Nordpeis SD-YOU00-C10 YoU Ceiling Stove Instruction Manual
- September 17, 2024
- Nordpeis
Table of Contents
- IMPORTANT SAFETY PRECAUTIONS!
- Before installing a new stove
- Chimney draught
- Technical information
- Distance to combustible material
- Assembly
- Ignition air control:
- Lighting the fire for the first time
- Maintenance
- Warranty
- Advice on lighting a fire
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Nordpeis SD-YOU00-C10 YoU Ceiling Stove Instruction Manual
IMPORTANT SAFETY PRECAUTIONS!
-
Please follow the installation manual when connecting your stove / fireplace to the chimney / flue pipe. If connected differently from instruction please, consider the heat radiation from the flue pipe to the surrounding materials.
-
Before use, please carefully read the user manual and follow the instructions.
-
Integrated or defined convection openings may never be reduced or partially obstructed. This may lead to overheating, which again can cause house fire or serious damage to the product.
-
Use only designated fire starters. Never use gasoline, diesel or other liquids to start the fire.
This may cause explosions! -
Never use other fuel than natural dry chopped wood. Briquettes, peat, coke, coal and waste from construction materials develops far higher temperatures and emissions than natural wood.
Since your product has been designed for use with natural wood only, other fuels may damage the product, chimney and surrounding constructions. -
In case of damage to glass or door gasket, all use of the product must be discontinued until the damage has been repaired.
-
Products connected to a vented steel chimney must never be operated with open or ajar door other than reloading of wood or shortly during kindling process.
Failure to follow these precautions will leave your warranty void and expose people and property to danger.
Advise : Even if not required in your area, it is always wise to have a qualified stove / fireplace fitter do the installation, or at least the final inspection before use.
Before installing a new stove
All our products are tested according to the latest European requirements.
However, several European countries have local regulations for installation of
fireplaces, which change regularly. It is the responsibility of the client
that these regulations are complied with in the country/region where the
fireplace is installed.
Nordics AS is not responsible for incorrect installation.
Important to check:
- distance from firebox to combustible/flammable materials
- insulation materials/requirements between fireplace surround and back wall
- size of floor plates in front of fireplace if required
- flue connection between firebox and chimney
- insulation requirements if flue passes through a flammable wall
Chimney draught
Compared with older models, the clean burning stoves of today put significantly higher demands on the chimney. Even the best stove will not work properly if the chimney does not have the right dimensions or is not in good working order. The draught is mainly controlled by gas temperature, outside temperature, air supply as well as the height and inner diameter of the chimney. Recommended effective chimney height is minimum 3 meters. For draft requirements at nominal heat output, see technical table.
The draught increases when:
- The chimney becomes warmer than the outside air
- The active length of the chimney over the hearth increases
- There is good air supply to the combustion
It can be difficult to obtain the right draught conditions in case the chimney is too large relative to the stove, as the chimney does not heat up well enough. In such cases you should contact professional for evaluation of possible measures. Draught that is too strong can be controlled with a damper. If necessary, contact a chimney sweeper.
Air supply
A set for fresh air supply is available as accessory.
This will ensure that the air supply to the combustion chamber is less
affected by ventilation systems, kitchen fans and other factors which can
create a down-draught in the room. In all new construction, we strongly
recommend that it is designed and prepared for direct supply of outside air.
In older houses, the use of fresh air supply set is also recommended.
Insufficient air supply can cause down-draught and thereby low combustion
efficiency and the problems that this entails: soot stains on the glass,
inefficient use of the wood and a soot deposits in the chimney.
Warning! Keep the air intakes, supplying combustion air, free from
blockage.
If the requirements for ventilation are NOT complied with, the product can
overheat. This can cause a fire.
Warning! Extractor fans when operating in the same room or space as the appliance may cause problem.
Warning! Keep the air intakes, supplying combustion air, free from
blockage.
If the requirements for ventilation are NOT complied with, the product can
overheat.
This can cause a fire.
Warning! Extractor fans when operating in the same room or space as the appliance may cause problem.
For your own safety, comply with the assembly instructions. All safety distances are minimum distances. Installation of the stove must comply with the current rules and regulations of the country where the product is installed. Nordpeis AS is not responsible for wrongly assembled stoves.
The illustrations indicate the approximate centre height of the recess for the flue. Consider possible inclination of the flue prior to perforating the chimney. Distortions in floors and walls may also influence the height. Place the stove for accurate height and positioning of the flue/chimney connection.
Subject to errors and changes.
For the latest updated version go to
www.nordpeis.com.
Technical information
The stoves from Nordpeis all have secondary combustion and are clean burning.
The combustion takes place in two phases: first the wood burns and then the
gases from the fumes are lit by the hot air.
This ensures that these new stoves have minimal emissions of soot particles
and un-burnt gases (such as CO) and are thus better for the environment. Clean
burning stoves require a small amount of wood in order to obtain a good heat
output. Use exclusively clean and dry wood. We recommend seasoned hardwood
with a maximum moisture content of 20%.
YoU Ceiling|
---|---
Material| Steel
Weight| 128 kg
Draught system| Air vent control
Combustion system| Secondary combustion (clean burning)
Maximum fuel length| 30 cm
Flue outlet| Top
Flue| Outer Ø 150 mmAlternative versions exist due to National require-
meets
Flue gas temperature at flue connector| 319 °C
Flue gas mass flow| 5,3 g/s
Nominal heat output| 6,6 kW
Efficiency| 82 %
CO (13% O 2)| <1250 mg/m³
---|---
Flue gas temperature| 266 °C
Draft| 12 Pa
Fuel recommended| Wood
Fuel length recommended| 13-25 cm
Fuel charge| 1,55 kg
Refuelling interval| 45 minutes
Operation| Intermittent
- Intermittent combustion refers to normal use of a fireplace, i.e. new wood is inserted when the previous load has burned down to ember Warning: If the requirements for ventilation are NOT complied with, the cooling airflow around the product will be considerably reduced and the product can overheat.
This can cause a fire.
Distance to combustible material
Ensure that the safety distances are respected (FIG 2-2a).
When connecting a steel chimney to the top outlet use the security distances
required from the manufacturer
Assembly
Operating control
When the stove is in an upright position, and prior to connecting it, control
that all functions are easy to manoeuvre and appear satisfactory.
A. Ignition vent control | B. Air vent control |
---|
Pushed in = closed (1)
Pull out = open (2)| Left position = closed
Right position = open
Ignition air control:
This stove is fitted with an automatic closure of the ignition vent. The ignition vent control will automatically close (retract) when sufficient temperature of the flue gases is reached after kindling. This will ensure that the ignition air is not left open longer than necessary, reducing emissions and prolonging the burn time. Note that the Ignition air control can also be shut manually at any stage.
IMPORTANT!
Always ensure that the ignition air control is closed after burning to prevent
discharging the battery.
THE STOVE IS EQUIPPED WITH A SOUND ALARM.
Ignition vent in open position:
-
A short sound signal once per minute is emitted to indicate that battery change is needed as soon as possible. Deactivate the sound signal by closing the vent and replace battery.
-
A short sound signal is emitted once per second over a 30 second period to indicate that the battery is too exhausted to operate the vent. Deactivate the sound signal by closing the vent and replace battery.
-
A long sound signal is emitted once per second if a failure in the vent system is detected and the automatic device is unable to shut the vent. Deactivate the sound signal by closing the vent manually.
If failure is detected, please try to replace the battery before contacting service. -
If a short and long sound signal is emitted intermittently over a period of 30 seconds, contact service. The vent must be used manually.
Important:
-
This appliance requires a type 6LR61 9V battery.
Other types are of lower capacity and may not work or have very limited service life. -
Do not attempt to change battery while the stove is in use or still hot!
Connecting the flue
Please be aware when connecting the 150 mm flue to the smoke dome that the
flue is placed outside the flue outlet collar. *Alternative versions exist due
to National requirements. For the flue connection to the chimney, follow the
recommendations from the chimney manufacturer.
We recommend a maximum chimney weight of 150 kg
Lighting the fire for the first time
When the stove is assembled and all instructions have been observed, a fire can be lit.
Take care when inserting logs into the burn chamber, in order not to damage the Thermotte plates. Please note that there might be some humidity in the insulation plates which can result in a slower burn rate the first few times the stove is used. These will be resolved once the humidity has evaporated. It is advisable to ventilate the room well when firing for the first time as the varnish on the stove may release some smoke or smell. Both the smoke and smell will disappear and are not hazardous.
Lighting a fire
Insert small dry pieces of kindling wood,open the air vent control and ignite.
When the flames are stable and the chimney is warm, the air supply is
regulated with the air vent control.
When there is a glowing layer of ash, new wood logs can be inserted. Pull the hot ember to the front of the combustion chamber when inserting new logs so that the wood is ignited from the front. The fire should burn with bright and lively flames.
Using the stove with low combustion effect and firing around the clock increase pollution as well as the risk for a fire in the chimney. Never allow the stove or flue to become glowing red. Turn off the air vent control should this happen. Regulation of the air vent control takes some experience, but after a little while a natural rhythm for the fire will be found.
IMPORTANT! Always remember to open the air vent control when new wood logs are inserted into a hot burn chamber. Let the flames get established on the wood before the air supply is reduced.
When the draught in the chimney is low and the vents are closed, the gas from the firewood can be ignited with a bang. This can cause damages to the product as well as the immediate environment.
Maintenance
Cleaning and inspection
The stove should be inspected thoroughly and cleaned at least once per season
(possibly in combination with the sweeping of the chimney and chimney pipes).
Ensure that all joints are tight and that the gaskets are rightly positioned.
Exchange any gaskets that are worn or deformed.
Remember that the stove must always be cold when inspected.
Automatic ignition air control:
The automatic air control is powered by a 6LR61 / 9V battery. Before putting
the stove to use, please connect the supplied battery and attach the
battery/control box as shown in FIG. 21.
The battery is expected to last for 1000 operations.
We recommend replacing the battery before the new heating season. When the
control starts sounding a beep when closing, the battery should be replaced.
FAILURE TO REPLACE THE BATTERY WILL PREVENT THE AUTOMATIC IGNITION CONTROL TO
WORK, and must then be operated manually.
Ashes
The ashes should be removed at regular intervals.
Be aware that the ashes can contain hot ember even several days after the fire
is finished. Use a container of non-combustible material to remove the ashes.
It is recommended to leave a layer of ashes in the bottom as this further
insulates the burn chamber. Take care with the Thermometer plates when the
ashes are removed particularly when using an ash shovel, so as not to damage
them.
Thermometer™ insulating plates
The insulation plates (Thermometer) are classified as “wear and tear” parts
which will require to be exchanged after some years. The wear time will depend
on the individual use of your product. Nordpeis offers a one-year warranty on
these parts. After this, replacements can be purchased.
If new plates are needed, contact your dealer.
Please note : Wood logs that are too long can cause strain and crack the plates, due to the tension created between the side plates.
Door and glass
Should there be any soot on the glass it may be necessary to clean it. Use
dedicated glass cleaner, as other detergents may damage the glass. (Attention!
Be careful, even dedicated glass cleaner can damage the varnish on the door
frame). A good advice for cleaning the glass is to use a damp cloth or kitchen
roll paper and apply some ash from the burn chamber.
Rub around the ash on the glass and finish off with a piece of clean and damp
kitchen roll paper. Attention! Only clean when the glass is cold.
Check regularly that the transition between the glass and the door is completely tight. Periodically, it may be necessary to change the gaskets on the door to ensure that the burn chamber is air tight and working optimally. These gaskets can be bought as a set, usually including ceramic glue.
CERAMIC GLASS CANNOT BE RECYCLED
Ceramic glass should be disposed of as residual waste, together with
pottery and porcelain
Recycling of the ceramic glass
Ceramic glass cannot be recycled. Old glass, breakage or otherwise unusable
ceramic glass, must be discarded as residual waste. Ceramic glass has a higher
melting temperature, and can therefore not be recycled together with glass. In
case it would be mixed with ordinary glass, it would damage the raw material
and could, in worst case end the recycling of glass. It is an important
contribution to the environment to ensure that ceramic glass does not end up
with the recycling of ordinary glass.
Packaging recycle
The packaging accompanying the product should be recycled according to
national regulations.
Warranty
Warning!
Use replacement parts recommended only by the Manufacturer.
Warning!
Any unauthorized modification of the appliance without written permission of
the Manufacturer are prohibited.
For detailed description of the warranty conditions see the enclosed warranty card or visit our website: www.nordpeis.com
Advice on lighting a fire
The best way to light a fire is with the use of lightening briquettes and dry
kindling wood. Newspapers cause a lot of ash and the ink is damaging for the
environment.
Advertising flyers, magazines, milk cartons and similar are not suitable for
lighting a fire. Good air supply is important at ignition.
Warning: In order to avoid injuries, please be aware that the surface may become hot during operation and that extra care need to be taken to avoid skin burn.
Warning : NEVER use a lighting fuel such as petrol, kerosene, alcohol or similar for lighting a fire. This could cause injury to you as well as damaging the product.
Use clean and dry wood with a maximum moisture content of 20%. Humid wood requires a lot of air for the combustion, as extra energy/heat is required for drying the humid wood and the heat effect is therefore minimal. This in addition creates soot in the chimney with the risk of creosote and chimney fire.
In case of a chimney fire, close the door and air supplies on the stove and call the Fire Brigade. After a chimney fire the chimney must in all cases be inspected by an authorized chimney sweeper before you use the appliance again.
Storing of wood
In order to ensure that the wood is dry, the tree should be cut in winter and
stored during the summer, covered and in a location with adequate ventilation.
The wood pile must never be covered by a tarpaulin lying on the ground as the
tarpaulin will then act as a sealed lid that will prevent the wood from
drying. Always keep a small amount of wood indoors for a few days before use
so that moisture in the surface of the wood can evaporate.
Usage
Not enough air to the combustion may cause the glass to soot. Hence, supply
the fire with air just after the wood is added, so that the flames and gases
in the combustion chamber are properly burnt. Open the air vent in order for
the flames to establish properly on the wood.
Note that the air supply for the combustion also can be too large and cause an uncontrollable fire that very quickly heats up the whole combustion chamber to an extremely high temperature (when using with a closed or nearly closed door). For this reason you should never fill the combustion chamber completely with wood. Choice of fuel
All types of wood, such as birch, beech, oak, elm, ash and fruit trees, can be used as fuel in the stove. Wood species have different degrees of density – the more dense the wood is, the higher the energy value. Beech, oak and birch has the highest density.
Attention! We do not recommend using fuel briquettes/ compact wood in our products. Use of such fuel may cause the product to overheat and exceed the temperatures determined safe. Burning briquettes/ compact wood is done so at your own risk and only small amounts (max 1/3 of normal load) should be used for each load.
Warning:
NEVER use impregnated wood, painted wood, plywood, chipboard, rubbish, milk
cartons, printed material or similar. If any of these items are used as fuel
the warranty is invalid.
Common to these materials is that during combustion they can form
hydrochloride acid and heavy metals that are harmful to the environment,
yourself and the insert.
Hydrochloride acid can also corrode the steel in the chimney or masonry in a
masonry chimney.
Also, avoid burning with bark, sawdust or other extremely fine wood, apart
from when lighting a fire. This form of fuel can easily cause a flash over
that can lead to temperatures that are too high.
Warning:
Make sure the insert is not overheated – it can cause irreparable damage to
the product. Such damage is not covered by the warranty.
Some advice in case of combustion problems
Error | Explanation | Solution |
---|---|---|
No draught | The chimney is blocked | **** Contact a chimney sweeper / |
dealer for more information or cleanthe flue, smoke baffle and burn chamber.
The flue is sooty or there is accumulated soot on the smoke baffle
The smoke baffle is wrongly positioned| Verify the assembly of the smoke
baffle – see assembly instructions.
The stove release smoke when lighting the fire and during combustion|
Downdraught in the room caused by no draught, that the house is too “air
tight”.| Light the fire with an open window. If this helps, more/bigger vents
must be installed in the room.
Downdraught in the room – caused by extractor and/or central ventilation
system that pulls too much air out of the room.| Turn off/regulate extractor
and/or other ventilation. If this helps,more vents must be installed.
The flues from two fireplaces/stoves are connected to the same chimney at the
same height.| One flue must be re positioned. The height difference of the two
flue pipes must be of at least 30 cm.
The flue is in a declining position from the smoke dome to the chimney.| The
flue must be moved so that there is an inclination of at least 10º from smoke
dome to chimney. Possibly install a smoke suction device*.
* The flue is too far into the chimney.| The flue must be reconnected so
that it does not enter into the chimney but ends 5 mm before the chimney inner
wall. Possibly install a smoke suction device.
Soot hatch in the basement or attic that is open and thus creating a false
draught.| Soot hatches must always be closed. Hatches that are not tight or
are defected must be changed.
Damper/top draught vents or doors on fireplaces that arenot in use are open
and create a false draught.| Close damper, doors and top draught vents on
fireplaces that arenot in use.
An open hole in the chimney after that a fireplace hasbeen removed, thus
creating a false draught.| Holes must be completely sealed off with masonry.
Defect masonry in the chimney, e.g. it is not airtight around the flue pipe
entry and/or broken partition inside the chimney creating a false draught.|
*** Seal and plaster all cracks and sites that are not tight.
The cross-section in the chimney is too large which results in no or very low
draught.| The chimney must be refitted, possibly install a smoke
suctiondevice.
The cross-section in the chimney is too small and the chimney cannot carry out
all the smoke.| Change to a smaller fireplace or build new chimney with a
largercross section. Possibly install a smoke suction device.
The chimney is too low and hence a poor draught.| Increase the height of the
chimney and/or install a chimney cap/ smoke suction device.
The stove releases smoke inside when it is windy outside.| The
chimney is too low in relationship to the surrounding terrain, buildings,
trees etc.| Increase the height of the chimney and/or install a chimney cap/
smoke suction device.
Turbulence around the chimney due to the roof beingtoo flat.| Increase the
height of the chimney and/or install a chimney cap/ smoke suction device.
The stove does not heat sufficiently.| The combustion receives too much
oxygen due to a leakage under the lower border of the stove or too strong
chimney draught. Difficult to regulate the combustion and the wood burn up too
quickly.| Any possible leakage must be sealed off. A draught regulator or
possibly a damper can reduce the chimney draught. NB! A leakage of only 5 cm2
is enough for 30% of the heated air to disappear.
Too much draught| The smoke buffer is wrongly positioned.|
Verify the positioning of the smoke buffer – see assembly instructions.
In case of using oven-dried wood, this requires less air supply than when
using normal wood.| Turn down the air supply.
The gaskets around the door are worn and totally flat.| Replace the gaskets,
contact your dealer.
The chimney is too large.| Contact chimney sweeper or other professional for
more details.
****The glass is sooty| The wood is too wet.| Only use dry wood with
a humidity of maximum 20%.
** The air vent control is closed too tightly.| Open the air vent control
to add air to the combustion. When new wood logs are inserted all vent
controls should be completely opened or the door slightly opened until the
flames have a good take on the wood.
**White glass| Bad combustion (the temperature is too low)| Follow
the guidelines in this user guide for correct combustion.
** Using wrong material for combustion (such as: painted or impregnated
wood, plastic laminate, plywood etc)| Ensure to use only dry and clean
wood.
**Smoke is released when the door is opened| A levelling out of
pressure occurs in the burn chamber.| Open the air vent control for about 1
min before opening the door– avoid opening the door too quickly.
The door is opened when there is a fire in the burnchamber.| Open the door
carefully and/or only when there is hot ember.
****White smoke| The combustion temperature is too low.| Increase the
air supply.
The wood is humid and contains water damp.| Ensure to use only dry and clean
wood.
Black or grey/ black smoke**| Insufficient combustion.| Increase the air
supply.
IMPORTANT: Included in the installation kit are 4 x Ø8×120 wood screws.
These are only intended for use in solid wood beams. Follow the instructions
below on how to insert cross-beams between the original beams in order to
create a safe construction. If your ceiling construction is made from other
material we strongly suggest to use protruding M8 bolts or threaded bars with
appropriate washers on top.
We recommend a maximum chimney weight of 150 kg.
ATTENTION : Always follow the chimney manufacturer’s instructions and
safety distances!
-
YoU Ceiling = mm / air / chimney
FIG 1 -
YoU Ceiling- safety distances”
FIG 2
Firewall
Combustible material
References
- art.no
- The largest fireplace supplier in Norway | Nordpeis
- Nordpeis - Wärmende Innovation | Nordpeis
- Suurin valikoima takkoja | Nordpeis
- Cheminées et poêles | Un design chaleureux | Nordpeis
- Nordpeis - utforsk vår verden av peiser og vedovner | Nordpeis
- Störst på eldstäder - hitta din favorit | Nordpeis
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>