SUNNY CU Series Emergency Light User Manual

September 17, 2024
Sunny

CU Series Emergency Light

“`html

Product Information

Specifications:

  • Model: CU Series
  • Power Supply: 220-240VAC
  • Material: ABS UL94 V-0 Flame Retardant Plastic
  • LED Lifetime: Over 50,000 hours

Product Usage Instructions

Installation:

  1. The unit can be installed on leveled ground or hung up
    securely.

  2. Plug the unit into a power socket with a 220-240VAC power
    supply.

Operation:

  1. LED indicators:

    • LED AC: Indicates power reception.
    • LED Charge/Full: Shows battery charging status.
  2. To turn on the lamp when not plugged in, press the ON switch.
    Press the OFF switch to turn it off.

  3. Remote Testing: Use the infrared remote to activate tests for
    different durations (5 sec, 30 mins, 60 mins).

Maintenance:

  1. Store the unit indoors away from direct sunlight and
    moisture.

  2. Charge the battery every 3 months to maintain operational
    life.

FAQ

Q: How often should I charge the battery?

A: The battery should be charged every 3 months to maintain its
operational life.

Q: Can I perform tests remotely?

A: Yes, testing can be activated remotely using the infrared
remote control provided.

Q: What should I do if I hear an audible warning from the

battery checker?

A: If you hear a warning, charge the unit until the warning
stops to ensure continued functionality.

“`

USER MANUAL
Self-Contained Emergency Light CU Series

Remote Testing
5 30 60 secs mins mins

LED AC. LED Charge/Full LED On LED 5 sec LED 30 mins LED 60 mins Switch On Switch Off IR receiver

indicate that the unit is receiving power. gives information on battery charging. indicate the unit is ready for operation. indicate the unit is performing a 5 second test. indicate the unit is performing a 30-minute test. indicate the unit is performing a 60-minute test. press to turn on the lamp (while the unit is not plugged in). press to turn off the lamp (while the unit is not plugged in). infrared signal sensor used to receive signal from the infrared remote.

Status Indicators and Testing Buttons

Remote Testing

Features
1. Controlled by a highly intelligent 8-bit micro controller. 2. Automatically self-test every 30 days and discharges the battery for 30 minutes to
help extend the life of the battery. 3. Testing can be activated remotely using the infrared remote. 4. Using high quality LEDs with a lifetime of over 50,000 hours, providing bright and
constant illimitation throughout its operation. 5. The unit’s outer case is made from ABS UL94 V-0 Flame Retardant plastic that is
highly resistant to impact and corrosion. 6. The battery monitoring circuit will give an audible warning when the battery’s charge
is about to be depleted, giving the user time to recharge it before draining completely. This will help to extend the life of the battery.

Installation and Operation
1. The unit can be installed on leveled ground or hung up. 2. Install properly and securely to prevent accidents that could cause damage to the
unit or other people and property. 3. Plug the unit into a power socket with a 220-240VAC power supply. The machine will
work automatically. 4. The LED AC will turn on indicating that the unit is receiving power. The LED
Charge/Full will be on when the battery is charging and will turn off when the battery is fully charged. 5. When the unit is operational, tests can be performed using the Test button on the unit or remotely using the remote with the following options. – Press the 5 sec button to perform a 5 second test, after which the unit will return
to normal operation. – Press the 30 mins button to perform a 30-minute test, after which the unit will return to normal operation. – Press the 60 mins button to perform a 60-minute test, after which the unit will return
to normal operation. – To cancel the test, press the OFF button. 6. An audible warning will sound from the battery checker in the following scenarios. – The unit has been stored for a long time causing the battery’s charge to fall extremely low. – The emergency light has drained the battery until it is almost completely exhausted.
Important Note on Using the Unit
1. When the unit is not in use always turn it off by pressing the “OFF” switch. 2. The unit should be installed indoors away from direct sunlight and rain or moisture. 3. The unit should be stored in temperatures under 25 Degree Celsius and the battery
should be charged every 3 months to maintain its operational life. 4. If there is an audible warning from the battery checker, charge the unit until the warning
stops. It could take between 10-15 hours to fully charge the battery.

Initial Trouble Shooting

Problem

Cause

What to do

– Power not getting to the unit after plugging in. The LED AC light does not turn on.

– The power socket might not have any power.
– The plug or socket is loose. – The AC. fuse is blown.

– Check the 220-240VAC power supply.
– Check the plug and socket. – Contact customer service.

– Emergency light does not turn on after the power went out.

– The unit is not plugged in. – The lamp is faulty. – The circuit’s wiring is loose. – The DC fuse is blown.

– Check that the unit is plugged in. – Contact customer service. – Contact customer service. – Contact customer service.

– Emergency light only turns on for a short time after the power went out.

– The battery is not fully charged. – The battery has degraded.

– Fully charge the battery.
– Contact customer service to replace the battery

– Constant audible warning can be heard from the unit.

– The battery checker is warning that the battery’s charge has fallen below the minimum level.

– Plug the unit in to charge the battery for about 10-15 hours.

H 230

Dimension (mm)
FRONT VIEW

L 250
BACK VIEW
197 L 250

H 230

SIDE VIEW
W 80

How to use the remote
Remote Testing 5 30 60 secs mins mins

5 secs

Perform a 5 second test.

30 mins

Perform a 30 minute test.

60 mins

Perform a 60 minute test.

Increase the lamp’s brightness (only available with the HZ lamp type)
Decrease the lamp’s brightness (only available with the HZ lamp type)
Turn on/off the emergency lamp or cancel any test in progress.

H 230

Terms for Warranty and Service
1. The Warranty will only be covered if the customer fills in the “warranty registration form” and
mail the return part back to the company within 7 days from the day of purchase. If this is not
carried out the warranty will be considered void.
2. The warranty only covers the unit’s internal parts. The conditions and durations for the warranty of each part is as specified and the duration of the warranty is calculated from the date of purchase.
3. Please show your warranty card every time you contact our service center or the dealer you
purchased the product from. 4. Products that fall into the following category are considered not covered by the warranty.
The product was used in a way not specified in the manual. The product was used with accessories not meeting the required specifications specified in
the manual. The product seems to have been damaged from being dropped or from strong impact, for example, the parts are loose, dented, scrapped or misshapen. The product has been repaired or modified by personnel not authorized by our company.
The Warranty Void sticker is torn or removed. The product is damaged from careless use or incorrect maintenance, for example, the battery is swollen from overcharging, quick charging was used on the battery, the battery terminals have been short-circuited, the unit was used until the battery was completely discharged and not recharged immediately, the product was stored for long periods until the Battery Checker warning activates and still it is not plugged-in to charge or taking the battery to normal temperature conditions and not recharging it every 1 month. The product was stored in an unsuitable environment, for example, a location with moisture
or water vapor. The product was supplied with a faulty AC power supply such as electrical overvoltage, electrical current surges, or lightning strikes entering the AC power line. Damages from natural causes such as fire, being summered in fluids, humidity, chemicals or
force majeure. Damages from insects or animals.
Note : Please read the manual carefully before installation and operation to understand how to
properly operate the unit.

For any further questions about your product please feel free to contact SUNNY’s customer service department. Tel. (+66) 02-948-4450-2 E-mail: service@sunnyemergencylight.com

IsOn Import-Export Co., Ltd.
2915-2917 Ladprao Road, Klongjan, Bangkapi, Bangkok 10240

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Sunny User Manuals

Related Manuals