SUNNY MCU HZ Type Emergency Light User Manual

September 17, 2024
Sunny

MCU HZ Type Emergency Light

“`html

Specifications

  • Model: Self-Contained Emergency Light MCU Series

  • Types: MCU HZ Type, MCU NC Type

  • Control: LED AC, LED Charge/Full, LED Battery, LED Fail, LED 5
    sec, LED 30 mins, LED 60 mins

  • Features: Remote Testing, Dimmer, IR Receiver

Product Usage Instructions

Installation

  1. The unit can be installed on leveled ground or hung up
    securely.

  2. Ensure proper installation to prevent accidents or damage.

Operation

  1. Press and hold the ON Switch for about 3 seconds to activate
    the emergency lamps.

  2. To perform tests:

    • Press the 30min button for a 30-minute test.
    • Press the 60min button for a 60-minute test.
    • To cancel the test, press the OFF button.

Important Notes

  • Install indoors away from direct sunlight and moisture.
  • Store in temperatures under 25°C.
  • Charge the battery every 3 months for optimal performance.

FAQ

Initial Troubleshooting

Cause Problem What to do

Power not getting to the unit after plugging in. The LED AC
light does not turn on.| – Power socket might not have any power.
– Plug or socket is loose.
– AC fuse is blown.| – Check power supply.
– Check plug and socket.
– Contact customer service.
Emergency light does not turn on after power outage.| – Unit is not plugged in.
– Lamp is faulty.
– Circuit’s wiring is loose.
– DC fuse is blown.| – Check if unit is plugged in.
– Contact customer service.
Emergency light only turns on for a short time after power
outage.| – Battery not fully charged.
– Battery degraded.| – Fully charge the battery.
– Contact customer service for battery replacement.

Terms for Warranty and Service

  1. Fill in and mail the warranty registration form back to the
    company within 7 days of purchase to activate warranty.

  2. Warranty covers internal parts as specified with durations
    calculated from the date of purchase.

“`

USER MANUAL
Self-Contained Emergency Light MCU Series

MCU HZ Type MCU NC Type

LED AC LED Charge/Full LED Battery LED Fail LED 5 sec LED 30 mins LED 60 mins Switch ON/OFF Switch Test IR Receiver
Dimmer

Indicate that the unit is receiving power. Gives information on battery charging. Indicate battery voltage range Indicate error status. Indicate the unit is performing a 5 second test. Indicate the unit is performing a 30-minute test. Indicate the unit is performing a 60-minute test. Press to turn ON/OFF the lamp. (while the unit is not plugged in) For testing the device’s availability. (during normal circumstance) Infrared signal sensor used to receive signal from the infrared remote. Press to adjust the brightness level (only supported in the HZ models).

Remote Testing
5 30 60 secs mins mins

Status Indicators and Testing Buttons

Remote Testing

Features
1. Controlled by a highly intelligent 8-bit micro controller. 2. Automatic self-test system that is able to be set for every 1 or 6 months. The time,
date and duration of the automatic test can be set as desired. This will help to extend the life of the battery as well as lower the burden of maintenance on the user. 3. Testing can be activated remotely using the infrared remote. 4. The unit has a quick self-test function with durations of 5 seconds, 30 minutes and 60 minutes. 5. The brightness of the unit can be adjusted to 3 different levels for optimum brightness and operational time (only supported for units with the HZ lamp type). 6. Using high quality LEDs with a lifetime of over 50,000 hours, providing bright and constant illimitation throughout its operation. 7. The unit’s outer case is made from ABS UL94 V-O Flame Retardant plastic that is highly resistant to impact and corrosion.

Installation and Operation
1. The unit can be installed on leveled ground or hung up. 2. Install properly and securely to prevent accidents that could cause damage to the
unit or other people and property. 3. Press and hold the ON Switch for about 3 seconds. Both emergency lamps will
illuminate and the LED ON light on the unit will turn on indicating that the unit is operational. 4. Plug the unit into a power socket with a 220-240VAC power supply. The emergency lamp will remain on for about 5 seconds before turning off. 5. Press the Dimmer button to adjust the brightness of the unit (only supported in the HZ models). 6. When the unit is operational, tests can be performed using the Test button on the unit or remotely using the remote with the following options. – Press the 5sec button to perform a 5 second test, after which the unit will return to
normal operation. – Press the 30min button to perform a 30-minute test, after which the unit will return
to normal operation. – Press the 60min button to perform a 60-minute test, after which the unit will return
to normal operation. – To cancel the test, press the OFF button.
Note : When activating the self-test function whether through the remote or the buttonon the unit the test button will have the same function.
Important Note on Using the Unit
1. The unit should be installed indoors away from direct sunlight and rain or moisture. 2. The unit should be stored in temperatures under 25 Degree Celsius and the battery
should be charged every 3 months to maintain its operational life.

Initial Trouble Shooting

Cause

Problem

What to do

– Power not getting to the unit after plugging in. The LED AC light does not turn on.

– The power socket might not have any power.
– The plug or socket is loose. – The AC. fuse is blown.

– Check the 220-240VAC power supply.
– Check the plug and socket. – Contact customer service.

– Emergency light does not – The unit is not plugged in. turn on after the power went – The lamp is faulty. out. – The circuit’s wiring is loose.
– The DC fuse is blown.

– Check that the unit is plugged in. – Contact customer service. – Contact customer service. – Contact customer service.

– Emergency light only turns on for a short time after the power went out.

– The battery is not fully charged. – The battery has degraded.

– Fully charge the battery. – Contact customer service to
replace the battery

Dimension (mm)

FRONT VIEW

BACK VIEW

SIDE VIEW

How to use the remote
Remote Testing 5 30 60 secs mins mins

H 220 H 220 H 220

L 250
MCU HZ Type FRONT VIEW
L 250
MCU NC Type

197 L 250
BACK VIEW

W 80
SIDE VIEW

197 L 250

W 80

5 secs

Perform a 5 second test.

30 mins

Perform a 30-minute test.

60 mins

Perform a 60-minute test.

Increase the lamp’s brightness (only available with the HZ lamp type)
Decrease the lamp’s brightness (only available with the HZ lamp type)
Turn on/off the emergency lamp or cancel any test in progress.

H 230 H 230 H 230

Terms for Warranty and Service
1. The Warranty will only be covered if the customer fills in the “warranty registration form” and
mail the return part back to the company within 7 days from the day of purchase. If this is not
carried out the warranty will be considered void.
2. The warranty only covers the unit’s internal parts. The conditions and durations for the warranty of each part is as specified and the duration of the warranty is calculated from the date of purchase.
3. Please show your warranty card every time you contact our service center or the dealer you
purchased the product from. 4. Products that fall into the following category are considered not covered by the warranty.
The product was used in a way not specified in the manual. The product was used with accessories not meeting the required specifications specified in
the manual. The product seems to have been damaged from being dropped or from strong impact, for example, the parts are loose, dented, scrapped or misshapen. The product has been repaired or modified by personnel not authorized by our company.
The Warranty Void sticker is torn or removed. The product is damaged from careless use or incorrect maintenance, for example, the battery is swollen from overcharging, quick charging was used on the battery, the battery terminals have been short-circuited, the unit was used until the battery was completely discharged and not recharged immediately, the product was stored for long periods until the Battery Checker warning activates and still it is not plugged-in to charge or taking the battery to normal temperature conditions and not recharging it every 1 month. The product was stored in an unsuitable environment, for example, a location with moisture
or water vapor. The product was supplied with a faulty AC power supply such as electrical overvoltage, electrical current surges, or lightning strikes entering the AC power line. Damages from natural causes such as fire, being summered in fluids, humidity, chemicals or
force majeure. Damages from insects or animals.
Note : Please read the manual carefully before installation and operation to understand how to
properly operate the unit.

For any further questions about your product please feel free to contact SUNNY’s customer service department. Tel. (+66) 02-948-4450-2 E-mail: service@sunnyemergencylight.com

IsOn Import-Export Co., Ltd.
2915-2917 Ladprao Road, Klongjan, Bangkapi, Bangkok 10240

Read User Manual Online (PDF format)