Product Specifications:
- Model: DT-P300XX (PJ) (SJ)
- Output: 630 W
- Input:
- Rate Voltage:
- Frequency:
- Pressure switch:
- Jet type: Single jet
- Suction lift: 18-30 m
- Pump:
- Discharge head:
- Discharge capacity:
- Suction pipe: 1 1/4 inches
- Pressure pipe: 1 inch
- Discharge pipe: 1 inch
- Well diameter: 2 inches (50 mm)
Product Usage Instructions
Safety Precautions:
- Always remove the plug or turn off the switch immediately to prevent accidents.
- Avoid using wet hands when plugging or unplugging the device.
- Ensure proper grounding to prevent electric shocks or fires.
- If the power cord is damaged, contact a qualified professional for replacement.
Installation Guidelines:
- Have the pump installed by a distributor to ensure proper setup.
- Check for water leakage during installation and maintenance.
- Choose a location protected from rain and direct sunlight for installation.
- Select a place that allows easy access for inspection and servicing.
Installation Steps (Single Jet):
- Install the pump in a well with a diameter of 2 inches (50 mm).
- Follow the provided instructions for connecting suction and pressure pipes.
- Securely attach the hopper cap and control valve’s adjusting screw.
Maintenance Tips:
- Wear gloves while performing maintenance tasks.
- Regularly check for proper venting to prevent overheating and potential damage.
Cleaning and Troubleshooting:
- Avoid using the pump with faulty wiring to prevent fire or electric shock hazards.
- Contact the distributor for any abnormal pump behavior or malfunctions.
Frequently Asked Questions (FAQ):
-
Q: What should I do if the pump does not work properly?
A: In case of abnormal pump operation, immediately contact the distributor for inspection and repair. -
Q: Can I install the pump myself?
A: It is recommended to have the pump installed by a distributor to ensure proper setup and safety measures are followed. -
Q: How often should I check for water leakage?
A: Regularly inspect the installation area for any signs of water leakage to prevent damage and malfunctions.
Thank you for choosing to use the HITACHI pump and supporting the various products of the company. Please read and understand the manual before using the pump. Please keep this manual after reading it along with the warranty card as reference.
- In the installation of the pump it is necessary to implement it suitsbly, so the buyer should ask the distributor to install it.
- Should you want to know the name of the pump model, please read it from the nameplate on the body or the case.
PRECAUTIONS ON SAFE USE
Before using, please try to understand [the precautions on the safe use] carefully and use the pump correctly.
The precautions are shown as follows.
The level of damage and wear that may occur from abuse or ignorance of the
warnings is shown in the table as follows.
Warning
Content in the symbol means [The danger may result in severe injury or death]
Precaution
Content in the symbol means (The danger may cause damage to assets or injury)
Examples of the symbols
The content shows [warning or precaution] The content shows prohibitions
[Do not do it] The content shows a necessity that must always be done
[Explanation]
WARNING
Do not disassemble, repair or modify the unit unless you are a professional
serviceman.
- Do not disassemble, This may result in fire, malfunction or personal injury.
Do not touch with wet hands
While repairing you must take off the plug or cut off the electricity, and do
not use wet hands to plug in or remove the plug out.
- It may cause a short circuit.
Grounding Leakage Circuit Breaker You must always ground the appliance, and install a Leakage Circuit Breaker specifically fot it.
- If there is a defect or electric leak, it may cause a short circuit. For installation of an earth wire, please consult the distributor.
Prohibition Do not use the pump while its cover is removed.
It may cause a short circuit or fire from dust or degenerated insulation.
WARNING
Cleaning
Twimsalwan In case there is dust on the plug blades or surface, please clean
it.
- If not, it may cause a fire.
Wiring
Wiring should be made with correctness and safety according to the internal
requirements on technical standards for electrical appliances.
- Faulty wiring may cause a short circuit or fire.
Repairing
One should remove the plug out or turn off the switch immediately to prevent
an accident. In case the pump works abnormally or does not work, call the
distributor for inspection and repair.
- There is a risk of fire, short-circuit, power leak, and electric shock.
Do not roll, close, pull, bend, or modify the power cord or cause a mark or damage on it. Do not put heavy things on it, clip, or modify the cord.
- The power cord may be damaged and cause a short circuit.
PRECAUTIONS
Power Supply
In the event of not using it for a long time, remove the plug out of the
outlet or turn off the switch.
- If not, it may cause a fire from a electric leak or short circuit due to degenerated insulation.
Do not place objects on the pump.
- It may cause the pump is damaged.
While removing the plug, pull the plug body.
- If not, it may cause a electric shock.
Do not place flammable materials inside the pump cover, and do not cover the pump with any material.
-
The pump will overheat, due to inability to vent which may result in fire or pump damage.
-
If the power cord is damaged, it must be replaced by the distributor agent or similarly qualified persons in order to avoid a danger.
The appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
- Children should be supervised to ensure that they do not play with the appliance.
PRECAUTIONS
Prohibition
Do not touch the pump motor while the pump is running.
- Due to the high temperature, it may cause a scald
Caution
While performing maintenance, should wear the gloves during working.
- To prevent possible injury.
Check whether the flooring offers effective leakage prevention and drainage.
- Otherwise, in the case of a water leak, it may cause damage to the pump.
When the pump is installed, please check that no water leakage occurs.
Run Do not dry run it.
- The water left in the pump may overheat and cause the parts damage.
Do not use the pump with other liquids such as oil, thinner or hot water at 40°C or more-
- Otherwise, it may cause injury or a short circuit.
- Components of the pump. such as plastic, rubber parts, can be damaged.
Check the installation area.
- Avoid sites that are easily flooded, as it may cause damage to the pump.
PART NAMES AND STRUCTURE
MODEL : DT-P300XX
-
No internet connection, or can not reach OCR server
-
Otherwise, it may cause injury or a short circuit.
-
Components of the pump. such as plastic, rubber parts, can be damaged.
Check the installation area.
- Avoid sites that are easily flooded, as it may cause damage to the pump.
PART NAMES AND STRUCTURE
MODEL : DT-P300XX
Modification pressure switch may cause malfunction of machine and pump parts damage. The warranty will be terminated instantly if you modify pressure switch.
Single Jet
Parallel let
Remove the paper inside the cover after finishing installaiton.
How to Prime it
- After installation on the first run, open the hopper cap and fill on some water,
- Do not expose to water the electric components such as motor, electronic parts, etc.
- For new pump, water must be filled into the suction pipe, compression pipe, and pump head and securely close the hopper cap.
- Open the water tap at the supply side.
- Install the pressure gauge at the hopper cap.
- Close the control valve fully by turning it clockwise, and connect the power cord to turn on the pump.
- Adjusting screw after the water flows into the pump, adjust the control valve by releasing the adjusting screw.
- Adjusting screw 1-2 ou After closing the water tap, check all conditions by opening or closing other water taps. If there is a noise, adjust the adjusting screw by turning it 1-2 times.
Adjusting Pressure
100kPa (1.0kgf / cm2)
SPECIFICATIONS
PRECAUTIONS BEFORE INSTALLATION
Check the installation site to make sure that it has good drainage.
-
If water leakage, it can result in serious damage.
-
Should be installed in a place that is protected from rain or direct sunlight.
Check the installation Location.
- Choose the place that can easily be checked or serviced.
- It should be installed near the well as much as possible
How to install the single jet
For the single jet installation, install it to the well with diameter of 2 inches (50 mm.).
Perfer the installation as follows:
How to install
- Prepare all parts to install such as 1-inch PVC pipes, and joints (refer to the specified depth in the manual).
- Expand the end of the provided 1-inch PVC pipe (suction pipe) about 50 mm by holding it over the fire as shown in the figure of step 1.
- Install the expanded end of the PVC pipe to the venturi of the single jet. Install the end of PVC pipe so that it is over the venturi about 10 mm as shown in the figure of step 2. Then, cover the connection point with a damp cloth and bend the pipe’s end onto the venturi as shown in the figure of step 3.
- Apply the silicone to protect the water leakage. Then, check for leakage at the silicone-applied point by pouring the water into the pipe.
- Connect the 1-inch PVC pipe to the single jet as shown in the figure of step 3. Securely attach them with Connect the 1-inch PVC pipe to the single jet as shown in the figure of step 3. Securely attach them with adhesive to avoid leakage. Then, insert the completed single jet into the wall in depth steps as specified in the manual.
- Tum the pipe’s end of the single jet (clockwise) until the sealing is against with the wall of the 2-inche well as shown in the figure of step 4.
- Connect the 1 1/4-inch PVC pipe to the adapter.
- Connect the 1 1/4-inch reducer to the pipe’s end of the single jet as shown in the figure of step 5.
- Install the flange set to the pump and connect them to the adapter (indicated in the circle) as shown in the figure of step 6.
- After inishing installation, refer to How to Prime it )
load wrote recrost on our dolle trole If you cannot install it yourself,
please consult the authorized personnel or your dealer.
All joints must be glued to avoid water leakage; otherwise, the pump is unable
to suck up the water.
How to install the parallel jet
How to install the parallel jet
For the parallel jet installation, install it to the wall with diameter of 4 inches (100 mm) or more. Perform the installation as follows:
How to install
- Prepare all parts to install such as 1-inch PVC pipes, 1 1/4-inch PVC pipes, and joints (refer to the specified depth in the manual).
- Connect the provided parallel jet to the 1-inch PVC pipe and the 1 1/4-inch PVC pipe at the suction side and pressure side of the jet respectively as shown in the figure of step 1.
- Connect the PVC pipes at the suction side and pressure side at the depth specified in the manual.
- Secure the PVC pipes at the suction side and pressure side together with the pipe band at every 5 m as shown in the figure of step 2.
- Secure the PVC pipes at the suction side and pressure side with the pipe holder at the well’s edge as shown in the figure of step 2.
- Place the pump to locate the position for installing the flange at the suction side and pressure side as shown in the figure of step 2.
- After finishing installation, refer to How to Prime it (page 5).
All joints must be glued to avoid water leakage; otherwise, the pump is unable
to suck up the water.
If you cannot install it yourself, please consult the authorized personnel or
your dealer.
INSTALLATION ROUTING THE HARNESS WARNING
Wiring should be considered a safety priority and comply with the technical
standard of the electrical appliance or internal wiring. Faulty wiring may
cause a fire or electric shock.
Lage Circuit Breaker Please connect the ground wire and install a leakage
circuit breaker.
WARNING
You must connect a ground wire and install a leakage circuit breaker
specifically for this job.
- You may have an electric shock when the pump is malfunction or leakage current. Lekge Circuit Breaker
Install the ground wire to prevent accidents from electric shock when electrical leakage occurs. Grounding and leakage circuit breaker require installation by an electrician specialist. The plug cord must be disconnected from the electrical outlet first and then installed.
Precautions Do not install the ground wire in the following places. (It is legal prohibition)
-
Where there is a gas pipe, telephone line, lightning rod and plumbing.
-
Leakage Curcuit Breaker
Installing Leakage Circiut Breaker age Ciuit Breaker Tenseustnihuge 15 mA- Please install a Leakage Curcuit Breaker with the working current less than 15mA. 2 kg
- In the case where there ia an existing Leakage Curcuit Breaker, check as specified above.
PROBLEMS AND REPAIRS
When there is a problem during usage, you should stop the pump, remove the plug, and check to find the cause or consult your distributor.
DT-P300XX
MANUFACTURER : Hitachi Consumer Products (Thailand), Ltd.
ADDRESS : Kabinburi Factory 610/1 Moo 9 Tambol Nongki, Amphur Kabinburi,
Prachinburi, Thailand 25110
Tel. 0-3728-4000 ( 19 Line) Fax: 0-3728-4161
DISTRIBUTOR: TOYOBO (THAILAND) CO., LTD.
ADDRESS : 944 Mitrtown Office Tower, 11th Floor room 1103-1106, Rama 4
road, Wangmai, Pathumwan, Bangkok 10330
- Tel. 02-7663942-48 Fax: 02-1082677
- e-mail: pump@toyobo.co.th
- SELLING PRICE : DT – P300XX (SJ) 12,500. – : DT – P300XX (PJ) 9,900. –
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>