Danfoss RET-MD Electronic Intelligent Dial Setting Thermostat Installation Guide
- June 17, 2024
- Danfoss
Table of Contents
Danfoss RET-MD Electronic Intelligent Dial Setting Thermostat
Installation Instructions
Features | RET- MD |
---|---|
Power supply | 230 Vac ± 15%, 50/60 Hz |
Switching action | 1 SPDT volt free Type 1B |
Switch rating | 10-264 Vac, 3 (1) A |
Temperature range | 5-30°C |
Maximum ambient temp | 45°C |
Control pollution | Degree 2 |
Design standard | EN 60730-2-9 |
Rated impulse voltage | 2.5kV |
Ball hardness test | 75°C |
Dimensions (mm) | 85 wide x 86 high x 42 deep |
Mounting
Please Note
This product should only be installed by a qualified electrician or competent
heating installer and should be by the current edition of the IEEE wiring
regulations.
Fix at a height of 1.5m approx from the floor, away from draughts or heat sources such as radiators, open fires or direct sunlight.
Wiring
Note: For RET-MD live supply is from the Time Control output
DIL switch settings
Slide the DIL switches to the settings required.
ON/OFF – boiler switches ON when below set temperature and OFF when
above.
CHRONO – energy saving feature that fires the boiler at regular intervals
to maintain a set temperature, achieving a constant ambient environment for
the user.
- use 6 Cycles for radiator systems.
- use 3 Cycles for underfloor heating.
DELAY START
energy saving feature that automatically delays the heating start time,
depending on how close to the set point the ambient room temperature already
is (see chart below). For example, during milder weather, the heating start
time can be delayed to avoid wasting fuel by bringing rooms up to temperature
earlier than necessary.
Mounting (continued)
Locking & Limiting
Locking – setting the thermostat at a temperature that cannot be altered by
the user. Limiting – allowing the user to alter the temperature within a
predefined range, which is less than the full range of the product (i.e.
between 18-22°).
Resetting the unit
When power is first applied, remove the dial and press the RESET button for 2
seconds.
What is a room thermostat?
… an explanation for householders A room thermostat simply switches the
heating system on and off as necessary. It works by sensing the air
temperature, switching on the heating when the air temperature falls below the
thermostat setting, and switching it off once this set temperature has been
reached.
Turning a room thermostat to a higher setting will not make the room heat up any faster. How quickly the room heats up depends on the design of the heating system, for example, the size of the boiler and radiators. Neither does the setting affect how quickly the room cools down. Turning a room thermostat to a lower setting will result in the room being controlled at a lower temperature, and saves energy. The heating system will not work if a time switch or programmer has
The way to set and use your room thermostat is to find the lowest temperature setting that you are comfortable with, and then leave it alone to do its job. The best way to do this is to set the room thermostat to a low temperature – say 18°C – and then turn it up by one degree each day until you are comfortable with the temperature. You won’t have to adjust the thermostat further. Any adjustment above this setting will waste energy and cost you more money. If your heating system is a boiler with radiators, there will usually be only one room thermostat to control the whole house. But you can have different temperatures in individual rooms by installing thermostatic radiator valves (TRVs) on individual radiators.
If you don’t have TRVs, you should choose a temperature that is reasonable for the whole house. If you do have TRVs, you can choose a slightly higher setting to make sure that even the coldest room is comfortable, then prevent any overheating in other rooms by adjusting the TRVs. Room thermostats need a free flow of air to sense the temperature, so they must not be covered by curtains or blocked by furniture. Nearby electric fires, televisions, wall or table lamps may prevent the thermostat from working properly.
Display
The LCDs actual room temperature until the setting dial is moved.
Setting the temperature
Turn the setting dial to the required temperature. The selected temperature will flash in the LCD to signify it is showing a set temperature. After a short period, the display stops flashing and shows actual room temperature.
Understanding your thermostat
- If the green LED is lit the Time Control is activated.
- If the red LED is lit constantly, the heating is switched on.
- If the red LED is flashing, the Delay Start function is in operation.
- If the Save button is pressed while the heating is on, the Delay Start function will start. This can save energy by switching the heating off once the room is up to temperature for the duration of the delay period (refer to
- Delay Chart on page 9). Pressing the Save button a second time will return the thermostat to normal operation and the heating will start.
- If the green LED is on, but the red LED is off, the room temperature has been reached and the thermostat is satisfied. If more heat is required turn the setting dial to increase the set temperature.
For problems relating to your heating controls .
Visit our website: www.danfoss-randall.co.uk
Email our technical department: