Blueair DustMagnet User Manual

June 6, 2024
Blueair

DustMagnet™

User Manual

Please read this user manual carefully and keep it for future reference. The latest version of this user manual can be found on www.blueair.com

Note: There may be local variations of these models.

Product name: Model number:
5210i 5231111000
5240i 5231112000
5410i 5431111000
5440i 5431112000

Hereby, Blueair AB, declares that the radio equipment types in the above table is in compliance with Directive 2014/53/EU. The full text of the EU declaration of conformity is available at the following internet address: www.blueair.com/customer-support

Blueair DustMagnet™

Blueair DustMagnet™air purifiers are available in four models. All models are Wi-Fi enabled, have two pre-filters and two HEPASilent™ main filters to purify the air. All DustMagnet™ models have control functions and a built-in sensor. The air purifier is mainly composed of a motor, a fan, and filters. The air purifier removes contaminants from the air in a room to improve indoor air quality. You can change the air purifier settings at any time, using the control panel on the air purifier or remotely, using the Blueair app. Additional functions are available for all models through the Blueair app.

Recommendations for best performance

  • Use the air purifier in a room that does not exceed the room size recommendation.
  • Place the air purifier in a location where air can circulate freely in, out, and around the air purifier.
  • Do not place the air purifier closer than 10cm to another object.
  • During operation, keep doors and windows in the room with the air purifier closed.
  • Only use original Blueair filters.
  • Change the main filter when the filter replacement indicator appears on the control panel.
  •  Follow the maintenance instructions in this user manual.
    Blueair DustMagnetA Control panel| G Main filters
    ---|---
    B Air outlet| H Pre-filters
    C Air inlet| I Filter hatch
    D Fan and motor| J Power adapter (not in picture)
    E Air quality sensor| K User Manual (not in picture)
    F Legs|

Safety instructions

Blueair DustMagnet™ air purifiers are electrical appliances for indoor use only, take the necessary precautions to reduce the risk of fire, electric shock, or injury.

  •  This appliance can be used by children aged 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning the use of the appliance in a safe way and understand the hazards involved.

  • Children shall not play with the appliance.

  • Cleaning and maintenance shall not be made by children without
    supervision.

  • Always disconnect the appliance from the power supply before
    maintenance.

  • Do not attempt to open or service the appliance yourself. Service
    must be done by the manufacturer, service agent, or similarly qualified personnel using only original Blueair spare parts.

  • Ensure that the power cable and the power plug are not at risk of getting damaged. To avoid hazards, a damaged power cable must always be replaced by the manufacturer, service agent, or similarly qualified person.

  • If the appliance is damaged or is malfunctioning, turn it off, disconnect it from the power supply and contact Blueair.

  • The power plug must be firmly inserted into the power socket.

  • When disconnecting the unit from the power supply, do not pull the power cord, pull the power plug.

  • Use the power cable provided with your Blueair air purifier to plug directly and firmly into an appropriate, electrical outlet.

  • Do not use an extension cord or a power strip. Refer to the rating label on your appliance.

  • Do not alter the power plug in any way. If the plug does not fit into the outlet, contact qualified personnel to install the proper outlet.

  • Do not use the included power cord for anything else but the appliance.

  • Do not allow objects to enter or block the air inlets and air outlets as this can cause electric shock or damage the appliance.

  • Do not place any liquids on top of the product.

  • Do not put any objects heavier than 10kg on top of the product.

  • Do not put any objects directly against the appliance.

  • Do not sit on, stand, climb onto or hang from the appliance.

  • Keep the appliance, including the power cable, at a safe distance from heated surfaces and open fire.

  • Keep the appliance and power plug away from water and other liquids.

  • Keep the appliance and power plug away from chemicals such as pesticides and deodorants.

  • Place the appliance on the floor. The appliance must be placed on a stable surface.

  • Do not use the appliance outdoors or in wet environments such as bathrooms, laundry rooms, or pool areas.

Get started

Step 1
Carefully place the unit with the tabletop down on a stable soft surface.
Blueair DustMagnet - Step 1 Step 2
Attach the four legs onto the unit by screwing them on.
Blueair DustMagnet - Step 1 Step 3
Open the top filter hatch, pull out the main filter and remove the protective plastic wrapping.
Blueair DustMagnet - Step 3 Step 4
Insert the main filter back into the unit, and close the filter hatch.
Blueair DustMagnet - Step 4

Step 5
Open the bottom filter hatch, pull out the main filter and remove the protective plastic wrapping.
Blueair DustMagnet - Step 5 Step 6
Place the main filter back into the unit, and close the filter hatch.
Blueair DustMagnet - Step 6 Step 7
Plug the power adapter into a wall outlet.
Step 8
Press the On/Off button to turn the unit on.
See section Filters for more information regarding filter handling.

Connect to the Blueair app

Connecting the air purifier to the Blueair app allows you to control the air purifier remotely and change the settings. The app adds additional functions to the air purifier.

Step 1
Download the Blueair app from the App Store or Google Play.
Step 2
Open the Blueair app and follow the instructions to connect it to the air purifier.

Controls and indicators

Control the air purifier using the buttons on the control panel or using the Blueair app. The LED light below the symbol indicates active status.

On/Off
Press to turn On or Off.
Note! Wi-Fi continues to be in operation when the air purifier is turned off.

Airflow speed
Available airflow speed options are 0, 1, 2, 3, Auto mode, and Night mode.
Press to switch between airflow speed options, Auto mode, and Night mode.
Auto mode
In Auto Mode, the air purifier automatically controls the airflow based on air quality information from the sensor.

Night mode
In Night mode the air purifier uses low fan speed and dimmed LED lights. The brightness of the LED is possible to set in the Blueair app.

Autostart
The air purifier has an Autostart feature. This means that the unit will automatically restart at the set speed if a power failure occurs, the unit is unplugged or a power switch timer is used.

Wi-Fi Connection
A Wi-Fi function is available on all models and allows the air purifier to connect to the Blueair app and to receive functional updates. The LED light below the symbol indicates status.

Indicators

Status White light Connected to Wi-Fi network.
Status White “pulsating” light Wi-Fi On, ready for onboarding.
Status White fast “blinking” light Connection error.

See the Blueair app for further information regarding Wi-Fi connection. For support, visit www.blueair.com/customer-support

Filter indicator
The air purifier calculates the remaining lifetime of the filters based on usage and sensor readings and indicates when it is time to replace the filters.

Status Filter replacement No lifetime left of the filter.

Air quality information
The air quality levels for particulate matter (PM) are indicated using a color scale on the air quality indicator. This scale gives a reading for PM2.5, which are particles with a diameter of 2.5 micrometers or less.

Air quality level
Blueair DustMagnet - Air quality level
See the Blueair app for further information regarding air quality.

Filters

The air purifier is delivered with two pre-filters and two main filters installed. The filters purify the air from particles and gases. For best performance, clean the pre-filters regularly and change the main filters when the air purifier indicates filter change. To find the right main filter for your air purifier, use the Blueair app or visit www.blueair.com. The model number of your air purifier can be found on the rating label on the air purifier.

Important! Always turn off and disconnect the appliance from the power supply before changing filters, cleaning, or carrying out maintenance procedures.

Important! Do not use the unit without filters.

Blueair filter subscription program Use the Blueair app or visit www.blueair.com to sign up for the Blueair filter subscription program. (Not available in all markets)

Clean the pre-filters
For best performance, clean the pre-filters weekly.

Step 1
Turn the unit off and unplug it.
Blueair DustMagnet - pre-filters Step 1 Step 2
Open the top filter hatch and pull out the pre-filter.
Blueair DustMagnet - pre-filters Step 2 Step 3
Clean the pre-filter by wiping it with a dust cloth.
Blueair DustMagnet - pre-filters Step 3 Step 4
Place the pre-filter back into the unit and close the filter hatch.
Blueair DustMagnet - pre-filters Step 4 Step 5
Repeat steps 1-4 on the bottom pre-filter.
Blueair DustMagnet - pre-filters Step 5 Step 6
Plugin the unit.
Change the main filters
The air purifier calculates the remaining lifetime of the filters based on usage and sensor readings and indicates when it is time to change the filter. The recommended time for filter change is between 6-12 months depending on the indoor conditions.

A filter replacement indicator indicates when it is time to change the filters.

Filter replacement indicator

Important! Use only original Blueair filters suitable for the model to ensure proper function and performance of the air purifier, and to qualify for full warranty coverage.

Step 1
Turn the unit off and unplug it.
Blueair DustMagnet - coverage Step 1 Step 2
Open the two filter hatches.
Blueair DustMagnet - coverage Step 1 Step 3
Remove and dispose of the old main filters.
Blueair DustMagnet - coverage Step 3 Step 4
Note! Remove the protective plastic from the new main filters before use.
Insert the new main filters.
Blueair DustMagnet - coverage Step 4 Step 5
Close the two filter hatches.
Note! Make sure that the filter hatches are closed correctly.
Blueair DustMagnet - coverage Step 5 Step 6

Plugin the unit.
Note! Press the airflow speed button for 15s to reset the filter timer.
Blueair DustMagnet - coverage Step 6

Care and maintenance

General

  • Disconnect the air purifier from the power supply before maintenance.
  • Do not allow foreign objects to enter the air inlets or air outlets. This may cause electric shock or damage the air purifier.
  • Never clean with gasoline, chemical solvents, or corrosive materials as these agents may damage the air purifier.
  • Make sure the air purifier is completely dry before connecting it to power.
  • Do not wash the main filter. The main filter is not washable or reusable.

Cleaning

  • Clean the pre-filters by wiping them with a dust cloth or vacuuming with a soft brush attachment (not included).
  • Wipe the exterior of the air purifier with a soft, clean, damp cloth.
  • Vacuum the small air inlets with a soft brush attachment (not included).
  • Vacuum the inside of the air purifier with a soft brush attachment (not included).
  • Clean and check the power cable and power plug for wear or damages.
  • Clean the sensor when changing the main filter.

Moving the air purifier
Important!

  • Unplug the air purifier before moving it.
  • Make sure that the filter hatches on the air purifier are securely closed.
  • Lift the air purifier to move it. Do not drag or push the air purifier.

Clean the air quality sensor

The inlet for the air quality sensor is located at the back of the air purifier. Vacuum the opening to clean the inlet for the sensor.

Important! Do not use fingers or any unrecommended objects to clean inside the sensor inlet.

Step 1
Turn the unit off and unplug it.
Step 2
Remove the lid covering the sensor.
Step 3
Gently clean the sensor with a cotton swab, and attach the sensor lid.
Step 4
Plugin the unit.

Disposal and recycling

This air purifier should be disposed or recycled as electrical waste and the filter may be recycled as plastic. If you have questions regarding the disposal and recycling of this air purifier, please contact your local recycling facility for availability or Blueair dealer and ask for the correct method of recycling.

The crossed-out waste bin symbol on the appliance or on its packaging means that at the end of its useful lifespan, the product must be disposed of separately from ordinary household wastes.

Help and support
If you have questions about your product, please visit www.blueair.com or contact your local Blueair retailer.

To contact Blueair for personalized support, please visit www.blueair.com /customer-support

Warranty information

The Blueair Limited Warranty applies only if the air purifier is installed, used, and maintained according to the instructions in this manual.

For warranty conditions, please visit www.blueair.com/warranty

Warranty and returns
If you purchased the air purifier at one of our authorized retailers, please contact the same store to request assistance.

Specification

| 5210i/5240i| 5410i/5440i
---|---|---
Input Power, Frequency| 100-240VAC 50/60Hz| 100-240VAC 50/60Hz
Power consumption/ Rated input power (min/max)| 5-22W| 7-42W
Operating frequency| 2402-2480 MHz| 2402-2480 MHz
Output power| Max 5mW| Max 5mW
Sound level (min/max)| 29-45 dB| 31-50 dB
Recommended room size2| 22 m2| 35 m2
CADR Smoke2| 260 m3/h| 416 m3/h
CADR Dust2| 260 m3/h| 453 m3/h
CADR Pollen2| 293 m3/h| 450 m3/h

¹Sound pressure according to GB/T18801
²According to AHAM AC-1-2019

www.blueair.com
Blueair AB
Karlavägen 108
115 26 Stockholm
Sweden
Tel: +46 8 679 45 00
info@blueair.se

Blueair AB Middle East
Jafza One, Office No. AB1503
Jebel Ali Free Zone
P.O. Box No. 263947
Dubai, United Arab Emirates
Tel:+971 (4) 8821244
salesme@blueair.se

Blueair Inc.
125 S Clark
Suite 2000
Chicago, IL. 60603
USA
Tel: +1 888 258 3247
info@blueair.com

Blueair (Shanghai) Trading Co. Ltd.
Room 1001, City Gateway
No. 398 North Caoxi Road
Xuhui Distr, Shanghai,
China
Tel: 400 006 9693
info@unilever-le.com

Blueair Asia Ltd.
Unit 8C, 8/F, MG Tower,
133 Hoi Bun Road,
Kwun Tong, Kowloon,
Hong Kong
blueairasia@blueair.seTel: +852 2345 8988

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals