USER’S OPERATING MANUAL FOR DIGITAL PRESET TIMER
(Models: KTM-446 / 776 / 996 / 666 )
SPECIFICATIONS :
Display
: Double 3 Digit 7-segment LED,
3 Digit Bright White (Running Time)
3 Digit Luminous Green ( S e t Time)
Model no. | KTM – 446 | KTM – 776 | KTM – 996 | KTM – 666 |
---|---|---|---|---|
Display height (PV) | 0.39″ | 0.56″ | 0.80″ | 0.39″ |
Display height (SV) | 0.24″ | 0.39″ | 0.56″ | 0.39″ |
Status Indication | : Time unit (Hrs. / Min. /Sec. ) |
Relay status (RL1/RL2)
Auto Reset / Hold Time
---|---
Time settings| : Through Keyboard
Control Inputs| a] StartInput b ] Reset
Reset time| :<100 ms
Timing Accuracy| :0.05% Full Scale
Repeat Accuracy| :0.01%
Outputs| :5Amp @ 230VAC Relay (1C/O) x 2
12 VDC@30mA for SSR Drive ( by order )
Reset| : a] Front switch (Programmable)
b ] Remote Reset (via rear terminals)
c] On power interruption (Programmable)
Supply| : 90 to 2 7 0 VAC
Mounting| : Panel
Housing| : ABS Plastic
Operatingtemp.| :0~50°C
Humidity| : 95% Rh (Non Condensing).
Configurable Parameters
Mode | : On delay/Off delay/CY1/CY2/CY3 |
---|---|
Range 1&2 | : 9.99 Sec. to 999 Hrs. ( Programmable ) |
Count direction | : Up/Down |
Timer Start | : Refer Programming |
Timer Function | : Auto Reset / Latched output |
Front Reset | : Enable / Disable |
Gate Input | : Enable / Disable |
Memory Backup | : Enable / Disable |
Output 2 Function | : Refer Programming |
OVER ALL DIMENSIONS & PANEL CUT OUT (IN MM)
MODEL:- KTM-446/ KTM-776/ KTM-996/ KTM-666
Dim / Mode| A| B| C| D| E| F| G|
H
---|---|---|---|---|---|---|---|---
KTM-446| 48| 48| 8| 75| 43| 44| 44|
9
KTM-776| 72| 72| 10| 65| 66| 68| 68|
9
KTM-996| 96| 96| 10| 45| 89| 92| 92|
9
KTM-666| 96| 48| 10| 45| 89| 92| 44|
9
INSTALLATION GUIDELINES
- Prepare the cut-out with proper dimension as shown in figure.
- Remove clamp from controller
- Push the controller through panel cut-out and secure the controller in its place by tightening the side clamp.
TERMINAL CONNECTIONS :
TYPICAL APPLICATION :
SAFETY INSTRUCTION
All safety related instruction appearing in this manual must be followed to ensure safety of the operator as well as the unit..
MECHANICAL
- Ambient temperature and relative humidity surrounding the Timer must not exceed the maximum specified limits..
- The Timer in its installed state must be protected against excessive electrostatic or electromagnetic interferences.
ELECTRICAL
- The Timer must be wired as per wiring diagram & it must . comply with local electrical regulation.
- The Electrical noise generated by switching inductive loads might create momentary Fluctuation in display, latch up, data loss or permanent damage to the instrument. To reduce this use snubber circuit across the load.
PROGRAMMING
USER LIST : To access the user list press & release SET key once.
PARAMETER | DISPLAY | RANGE | DESCRIPTION | DEFAULT |
---|---|---|---|---|
HOLD TIME | -0,100. S | HOLD TIME : Prompted only if selected mode is CY3 | ||
(Cyclic with Hold). | 5.0 |
Sets the HOLD time between motor Forward & Reverse.
SET TIME 1| | | 0 – 999| SET TIME 1 : Set time for On delay & Off delay modes.
On time for CY1| 10.0
& CY2 modes. Forward time for CY3 mode.
SET TIME 2| | | 0 – 999| SET TIME 2 : Prompted only if selected timer mode is
CY1, CY2 or CY3.| 10.0
It sets Off time for CY1 & CY2 modes& reverse time for CY3 mode.
NUMBER OF
CYCLES| | | 0 – 999| NUMBER OF CYCLES : Prompted only if selected timer mode
is CY1,| 0
CY2. It sets the number of cycles after which both the Relays will be OFF.
EOC TIME| | | 0 – 999| EOC TIME : OP2 function is set to EOC. This parameter
sets the End of| 5.0
cycle time ( Fixed in seconds)
TOTAL TIME| | | 0 – 999| TOTAL TIME . Available for CY3 mode only. In This
mode when Total| 0
s over (Programmed in Min. only); Both relays will be off. time is
CONFIGURATION LIST :
- To Enter in this mode press SET key for 6 sec. at Power On. “..-” Message will be displayed for 6 sec. Now unit will allow the user to configure different parameters with options as described below.
- Press “SET” Key to move on to next parameter.
- Press UP or DOWN Key to scroll between parameter options.
- All following parameters as shown in the shaded will be displayed on Lower Display
PARAMETER| LOWER
DISPLAY| UPPER
DISPLAY| DESCRIPTION| DEFAULT
---|---|---|---|---
TIMER
FUNCTION| | | ON DELAY : Outputs are de-energized at power on. It remains De-
energized after| ON
DELAY
start of timing cycle. After completions of timing cycle outputs are
energized.
OFF DELAY: Outputs are energized at the start of timing cycle. After
completions
of timing cycle outputs are de-energized.
CYCLIC WITH OFF TIME FIRST : Sti : Off-time
St2 : On-time
CYCLIC WITH ON TIME FIRST : Sri : On-time
St2 : Off-time
CYCLIC WITH HOLD TIME : StH : Hold Time
St1 : Forward-Time ; St2 : Reverse-Time
RANGE 1| | | TIMER RANGE & RESOLUTION : Range : 9.99 Sec.| 999 SEC.
Resolution : 0.01 Sec.
Range : 99.9 Sec.
Resolution : 0.1 Sec.
Range : 999 Sec.
Resolution : 1 Sec.
Range : 9 Min. 59 Sec.
Resolution : 1 Sec.
Range :99.9 Min.
Resolution : 0.1 Min.
Range :999 Min
Resolution : 1 Min.
Range : 9 Hrs. 59 Min.
Resolution :1 Min.
Range : 99.9 Hrs.
Resolution : 0.1 Hrs.
Range : 999 Hrs.
resolution : 1 Hrs.
RANGE 2| | | TIMER RANGE & RESOLUTION: Range : 9.99 Sec.|
Resolution : 0.01 Sec.
Range : 99.9 Sec.
Resolution : 0.1 Sec.
RANGE 2| | | Range :999 Sec.
Resolution : 1 Sec.| 999
SEC.
---|---|---|---|---
Range : 9 Min. 59 Sec.
Resolution : 1 Sec.
Range : 99.9 Min.
Resolution : 0.1 Min.
Range : 999 Min.
Resolution : 1 Min.
Range : 9 Hrs. 59 Min.
Resolution : 1 Min.
Range : 99.9 Hrs.
Resolution : 0.1 Hrs.
Range : 999 Hrs.
resolution : 1 Hrs.
HOLD
TIME| | | Hold Time :- This parameter will be prompted ONLY when timer
function selected as C
Enable : If selected, user can view & edit Hold time in user list.
Disable : If selected, user can only view th Hold Time but cannot edit it in
user list.| ENABLE
TIMER
DIRECTION| | | TIMER COUNTING DIRECTION :
UP COUNTING : If Selected, timer starts counting from 0 to set time in
ascending| DOWN
COUNT
order. ( Up direction )
DOWN COUNTING : If Selected, timer starts counting from Set time to 0 in
descending order. ( Down direction )
TIMER
START| | | TIMER START MODE : This parameter defines the Start mode for the
timer.| POWER
ON
START
POWER ON START : If Selected , Timer starts counting at Power On.
FRONT START : Timer starts only after user presses START key. If the cycle is
incomplete at the time of power fail , It will continue after power is
restored without need for re-issuing the Start command from front key ( If
MEM=On ). Not valid for CY3 mode
FRONT START : Timer starts only after user presses START key. If the cycle is
not over at the time of power fail, It will not start till the START command
is issued from the front panel (If MEM=On). Not valid for CY3 mode.
REMOTE START ( EDGE TRIGGERING ) Timer starts counting only when it
detects high to low pulse at back terminal from external Input.
REMOTE START WITH LEVEL SENSING Timer starts counting only when it
detects high to low pulse at back terminal from external Input. The input
signal must remain low during timing cycle otherwise timer will Reset.
TIMER
MODE| | | TIMER MODE : Prompted only if selected function is ON/OFF Delay &
start input is| LATCH
OUTPUT
other than power on start. For power on start this function is always set to
LO
BeideHED MODE : In this mode once the timing cycle is over, User must issue a
Reset signal from front key( if F.rt= On) or Ext. Reset input to re-start the
timer.
AUTO RESET MODE : In this mode once the timing cycle is over, Next start input
either thro’ Front panel or thro’ external input signal will re-start the
timer.
GATE
INPUT| | | GATE INPUT : Prompted only if Timer is configured for either power
on start or| NO
front start. When enabled ( Set to yes ) the external input can work as a Gate
input. DISABLE (nO) : The external input can not be used as a Gate input.
ENABLE (YES) : The external input can be used as a Gate input.
FRONT
RESET| | | FRONT RESET ENABLE/DISABLE : This parameter allows the user to
Enable or| YES
Disable front Reset function. This feature prevents un-authorized attempt to
Reset the Timer during Run mode.
DISABLE (nO) : The Timer can not be reset through front panel.
ENABLE (YES) : The Timer can be reset through front panel.
MEMORY
BACKUP| | | MEMORY BACKUP ENABLE/DISABLE : This parameter allows the user to|
NO
Enabe or Disable memory backup function.
DISABLE (nO) : No memory backup for run time value.
ENABLE (YES) : Memory backup for run time value.
OUTPUT 2
FUNCTION| | | OUTPUT 2 FUNCTION : This parameter will be prompted only if
selected Timer| AUC
function is either ON or OFF delay. Not applicable for Cyclic modes.
END OF CYCLE OUTPUT : The OP2 is energized for rt period set in user list at
the
end of timing cycle.
AUXILLIARY CONTACT : The OP2 will operate simultaneously with OP1. This
function is required when user needs 2 changeover Relay contacts.
INSTANT CONTACT : The OP2 function as a instant contact which operates
immediately when timer starts & remains in that state till the start of next
cycle. OFF : The OP2 is not used & can be kept reserve for future use.
Function / Timing Waveforms
ABBREVIATION
EOC : END OF CYCLE
LATCH : LATCHED 0/P MODE
AUTO : AUTO RESET MODE
t : SET TIME
rt : END OF CYCLE TIME
tg : GATE PULSE PERIOD
CY 1
t1 : ON TIME
t2 : OFF TIME
CY2
t1 : OFF TIME
t2 : ON TIME
CY3
th : HOLD TIME
t1 : FORWARD TIME
t2 : REVERSE TIME
Mfgd by: Innovative Instruments & Controls LLP
206, New Sonal Link Service Industrial Premises Co-op Society Ltd,
Building No.2, Link Road, Malad (W), Mumbai – 400064.
Tel: 022-66939916/17/18;
E-mail : sales@itherm.co.in
Website : www.itherm.co.in