observe all warnings in this
manual before installing or using a
steam room.
To reduce the risk of
injury:
A. The wet surfaces of steam
enclosures may be slippery. Use care
when entering or leaving.
B. The steam head is hot. DO NOT
touch the steam head and avoid the
steam near the steam head.
C. Prolonged use of the steam system
can raise excessively the internal
human body temperature and impair
the body’s ability to regulate its
internal temperature (hyperthermia).
Limit your use of steam to 10-15 minutes until you are certain of your body’s
reaction. D. Excessive temperatures have a high potential for causing fetal
damage during the early months of pregnancy. Pregnancy or possibly pregnant
women should consult a physician regarding correct exposure. E. Obese persons
and persons with a history of heart disease, low or high blood pressure,
circulatory system problems, or diabetes should consult a physician before
using a steambath. F. Persons using medication should consult a physician
before using a steambath since some medication may induce drowsiness while
other medications may affect heart rate, blood pressure and circulation.
SAVE THESE
INSTRUCTIONS
HYPERTHERMIA occurs when the internal temperature of the body reaches a level
several degrees above the normal body temperature of 98.6° F. The symptoms of
hyperthermia include an increase in the internal temperature of the body,
dizziness, lethargy, drowsiness, and faint-ing. The effects of hyperthermia
include: a) Failure to perceive heat; b) Failure to recognize the need to exit
the steambath; c) Unawareness of impending risk; d) Fetal damage in pregnant
women; e) Physical inability to exit the steambath and f) Unconsciousness.
The use of alcohol, drugs, or medication can greatly increase the risk of
hyperthermia.
The peel and stick warning label located in this manual is an essential part
of providing a safe environment for steam room users. The peel and stick
warning label must be applied to the wall of the shower or steam enclosure, at
a point that is visible to all users. Failure to install this sticker may
result in serious injury or death.
The location where this owner’s manual is kept shall be written in the space
provided on the label using permanent ink.
For a replacement warning label contact MrSteam customer service at
1-800-76-STEAM or hello@mrsteam.com
Not actual size
! WARNING
REDUCE THE RISK OF OVERHEATING AND SCALDING
1. EXIT IMMEDIATELY IF UNCOMFORTABLE, DIZZY OR SLEEPY. STAYING TOO LONG IN A
HEATED AREA IS CAPABLE OF CAUSING OVERHEATING.
2. SUPERVISE CHILDREN AT ALL TIMES. 3. CHECK WITH A DOCTOR BEFORE USE IF
PREGNANT, DIABETIC, IN POOR HEALTH OR UNDER
MEDICAL CARE. 4. BREATHING HEATED AIR IN CONJUNCTION WITH CONSUMPTION OF
ALCOHOL, DRUGS, OR
MEDICATION IS CAPABLE OF CAUSING UNCONSCIOUSNESS. 5. DO NOT CONTACT STEAM HEAD
OR STEAM AT THE STEAM HEAD.
REDUCE THE RISK OF SLIPPING AND FALL INJURY
1. USE CARE WHEN ENTERING OR EXITING THE STEAM ROOM. FLOOR MAY BE SLIPPERY
NOTE: FOR ADDITIONAL SAFETY CONSIDERATIONS SEE OWNER’S MANUAL WHICH IS
KEPT:___ THE OWNER’S MANUAL CAN BE FOUND
AT WWW.MRSTEAM.COM USE OF STEAM ROOM IN CONJUNCTION WITH CONSUMPTION OF
ALCOHOL CAN BE DANGEROUS AND CAN RESULT IN INJURY THROUGH SLIP AND FALL OR
OTHERWISE.
43-20 34th Street , Long Island City, NY 11101 · 1 800 76 STEAM ·
www.mrsteam.com
PUR100378 5.22
21
H O M E OW N E R
Installation, Operation & Maintenance Manual
SETTING THE STEAM BATH TEMPERATURE AND DURATION
Set the steam bathing temperature according to personal preference, however it
is highly recommended to begin steam bathing at a low temperature setting to
gauge comfort and safety levels. Set duration to a maximum of 10 minutes to
gauge comfort and safety levels. This will allow the steam generator to heat
up and begin producing steam.
SAFETY AND OPERATING INFORMATION
DO NOT install or use any iSteam®, AirTempo®, iTempo/Plus®, iTempo®,
HomeWizard® or iGenie® controls without reading and understanding the MrSteam
steam generator Installation and Operation Manual. Failure to read and
understand these instructions may result in an inoperative or hazardous
installation.
The peel and stick warning sticker located in this manual must be read and
permanently affixed in a conspicuous location near the steam room. Failure to
read and affix this warning sticker in a conspicuous location may result in
serious injury or death.
If an iSteam, AirTempo, iTempo or iTempo/Plus control is installed outside the
steam room a Remote Temperature Probe (PN MSTS) must be installed inside the
steam room per-installation instructions supplied with the Remote Temperature
Probe. Failure to install according to instructions will result in an
inoperative control and overheating of the steam room.
To prevent slip and fall hazards nonskip strips must be installed on the steam
room floor. DO NOT alter or modify any MrSteam product. Doing so may result in
an inoperative or hazardous installation and will void the UL listing and
warranty.
IMPORTANT NOTES: Malfunction due to power spikes, lightning, fire, freezing or
flooding is not covered under the warranty.
Discontinue use of the steam generator or control if the steam generator is
damaged or otherwise not functioning properly. Doing so may result in an
inoperative or hazardous condition.
CARE TIPS FOR ALL CONTROLS AND STEAMHEADS
1. Use only mild soap and water on a soft cloth to clean the control and
steamhead. 2. DO NOT use abrasive cleansers. 3. If the decorative cover is
damaged on the iTempo or iTempo/Plus call MrSteam technical service for
replacement parts.
Replacement of the decorative covers requires removal and reinstallation of
the control from the mounting surfaces.
STEAM GENERATOR MAINTENANCE
MrSteam steambath generators require little maintenance. Other than periodic
draining, maintenance procedures are minimal. Every 2 months, or more often in
“hard” water areas, the manual drain valve should be opened fully flushing out
accumulated materials, salts and other particles which are natural byproducts
of boiling water.
Flush a minimum of two-three hours after the control has been turned off to
insure that the water has cooled.
Draining immediately after a steam cycle may expose PVC and other piping to
high temperature water. Check local codes. The unit will refill automatically
when the control is activated again. In areas of hard water, a MrSteam
AutoFlush® system is recommended for generator longevity.
Failure to allow the water to cool will expose the equipment and user to
scalding water and cause property and personal injury.
IMPORTANT NOTE: The model and serial number is printed on the data plate on
the front of the steam bath generator.
22
H O M E OW N E R
Installation, Operation & Maintenance Manual
USING MrSteam ESSENTIAL OILS
Enjoy AromaSteam essential oils by placing a drop or two into an unheated
AromaSteam steamhead as shown in the illustration. Only use MrSteam AromaSteam
essential oils in the MrSteam AromaSteam steamhead.
Essential oils and/or aroma therapy can cause inflammation, burns, headache,
nausea and allergic reactions. Consult a physician before using aromatherapy.
(Items 1-4) 1. Use essential oils with caution. Essential oils are for
external use only. Keep out of reach of children. Essential oils are highly
concentrated and are potent substances and should not be applied directly to
the skin as they can be irritants. Use essential oils with caution. 2. Place
the drops into the MrSteam AromaSteam steamhead recess prior to turning on the
steambath. DO NOT place drops in a hot steam head as serous injury can result
if you do not follow this warning. 3. Start with one drop to gauge strength
and suitability. Limit to a maximum of a few drops for a steam bathing
session. 4. The bather should exit the steambath IMMEDIATELY if dizziness
occurs. If skin irritation occurs stop using the oils immediately. Remove any
excess oil by washing in mild soap and water. If ingested, rinse mouth with
water. Administer water or milk to dilute. Contact a physician immediately.
Aromatic oils should be added to steamhead before turning on the steambath
unit. DO NOT add oil during steam bathing or when the steam head is heated.
Tightly close bottles when storing oils. Keep bottles away from sources of
ignition.
AromaSteam 10ml bottle with integrated dropper Recess for essential oil
Steam emission slot
AromaSteam steamhead (install per instructions on pg.9)
WARRANTY
To view or download the MrSteam Residential Generator Warranty
and register your Product go to: blog.mrsteam.com/wr
All drawing are for illustrative purposes only
23
NOTES
24
NOTES
25
mr.steam®
Feel Good Inc.®
www.mrsteam.com
Products, information and specifications are sub ect to change without notice.
Please call Sales & Support at 1.800.76.STEAM (East Coast) or 1.800.72.STEAM
(West Coast) for more information.
mr.steam® hello@mrsteam.com I www.mrsteam.com
43-20 34th Street, Long Island City, NY 11101 1 800 76 STEAM I 9410 S. La
Cienega Blvd. Inglewood CA 90301 1 800 72 STEAM
2020 © MrSteam and des., A Lifetime of Pleasure, AirTempo, AromaFlo,
AudioWizard, AutoFlush, AutoSteam, Butler Package, ChromaSteam, Clean
Steam…Every Time, Club Therapy, CT Day Spa, Digital 1, Express Steam, Feel
Good Inc., From Bathroom to Spa, HomeWizard, iButler, iGenie, iSpa Package,
iSteam, iTempo, iTempo/Plus, Linear Steamhead, Making Wellness a Way of Life,
Music Therapy, My Steam, SmartSizing, Spa Package, Steam Genie, Steam on
Demand, Steam in a Box, Steam@Home, SteamStart, SteamTherapy, Tala, Tala Bath
& Body, Tempo, The Intelligent Steambath, Valet Package, and Virtual Spa
System are registered trademarks of MR.STEAM.
PUR 100472A REV 6.24
References
- Home | Steam Shower Generators Controls Accessories | MrSteam
- Home | Steam Shower Generators Controls Accessories | MrSteam
- Tile Council of North America | Voice of the Ceramic Tile Industry