Blueair CP7i Classic Pro Air Purifier User Manual

September 7, 2024
Blueair

Blueair CP7i Classic Pro Air Purifier

Blueair Classic Pro

Introducing the Classic Pro air purifier with two available models, including the CP7i and CP9i  series. Equipped with a pre-filter and a main filter, our purifiers effectively purify the air you breathe.  The Classic Pro models come with integrated controls and built-in sensors. All models have a digital display showing particulate data. The CP9i model is capable of displaying information on both PM and TVOC data. To adjust the settings of your air purifier, you can either use the control panel on the device itself or utilize the Blueair App for remote control. The Blueair  App grants access to additional features and functions.

Tips for Optimal Cleaning Results

  • Ensure that the size of the room where the air purifier is used does not exceed the recommended capacity.
  • Position the air purifier in an area where air can freely flow in and out, ensuring proper circulation.
  • Maintain a distance of at least 10cm (4″) between the air purifier and any other objects.
  • Keep the doors and windows closed while the air purifier is in operation.
  • Run the air purifier for 24 hours each day and activate the PhotonPure technology function.
  • Use only genuine Blueair filters provided by the original factory.
  • Clean the Pre-filter and Air Quality Sensor monthly with a vacuum to remove dust and other debris.
  • Replace the main filters when the filter replacement symbol appears on the control panel.
  • Refer to the maintenance instructions in this owner’s manual for proper care.

The air purifier consists of a motor, fan, and filter. Its purpose is to enhance indoor air quality by eliminating pollutants from the air, thereby improving the overall air quality.

Important safety instructions

Product name

  • Classic Pro CP7i
  • Classic Pro CP9i

Model number

  • 6712211000
  • 6912211000
  • Classic Pro ar purifier is an electrical appliance for indoor use only. Take the necessary precautions to reduce the risk of fire, electric shock or injury.
  • This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning the use of the appliance by a person responsible for their safety.
  • Supervise children to ensure that they do not play with the appliance.
  • Cleaning and product maintenance should not be conducted by children.
  • Always disconnect the appliance from the power supply before maintenance.
  • If your Blueair appliance is found to be defective, we will replace it with the same or a similar model at no cost, per the warranty terms. Please use caution attempting repairs yourself, as this presents the danger of electrical shock or injury.
  • Ensure that the power cable and the power plug are not at risk of getting damaged.
  • If the appliance is damaged or malfunctions, turn it off, disconnect it from the power supply, and contact Blueair.
  • The power plug must be irmly inserted in the power socket.
  • When disconnecting the unit from the power supply, do not pull on the power cord, pull on the power plug.
  • Use the power cable provided with your Blueair air purifier to plug directly and immediately into an appropriate, electrical outlet.
  • Do not use an extension cord or a power strip. Refer to the rating label on your appliance.
  • Do not alter the power plug in any way. If the plug does not it into the outlet, contact quali ied personnel to install the proper outlet.
  • Do not use the included power cord for anything else but the appliance.
  • Do not allow objects to enter or block the air inlets and air outlets as this can cause electric shock or damage the appliance.
  • Do not place any objects on top of or directly against the appliance.
  • Do not sit on, stand, climb onto or hang from the appliance.
  • Keep the appliance, including the power cable, at a safe distance from heated surfaces and open fire.
  • Keep the appliance and power plug away from water and other liquids.
  • Keep the appliance and power plug away from chemicals such as pesticides and deodorants.
  • Place the air purifier on the floor or a stable surface to prevent tipping.
  • Do not use the appliance outdoors or in wet environments such as bathrooms, laundry rooms or pool areas.
  • Always turn off and disconnect the appliance from the power supply before moving the unit, changing filters, cleaning, or carrying out maintenance procedures.
  • Never clean with gasoline, chemical solvents, or corrosive materials as these agents may damage the air purifier.
  • To reduce the risk of electric shock, this equipment has a grounding-type plug that has a third (grounding) pin. This plug will only fit into a grounding-type power outlet.

WARNING: RISK OF ELECTRIC SHOCK – These servicing instructions are for use by qualified personnel only. To reduce the risk of electric shock, do not perform any servicing other than that contained in the operating instructions unless you are qualified to do so.
WARNING: Skin or eye damage may result from directly viewing the light produced by the lamp in this apparatus. Always disconnect the power before replacing the filter or servicing. The PhotonPure module can not be replaced.

Regulatory information

WARNING: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates,  uses and can radiate radio frequency energy and, if not installed and used by the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and the receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/ TV technician for help. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two  conditions:
  • This device may not cause harmful interference.
  • This device must accept any interference received, including interference that may cause undesired operation.

This Class B digital apparatus complies with Canadian ICES-003.

This device contains license-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canada’s license-exempt RSS(s). Operation is subject to the following two conditions: (1) This device may not cause interference, and (2) This device must accept any interference, including interference that may cause undesired operation of the device.FCC/ISED RF Exposure Information: This equipment should be installed and operated with a minimum distance of 10 centimeters (4 inches) between the radiator and your body. This product complies with the maximum allowable concentration of ozone of 0.050 parts per million by volume(ppmv) in a 24-hour period. This appliance comply with the applicable provisions of applicable US Federal requirements, including 21 CFR, Chapter 1, Subchapter J, Radiological Health.

Product map

  • A Control panel
  • B Display
  • C Air quality sensor
  • D Air quality indicator
  • E Air outlet
  • F Feet and wheels
  • G Handle
  • H Air inlet
  • I Pre-filter
  • J Replacement filters *
  • K PhotonPure module

Note! The plastic sealing  is still on the filter. Please remove before first use.

  • CP7i has two filters/motors, one PhotonPure module, and CP9i has three filters/motors and two PhotonPure modules.

Air quality status
The Classic Pro air purifiers have a laser particle sensor to measure the fine particles (PM 1, PM 2.5, and PM 10) levels. The LED indicator displays air quality status in five colors – from excellent (blue) to very polluted (red). LED indicator color is based on the worst of the three PM levels. Model CP9i also has a TVOC sensor.

Based on PM reading

Getting started

Note! For first time use, the built-in laser sensor will take up to 1 day to calibrate to its new home which is why the  air quality indicator will show “Blue – Excellent” at first start up.

How to use tips

Change brightness
Press and hold your finger on the On/ Standby button and tap the Fan Speed button with the other finger to adjust brightness. If the brightness is on the lowest level, then it will increase by one  level. If the brightness is on the highest level, then it will decrease by one level.

Reset Wi-Fi
If you choose not to connect the product, the Wi-Fi can be turned for about 15 seconds and then release. The Wi-Fi will be turnedIf you want to re-connect your air purifier, hold Auto button for 5 seconds until Wi-FI LED starts blinking. Then follow the instructions in the “Connect to the Blueair app” chapter.

Enable/disable Child lock
Tap On/Standby and Night Mode button at the same time shortly (until all the LEDs of the interface light up and blink once), then release. When the Child lock is on the air purifier will continue to operate but the speed/mode button will be locked.

Filter reset
Extra long press Fan Speed button for about 15 seconds (until all the LEDs of the interface light up), then release. The red filter replacement indicator will blink three times and then disappear.

Reminder! After replacing the filter, it is required to manually conduct a filter reset on the air purifier.

Factory reset
Extra long press On/Standby button for about 15 seconds (until all the LEDs of the interface light up and blink four times). Then release. After factory reset, the air purifier restarts with default configuration and will go into Standby mode.

Enable/disable PhotonPure
PhotonPure is OFF by default. To enable, press and hold Toggle button for 5s. When activated, PhotonPure LEDs turn on for 10s and are then off for 9mins 50s. To disable, hold Night mode button for 5s.

Enabling/disabling PhotonPure Technology in Night mode
PhotonPure is OFF by default. To enable when the device is in Night mode, press and hold Night mode button for 5s. When activated, PhotonPure LEDs turn 9mins 50s. To disable, hold Night mode button for 5s.

Connect to the Blueair app

Connecting to the Blueair app allows you to control the air purifier remotely and monitor filter usage. The app offers additional functions to the air purifier.

  • Step 1 Download the Blueair app from the App Store or Google Play.
  • Step 2 Open the app. Create or sign into your Blueair account.
  • Step 3 Click on Connect Product and select Classic Pro. Follow the instructions to complete app pairing.

First time connection tips

  • Make sure to turn on your air purifier. Press and hold the Auto mode button for 5 seconds to prepare air purifierfor pairing. Once the Wi-Fi indicator is blinking, it is ready tobe paired with your app.
  • Make sure you are using a visible Wi-Finetwork that is not hidden.VPN (Virtual PrivateNetwork) should be deactivated while using the Blueair App.
  • Bluetooth is required for first-time pairing. Turn your phone’s bluetooth on and keep your phone within 1 meter (3ft)  of the air purifier for initial pairing.
  • This air purifier can only connect to 2.4 GHz Wi-Fi. If you are using a dual-band Wi-Fi router, make sure to select 2.4GHz.
  • Keep your air purifier within 15 feet (4,5 meters) of your Wi-Fi router when connecting the product for the first time.

Maintenance information

The air purifier is delivered with a pre-filter and two main filters for CP7i, three main filters for CP9i installed. For best performance, clean the pre- filters regularly and change the main filters when the air purifier indicates filter change. To find the right main filter for your air purifier, use the Blueair app or visit www.blueair.com. The serial number and model name of your air purifier can be found on the rating label on the bottom of the air purifier.

Important! Always turn off and disconnect the appliance from the power supply before changing filters, cleaning, or carrying out maintenance procedures.

Blueair filter subscription program
Use the Blueair app or visit www.blueair.com to sign up for the Blueair filter subscription program.

Cleaning the pre-filter

For best performance, clean the pre-filter monthly.

Step 1
Open the back door of the air purifier by putting your hand in the handle andgently pulling the small door edge with your thumb.

Step 2
Clean the pre-filter, by wiping with a dust cloth or vacuuming with a soft brush attachment (not included).

Step 3
Put the door back onto the  air purifier.

  • This is an illustration only. The number of filters and motors differs based on the model. CP7i has two filters/motors and CP9i has three filters/motors

Important! Turn the air purifier off and disconnect the air purifier from the power supply before maintenance

Changing the main filter
The air purifier calculates the remaining lifetime of the filter based on actual usage and indoor pollution levels and will indicate when it is time to change the filters. The recommended time for filter change is 9-12 months depending on the usage and indoor air conditions. The filter replacement indicator will appear red on the control panel when it is time to change the filter.

  • Filter replacement indicator

Use only genuine Blueair filters compatible with your device model to ensure optimal performance and avoid malfunction.

Step 1
Turn off the air purifier and unplug it. Open the back door of the air purifier by putting your hand in the handle and gently pulling the small door edge with your thumb.

Step 3
Note! Remember to remove the wrapping from the new filters before usage. Insert the new filters.

Step 2
Remove the used replacement filters by gently pulling the  tab.

Step 4
Close the back door and perform the filter reset by long pressing the fan speed button for about 15 seconds until all lights come on.

  • This is an illustration only. The number of filters and motors differs is based on the model. CP7i has two filters/motors and CP9i has three filters/motors

We recommend regular cleaning to keep your air purifier in top condition. Please follow these recommendations when cleaning your air purifier.
General

  • Disconnect the air purifier from the power supply before maintenance.
  • Do not allow foreign objects to enter the air inlets or air outlets. This may cause electric shock or damage the air purifier.
  • Never clean with gasoline, chemical solvents or corrosive materials as these agents may damage the air purifier.
  • Make sure the air purifier is completely dry before connecting it to power.
  • Do not wash the main filter. The main filter is not washable or reusable.

Cleaning

  • Clean the pre-filter on a monthly basis by wiping with a dust cloth or vacuuming with a soft brush attachment (not included).
  • Wipe the exterior of the air purifier with a soft, clean, damp cloth.
  • Open the door and clean the inside of the door with a soft, clean, damp cloth.
  • Vacuum the small air inlets with a soft brush attachment (not included).
  • Vacuum the inside of the air purifier with a soft brush attachment (not included).
  • Clean and check the power cable and power plug for wear or damage.
  • Clean the sensor when changing the main filter.

Air quality sensor
The inlet for the air quality sensor is located at the front of the air purifier (left from the display) of the air purifier. Vacuum the area to clean the inlet for the sensor.

Moving the device

The air purifier has wheels at the back to make it easier to move.

  • Important! Unplug the air purifier before moving it.
  • Make sure that the back door on the air purifier is securely closed. Place your fingers inside of the handle at the back of the purifier while firmly holding the top panel with your thumb.
  • Move the air purifier by tilting it backward and rolling it on its wheels.

Troubleshooting

For more information and troubleshooting tips, please check the Support page on www.blueair.com

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals