ABOUT THIS MANUAL

Purpose
This manual describes the introduction, installation, operation and emergency situations of the battery bank. Please read this manual carefully before installations and operations. Keep this manual for future reference.

Scope
This manual provides safety and installation guidelines as well as information on tools and wiring.

Safety Instructions

WARNING: This chapter contains important safety and operating instructions. Read and keep this ll,j manual for future reference.

  1. Before using the unit, read all instructions and cautionary markings on the unit, the batteries and all appropriate sections of this manual.
  2. CAUTION — To reduce risk of injury,damage,even burst. please use ii following using manual. In case of causing personal
  3. Do not disassemble the battery. Take it to a qualified service center when service or repair is required. Incorrect re-assembly may result in a risk of fire.
  4. To reduce risk of electric shock, disconnect all wirings before attempting any maintenance or cleaning. Turning off the unit will not reduce this risk.
  5. CAUTION – Only qualified personnel can install this device with inverter.
  6. For optimum operation of this battery, please follow required spec to select appropriate cable size.
  7. Be very cautious when working with metal tools on or around batteries. A potential risk exists to drop a tool to spark or short circuit batteries or other electrical parts and could cause an explosion or fire.
  8. Please strictly follow installation procedure.
  9. To support full output load, at least 2 sets of FLA48V for inverter larger than 6KVA in parallel connection.
  10. GROUNDING INSTRUCTIONS – This System should be connected to a permanent grounded wiring system. Be sure to comply with local requirements.
  11. NEVER cause AC output and DC input short circuited. Do not connect to the mains when DC input short circuits.
  12. Warning!! Only qualified service persons are able to service this device.
  13. Battery should be installed indoor and kept away from water, high temperature mechanical force and flames.
  14. Do not install the battery in any environment of temperature below 0°C orover55°C,and humidity over BO%.
  15. Do not put any heavy objects on the battery.

Can be connected in parallel

  1. The batteries can be connected in parallel. Series connection is not allowed. Use in upright position only.
  2. The batteries are not allowed to connected with PWM controller for charging.

Special Attention : Due to the built-in protection board of the lithium battery pack is with over-discharge protection function, it is strongly recommended to stop using the load when the battery pack is over-discharged. The battery pack cannot be repeatedly activated for discharge. Or the battery may be failed to be activated by the AC or PV activation cable ( It requires a special charging activation method), so cannot be charged. Therefore, when the battery pack is low power, please charge the battery as soon as possible when main power or solar energy is available.

INTRODUCTION

The battery system main using solar power system for family house. II also have a with to controller the battery easily and protect our Household application timely.

Features

  • LiFePO4: Higher safe performance and longer cycle life.
  • Multiple Protection: Built-in smart BMS and Breaker.
  • Flexible Installation: Wall-Mounted or Floor-Mounted.
  • Wide Compatibility: Compatible with leading inverter brands.
  • High Scalability: Capacity up to 187.5kWh.
  • Long Warranty: 7 Years.

 Product Overview

Code Name
A LCD  display
B Breaker
C Power On/Charging indicator
D Fuse
E Earth wire
F Battery Positive +
G Switch
H Communication port
  Battery Negative –

Specifications

Model FLA48250
Capacity 12.5kWh
Battery Type LiFePO4
Nominal Voltage 51.2V
Operating Voltage 44.8-57.6V
Recommend Charge/Discharge Current[1] s 150A
Recommend Charge/Discharge Power[1] s 7,500W
Maximum Charge/Discharge Current(15s) 200A
Maximum Charge/DischargePower(15s) 10,000W
Depth of Discharge(DOD) 95%
Scalability Up to 15 units in parallel
Communication RS485/CAN
Protection Level IP21
Cycle Life[2] 6000 Cycles
Charging Temperature Range 0-55°C
Discharging Temperature Range -20-55 °C
Display LCD+LED
Installation Wall-Mounted/ Floor-Mounted
Protection Built-in smart BMS, Fuse
Warranty 7 years
Net Weight 97kg
Gross Weight 118kg
Product Dimension 783x450x274mm
Package Dimension 900x570x450mm

[1] Recommend charge/discharge currenVpower is affected by temperature and SOC.
[2] Test conditions: 0.2C Charging/Discharging @25°C , 80% DOD.

Recommended Settings
Lithium battery pack is not same as lead-acid battery, so for the devices which you connect with the battery pack for charging or discharging, such as inverters, MPPT charger controllers or UPS, please implement pre-settings as recommended settings as below before you launched them.

Setting FLA48250
Max. Charging Voltage 57.6V
Floating charging Voltage

57.6V

Max. Charging Current| 150A•N
Cut-off voltage| 48V

Notes: “N” means the number of battery packs connected in parallel.

Installation Procedure

Setup Script

Using wall mounted components, first fix the wall mounted components to the wall, and then lift the machine onto the wall mounted components to secure it

Note:Do not use wall mounted components, place the chassis against the wall and secure it with fixing components

Tools

Floor Installation with Base
Installation Location Requirements

Installation Environment

Battery system switch operation

Power on battery system:
Turn the breaker to the “ON” state, press the POWER button 1 seconds, wait for the battery system LED light to light up, indicating that the boot is complete.

Power off battery system:
Turn the breaker to the “OFF” state, turn off the entire battery system.

INSTALLATION

Unpacking and Inspection
Before installation, please inspect the unit. Be sure that nothing inside the package is damaged. You should have received the following items inside of package.

Mounting the Unit
Consider the following points before selecting where to install:

  • Do not mount the battery on flammable construction materials.
  • The ambient temperature should be between 0’C and 45’C to ensure optimal operation.
  • The recommended installation position is to be adhered to the wall vertically.
  • Be sure to keep other objects and surfaces as shown in the right diagram to guarantee sufficient heat dissipation and to have enough space for removing wires.

Please follow below steps to implement battery connection:

  1. Assemble battery ring terminal based on recommended battery cable and terminal size.
  2. Connect all battery packs as units requires. It’s suggested to connect at least 2 sets for inverter larger than 8KVAin parallel connection.

Note : If you need the battery wake-up when the grid is back, connect the battery with grid use power adapter and communication line 1 shown in the package list.

Read User Manual Online (PDF format)