SHOWVEN X-F1800 Circle Flamer User Manual

September 18, 2024
Showven

X-F1800 Circle Flamer

“`html

Specifications

  • Model: Circle Flamer X-F1800

  • Version: V3.1 2024/06

  • Manufacturer: Showven Technologies Co., Ltd.

  • Power Supply: Rated voltage consistent with equipment
    requirements

  • Operational Position: Horizontal only

  • Control Panel: LED Display Area, Safety Lock, Indicator Light,
    ON/OFF switch

  • Connections: 3-pin and 5-pin DMX IN/OUT, Power IN/OUT, Fuse,
    12V Battery Power Input, DC 9V-60V pyro signal port

Product Usage Instructions

Preparation

Before using the Circle Flamer X-F1800, ensure that all safety
precautions are followed:

  • Ensure qualified or skilled operators handle the device.
  • Check power supply compatibility and grounding.
  • Connect communication DMX cable and ensure firing is OFF.
  • Keep safety switch in TEST MODE before powering on.
  • Verify safety distances are met as per the manual.

Operation

Follow these steps for safe operation:

  1. Power on the machine after ensuring all safety measures are in
    place.

  2. Maintain a clear area to prevent anyone from entering the
    danger zone once the device is activated.

  3. Ensure operator has a clear view of the device for immediate
    show stoppage in case of danger.

  4. Use high-quality flame fluid and refill the tank carefully away
    from ignition sources.

Frequently Asked Questions (FAQ)

Q: Can the Circle Flamer X-F1800 be used vertically?

A: No, the device can only be placed horizontally for safe
operation as per the manual instructions.

Q: What should I do if the device fails to fire correctly?

A: Immediately shut down the machine and check for any issues.
Do not attempt to continue using it until the problem is
resolved.

Q: Is it necessary to have a CO2 fire extinguisher on

hand?

A: Yes, it is recommended to have a CO2 fire extinguisher and an
extinguishing blanket available in case of emergencies while using
the Circle Flamer X-F1800.

“`

USER MANUAL CIRCLE FLAMER X-F1800
V3.1 2024/06
Showven Technologies Co., Ltd.

Foreword
Thanks for choosing SHOWVEN CIRCLE FLAMER X-F1800, we wish it will bring you lots of exciting moments. Please read the following manual carefully before operating this product. Operate according to instructions is very important for safety, and can elongate the service life of the machine Strictly follow the instruction in the manual when operate CIRCLE FLAMER X-F1800. If you have any doubts, please contact SHOWVEN technologies Co., Ltd by info@showven.cn We assume the person who use or come in contact with the device are familiar with how the device should be handled. This includes proper use, maintenance and repair of the machine as defined in this user manual.
Warning
This product is only suitable for qualified or skilled operators who has experience with the technology of the device and is particularly informed about the types of fuel used by the device.
Unauthorized repair are prohibited, it may cause serious incident
Make sure power supply in consistent with the rated voltage of the equipment, and the socket must well grounded. Unplug and turn off the machine when not use
Before connect the power cable, communication DMX cable should well connected and ensure the command keep at firing OFF status. And safety switch on CIRCLE FLAMER X-F1800 stay at TEST MODE.
Before power on the machine, please check carefully the safety distance and make sure it meets the requirements in this manual.
The device can only be placed horizontally.
After turning on the device, no person allows to stay in the danger area. Ensure all persons that are part of the show be informed about the safety distance, risks and functions of the device
Always have a CO2 fire extinguisher and an extinguishing blanket in case of needed
If there be any doubt as to the safety operation of the device in any circumstances, the device should be taken out of service immediately. Be sure the device is in good operating condition before use. If fail to fire correctly, immediately shut down and check it accordingly
Be sure to use high quality flame fluid, otherwise, it is easily leads to failure or danger. Be careful when refill the flame fluid tank. Please keep flame fluid away from heat source, sparks, fire or other possibility of ignition. Do not smoke!
The operator responsible for the control of Circle Flamer must always have a clear view of the device, so that he/she can stop the show immediately when there is danger. The main AC power switch should near operator. So that operator can turn off the power of all devices in case of abnormal
The device shall not be altered and applied to other use purpose
Disclaimers:
SHOWVEN technologies Co., Ltd excludes liability for unsafe situations, accidents and damages resulting from:
1. Ignoring warnings or regulations as shown on circle flamer or this manual 2. Use for other applications or circumstances other than those indicated herein 3. Changes to the circle flamer, including use of non-original spare parts 4. Removed safety cover without authorization from SHOWVEN. 5. Use this machine by unqualified or untrained personnel. 6. Improper use of machine.

Functional Characteristics
Fluid driven flamer system with 210° swiveling angles Up to 88 preset firing sequences Nozzle front design, safer for operator Safety lock with switchable test mode Stainless steel nozzle, reliable and durable Double electromagnetic valves design for additional safety Double pump ensure stable pressure Fitted with 9-60V pyro signal interface, compatible with fireworks firing system Neutrik®powerCON TRUE1 in/out, Neutrik®3-pin & 5-pin DMX in/out Compatible with SHOWVEN original host controller
Technical Specifications
MODEL: X-F1800 DIMENSION: 590×360×370mm WEIGHT: 30kg VOLTAGE: AC100-120V or AC200-240V, 50/60Hz POWER: 380W USAGE IN RAIN: YES CONTROL: DMX, 9-60V pyro signal INTERFACE: Neutrik®powerCON TRUE1 IN/OUT
Neutrik® 3-pin& 5-pin XLR IN/OUT FLAME HEIGHT: up to 8-10m (no wind) FIRING ANGLES: 210°(±105°) FUEL: ISOPAR-G, H, L, M; ISOPROPANEL FUEL TANK CAPACITY: 10L FUEL CONSUMPTION RATE: 60ml/s(M), 30ml/s(L), 15ml/s(EL) EXT. BATTERY POWERED: YES Stereo Stand Hole: Yes, ( 36mm depth 88mm)
Structure of Circle Flamer

1.Handle 4.Fuel Bottle Area

2. Firing Head 5. Control Panel

3.Top Panel 6. Safety Loop

Diagram of bottom panel Rear Panel

1. LCD screen operate panel

2. Safety Lock

3. Indicator Light red

4. 3-pin DMX IN/OUT

5. 5-pin DMX IN/OUT

(5-PIN XLR IN can charge for wireless DMX pen through pin1 and 4, pin4 with DC5V power supply)

6. Power IN/OUT

7. Fuse

8. ON/OFF switch

9. 12V Battery Power Input

10. DC 9V-60V pyro signal port

Operation Panel

1. LED Display Area: RX: Radio receiving (reserved) DMX: DMX signal. Flash means DMX signal available, otherwise no DMX signal ERR: Light on when there is an error PUMP: Light on when pump is running
2. Button Functions: MENU: Switch interface to setup parameter +: Parameter Up -: Parameter Down ENTER: Confirm and save parameters (screen will flash when parameters saved) Note: screen display will switch to main interface if not press button in 10s.
3. Welcome Interface:

First Line: Product model and software version Second Line: Equipment series number
4. Main Interface:

First Line: DMX address Second Line: “P: 100” means Pressure100 (100=10bar); “V: 13.6” means internal voltage is 13.6V

5. Alert Message: Alert Message E0 Test Mode
E0 Factory Mode E0 Invert On
E0 FireForbidden E0 ExtIgnite ON

Why it appears Safety Switch at TEST MODE
Factory mode Invert function ON Fire Forbidden ON
Ext Ignite ON

How to remove Switch to USER MODE Switch to Normal mode
Set Invert to OFF Set Fire Forbidden to OFF
Set Ext Ignite to OFF

6. Error Message Error Message E1 Pressure Err
E2 P Relief Err E5 Voltage Err

Why it appears
Pressurize for 8s, if pressure value failed to reach target value Depressurize for 2.5s, if pressure
value 50% of target value
DC input < 10V or > 15v

E6 Tip Err

Machine slant over 45°

Reason / How to remove No fuel, pump failure, pipeline fuel leakage etc
reason, please check accordingly
Pressure release valve failure
Make sure DC input between 10-15V Tip setting set to OFF, or horizontal install
machine.

7. Interface setup:

Press “MENU” to switch through setup menu

Menu

Range

Explanation

Set DMX Address

1~512

DMX address setup

Angle Limit

Maxi. ANGLE : NO.1 – NO.15 Mini. ANGLE : NO.1 – NO.15

Restrict nozzle rotate angles: Set by “+” and “-” , and confirm by “ENTER”

Limit Test

OFF / ON

Test the angle limit function after setting angle limit.

Steps setting the angle limit and install angle blocks. a) Set the “Maxi. Angle” and “Mini. Angle”, press “ENTER” to save the changes.

b) Install the angel block plates.

c) Running the Limit Test by set it to ON, and press ENTER, nozzle will move from Mini. Angle to Maxi.

Angle, then to the middle.

d) After confirm the software angle limit control works well, then put angle limit rod at corresponding

Mini. Angle and Maxi. Angle. Running Limit test again to reconfirm the angle limit rod was correctly

installed.

8. Advanced Interface:

Press “MENU” 3s enter advanced interface, press “MENU” to switch interface, press “MENU” 3s can

back to main interface

Items

Contents

Description

OFF / Motor/ Pump / Igniter / Relief Valve / Jet Valve

1. Motor

Swiveling and stop at target angle.

Drive Test

2. Pump 3. Igniter

Pump running, if pressure reached the target value, the pump will not running.
Ignite 1s

4. Relief Valve

Relief valve will be on and off for 3 times

5. Jet Valve 1 6. Jet Valve 2

Safety lock located at USER MODE, pressure relief valve on, then related jet valve will be on and off for 3 times.

Ext Ignite Set Ext Sequence
Language Mode Select Tip Setting Head to middle
Invert
Motor Disabled
Default Parameter

OFF / ON 1~88
English / Chinese Normal Mode / Factory Mode
ON / OFF OFF / ON OFF / ON
OFF / ON
OFF / ON

Trigger through 9-60V Pyro igniter signal
Preset sequence triggered by pyro signal
Language switch
Factory mode is for test in factory only
Turn ON/OFF tip over function Channel 1=0, Firing head will back to middle position (NO.8) after running a preset sequence. When turned on, all angles will be mirrored. When turned on, the position of the firing head should be moved or set manually, and the motor of firing head will be disabled. (The flamer should be restarted before it takes effect.) Reset default parameter settings

Firing Angles:
The firing angle for CIRCLE FLAMER is ±105°, from the Audience Side view, there are altogether 15 firing angles as below.

Drive time for Effects:

Time needed for the motor drive from NO.8 to relevant angle.

No.

Angles

NO.1

-105°

NO.2

-90°

NO.3

-75°

NO.4

-60°

NO.5

-45°

NO.6

-30°

NO.7

-15°

NO.8

NO.9

15°

NO.10

30°

NO.11

45°

NO.12

60°

Drive time needed 170ms 150ms 130ms 110ms 90ms 70ms 50ms 0ms 50ms 70ms 90ms 110ms

NO.13

75°

130ms

NO.14

90°

150ms

NO.15

105°

170ms

For example for the motor drive from 0°to 45°, it need 90ms, when operator design a show to synchronize to music, this drive time must be calculated.

CIRCLE FLAMER X-F1800 Firing Sequences

CIRCLE FLAMER X-F1800 has 88 preset sequences, operator use related channel DMX value or sequence

No. to access certain sequence. Below, you can find sequence list and single ignitions. Single Ignition Sequence List

No.

Ignition angle

Description

Single shot Sequence

CH5 DMX

duration Duration Reference Value

1

-105°

Single Ignition SHORT flame

0.04s

0.19s

3-5

2

-90°

Single Ignition SHORT flame

0.04s

0.19s

6-7

3

-75°

Single Ignition SHORT flame

0.04s

0.19s

8-10

4

-60°

Single Ignition SHORT flame

0.04s

0.19s

11-12

5

-45°

Single Ignition SHORT flame

0.04s

0.19s

13-15

6

-30°

Single Ignition SHORT flame

0.04s

0.19s

16-17

7

-15°

Single Ignition SHORT flame

0.04s

0.19s

18-20

8

Single Ignition SHORT flame

0.04s

0.19s

21-22

9

15°

Single Ignition SHORT flame

0.04s

0.19s

23-25

10

30°

Single Ignition SHORT flame

0.04s

0.19s

26-28

11

45°

Single Ignition SHORT flame

0.04s

0.19s

29-30

12

60°

Single Ignition SHORT flame

0.04s

0.19s

31-33

13

75°

Single Ignition SHORT flame

0.04s

0.19s

34-35

14

90°

Single Ignition SHORT flame

0.04s

0.19s

36-38

15

105°

Single Ignition SHORT flame

0.04s

0.19s

39-40

16

-105°

Single Ignition LONG flame

0.34s

0.56s

41-43

17

-90°

Single Ignition LONG flame

0.34s

0.56s

44-45

18

-75°

Single Ignition LONG flame

0.34s

0.56s

46-48

19

-60°

Single Ignition LONG flame

0.34s

0.56s

49-50

20

-45°

Single Ignition LONG flame

0.34s

0.56s

51-53

21

-30°

Single Ignition LONG flame

0.34s

0.56s

54-56

22

-15°

Single Ignition LONG flame

0.34s

0.56s

57-58

23

Single Ignition LONG flame

0.34s

0.56s

59-61

24

15°

Single Ignition LONG flame

0.34s

0.56s

62-63

25

30°

Single Ignition LONG flame

0.34s

0.56s

64-66

26

45°

Single Ignition LONG flame

0.34s

0.56s

67-68

27

60°

Single Ignition LONG flame

0.34s

0.56s

69-71

28

75°

Single Ignition LONG flame

0.34s

0.56s

72-73

29

90°

Single Ignition LONG flame

0.34s

0.56s

74-76

30

105°

Single Ignition LONG flame

0.34s

0.56s

77-79

Step Sequences List

No. Ignition angle NO.

31

Step from 1-15

32

Step from 15-1

33

Step 5>8>11

34

Step 11>8>5

35

Step 6>10

36

Step 10>6

37 Step 4>6>8>10>12

38 Step 12>10>8>6>4

39 Step 8>6>10>4>12

40 Step 8>10>6>12>4

41

Step from 1-15

42

Step from 15-1

43

Step 5>8>11

44

Step 11>8>5

45

Step 6>10

46

Step 10>6

47 Step 4>6>8>10>12

48 Step 12>10>8>6>4

49 Step 8>6>10>4>12

50 Step 8>10>6>12>4

Description
SHORT flame Step sequence SHORT flame Step sequence SHORT flame Step sequence SHORT flame Step sequence SHORT flame Step sequence SHORT flame Step sequence SHORT flame Step sequence SHORT flame Step sequence SHORT flame Step sequence SHORT flame Step sequence LONG flame Step sequence LONG flame Step sequence LONG flame Step sequence LONG flame Step sequence LONG flame Step sequence LONG flame Step sequence LONG flame Step sequence LONG flame Step sequence LONG flame Step sequence LONG flame Step sequence

Nozzle movement
L -> R R -> L L -> R R -> L L -> R R -> L L -> R R -> L M>L>R>L>R M>R>L>R>L L -> R R -> L L -> R R -> L L -> R R -> L L -> R R -> L M>L>R>L>R M>R>L>R>L

Sequence Duration
2.66s 2.66s 0.92s 0.92s 0.75s 0.75s 1.27s 1.27s 1.60s 1.60s 7.78s 7.78s 1.82s 1.82s 1.25s 1.25s 2.68s 2.68s 2.88s 2.88s

CH5 DMX Reference
Value 80-81 82-84 85-86 87-89 90-91 92-94 95-96 97-99 100-101 102-104 105-107 108-109 110-112 113-114 115-117 118-119 120-122 123-124 125-127 128-130

Wave Sequence List

No. Ignition angle NO.

51

Wave 5 –>11

52

Wave 11–>5

53

Big wave 1–15

54

Big wave 15–1

55

Wave 8–>1

56

Wave 8–>15

57

Wave 1–>8

58

Wave 15–>8

59

Wave 8–>11

60

Wave 8–>5

61

Wave 5–>8

62

Wave 11–>8

Description
Middle wave sequence Middle wave sequence LONG wave sequence LONG wave sequence Middle wave sequence Middle wave sequence Middle wave sequence Middle wave sequence SHORT wave sequence SHORT wave sequence SHORT wave sequence SHORT wave sequence

Nozzle movement
L -> R R -> L L -> R R -> L M -> L M -> R L -> M R -> M M -> R M -> L L -> M R -> M

Sequence Duration
1.87s 1.87s 4.08s 4.08s 2.09s 2.09s 2.31s 2.31s 0.99s 0.99s 1.08s 1.08s

CH5 DMX Reference Value
131-132 133-135 136-137 138-140 141-142 143-145 146-147 148-150 151-152 153-155 156-158 159-160

Additional Sequences List No. Ignition angle NO.

63

Step 3>13

64

Step 13>3

Description
SHORT flame Step sequence
SHORT flame Step sequence

Nozzle Sequence movement Duration

L -> R

0.93s

R -> L

0.93s

CH5 DMX Reference
Value 161-163
164-165

65

Step 3>13

LONG flame Step sequence L -> R

1.63s

66

Step 13>3

LONG flame Step sequence R -> L

1.63s

67

Step 8-13

SHORT flame Step sequence

M -> R

1.55s

68

Step 13-8

SHORT flame Step sequence

R -> M

1.55s

69

Step 8-13

LONG flame Step sequence M -> R

3.24s

70

Step 13-8

LONG flame Step sequence R -> M

3.24s

71

Step 8-3

72

Step 3-8

SHORT flame Step sequence
SHORT flame Step sequence

M -> L L -> M

1.54s 1.54s

73

Step 8-3

LONG flame Step sequence M -> L

3.24s

74

Step 3-8

LONG flame Step sequence L -> M

3.24s

75

Step 3-13

76

Step 13-3

SHORT flame Step sequence
SHORT flame Step sequence

L -> R R -> L

1.98s 1.98s

77

Step 2-14

SHORT flame Step sequence

L -> R

2.32s

78

Step 14-2

79

Step 8>5>11

SHORT flame Step sequence
SHORT flame Step sequence

R -> L M>L>R

2.32s 0.93s

80

Step 8>11>5

SHORT flame Step sequence

M>R>L

0.93s

81

Step 5-11

82

Step 11-5

SHORT flame Step sequence
SHORT flame Step sequence

L -> R R -> L

1.28s 1.28s

83

Wave 8–>13

Middle wave sequence

M -> R

1.70s

84

Wave 13–>8

Middle wave sequence

R -> M

1.70s

85

Wave 8–>3

Middle wave sequence

M -> L

1.60s

86

Wave 3–>8

Middle wave sequence

L -> M

1.60s

87

Wave 3–>13

LONG wave sequence

L -> R

3.06s

88

Wave 13–>3

LONG wave sequence

R -> L

3.06s

89

8(0°)

Single Ignition LONG flame Static

max. 8s

166-168 169-170 171-173
174-175 176-178 179-181 182-183
184-186 187-188 189-191 192-193
194-196
197-198
199-201
202-203
204-206
207-209
210-211 212-214 215-216 217-219 220-221 222-224 225-226 227-255

DMX CONTROL

CIRCLE FLAMER X-F1800 occupies 6 channels.

Channel

Function

Value

CH1

Manual Angle setup

0~255: angle change from -105° to 105° 128: straight upward (0°)

CH2

Manual Nozzle Waving 0 and 255: Max Speed

Speed setup

1~254: Speed increase

CH3

Ignition ON/OFF

0~253: Ignition OFF 254~255: Ignition ON

0 and 255: permanent fire (10s is limit duration time)

CH4

Firing Duration setup 1~254: 10~2540ms duration time

(Manual firing duration = DMX Value * 10ms)

CH5

Preset sequence setup 0-2: no preset sequence

3-255: preset sequence

DMX value = 2 + Sequence No.*2.55 (ROUND OFF)

0~49: Depressurize (Emergency Stop)

CH6

Mode setup

50~200: Pressurize

201~255: Depressurize (Emergency Stop)

Channel 1 (CH1): Manual Angle Setup

Angle No.

Angle

DMX Value

1

-105°

0

2

-90°

18

3

-75°

36

4

-60°

54

5

-45°

73

6

-30°

91

7

-15°

109

8

128

9

15°

146

10

30°

165

11

45°

183

12

60°

201

13

75°

219

14

90°

237

15

105°

255

1. The first channel controls the firing angle. It defines to which angle the nozzle of CIRCLE FLAMER move

to. The angle can be chosen anywhere between -105° to +105° (DMX value 0 to 255)

2. The DMX value for angle of 0° is 127.5 (round up 128). Use this value, following formula can be used
to calculate all other angles in degree. Please always note the prefix of the angle DMX Value = 127.5 + (*1.2145)

Channel 2 (CH2): Manual Nozzle Waving Speed Setup

CH2: Nozzle Waving Speed Setup

DMX Value

0

1-254

255

Speed

Max Speed

Incremental of Speed

Max Speed

The second channel defines the nozzle waving speed. It work together with Channel 1 for manual firing

Channel 3 (CH3): Ignition ON/OFF

CH3: Ignition

DMX Value

0-253

254-255

Ignition

Igniter disable (ignition OFF)

Igniter enable (ignition ON)

The third channel activates the actual ignition. If the DMX value of this channel higher than 253, the

CIRCLE FLAMER will ignite.

Channel 4 (CH4): Firing Duration setup

CH4: Manual Firing Duration setup

DMX Value

0

1

2

3

4

Firing Duration Permanent 10ms 20ms 30ms 40ms

The fourth channel is the firing duration setup

Below formula can be used to calculate the firing duration (ms): DMX Value = t/10

……

254 2540ms

255 Permanent

Channel 5 (CH5): Program Sequence setup

The fifth Channel allows to firing a preset sequence. Three DMX values can be used for one of the

programmed firing sequence from above sequence list (refer to above sequence list table).

Below formula can be used to calculate firing sequence: DMX Value = 2 + Sequence No.*2.55

CH5: Sequence List

DMX Value

0~2

3~5

6~7

8~10 11~12 ………. 225-226

Sequence No.

N/A

1

2

3

4

88

Channel 6 (CH6): Mode setup The sixth channel is the working mode of pump. When the safety lock located at TEST MODE, set DMX value between 50-200 to test the system. For safety, the device will not pressurize. When the safety lock located at USER MODE, the device pressurize activated by set DMX value between 50-200. The device can generate flames under Pressurize mode.

DMX Value Mode

0-49 Depressurize Mode

CH6: Mode setup 50-200
Pressurize Mode

201-255 Depressurize Mode

Control with SHOWVEN Host Controller ZK6200/ZK6300
If use SHOWVEN Host Controller ZK6200 or ZK6300 to program the CIRCLE FLAMER X-F3600, please set on Host Controller. The setting step is: Press “F3” on Host Controller ­ find “Device” ­ choose the right device “CIRCLE FLAMER”. Host Controller with bi-directional communication with device, please allocate a unique DMX address for each unit of CIRCLE FLAMER X-F3600. Press “Pre-heat” to start to pressurize CIRCLE FLAMER X-F3600. Firing the preset flame effect by enter the preset sequence No. to FIRING HEIGHT.

Start No. End No. Device Mode Selection Repeat Time Mode DMX IN DMX Address CAN Trigger Source Audio Level Audio Filter Delay

F3 CONFIG

:

1

:

10

: CIRCLE FLAMER

: User Mode

: Repeat Period Mode

: ON

:

1

: OFF

: HAND

: 2

: 100ms

F1 MAIN

Synchronizarion CIRCLE FLAMER No. 1-10

F I L E FIRING FIRING

NO. HEIGHT DURTN

1

31 0.5s

TRIG REPEAT REPEAT

DELAY DELAY COUNTS

0.0s

10.0s

1

Terminal Monitor

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

From 1-15 Steppsequence short 2.4s

MAIN

FILE SELECT

CONFIG

ABOUT

Operation
1. Safety Distance Definition and Instructions
Safety distance for CIRCLE FLAMER X-F1800 divided into two parts safety radius around machine (a) and safety distance at firing direction (b). No person and flammable materials are allowed to stay inside the safety isolation zone when flamer was armed. The safety radius around machine depends on the firing height (nozzle size). For safety distance at firing direction equals to maximum firing height * 1.5. CIRCLE FLAMER X-F1800 with maximum 105 waving firing angles, when firing step sequence, wave sequence or additional sequences the safety isolation zone is a three-dimensional sector area.

Nozzle Type
SFSMA027 Nozzle EL SFSMA024 Nozzle L SFSMA025 Nozzle M

Max. Flame Height
6m 8m 10m

Safety Radius around (a)
2m 2.5m 3m

Safety Distance at Firing Direction (b) 9m 12m 15m

The CIRCLE FLAMER X-F1800 safety isolation zone is a three-dimensional space with a cross-section of 210° sector enclosed by a and b (check below diagram). We can understand it as a safety area formed by a safety column with diameter of a, height of b rotate of ±105 degrees. Unauthorized persons and objects are strictly prohibited from entering. Depending on the firing sequence / angles the sector area changes accordingly. For angled installation, the safety distance both around machine and firing direction should shift accordingly.

Safety distance in windy environment
The safety isolation zone radius (a) increase with wind direction and wind speed (v, m/s). The safety distance in windy conditions can be calculated as below:
For Nozzle L: a = 2.5 + v;
For example when the wind speed is 3m/s, we use the Nozzle L, then the safety isolation zone radius should be 5.5m.
CAUTION: When the wind speed 8m/s (wind force 5), please use it with caution. When wind speed 17m/s
wind force 8 , please stop use flamer.

Direction Explanation
There is direction explanation on top panel of CIRCLE FLAMER X-F1800 as show above picture. 1. 1 to 15 is the firing angle of CIRCLE FLAMER X-F1800, Far Right is position 15, Middle is position 8,
Far Left is position 1. 2. Audience side and control side are indicated in above picture. Note: in order to indicate correct direction, please place the top panel correctly. Label of CIRCLE FLAMER X-F1800 The label is at rear panel of machine and information is show as below.
Fuels for CIRCLE FLAMER X-F1800 1. Water content in fuel should less than 0.5% 2. For maximum safety, please use fuel with flash point between 60-80, ISOPAR L is highly
recommended. 3. Ethanol is not suggested due to three reasons, first ethanol is highly flammable makes it not as safe as
ISOPAR; secondly the color of flame is very weak; thirdly there are always high water content (> 0.5%) in ethanol. 4. Colored fuels are forbidden to use on CIRCLE FLAMER X-F1800 it may damage the machine. SHOWVEN excludes liability for the losses, damages and accidents caused by not using qualified fuels in accordance with this requirement. Always have a dry powder fire extinguisher, a CO2 fire extinguisher and an extinguishing blanket next to the equipment in case of needed. And someone must be on duty during operation. In case accident occurs, a dry powder fire extinguisher can be used when the fire is large, and a carbon dioxide fire extinguisher can be used when the fire is small.

2. Install CIRCLE FLAMER X-F1800 a) Choose the correct nozzle, ensure the installation position of CIRCLE FLAMER X-F1800 meet above safe distance requirements. New CIRCLE FLAMER X-F1800 supplied with a nozzle M which generate up to 10m flame. b) Horizontal installation is preferred for CIRCLE FLAMER X-F1800. If need to install CIRCLE FLAMER XF1800 in angles, please turn the TIP Setting to OFF status first. X-F1800 with maximum tilt angle of 45° or -45°, and it can be angled to the direction as show in below picture. Besides please be aware the fuel level in fuel tank to avoid fuel leakage when tilt installation. c) Make sure CIRCLE FLAMER X-F1800 is securely installed. For truss installations always connect with safety rope to ensure extra safety. If there is any other national or regional guidelines please follow it accordingly.
3. Connect Power and DMX cable to CIRCLE FLAMER X-F1800 Before power and/or DMX cable connection, make sure safety lock of CIRCLE FLAMER X-F1800 stay at TEST MODE as above picture.
If control by DMX, follow below steps: a) Connect a power cable to the POWER IN socket of CIRCLE FLAMER X-F1800. Connect the other end of power cable to the power source. Make sure power supply in consistent with the rated voltage of the equipment, and the socket must well grounded. b) Each unit of CIRCLE FLAMER X-F1800 can be connected to power supply directly. If connect machine in sequence, please connect a power link cable to the POWER OUT of previous machine, connect the other end of the power link cable to POWER IN of the next machine. Do not connect exceed units to a single electrical circuit. c) Power on CIRCLE FLAMER X-F1800 d) Assign a DMX address for each unit of machine. If use SHOWVEN host controller or FXcommander to control the machine please allocate a unique DMX address for each unit of machine. e) Connect a DMX cable to the DMX IN socket of first unit of X-F1800, another head of this DMX cable connect to DMX console (such as FXcommander). Make sure the DMX console is powered off. f) Connect a DMX cable to the DMX OUT socket of previous X-F1800, and the other end to the DMX IN of next machine. Connect all devices in series in this way. g) Suggest to plug in a DMX terminator into the DMX OUT in last unit of machine to improve signal reliability. Signal amplifier is required for long distance (>200m) DMX signal transmission.

If control by 9-60V pyro signal, follow below steps: a) Connect a power cable to the POWER IN socket of CIRCLE FLAMER X-F1800. Connect the other end of power cable to the power source. Make sure power supply in consistent with the rated voltage of the equipment, and the socket must well grounded. b) Each unit of CIRCLE FLAMER X-F1800 can be connected to power supply directly. If connect machine in sequence, please connect a power link cable to the POWER OUT of previous machine, connect the other end of the power link cable to POWER IN of the next machine. Do not connect exceed units to a single electrical circuit. c) Connect the power control cables to the 9-60V pyro signal connector on CIRCLE FLAMER X-F1800. d) Connect the other end of power control cables to the pyro controller (9-60V external trigger source). Make sure the pyro controller is powered off e) Power on all CIRCLE FLAMER X-F1800 f) Set the Ext Ignite to ON status in advanced interface, set the firing sequence by choose a sequence No. at Set Ext Sequence.
4. Power ON the DMX console or pyro controller
5. Programming Program the CIRCLE FLAMER X-F1800 with DMX console.
6. Test the ignition function of CIRCLE FLAMER X-F1800 Test the ignition function of CIRCLE FLAMER X-F1800, we can check whether the igniters of each unit of X-F1800 is working fine. Due to the safety switch is stay at TEST MODE the pump won’t work, there will be only ignition while no fuel spray out, so no flames generated.
7. Fill the CIRCLE FLAMER X-F1800 Please fill the machine with qualified fuel. The fuels suggested on CIRCLE FLAMER are ISOPAR, ISOPROPANOL, please make sure water content in fuel should less than 0.5%.
8. Firing a) Double confirm the prescribed safety isolation zone is clear, no person, animal or other property within this region. b) Switch the safety switch of CIRCLE FLAMER X-F1800 to USER MODE.
c) Pressurize CIRCLE FLAMER X-F1800. d) Firing, the operator should always have a clear view of the device, so that he/she can stop the show
immediately when there is danger.
9. Depressurize Depressurize all CIRCLE FLAMER after use or if not use for a long time during the show we also suggest to depressurize to ensure the safety.
10. Power OFF a) Power OFF DMX console b) Switch safety switch of CIRCLE FLAMER X-F1800 to TEST MODE c) Power OFF CIRCLE FLAMER X-F1800 d) Unplug power cable, DMX cable.

Nozzles and Nozzle Replacement
Nozzles and Flame Height
Nozzle M: (standard configuration) Short flame: 5-7m, Long flame: 8-10m. Nozzle L: Short flame: 3-5m, Long flame: 6-8m. Nozzle EL: Short flame: 3-4m, Long flame: 4-6m. Nozzle Replacement Wrench Use 14mm outer hexagon socket wrench to disassemble the nozzle, clean the nozzle and nozzle socket with air gun (air compressor), change a different nozzle and install it.
Nozzle Installation available in new design Please assemble the stailess steel gasket(RMSMA530), O ring and nozzle main part according to below picture. The O ring should be inside the stailess steel gasket, otherwise it may leads to fuel leakage. Use nozzle replacement tool outer hexagon socket wrench to tighten the nozzle.

Igniter Position Adjustment
Whenever changed the nozzle or ignition is not good, please check igniter pole position according to below parameters. Check the ignition success rate after adjustment by firing.

Nozzle

a (mm)

M

L

16±1

EL

WARNING: Do unplug the power cable when service flamer.

b (mm) 4±0.5

Waterproof cover installation
Hang the waterproof cover on the rear panel side of the top cover and fix it with 2pcs of M5*10 screws as shown in below picture.

Battery Recommendation
CIRCLE FLAMER can be driven by battery, for use of Battery power supply: CIRCLE FLAMER X-F1800 with stable internal circuit design, please support X-F1800 with battery voltage higher than 12V. The driving speed of motor won’t change because of the decrease of battery power supply. Battery options: 12V lead-acid battery (above 30AH, with more than 24h standby). For Lithium battery, please use battery with output above 30A. Socket type: NEUTRIK-NL4FX, 4 pin audio connector (1+ connect 12V anode, 1- connect 12V cathode). Connecting power cables should above 14AWG.

Maintenance
1. To maintain the system in good performance and running status, it is recommended to running the device at least once per month.
2. Check the ignition probes both before and after each show, if there is any foreign objects on it please clean it up.
3. Maintenance of the nozzle: Nozzle needs to be cleaned from time to time, and it is recommended that once every six months (depending on the environment and frequency of use). In the process of using the equipment, if the flame shape is seriously deformed or the fuel injection line is significantly deformed or coarsened, the nozzle should be removed immediately for cleaning. If after clean, there are still problems please replace new nozzle.
4. Maintenance of the O-ring: If it is found that the O-ring of the nozzle is damaged or ageing when cleaning the nozzle, the O-ring should be replaced in time (material and size of O-ring: fluororubber Oring, the outermost diameter is 14 mm, and the line diameter is 2 mm).

5. Switchable power input design, switchable between 110V and 220V as show above picture (voltage will show on it). The power supply is located on the side of the electric control, and you should remove the cover before switch it.

Optional Parts for CIRCLE FLAMER X-F1800

Part. No.

Description

RMWAS025 RMBOT036 RMEMD062 SFSMA025 SFSMA024 SFSMA027 RMSMA530 SFMET944 RMSMA215 RMSTE472 RMSTE473 SFMET455

Fluorine O ring, outer 14, wire diameter is 2 mm Safety ring
Wireless receiver ( for wireless control with FXcommander) nozzle M nozzle L nozzle EL
SS304 gasket, outer 18, inner 14, thickness 1.5mm Nozzle disassemble tool
Angle block assembly
Waterproof cover for control panel

pcs / unit 1 1 1 1 1 1 1 1 2 1 1 1

Warranty Instructions
Sincere thanks for your choosing our products, you will receive quality service from us The product warranty period is one year. If there are any quality problems within 7 days after shipping
out from our factory, we can exchange a brand new same model machine for you We will offer free of charge maintenance service for machines which with hardware malfunction
(except for the instrument damage caused by human factors) in warranty period. Please don’t repair machine without factory permission Below situations NOT included in warranty service: Damage caused by use unqualified fuels; Damage caused by improper transportation, usage, management, and maintenance, or
damage caused by human factors; Disassemble, modify or repair products without permission; Damage caused by external reasons (lightning strike, power supply etc.) Damage caused by improper installation or use;
For product damage not included in warranty range, we can provide paid service. Invoice is necessary when applying for maintenance service from SHOWVEN