BT91 Showven Spark Fountain Machine User Manual
- September 17, 2024
- Showven
Table of Contents
- BT91 Showven Spark Fountain Machine
- Safety Instructions
- Safety Distance
- Description
- Technical Specifications
- Structure of SPRKULAR® JET
- Diagram of Bottom Panel
- Operation Panel
- Interface
- Operation Guide
- Maintenance
- Warranty Instructions
- Frequently Asked Questions (FAQ)
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
BT91 Showven Spark Fountain Machine
USER MANUAL
Showven Technologies Co., Ltd.
Thanks for choosing SPARKULAR® JET, we wish it will sparks up your show. Please read the following manual carefully before operating this product.
Safety Instructions
- Unauthorized repair are prohibited, it may cause serious incident.
- SPARKULAR® JET can be used in rain, but after use please clean it, and store it at dry environment. \ Make sure lid of feeding hopper are well covered when use SPARKULAR® JET.
- Accidentally burning of consumable can only use sands to extinguish.
- Consumable should keep away from moisture and stored in a dry sealed environment.
- Check whether there is consumable aggregate in the output nozzle both before and after each show, if any, please clean it up, or it will affect the firing effect or even damage SPARKULAR® JET.
- Please be noted that there may sparks or remains fall to the ground. Make sure there is no flammable objects such as carpet on the ground within the safety radius around machine.
- Maximum cascade of SPARKULAR® JET is 6 units (BT91) / 3 units (BT92) with a standard power cable.
- Exceed connecting may result in damage or even cause fire.
- For better heat dissipation, block the air intake and air outlet is prohibited.
- Cover the output nozzle of SPARKULAR® JET is forbidden, inspect the machine before each show,making sure no objects or material will block the output nozzle.
- Never touch the nozzle of SPARKULAR® JET, danger of getting burnt
- Never touch the sparks which shooting out from the nozzle
- Ensure that children, animals and unauthorized persons don’t have access to the SPARKULAR® JET.
Safety Distance
- Keep audience and flammable material at a minimum distance of 1.5m (when use HC8200 SMALL) or 3m (when use HC8200 MEDIUM or LARGE) from SPARKULAR® JET.
- Make sure sparks shoot out from SPARKULAR® JET can NOT touch any objects. And keep a clearance with minimum 2m from the setting maximum effect height.
- In windy environment, increase the safety distance according to the wind direction and speed. \ The safety zone area shifts accordingly when machine use angled extension tube. Please increase the safety distance in the angled direction.
- Sparks and consumables from the machine can lead to serious eye injury. Always wear safety goggles when enter the safety zone.
Description
SPARKULAR® JET is another brand new effect originally invented by SHOWVEN® . It generates a flashing SPARKULAR® effect up to 10m. Built-in automatic air compressor, no external pressure tank needed, makes it easier for setup and fewer usage restrictions. It is perfect effects solution for stadium, concerts etc. medium to large events.
Technical Specifications
- Model: BT91 / BT92
- Dimension: 320 280 300mm
- Weight: 16.5kg
- Housing material: 304 Stainless steel
- Input: AC 100V-120V,50/60Hz, Max.cascade:3PCS AC 200V-240V,50/60Hz, Max.cascade:6PCS
- Work power: 350W
- Work Temp.: -10 ~50
- Effect height: HC8200 LARGE(8-10m) / HC8200 MEDIUM(6-8m) / SMALL(4-5m)
- Hopper capacity: 450g
- Trigger delay: 0.6-1s
- HC8200 consumption: HC8200 LARGE/MEDIUM 10-15g/shot; HC8200 SMALL 4-6g/shot \ Interface: 3-pin and 5-pin DMX IN/OUT, NEUTRIK POWERCON TURE 1
- Control: Standard DMX 2 Channels
Structure of SPRKULAR® JET
1. Extension Tube
2. Feeding Hopper
3. LCD screen
4. Safety Loop
5. Power Switch
6. Fuse
7. 5-PIN DMX IN
8. 5-PIN DMX OUT
9. 3-PIN DMX IN
10. 3-PIN DMX OUT
11. POWER IN
12. POWER OUT
Diagram of Bottom Panel
Operation Panel
1. LED display area
READY: Green light flashing means heating up. Turns from flashing into long on, indicates that the machine is ready to work
DMX: Flashing shows that DMX signal is connected, light OFF means there is no DMX signal FAULT: Light ON when error occurs
HEAT: Light ON when system is heating up
2. Control button area
MENU: Press to switch through menu, press and hold for 3s enter advanced menu DOWN: Parameter down
UP: Parameter up
ENTER: Confirm and save parameters
3. RFID area
Composite Ti with RFID card, swiping cards used to identify parameters and types of granules. The RFID card is disposable, one card can only use one time.
Interface
First Line: DMX: DMX address P: pressure value
Second Line: T: inner core temp. Delay: firing trigger delay
The working principle of the machine is when the firing is triggered, it takes some time (jet delay) for the system to transfer and stimulate the consumables. When it reached the firing trigger delay time, the valve will open automatically and firing.
2. Error information
Error information | Explanation |
---|---|
E0 System IC | 1. Emergency stop was executed when firing was triggered, and |
firing stops. E0 disappear automatically 1min later
2. Too frequent firing in a short period of time, E0 disappear 100s later
E1 Pump Protect| It happens when continuous pressurization fail, probably the
pump broken
E2 Temp. Sensor| Temperature sensor is not connected or damage
E3 P Temp. Over| Chassis over-temperature
E4 Time Remain| Activated time for machine is not enough, need to swiping RFID
card
E5 K Temp. Over| Heating chamber over-temperature
E6 Heat Fail| Heating fail, if recover automatically, please pay attention to
the power supply
3. Setting Menu
Press “MENU” switch through setup menu.
Options | Range | Default | Explanation |
---|---|---|---|
Set DMX Address | 1-511 | 1 | Set DMX address. Each machine occupy two |
DMX channels. If controlled by Host Controller, please assign a unique address
for each machine
Material Select| Large/Medium/Small| Large| Please select based on the
consumable you use
Manual Clear| On/Off| OFF| Clear material manually. Please be careful, do NOT
close to the nozzle.
4. Advanced Menu:
Press “MENU” switch through setup menu.
Options | Range | Default | Explanation |
---|---|---|---|
Set Temperature | 480-620 | 580 | Set inner core temp |
Auto Heat | On/Off | OFF | ON: machine will heating up and pressurize |
automatically when power on machine
OFF: Need to manually turn on heating up and
pressurize on DMX console
Mode Selection| Factory Mode/ User
Mode| User Mode| Factory mode is for engineer only. When in Factory mode
machine can’t controlled by DMX console/host
controller
Standby Switch| On/Off| OFF| Standby function. When ON, the machine can firing
only when heating up was finished
Ext. Ignite| On/Off| OFF| When use fireworks firing system to firing the
machine. Customized design for fireworks customer
Feeding Test| On/Off| | Test the feeding structure and feeding motor
Fan Test| On/Off| | Test the blowing fan
Tip Over Error| ON/OFF| ON| Tilt function switch
*Please don’t change default value without engineer’s suggestion from SHOWVEN®
5. DMX Control
SPARKULAR® JET occupy 2 channels.
First channel | Function |
---|---|
0-111 | Firing OFF |
112-255 | Firing. To avoid false triggering, trigger time should maintain above |
0.2s.
Second channel| Function
60-80| Clear material, the valve will open when clear material, and clear the
consumable remains in the heating chamber. DO remember to clear
material after each show.
20-40| Emergency stop, when firing was triggered, operator can stop the firing
during this jet delay period. And machine will prompt E0 error
0-10| Pre-heat OFF and auto pressurize OFF (disabled when auto-heat ON)
240-255| Pre-heat ON and auto pressurize ON (disabled when auto-heat ON)
Operation Guide
1. Install SPARKULAR® JET
a) SPARKULAR® JET can only installed horizontally. If need to firinng
SPARKULAR® JET in angles, please use angled extension tube.
b) Make sure the machine is securely installed to avoid tipping.
c) Check carefully the output nozzle and extension tube of each machine, make
sure the output nozzle and extension tube are in good shape and there is no
powder aggregate.
d) Install the extension tube if use HC8200 MEDIUM and HC8200 LARGE. When use
HC8200 SMALL there is no need to install extension tube.
e) Beside the standard straight extension tube, there are other two angled
extension tubes optional: 30° angled extension tube and 45° angled extension
tube.
f) Be aware that there will be sparks drop on ground when use angled extension
tube.
g) Safety distance should shift accordingly when use angled extension tube.
2. Fill SPARKULAR® JET
a) Open powder bags and fill the feeding hopper. Hopper capacity of SPARKULAR®
JET is 450g.
b) Make sure the powder is originally from SHOWVEN or SHOWVEN authorized
distributor, other types of powder may block even damage the machine.
c) Choose correct consumable according to the application scenario. SPARKULAR®
JET can only use HC8200 LARGE, MEDIUM and SMALL.
d) Please be noted that there may sparks or remains fall to the ground. Make
sure no flammable material on ground in the safety zone.
e) Maximum effect height: HC8200 LARGE is 10m, HC8200 MEDIUM is 8m, HC8200
SMALL is 5m.
f) Make sure the lid of hopper is locked tight after filling.
3. Connect Power / DMX cable
a) Connect a power cable to the POWER IN socket of SPARKULAR® JET. Connect the
other end of power cable to the power source. Make sure power supply in
consistent with the rated voltage of the equipment, and the socket must well
grounded.
b) If connect machine in sequence, please connect a power link cable to the
POWER OUT of previous machine, connect the other end of the power link cable
to the POWER IN of next machine.
c) The SPARKULAR® JET power supply cable maximum allowed cascade is 6 units
(BT91) / 3 units (BT92). Do not connect exceed units to a single electrical
circuit.
d) Power ON all SPARKULAR® JET.
e) Assign DMX address for each unit of SPARKULAR® JET. If use SHOWVEN host
controller or FXcommander to control the machine please allocate a unique DMX
address for each unit of machine.
f) Connect a DMX cable to the DMX IN socket of first unit of SPARKULAR® JET,
connect the male connector end of DMX cable to your DMX controller
(FXcommander, HOST CONTROLLER, light console etc).
g) Connect a DMX cable to the DMX OUT of previous machine, and the other end
of to the DMX IN of next machine. Connect all devices in series in this way.
h) Suggest to plug in a DMX terminator into the DMX OUT in last unit of
machine to improve signal reliability. Signal amplifier is required for long
distance (>200m) DMX signal transmission.
4. Activate SPARKULAR® JET by swipe RFID card
a) Swipe an RFID card. Read the card as show below. SPARKULAR® JET screen
flash once if read successfully.
b) SPARKULAR® JET will report E4 when remaining firing times is less than
10times.
c) Please note each RFID card come with 200g package HC8200 can increase
single machine 30 firing times, the maximum recharge times each time for
SPARKULAR® JET is 120 times, when remaining firing times reached 120, it can’t
recharge anymore RFID card.
5. Programming and Firing
a) Programming SPARKULAR® JET, set the “Material Select” in the menu according
to the consumable (HC8200 LARGE / MEDIUM / SMALL) you use.
b) Heating up and pressurize the machine, it takes around 8min.
c) Make sure the prescribed safety zone is clear.
d) Suggest to clear material before firing.
e) Firing. Between each firing there is a firing interval which is for the
pressure recovery of the built in pressure tank.
f) The operator should always have a clear view of the device, so that he/she
can stop the show immediately when there is danger.
g) Clear material for SPARKULAR® JET after show, clear material will remove
the remaining particles from heating chamber.
6. Turn off and clean up
a) Power off SPARKULAR® JET, allow SPARKULAR® JET to cool down.
b) Disconnect all POWER and DMX cables.
c) Empty the remaining HC8200 in hopper, and store the remaining HC8200 in a
dry sealed bottle for next time use. Never touch the output nozzle of
SPARKULAR® JET when empty the hopper. DANGER OF GET BURNT!
d) Operators can use handheld vacuum cleaner to empty the feeding hopper. Do
make sure the machine was cool down when clean it. Do NOT use high-power
vacuum cleaners to avoid hot consumables being sucked into the vacuum cleaner
from the heating chamber and cause fire.
e) Clean the surroundings to remove powder residues.
Maintenance
a) Empty the feeding hopper before shipment of machine.
b) Empty the feeding hopper if long time not use, for high humidity
environment we suggest to empty feeding hopper after each show.
c) Clear material both before and after the show.
Warranty Instructions
Sincere thanks for your choosing our products, you will receive quality
service from us
The product warranty period is one year. If there are any quality problems
within 7 days after shipping out from our factory, we can exchange a brand new
same model machine for you
We will offer free of charge maintenance service for machines which with hardware malfunction (except for the instrument damage caused by human factors) in warranty period. Please don’t repair machine without factory permission
Below situations NOT included in warranty service:
- Damage caused by use other type of consumable which is not originally from SHOWVEN® . \ Damage caused by improper transportation, usage, management, and maintenance, or damage caused by human factors;
- Disassemble, modify or repair products without permission;
- Damage caused by external reasons (lightning strike, power supply etc.)
- Damage caused by improper installation or use;
For product damage not included in warranty range, we can provide paid service.
Invoice is necessary when applying for maintenance service from SHOWVEN® .
SHOWVEN
Showven Technologies Co., Ltd.
Tel: +86-731-83833068
Web: www.showven.cn E-mail: info@showven.cn
Add: No.1 Tengda Road, Liuyang Economic & Technical Development Zone,
Changsha, Hunan, 410300, P.R.China
Frequently Asked Questions (FAQ)
Q: What should I do if the machine displays an E0 error?
A: The E0 error indicates that an emergency stop was executed when firing was triggered. It will disappear automatically after a minute or 100 seconds if there are too frequent firings. Ensure proper operation and wait for the error to clear.
Q: How do I identify parameters and types of granules using the RFID
card?
A: Swipe the RFID card on the machine’s RFID area. Each RFID card is disposable and can only be used once to identify parameters and types of granules.
Q: What is the recommended safety distance for audience and flammable
materials?
A: Keep the audience and flammable material at a minimum distance of 1.5m. Adjust this distance accordingly based on wind conditions and the use of angled extension tubes.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>