Goodman CHPTA1822B3 Horizontal Cased Evaporator Coil Installation Guide

September 20, 2024
Goodman

Goodman CHPTA1822B3 Horizontal Cased Evaporator Coil

Product Information

Specifications

  • Model : IO-4013C
  • Refrigerant : R32
  • Static Pressure : 0.66 WC
  • Manufacturer : DAIKIN COMFORT TECHNOLOGIES MANUFACTURING, L.P.
  • Contact : 855-770-5678
  • Location : 19001 KERMIER ROAD WALLER, TEXAS 77484

Product Usage Instructions

Safety Instructions
It is important to follow safety instructions to prevent personal injury, property damage, and product damage:

  • Disconnect all power sources before servicing or installing the unit.
  • Only trained personnel should service the equipment.
  • Do not allow children or individuals with reduced capacities to use the appliance without supervision.
  • Ensure the unit is not accessible to the general public.
  • Do not bypass safety devices.

Shipping Inspection
Upon receiving the product, follow these steps:

  • Inspect for damage from shipment.
  • Verify model number, specifications, and accessories are correct.
  • Contact the carrier for shipping damage claims.

Handling
Handle the unit with care during transportation:

  • Avoid carrying with hooks or sharp objects.
  • Use a two-wheel hand truck or carry by hand from the back or sides.
  • Avoid damage to piping during transportation.

Pre-Installation Instructions
Before installation, consider the following:

  • Install the appliance according to national wiring regulations.
  • Ensure a minimum clearance of 24 inches for service access.
  • Refrigerant lines must be routed based on unit configuration.
  • The product is not suitable for outdoor use.

R32 Sensor Connection
Follow one of the 3 scenarios provided in the manual to determine where the R32 sensor needs to be connected.

Important Safety Instructions

The following symbols and labels are used throughout this manual to indicate immediate or potential safety hazards. It is the owner’s and installer’s responsibility to read and comply with all safety information and instructions accompanying these symbols. Failure to heed safety information increases the risk of personal injury, property damage, and/or product damage.

WARNING

HIGH VOLTAGE

  • Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death.
  • Only personnel that have been trained to install, adjust, service, maintain, or repair (hereinafter, “service”) the equipment specified in this manual should service the equipment.
  • This equipment is not intended for use by persons (including children) with reduced physical, sensory, or mental capacities, or lack of experience and knowledge unless they have been given supervision or instruction concerning the use of the appliance by a person responsible for their safety.
  • Children should be supervised to ensure that they do not play with the equipment.
  • The manufacturer will not be responsible for any injury or property damage arising from improper supervision, service, or service procedures. If you service this unit, you assume responsibility for any injury or property damage that may result. In addition, in jurisdictions that require one or more licenses to service the equipment specified in this manual, only licensed personnel should service the equipment. Improper supervision, installation, adjustment, servicing, maintenance, or repair of the equipment specified in this manual, or attempting to install, adjust, service, or repair the equipment specified in this manual without proper supervision or training may result in product damage, property damage, personal inu ry ,or death.
  • Do not bypass safety devices.
  • If any hot work is to be conducted on the refrigerating equipment or associated parts, appropriate fire extinguishing equipment shall be available on hand. Have a dry powder or CO2 fire extinguisher adjacent to the hot work area.
  • Ensure that the area is in the open or that it is adequately ventilated before breaking into the system or conducting any hot work. A degree of ventilation shall continue during the period that the work is carried out. The ventilation should safely disperse any released refrigerant and preferably expel it externally into the atmosphere.

NOTE : This unit should be installed in a manner so that it is not accessible to the general public.

Shipping Inspection
This equipment is approved for use with R32 Refrigerant only. Upon receiving the product, inspect it for damage from shipment. Shipping damage and subsequent investigation are the responsibility of the carrier. Verify the model number, specifications, and accessories are correct before installation. The distributor or manufacturer will not accept claims from dealers for transportation damage or installation of incorrectly shipped units.

Handling
Use caution when transporting/carrying the unit. Do not carry a unit with hooks or sharp objects. The preferred method of carrying the unit after arrival at the job site is to carry it by two-wheel hand truck from the back or sides or by hand by carrying it at the cabinet corners. Take proper precautions when carrying the unit to avoid any damage to the piping.

Codes & Regulations
This product is designed and manufactured to comply with national codes such as ASHRAE 15, ASHRAE 15.2, IAPMO Uniform Mechanical Code, ICC, International Mechanical Code, or CSA B52. The product shall be installed in accordance with national wiring regulations. Installation in accordance with such codes and/or prevailing local codes/regulations is the responsibility of the installer. The manufacturer assumes no responsibility for equipment installed in violation of any codes or regulations. The United States Environmental Protection Agency (EPA) has issued various regulations regarding the introduction and disposal of refrigerants. Failure to follow these regulations may harm the environment and can lead to the imposition of substantial fines. Should you have any questions please contact the local office of the EPA.

Replacement Parts
Inspect the unit to verify all required components are present and intact. Report any missing components immediately to the manufacturer or the distributor. Make sure to include the full product model number and serial number when reporting and/or obtaining service parts. Replacement parts for this product are available through your contractor or local distributor. For the location of your nearest distributor consult the white business pages, the yellow page section of the local telephone book or contact: HOMEOWNER SUPPORT DAIKIN COMFORT TECHNOLOGIES MANUFACTURING, L.P. 19001 KERMIER ROAD WALLER, TEXAS 77484 855-770-5678

Pre-Installation Instructions

  • The appliance shall be installed according to national wiring regulations. This product was tested at an external static pressure of 0.66 WC. None of the components in this product line are designed or approved to be suitable for outdoor use.
  • Refrigerant lines must be routed depending on the configuration of the unit to maintain the required 24” minimum clearance for service.
  • This appliance is equipped with a leak detection sensor which must be wired through the connector on the furnace PCB or Non-A2L Furnace Integration Kit.
  • The R32 Sensor must be installed and powered for service. Ensure that the grommet is installed through the access panel knockout hole. Sensor bracket assemblies are shipped with two zip ties, one of which is designed for strain relief. The zip tie shown in  Figure 1, detail A must be kept attached to the sensor bracket assy. Detail B highlights the zip tie that must be cut during installation to release the wire bundle.

Follow one of the 3 scenarios below to determine where the R32 sensor needs to be connected:

  • Scenario 1: Amana® Brand / Goodman / Daikin Furnace PCB with R32 sensor compatibility.
    The leak detection sensor must be wired directly to the furnace. Follow the routing diagram as shown in Figures 4 or 5 depending on the orientation of the installation. This wiring is intended to be passed through the access hole on the furnace. If a hole must be cut into the furnace, ensure that the wiring is well protected from mechanical damage and that the hole is free from burrs or sharp edges. Utilize a protective coating for all exposed metallic edges to prevent corrosion. Verify that the A2L function (this is required for R32 integration) is enabled on the furnace board PCB. Refer to the furnace IO for further instructions on how to toggle this function from disabled to enabled. The A2L verification step as described on the furnace IO must be completed before the unit is commissioned. If the test is not successful, call 1-855-DAIKIN1, option 3, for further assistance.

  • Scenario 2: Amana® Brand / Goodman / Daikin Furnace or Modular Blower PCB with no R32 sensor compatibility.
    The leak detection sensor must be wired directly to the Non-A2L Furnace Integration Kit control board and installed as a pass-through to the non-A2L furnace control board. For instructions on how to correctly wire the Non-A2L Furnace Integration Kit refer to the kit IO.

  • Scenario 3: All other OEMs.
    The availability of mitigation mode, or equivalent, must be checked through the furnace model manufacturer IO. Please follow relevant instructions to disable mitigation mode or equivalent. Once this step is complete follow the instructions of scenario 2. If mitigation mode, or equivalent, is present but can’t be disabled the furnace must be replaced. If mitigation mode, or equivalent, is not available follow the instructions on scenario 2.
    Under no circumstance should the system be charged with refrigerant at a capacity greater than the refrigerant charge listed on the serial plate. This value indicates refrigerant charge at or above 30% GREATER than the intended charge with the longest line sets. If an additional charge is required, you must contact Daikin Comfort’s Homeowner Support Line.

Preparation

Keep this document with the unit. Carefully read all instructions for the installation before installing the product. Make sure each step or procedure is understood and any special considerations are taken into account before starting installation. Assemble all tools, hardware, and supplies needed to complete the installation. Some items may need to be purchased locally. Make sure everything needed to install the product is on hand before starting.

Clearances
Consult all appropriate regulatory codes before determining final clearances. In installations that may lead to physical damage (i.e. a garage), it is advised to install a protective barrier to prevent such damage. Always install units such that a positive slope in the condensate line (1/4” per foot) is allowed. Further, any joints made in the installation between parts of the refrigerating system must be accessible for maintenance purposes.

WARNING

  • Auxiliary devices which may be a potential ignition source are not to be installed in the ductwork. Such potential ignition sources include hot surfaces with a temperature exceeding 650C and electric switching devices. For example, electronic air filters are a potential ignition source.
  • Only auxiliary devices approved by the appliance manufacturer or declared suitable with the refrigerant shall be installed in connecting ductwork. If an existing device is not approved by the appliance manufacturer for use with the refrigerant, the device must be removed or disconnected.

System Matches
The entire system (combination of indoor and outdoor sections) must be manufacturer-approved and the Air Conditioning, Heating, and Refrigeration Institute (AHRI) listed.

NOTE : Installation of unmatched systems is not permitted.

Application Information
Install this coil upstream (discharge air) of the furnace and install it downstream (return air) of the modular blower. This coil is a bi-directional coil and can be installed in either the left or right direction. Determine the coil direction by the side that allows the best access.

NOTE : These Coils are designed for Indoor installation only.
If the unit is located in an unconditioned area with high ambient temperature and/or high humidity, the coil may be subject to nuisance sweating of the casing. On these installations, a wrap of 2” fiberglass insulations with a vapor barrier is recommended.

Furnace to Coil Attachment

Refer to the Furnace IO manual for further instructions.
There is no conversion required to reverse from right to left application. Attach the duct flanges to the discharge side of the unit. If the coil and furnace combination are not similar in depth and width, use a field-supplied transition to center the furnace and coil openings (see Figure 6).

  1. Using the hardware and brackets provided, attach the coil to the furnace then attach the plenum to the coil (Figure 6). Using tape or mastic seal between the coil and furnace and the coil and plenum. WARNING:  When installed in a room with an area less than that outlined in Table 3, on Page 12. That room shall be without continuously operating open flames (For example an operating gas appliance) or other potential ignition sources (For example an operating electric heater, hot surfaces).

  2. Please use the Z-Bracket provided with units to fill the transition gap between the furnace & coil when the coil is one size large than an the furnace. Additional gaps must be filled with insulated tape or putty to prevent air leakage. Figure 4 indicates an incorrect coil/furnace attachment method.

  3. Optionally a transition duct can be used to attach the coil with furnace, if z-bracket is not preferred to be used (see Figure 5E and 5F).

  4. In case of CHPTA1822A coil match up with 80% furnace in horizontal right application, 90° elbow flue vent must be used and oriented away from the cased coil (see Figure 4A).

  5. In case of other cabinet sizes match up with 80% Furnace in Horizontal Right application, 2 qty of 90° elbow flue vent must be used. The horizontal run must be ≤ 75% of the vertical rise and no less than 1/4” upward rise per foot (see Figure 4B).

CAUTION: If the drain pan extension is not locked correctly, the airflow path will be blocked and flooding may occur.

**Drain Pan Extension

**

A drain pan extension is shipped with the coil in the accessory kit box (Figure 5A). This extension is to be used only for horizontal left application used only for higher than normal humid application. During horizontal right application, this drain pan extension is not required (There are accessories recommended for the horizontal right application, see page 4). This extension will have to be locked in position for proper application.

NOTE: To install drain pan extension, built-in duct flanges on the wrapper must be bended inward or outward as needed. Remove the drain pan extension from the accessory box rom a plastic bag. Follow illustration #4B below to install the drain pan extension.
To lock the extension, rotate downward away from the drain pan until snaps into position. It will act as an extension for the drain pan and must not be left loose or in the path of airflow.
The appliance shall be stored to prevent mechanical damage from occurring.

The drain pan extension (black plastic part in this kit) must be

installed in all horizontal left applications. Refer to the IO manual for complete installation instructions.
Duct Attachment

This coil’s casing is perforated for duct attachment. However, duct flanges (Qty: 2) are shipped in a box from the Factory separately for the sides that have rails and perforation can not be used. These flanges are to be used over rails. Remove the center rail screw and lay over the flange on top of the rails, then attach the screw back on to secure the flange over the rails. For horizontal left application, there is only one rail (bottom) hence only one duct flange is needed and the other can be stored. For the horizontal right application, there are two rails (top & bottom), and both duct flanges should be used. Duct flanges can also be attached using all three screws for the rails if additional strength is needed.

Condensate Drain Piping

  • During cooling application, where damage from condensate overflow may occur, it is MANDATORY to install a secondary drain pan under the entire coil cabinet with a separate drain line properly sloped and terminated in an area visible to the owner to be able to see water discharge. This secondary drain pan can provide extra protection to the area under the unit should the primary drain plug up and overflow. For coils with “A” cabinets (14” wide), use a float switchthe the a  if the secondary drain line is not installed. Refer to product nomenclature from product specification literature to identify coil models with “A” cabinets. As expressed in our product warranty, we will not be liable for any damages, structural or otherwise due to the failure to follow this installation requirement.
  • The coil drain pan has a primary and an optional secondary drain with 3/4” NPT female connections. The connectors required can be 3/4” NPT male either PVC or metal pipe and should be hand tightened to a torque of no more than 37 in-lbs. To prevent damage to the drain pan connection. An insertion depth between .355 to .485 inches (3-5 turns) should be expected at this torque. If using a copper drain line, solder a short piece of pipe to the connector before installing a drain fitting. Over over over over torque the 3/4” copper connector to the plastic drain connection. Insulate PVC drain lines/pipes with high heat resistive tape within the 1” furnace flue/vent pipe. Foil-mastic sealant tape is the preferred wrapping material.
    1. Ensure the drain pan hole is NOT obstructed.
    2. To prevent potential sweating and dripping on finished space, it may be necessary to insulate the condensate drain line located inside the building. Use Armaf-lex® or similar material.

A secondary condensate drain connection has been provided for areas where the building codes require it. Pitch the drain line 1/4” per foot to provide free drainage. Insulate drain lines (primary and secondary) located inside the building to prevent sweating. Install a condensate trap in the primary drain line to ensure proper drainage. If the secondary line is required, run the line separately from the primary drain and end it where it can be easily seen.

NOTE : Water coming from this line means the coil primary drain is plugged and needs clearing.

CAUTION: If the secondary drain is not installed, the secondary access must be plugged.

NOTE : Trapped lines are required by many local codes. In the absence of any prevailing local codes, please refer to the requirements listed in the Uniform Mechanical Building Code. A drain trap in a draw-through application prevents air from being drawn back through the drain line during fan operation thus preventing condensate from draining, and if connected to a sewer line to prevent sewer gases from being drawn into the airstream during blower operation. In a blow-through application, the drain trap prevents conditioned air from escaping.

The installation must include a “P” style trap that is located as close as is practical to the evaporator coil. See Figure 7 for details of a typical condensate line “P” trap.

NOTE : Units operating in high static pressure applications may require a deeper field construct-ed “P” style trap than is shown in Figure 7 to allow proper drainage and prevent condensate overflow.
Use of a condensate removal pump is permitted when necessary. This condensate pump should have provisions for shutting off the control voltage should a blocked drain occur. A trap must be installed between the unit and the condensate pump.

IMPORTANT NOTE : The evaporator coil is fabricated with oils that may dissolve Styrofoam and certain types of plastics. Therefore, a removal pump or float switch must not contain any of these materials.

TIP : Priming the “P” trap may avoid improper draining at the initial installation and the beginning of the cooling season.

Horizontal Right Coil Accessories

In applications where the horizontal coil is installed in the right position, and the return air environment sees a humidity level above 65% relative humidity coupled with total external static levels above 0.5” e.s.p, a condensate management accessory kit is available for field application. Sold separately, please refer to kit installation instruction IOG-7008.

Sensor and Accessory Wiring

  • Refer to the table 3 for minimum conditioned room area requirements.
  • R32 sensor fault codes should be referenced through the corresponding R32-equipped furnace or accessory IO manuals.
  • It is the installer’s responsibility to ensure that the mitigation mode is operational.
  • The sensor is not intended for service or repair. If the sensor is not functioning properly, mitigation mode will engage and the sensor must be replaced by removing the old sensor from the bracket and re-installing with new push-pins and a zip-tie. The R32 sensor shall only be replaced with sensors specified by the appliance manufacturer. (Sensor replacement part can be determined through the homeowner support line provided earlier in this document.)

All wiring installed in the field to be used in conjunction with the Sensor must meet the following minimum specification:

  • 18 AWG
  • 1.58mm insulation thickness or protected from damage

If the sensor used in this unit must be routed through the Non-A2L Furnace Integration Kit accessory component control board, then reference the Non-A2L Furnace Integration Kit installation manual for further instructions.

Any accessories that may become a potential ignition source, must be installed on our accessory control board. Ensure that any additional wiring from the cased coil is done to protect from damage and wear, avoiding the flue pipe and any joints that may need to be brazed or disconnected for service. If a zone control system is installed in the ductwork attached to this system, the zone controller must be powered through a zoning kit to ensure that the zoning dampers actuate during mitigation mode. Refer to the product specification sheet for the zoning and accessory control board kit part number.

Check that wiring will not be subject to wear, corrosion, excessive pressure, vibration, sharp edges, or any other adverse environmental effects. The check shall also take into account the effects of aging or continual vibration from sources such as compressors or fans.

Refrigerant Lines

CAUTION: The coil is shipped under pressure with a dry nitrogen gas mixture. Use appropriate service tools and follow these instructions to prevent injury.

WARNING

  • A quenching cloth is strongly recommended to prevent scorching or marring of the equipment finish when brazing close to the painted surfaces. Use brazing alloy of 5% minimum silver content.
  • ONLY BRAZING TECHNIQUES AND APPROVED MECHANICAL JOINTS SHOULD BE USED TO CONNECT REFRIGERANT TUBING CONNECTIONS. NON-APPROVED MECHANICAL CONNECTORS AND OTHER METHODS ARE NOT PERMITTED IN THIS SYSTEM CONTAINING A2L REFRIGERANT. APPROVED MECHANICAL JOINTS WILL BE DETAILED IN THE PRODUCT’S SPECIFICATION SHEETS.
  • WORK SHALL BE UNDERTAKEN UNDER A CONTROLLED PROCEDURE TO MINIMIZE THE RISK OF FLAMMABLE GAS OR VAPOR BEING PRESENT WHILE THE WORK IS BEING PERFORMED.

All cut ends are to be roububurr-freecleannn other condition increases the chance of a refrigerant leak. Use a pipe cutter to remove the closed end of the spun closed suction line. To avoid overheating after brazing, quench all welded joints with water or a wet rag. For the correct tubing size, follow the specification for the condenser/heat pump Follow standards related to ASHRAE 15, ASHRAE 15.2, IAPMO Uniform Mechanical Code, ICC International Mechanical andandCode o,r CSA B52 during any installation. Piping must be accessible for insbeforeingforeeing covered or enclosed in compliance with national and local codes. The indoor equipment and pipes must be securely momountednd guarded such that accidental rupture of equipment cannot occur from such events as moving furniture or rereconstructionctivities. Field-made refrigerant joints indoors shall be tightness tested. The test method shall have a sensitivity of 5 grams per year of refrigerant or better under a pressure of at least 0.25 times the maximum allowable pressure. No leak shall be detected (Should be leleak-tight Field pipework must be pressure tested with an inert gas and then vacuum tested before refrigerant charging according to the following requirements:

Standing Pressure Test
(Recommended before vacuum)
Using dry nitrogen or dry helium, pressurize the system to 460 PSIG. Allow the pressure to stabilize and hold for 15 Minutes (minimum). The system is considered leak-free if the pressure does not drop below 460 PSIG. If, after 15 Minutes, the pressure drops below 460 PSIG, it implies a leak in the system. Proceed with identifying and sealing the leak and repeating the Standing Pressure Test. Leak test the system using dry nitrogen or dry helium and soapy water to identify leaks. No refrigerant shall be used for pressure testing to detect leaks. Proceed to system evacuation using the Deep Vacuum Method.

Deep Vacuum Method
The Deep Vacuum Method requires a vacuum pump rated for 500 microns or less. This method effectively and efficiently ensures the system is free of non-condensableair and moisture. The Triple Evacuation Method is detailed in the Service Manual for this product model as an alternative. To expedite the evacuation procedure, it is recommended that the Schrader Cores be removed from the service valves using a core-removal tool.

  1. Connect the vacuum pump, micron gauge, and vacuum-rated hoses to both service valves. Evacuation must use both service valves to eliminate system mechanical seals.
  2. Evacuate the system to less than 500 microns.
  3. Isolate the pump from the system and hold the vacuum for 10 minutes (minimum). Typically, pressure will rise slowly during this period. If the pressure rises to less than 1000 microns and remains steady, the system is considered leak-free; proceed to system charging and startup.
  4. If pressure rises above 1000 microns but holds steady below 2000 microns, non-condensable air or moisture may remain, or a small leak may be present. Return to step 2: If the same result is achieved, check for leaks and repair. Repeat the evacuation procedure.
  5. If pressure rises above 2000 microns, a leak is present. Check for leaks and repair them. Then, repeat the evacuation procedure.

NOTE : Tubes of smaller size require less heat to bring the tube to brazing temperature before adding brazing alloy. The use of a heat shield when brazing is recommended to avoid burning the serial plate or the finish on the unit.

Refrigerant tubing must be routed to allow adequate access for servicing and maintenance of the unit. Do not handle coil assembly with manifold or flowrate tubes. Doing so may result in damage to the tubing joints. Always use clean gloves for handling coil assemblies.

CAUTION: Applying too much heat to any tube can melt the tube. Torch heat required to braze tubes of various sizes must be proportional to the size of the tube. Service personnel must use the appropriate heat level for the size of the tube being brazed.

Tubing Size/Length
For the correct tubing size, follow the specifications for the condenser/heat pump. Give special consideration to minimizing the length of refrigerant tubing when install-ing coils. Refer to Remote Cooling/Heat Pump Techni-cal Publication TP-110 Long Line Set Application for guidelines for line lengths over 80’. Leave a minimum 3” straight in-line set from braze joints before any bends.

Tubing Preparation
All cut ends are to be round, burr-free, and clean. Any other condition increases the chance of a refrigerant leak. Use a pipe cutter to remove the closed end of the spun closed suction line.

WARNING
This unit must be charged with R-32 refrigerant. Ensure that the sensor is installed correctly and is operational.

Installation of pipe work must be kept to a minimum. Pipe work including piping material, pipe routing, and installation must be protected from physical damage and shall not be installed in an unventilated space. Equipment piping in any occupied space shall be installed in such a way as to protect against accidental damage in operation and service. Precautions must be taken to avoid excessive vibration or pulsation to refrigeration piping. Protection devices, piping, and fittings shall be protected as far as possible against adverse environmental effects, for example, the danger of water collecting and freezing in relief pipes or the accumulation of dirt and debris. Steel pipes and components shall be protected against corrosion with a rustproof coating before applying any insulation. Any solenoid valves and piping in the refrigerant systems must be so designed and installed to minimize the likelihood of hydraulic shock damaging the system. Solenoid valves must not block in liquid refrigerant unless adequate relief is provided to the refrigerant system’s low-pressure side. Provisions must be made for the expansion and contraction of long runs of piping.

Brazing
Braze joints should be made only with the connections provided external to the cabinet. Do not alter the cabinet or braze inside the cabinet. To avoid overheating after brazing, quench all brazed joints with water or a wet rag. This system must be charged with R32 refrigerant to operate safely.

When breaking into the refrigerant circuit to make repairs – or for any other purpose – conventional procedures shall be used. However, for flammable refrigeranbest practices must bes be followed since flammability is a consideration. The following procedure shall be adhered to:

  1. Safely remove refrigerant following local and national regulations;
  2. Evacuate;
  3. Purge the circuit with inert gas;
  4. Evacuate;
  5. Continuously flush or purge with inert gas when using a flame to open the circuit; and
  6. Open the circuit.

For appliances containing flammable refrigerants, refrigerant purging shall be achieved by breaking the vacuum in the system with oxygen-free nitrogen and continuing to fill until the working pressure is achieved, then vent-ing to the atmosphere, and finally pulling down to a vacuum (optional for R32). This process shall be repeated until no refrigerant is within the system (optional for R32). When the final oxygen-free nitrogen charge is used, the system shall be vented down to atmospheric pressure to enable work to take place. The outlet for the vacuum pump shall not be close to any potential ignition sources, and ventilation shall be available.

NOTE : To prevent possible damage to the tubing joints, do not handle coil assembly with mani-fold or flow rate tubes. Always use clean gloves when handling coil assemblies.

Tubing Connections for TXV Version
TXV models come with factory-installed adjustable TXV with the bulb permanently located on the suction tube.

WARNING: Field-installed TXV Metering devices, including Piston kits and EEV, must be housed within the cabinet. Do not install external of the unit.

  1. Remove the coil access panel and rubber grommets.
  2. Remove the access valve fitting cap and depress the valve stem in the access fitting to release pressure. No pressure indicates a possible leak.
  3. Reinstall the coil access panel & rubber grommets.
  4. Remove the spin closure on both the liquid and suction tubes using a tubing cutter. DO NOT USE A CUTTING METHOD THAT WOULD RESULT IN THE GENERATION OF COPPER SHAVINGS OR COPPER DUST.
  5. Insert liquid line set into liquid tube expansion and slide grommet about 18” away from braze joint.
  6. Insert suction line set into suction tube expansion and slide insulation and grommet about 18” away from braze joint.
  7. Braze suction and liquid line joints.

CAUTION: Excessive torque can cause the TXV retaining ring to weaken & create a leak. This will make it difficult to reinstall. The proper torque settings should be configured as below when adjusting. The oiled equalizer should be set to 10-12 ft/lbs. Outlet and inlet chat fitting should be set to 15-20 ft/lbs.

Thermal Expansion Valve System Adjustment
The following information for the indoor unit should be verified before attempting to charge the system or adjust TXV if necessary.

  1. The total static pressure is .5” WC or less.
  2. Airflow is correct for an installed unit.
  3. Airflow tables are in the installation manual and spec sheet for the indoor unit.
  4. Complete airflow tables and charging information are in the service manual.
  5. The outdoor temperature must be 60°F or higher.
  6. Set the room thermostat to COOL, fan switch to AUTO
  7. Set the temperature control well below room temperature.

Superheat adjustments should not be made until indoor ambient conditions have stabilized. This could take up to 24 hours depending on indoor temperature and humidity. Before checking superheat run the unit in cooling for 10 minutes or until refrigerant pressures stabilize. Use the following guidelines and methods to check unit operation and ensure that the refrigerant charge is within limits.

NOTE : Charge two-stage units on a low stage.

NOTE : In situations where the TXV must be removed and replaced or re- installed into the system, the TXV should be hand-tightened first and then applied a half turn to fully set the TXV. No more than 20 ft-lb torque should be applied to the joints of the TXV.

NOTE : Do NOT adjust the charge based on suction pressure unless there is a gross undercharge.

  • SUBCOOL FORMULA = SAT. LIQUID LINE TEMP. – LIQUID LINE TEMP.
  • SUPERHEAT FORMULA = SUCT. LINE TEMP. – SAT. SUCT. TEMP.

In addition to conventional charging procedures, the following requirements shall be followed:

  1. Ensure that contamination of different refrigerants does not occur when using charging equipment. Hoses or lines shall be as short as possible to minimize the amount of refrigerant contained in them.
  2. A2L refrigerant cylinders shall be kept in an appropriate position according to the instructions.
  3. Ensure that the refrigeration system is grounded before charging the system with refrigerant.
  4. Label the system when charging is complete (if not already).
  5. Extreme care shall be taken not to overfill the refrigerating system.

Before recharging the system, it shall be pressure-tested with the appropriate purging gas. The system shall be leak-tested on completion of charging but before commis-sioning. A follow-up leak test shall be carried out before leaving the site.

  1. Purge gauge lines. Connect service gauge manifold to base valve service ports.
  2. Temporarily install a thermometer on the liquid line at the liquid line service valve and 4-6” from the compressor on the suction line. Ensure the thermometer makes adequate contact and is insulated for the best possible readings. Use liquid line temperature to determine subcooling and vapor temperature to determine superheat.
  3. If subcooling and superheat are low, adjust TXV superheat, then check subcooling as specified in the Outdoor Installation and Instruction manual.
  4. If subcooling is low and superheares is high, add a charge to raise subcooling to 8°F +/- 1°F, then check to superheat.
  5. If subcooling and superheat are high, adjust TXV superheat, then check subcooling as specified in Outdoor Installation and Instruction manual.
  6. After adjustments are complete reinstall cap on adjust-ment stem and tighten 1/6 turn.
  7. Remove gauges and check the Schrader ports for leaks and tighten valve cores if necessary. Install caps finger tight.

For optimum system performance subcool and superheat should be matched as specified in Outdoor Installation and Instruction manual. Outdoor should be matched with approved AHRI combination, other approved systems shall have subcooling set to 8°F ± 1°F and superheat set to 12°F ± 1°F.

NOTE : The minimum time between TXV adjustments shall be 20 minutes.

Under no circumstances shall potential sources of ignition be used in the search for or detection of refrigerant leaks. A halide torch (or any other detector using a naked flame) shall not be used. If a leak is suspected, all naked flames shall be removed/extinguished. If a leakage of refrigerant is found that requires brazing, all of the refrigerants shall be recovered from the system, or isolated (using shut-off valves) in a part of the system remote from the leak.

The following leak detection methods have been deemed acceptable, provided proper care is taken in their implementation:

  1. Electronic leak detectors are rated for use with R32 refrigerant. Ensure the detection equipment is calibrated in a refrigerant-free area and that the leak detector itself is not a potential source of ignition. Leak detection equip-ment shall be set at a value of no more than 0.075 kg/m³.
  2. Leak detection fluids – such as the bubble method or fluorescent method. Ensure that the use of detergents containing chlorine is avoided as the chlorine may react with the refrigerant and corrode the pipe work.

Saturated Suction Pressure

Temperature Chart


Suction Pressure

| Saturated Suction Temperature ºF
PSIG| R32
50| 0.57
52| 2.06
54| 3.51
56| 4.94
58| 6.33
60| 7.69
62| 9.03
64| 10.34
66| 11.62
68| 12.88
70| 14.12
72| 15.34
74| 16.53
76| 17.70
78| 18.86
80| 19.99
85| 22.75
90| 25.41
95| 27.97
100| 30.44
110| 35.16
120| 39.59
130| 43.79
140| 47.76
150| 51.55
160| 55.17
170| 58.64

Table 1

Saturated Liquid Pressure

Temperature Chart


Suction Pressure

| Saturated Liquid Temperature ºF
PSIG| R32
200| 68.25
210| 71.23
220| 74.11
225| 75.50
235| 78.25
245| 80.91
255| 83.50
265| 86.03
275| 88.48
285| 90.86
295| 93.19
305| 95.46
325| 99.85
355| 106.08
375| 110.02
405| 115.65
415| 117.46
425| 119.24
435| 120.98
445| 122.70
475| 127.68
500| 131.65
525| 135.48
550| 139.17
575| 142.73
600| 146.17
625| 149.50

Table 2

Altitude adjustment factor to calculate min room area.

The indoor equipment mitigation requirements, as seen on table 3, are calculated at sea level.

Cased Coil Mitigation Chart



Model

| ****

Minimum Air Conditioned Room Area


(m²)

| ****

Minimum Air Conditioned Room Area


(ft²)

| Minimum Mitigation Airflow


m 3/ hr

| ****

Minimum Mitigation Airflow


(CFM)

1.5T Match-up| 13.26| 142.68| 437.43| 257.46
2.0T Match-up| 13.47| 145.03| 444.63| 261.70
2.5T Match-up| 14.46| 155.60| 477.05| 280.78
3.0T Match-up| 17.27| 185.87| 569.85| 335.40
3.5T Match-up| 18.91| 203.49| 623.87| 367.20
4.0T Match-up| 20.32| 218.77| 670.69| 394.75
5.0T Match-up| 20.87| 224.64| 688.70| 405.35

It is the installer’s responsibility to verify that actuation of mitigation procedures are operational with minimum required airflow according to the chart.

Table 3
For higher altitudes adjust the minimum room area specified on the Serial Plate by the corresponding altitude adjustment factor shown below. This table is provided as a reference. Adjusted room area (Amin adj) is the product of the mini-mum room area specified in the serial plate and the adjust-ment factor AF, as shown in below formula  Amin adj = Amin (serial plate) * AF

Height in meters| Height in feet| Altitude Adjustment Factor (AF)
---|---|---
At sea level| At sea level| 1.00
1~200| 1~660| 1.02
200~400| 660~1320| 1.03
400~600| 1320~1970| 1.05
600~800| 1970~2630| 1.07
800~1000| 2630~3290| 1.09
1000~1200| 3290~3940| 1.11
1200~1400| 3940~4600| 1.13
1400~1600| 4600~5250| 1.15
1600~1800| 5250~5910| 1.17
1800~2000| 5910~6570| 1.19
2000~2200| 6570~7220| 1.21
2200~2400| 7220~7880| 1.24
2400~2600| 7880~8540| 1.26
2600~2800| 8540~9190| 1.29
2800~3000| 9190~9850| 1.31
3000~3200| 9850~10500| 1.34

Filler Plates

Filler plates are supplied on all 17.5, 21, & 24.5 inch chassis to be used for adapting the unit to a furnace one size small-er. If the plenum and furnace openings are the same size, the filler plates must be removed. See Figure 15.

Drain Line and Flue Vent Piping

A minimum of 2.0” distance from the top of the furnace and the bottom of the coil pan is required.

NOTE : The coil must be installed with the line set and drain openings to the front of the furnace.

Plastic Drain Pan Application

WARNING: Do not use the coil pan shipped with the unit on oil furnaces or any application where the temperature of the drain pan may exceed 300°F. A high temperature drain pan such as kits HTP-A, -B, -C, and -D for normal cabinet widths of 14, 17.5, 21 and 24.5 inches, respectively, should be used for applications where the temperature exceeds 300°F and below 450°F. A field fabricated metal drain pan can also be used for applications where temperature exceeds 300°F. Failure to follow this warning may result in property damage and/pr personal injury.

NOTE :

  • Water coming from the secondary line means the coil primary drain is plugged and needs immediate attention.
  • Install a trap in the drain line below the bottom of the drain pan. If using a copper drain line, solder a short piece of pipe, minimum 6” length, to the connector before installing a drain fitting.
  • DO NOT overtorque the 3/4” copper connector to the plastic drain connection. Using a wet rag or heatsink material on the short piece to protect the plastic drain pan, complete the drain line installation. Use Figure 7 as a template for typical drain pipe routing. This figure shows how to avoid interference with vent piping.

Return Ductwork
DO NOT TERMINATE THE RETURN DUCTWORK IN AN AREA THAT CAN INTRODUCE TOXIC OR OBJECTIONABLE FUMES/ODORS INTO THE DUCTWORK.

WARNING: All required ventilation openings must be clear of obstruction and all ducts connected to the appliance free of potential ignition sources.

Sealing Along The Panel Gap

  • For appliances using A2L REFRIGERANTS, connected via an air duct system to one or more rooms, the supply and return air shall be directly ducted to the space. Open areas such as false ceilings shall not be used as a return air duct
  • The air extraction opening from the room shall be located equal or below the refrigerant release point. For floor-mounted units, it shall be as low as practicable. The air extraction openings shall be located in a sufficient distance from the air intake openings to prevent re-circulation to the space.

IMPORTANT NOTE: To prevent cabinet sweating and airflow leak, apply field-provided insulation tape along all joining surfaces between the coil, gas furnace, ductwork and panels. See Figure 18.

Aluminum Indoor Coil Cleaning (Qualified Servicer Only)

R32 sensor must be removed from the unit before applying coil cleaners to avoid damage and contamination. Reas-semble the R32 sensor back to the unit after done with coil cleaning process. This unit is equipped with an aluminum tube evaporator coil. The safest way to clean the evaporator coil is to simply flush the coil with water. This cleaning prac-tice remains as the recommended cleaning method for both copper tube and aluminum tube residential evaporator coils.
An alternate cleaning method is to use one of the products listed in TP-109* to clean the coils. The cleaners listed are the only agents deemed safe and approved for use to clean round tube aluminum coils. TP-109 is also available on the web site in Partner Link > Service Toolkit.

NOTE : Ensure coils are rinsed well after use of any chemical cleaners.

Top flanges can be bent for ease in installation to the duct flanges.

WARNING: Do not use means to accelerate the defrosting process or to clean, other than those recommended by the manufacturer. The appliance shell be stored in a room without continuously operating ignition sources (For example: Open flames, an operating gas appliance or an operating electric heater). Do not pierce or burn. Be aware that refrigerants may not contain an odor.

Removing Coil from Cabinet

After service or replacement slide the coil back in the cabinet and secure the top tie rail and re-install access panel. See Figure 19.
If the coil is hitting the bottom wrapper flange of the cabinet, pinch the mental flange (wrapper flange) closed, so the drain pan can slide in and out on the rail. See Figure 20 for an example of the flange that may need to be pinched shut.

UV Accessory (optional)

  • The listed Clean Comfort brand UV coil purifiers models are the only models approved to be used with this unit. They can be purchased from the distributors. The use of the accessory control kit is optional for the installation of this models. Maximum UV lamp diameter to be used per delta plate knockout design is 1.375” to reduce the possibility of air leak.
  • The power source must be installed external of the unit. Ensure that the wiring is routed through the access panel knockout with the grommet included. The magnetic door switch must be installed to avoid any accidental Ultraviolet exposure during service.
  • The power supply must be installed in series with the approved Accessory Control Board.
  • Refer to UV coil purifiers product specification and installa-tion manual for additional details.

Approved UV-C Model Numbers

Models| Lamp
UC18S15-24| UCP-16013
UC18S15-24B| UCP-16012

Start-Up Procedure

WARNING: HIGH VOLTAGE
Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury or death.

  • Prior to start-up, ensure that all electrical wires are properly sized and all connections are properly tightened.
  • All panels must be in place and secured. For air tight application, gasket must be positioned at prescribed locations to achieve 1.4% leakage.
  • Tubing must be leak free.
  • Condensate line must be trapped and pitched to allow for drainage.
  • Low voltage wiring is properly connected.
  • Auxiliary drain is installed when necessary and pitched to allow for drainage.
  • Unit is protected from vehicular or other physical damage.
  • Return air is not obtained from, nor are there any return air duct joints that are unsealed in, areas where there may be objectionable odors, flammable vapors or products of combustion such as carbon monoxide (CO), which may cause serious personal injury or death.
  • Ensure that the equipped R32 sensor is wired to the Furnace PCB and that there are no sources of poten-tial ignition within the system.

IMPORTANT : The A2L verification step as described on the furnace IO or the Non-A2L Integration Kit IO must be completed.

Refrigerant Recovery

  • When removing refrigerant from a system, either for servic-ing or decommissioning, it is recommended good practice that all refrigerants are removed safely. When transferring refrigerant into cylinders, ensure that only appropriate refrigerant recovery cylinders are employed. Ensure that the correct number of cylinders for holding the total system charge are available. All cylinders to be used are designat-ed for the recovered refrigerant and labeled for that refrig-erant (i.e. special cylinders for the recovery of refrigerant). Cylinders shall be complete with pressure-relief valve and associated shut-off valves in good working order. Empty recovery cylinders are evacuated and, if possible, cooled before recovery occurs.
  • The recovery equipment shall be in good working order with a set of instructions concerning the equipment that is at hand and shall be suitable for the recovery of the flam-mable refrigerant. If in doubt, the manufacturer should be consulted. In addition, a set of calibrated weighing scales shall be available and in good working order. Hoses shall be complete with leak-free disconnect couplings and in good condition. The recovered refrigerant shall be processed according to local legislation in the correct recovery cylinder, and the relevant waste transfer note arranged. Do not mix refrigerants in recovery units and especially not in cylinders. If compressors or compressor oils are to be removed, ensure that they have been evacuated to an acceptable level to make certain that flammable refrigerant does not remain within the lubricant. The compressor body shall not be heated by an open flame or other ignition sources to accelerate this process. When oil is drained from a system, it shall be carried out safely.

Before you call your Servicer

  • Check the thermostat to confirm that it is properly set.
  • Wait 15 minutes. Some devices in the outdoor unit or in programmable thermostats will prevent compressor operation for awhile, and then reset automatically. Also, some power companies will install devices which shut off air conditioners for several minutes on hot days. If you wait several minutes, the unit may begin operation on its own.
  • Check the electrical panel for tripped circuit breakers or failed fuses. Reset the circuit breakers or replace fuses as necessary.
  • Check the disconnect switch near the indoor furnace or blower to confirm that it is closed.
  • Check for obstructions on the outdoor unit. Confirm that it has not been covered on the sides or the top. Remove any obstruction that can be safely removed. If the unit is covered with dirt or debris, call a qualified servicer to clean it.
  • Check for blockage of the indoor air inlets and outlets. Confirm that they are open and have not been blocked by objects (rugs, curtains or furniture).
  • Check the filter. If it is dirty, clean or replace it.
  • Listen for any unusual noise(s), other than normal oper-ating noise, that might be coming from the outdoor unit. If you hear unusual noise(s) coming from the unit, call a qualified servicer.

START-UP CHECKLIST

Air Handler / Coil

  • ELECTRICAL
    Line Voltage (Measure L1 and L2 Voltage)

  • Secondary Voltage (Measure Transformer Output Voltage)

  • Blower Amps

  • Heat Strip 1 – Amps

  • Heat Strip 2 – Amps

BLOWER EXTERNAL STATIC PRESSURE

  • Return Air Static Pressure
  • Supply Air Static Pressure
  • Total External Static Pressure (Ignoring +/- from the reading above, add total here)

TEMPERATURES

  • Return Air Temperature (Dry bulb / Wet bulb)
  • Cooling Supply Air Temperature (Dry bulb / Wet bulb)
  • Heating Supply Air Temperature
  • Temperature Rise
  • Delta T (Difference between Supply and Return Temperatures)

Air Handler / Coil – (Inverter Matched)
INVERTER AH / COIL ONLY

Check EEV and EEV wiring is secure (no adjustment required)

Additional Checks

  • Check wire routings for any rubbing
  • Check product for proper draining
  • Check screw tightness on blower wheel
  • Check factory wiring and wire connections
  • Check product for proper clearances as noted by installation instructions

°F to °C formula : (°F – 32) divided by 1.8 = °C

°C to °F formula: (°C multiplied by 1.8) + 32 = °F

CUSTOMER FEEDBACK
We are very interested in all product comments.

Please fill out the feedback form on one of the following links:

You can also scan the QR code on the right for the product brand you purchased to be directed to the feedback page.

PRODUCT REGISTRATION
Thank you for your recent purchase. Though not required to get the protection of the standard warranty, registering your product is a relatively short process, and entitles you to additional warranty protection, except that failure by California, Florida, and Quebec residents to register their product does not diminish their warranty rights. The duration of warranty coverages in Texas and Florida differs in some cases.

For Product Registration, please register as follows:

You can also scan the QR code on the right for the product brand you purchased to be directed to the Product Registration page.

NOTE : SPECIFICATIONS AND PERFORMANCE DATA LISTED HEREIN ARE SUBJECT TO CHANGE WITHOUT NOTICE

19001 Kermier Rd., Waller, TX 77484

Amana is a registered trademark of Maytag Corporation or its related companies and is used under license. All rights reserved.

FAQ

Q: Can this unit be installed outdoors?
A: No, this product is not designed or approved for outdoor use as per the manufacturer’s specifications.

Q: What refrigerant is approved for use with this equipment?
A: This equipment is approved for use with R32 Refrigerantonly.

Q: How should I handle shipping damage claims?
A: Inspect the product upon receipt, verify specifications, and contact the carrier for any shipping damage claims.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals