Product Usage Instructions
-
Check Serial (RS232) Cable:
Ensure you are using the Seaward supplied serial cable with the white tag containing the necessary information. -
Connection:
Use a straight through Serial connection or a Seaward-approved USB adaptor for connectivity. -
Database Setup:
Open or create a new database in PATGuard 3. Select Instruments and then Add a Test Instrument using the icon. -
Settings Configuration:
Click the settings button and make sure your options are set correctly. -
Data Transfer:
Select Data Transfer and Download from Tester. Choose the instrument from the dropdown box and select the COM port. -
Start Transmission:
Select Database and then OK. You will receive a message prompting you to start the transmission.
Frequently Asked Questions (FAQ):
- Q: Where can I get further assistance?
A: For more help, please contact Seaward at https://www.seaward.com/cms/enquire/
How to download a Europa into PATGuard 3?
The following document is intended to be a troubleshooting guide to ensure you are downloading your Supernova / Europa in the correct manner. Please check all aspects of this before contacting the technical support helpline.
- Check your Serial (RS232) Cable. This should be the Seaward supplied serial cable. It will have a white tag, with the information printed. “For use with the following testers, both Up & Download Only, Supernova….” And on the other side the Part No. 194A919 or 44B113.
- Are you using a straight through Serial connection, or is this via a Serial to USB adaptor. If so we can only guarantee that a USB adaptor supplied by us will work as this has been tried and tested with our cable. More information and purchase details for this adapter can be found at http://www.seaward.com/products/portable-appliance-testing-equipment/portable-appliance-testing accessories/leads-adaptors-1/usb-serial-port-adaptor or call our sales team.
- Open or create a new database in PATGuard 3 select “Instruments” and then “Add a Test Instrument” using the icon.
- At this point it is also advisable to click the settings button and ensure your options are set as below;
- Select “Data Transfer” and “Download from Tester”.
- Select the instrument from the dropdown box and then select the COM port. Select “Database” and then “OK”, at this point you will receive a message “Please start your transmission now”; 15- 18 Bracken Hill, South West Industrial Estate, Peterlee, County Durham, SR8 2SW, United Kingdom
If you require more help, please contact us at https://www.seaward.com/cms/enquire/.
15-15-18 Bracken Hill, South West Industrial Estate, Peterlee, County Durham,
SR8 2SW, United Kingdom18 Bracken Hill, South West Industrial Estate,
Peterlee, County Durham, SR8 2SW, United Kingdom
t: +44 (0) 191 586 3511 | f: +44 (0) 191 586 0227 | e:
sales@seaward.comt: +44 (0) 191 586 3511 | f: +44
(0) 191 586 0227 | e: sales@seaward.com
seaward.comseaward.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>