FUJITSU AUYA36LATN Split Type Air Conditioner Installation Guide

September 9, 2024
FUJITSU

FUJITSU AUYA36LATN Split Type Air Conditioner

Specifications

  • Indoor Unit: AUYA36LATN, AUYA45LATN
  • Outdoor Unit: AOYA36LATL, AOYA45LATL
  • Cooling Capacity: 10.0 kW (AUYA36LATN), 11.2 kW (AUYA45LATN)
  • Heating Capacity: 12.5 kW (AUYA36LATN), 14.0 kW (AUYA45LATN)

Electrical Data:

  • Power Source: 230V, 50Hz
  • Running Current: 13.6A (Cooling), 13.2A (Heating)
  • Input Watts: 3.11kW (Cooling), 3.02kW (Heating)
  • E.E.R.: 3.21 kW/kW (Cooling), 3.71 kW/kW (Heating)

Product Usage Instructions

Installation

  1. Ensure proper placement of indoor and outdoor units as per installation guidelines.
  2. Connect refrigerant pipes following the refrigerant system diagram.

Operation

  1. Power on the unit using the provided remote control or on-unit controls.
  2. Select the desired mode (cooling/heating) and set the temperature.

Maintenance

  1. Regularly clean the filters to ensure efficient operation.
  2. Check for any leaks in the refrigerant system and address them promptly.

FAQ

Q: How often should I clean the filters?
A: It is recommended to clean the filters every 2 weeks for optimal performance.

Q: What should I do if the unit displays an error code?
A: Refer to the error contents section in the manual to troubleshoot the issue or contact customer support for assistance.

SPLIT TYPE
AIR CONDITIONER
CASSETTE TYPE (50 Hz)

Indoor unit Outdoor unit
AUYA36LATN
AUYA45LATN
AOYA36LATL
AOYA45LATL

SPECIFICATIONS

TYPE Cooling & Heating
INDOOR UNIT AUYA36LATN
OUTDOOR UNIT AOYA36LATL
COOLING CAPACITY 10.0 kW
HEATING CAPACITY 11.2 kW

ELECTRICAL DATA

POWER SOURCE 230 V 50 Hz 230 V 50 Hz
RUNNING CURRENT Cooling 13.6 A
Heating 13.2 A 16.5 A
INPUT WATTS Cooling 3.11 kW
Heating 3.02 kW 3.77 kW
E.E.R. Cooling 3.21 kW/kW
Heating 3.71 kW/kW 3.71 kW/kW
STARTING CURRENT 15 A 15 A
MOISTURE REMOVAL 3.5 L/hr 4.5 L/hr
AIRCIRCULATION INDOOR 1,650 m3/hr 1,750 m3/hr
AIRCIRCULATION OUTDOOR 6,600 m3/hr 6,600 m3/hr

FAN MOTOR

INDOOR UNIT

| Discrimination| MFF-45RV| MFF-45RV
---|---|---|---
High speed| 680 r.p.m.| 720 r.p.m.
Med speed| 570 r.p.m.| 590 r.p.m.
Low speed| 480 r.p.m.| 500 r.p.m.
Quiet (cool/heat)| 400/420 r.p.m.| 440/440 r.p.m.

OUTDOOR UNIT

| Discrimination| MFE-60PO| MFE-60PO
Upper fan| 850 r.p.m.| 850 r.p.m.
Lower fan| 750 r.p.m.| 750 r.p.m.

NOISE LEVEL

INDOOR UNIT

| High speed| 50 dB| 52 dB
---|---|---|---
Med speed| 46 dB| 47 dB
Low speed| 41 dB| 42 dB
Quiet (cool/heat)| 36 dB / 37 dB| 39 dB / 39 dB
OUTDOOR UNIT| Cooling| 54 dB| 55 dB
Heating| 55 dB| 56 dB

DIMENSIONS

INDOOR UNIT           H x W x D 296 x 830 x 830 mm
OUTDOOR UNIT       H x W x D 1,290 x 900 x 330 mm

WEIGHT

INDOOR UNIT         Gross / Net 54 kg / 39 kg
OUTDOOR UNIT      Gross / Net 107 kg / 98 kg

COMPRESSOR

TYPE

| Hermetic type, Inverter, 4 poles, 3 phase,

DC motor, Twin Rotary

---|---
DISCRIMINATION| DA420A3F-21ZA
REFRIGERANT R410A| 3,350 g

REFRIGERANT CHARGE (R410A)

MAX PIPE LENGTH 50 m
MAX PIPE HEIGHT 30 m
Pipe length FULL CHARGE 20 m
30 m 3,850 g
40 m 4,350 g
50 m 4,850 g
ADDITIONAL CHARGE 50 g/m

DIMENSIONS

INDOOR UNIT
(Unit : mm)

Panel

FUJITSU-AUYA36LATN-Split-Type-Air-Conditioner-FIG-
\(2\)

Selection of setting

FUJITSU-AUYA36LATN-Split-Type-Air-Conditioner-FIG-
\(3\)

OUTDOOR UNIT (Unit : mm)

FUJITSU-AUYA36LATN-Split-Type-Air-Conditioner-FIG-
\(4\)

REFRIGERANT SYSTEM DIAGRAM

FUJITSU-AUYA36LATN-Split-Type-Air-Conditioner-FIG-
\(6\)

Refrigerant direction

: Cool

: Heat

CIRCUIT DIAGRAM

INDOOR UNIT

FUJITSU-AUYA36LATN-Split-Type-Air-Conditioner-FIG-
\(7\)

OUTDOOR UNIT

FUJITSU-AUYA36LATN-Split-Type-Air-Conditioner-FIG-
\(8\)

INDOOR PCB CIRCUIT DIAGRAM

FUJITSU-AUYA36LATN-Split-Type-Air-Conditioner-FIG-
\(9\)

CONTROLLER PCB ASSEMBLY

  • AUYA36LATN : K06AK-060BHSE-C1
  • AUYA45LATN : K06AK-060AHSE-C1

FUJITSU-AUYA36LATN-Split-Type-Air-Conditioner-FIG-
\(10\)

FUJITSU-AUYA36LATN-Split-Type-Air-Conditioner-FIG-
\(11\)

FUJITSU-AUYA36LATN-Split-Type-Air-Conditioner-FIG-
\(12\)

FUJITSU-AUYA36LATN-Split-Type-Air-Conditioner-FIG-
\(13\)

OUTDOOR PCB CIRCUIT DIAGRAM

INVERTER ASSEMBLY

  • AOYA36LATL : EZ-00603HUE
  • AOYA45LATL : EZ-00604HUE

FUJITSU-AUYA36LATN-Split-Type-Air-Conditioner-FIG-
\(14\)

FUJITSU-AUYA36LATN-Split-Type-Air-Conditioner-FIG-
\(15\)

OUTDOOR UNIT
POWER SUPPLY PCB ASSEMBLY
K04BA-0401HUE-P0

FUJITSU-AUYA36LATN-Split-Type-Air-Conditioner-FIG-
\(16\)

ERROR CONTENTS

INDOOR UNIT

TROUBLESHOOTING
Troubleshooting with the indoor display
Troubleshooting at the display is possible either on the wired or wireless remote control.

The OPERATION, TIMER and FILTER lamp operate as follows table according to the error contents.

FUJITSU-AUYA36LATN-Split-Type-Air-Conditioner-FIG-
\(18\)

: 0.5s ON/0.5s OFF (Flash) : OFF

ERROR CONTENTS

REMOTE CONTROL UNIT

Troubleshooting at the remote control LCD This is possible only on the wired remote control. If an error occurs, the following display will be shown. (“EE” will appear in the set room temperature display.)

Code Error contents

01  13

26  27

|

Indoor signal error

00| Wired remote controller abnormal
02| Indoor room temperature sensor error
04| Indoor heat exchanger temperature sensor (middle) error
28| Indoor heat exchanger temperature sensor (inlet) error
09| Float switch operated
0C| Outdoor discharge pipe temperature sensor error
06| Outdoor heat exchanger temperature sensor (outlet) error
0A| Outdoor temperature sensor error
0E| Heatsink sensor error
15| Compressor temperature sensor error
1d| 2-way valve temperature sensor error
1E| 3-way valve temperature sensor error
29| Outdoor heat exchanger temperature sensor (middle) error
20| Indoor manual auto switch abnormal
2A| Power supply frequency detection error
17| IPM protection
18| CT error
1A| Compressor location error
1b| Outdoor fan error
1F| Connected indoor unit abnormal
1c| Outdoor unit computer communication error
12| Indoor fan abnormal
0F| Discharge temperature error
24| Exessive high pressure protection on cooling
2c| 4-way valve abnormal
16| Pressure switch abnormal
2b| Compressor temperature error
19| Active filter abnormal
25| PFC circuit error

If “CO” appears in the unit number display, there is a remote control error. Refer to the installation instruction sheet included with the remote control.

OUTDOOR UNIT LEDS

Make a TEST RUN in accordance with the installation instruction sheet for the indoor unit.

When a malfunction occurs in the outdoor unit,the LED on the circuit board lights to indicate the error. Refer to the following table for the description of each error according to the LED.

LED Error contents
1 flash Communication error

(Indoor unit – Outdoor unit)

2 flash| Discharg pipe temperature sensor
3 flash| Outdoor heat exchanger temperature (outlet) sensor
4 flash| Outdoor temperature sensor
5 flash| Outdoor heat exchanger temperature (mid) sensor
6 flash| Discharge pipe temperature abnormal
7 flash| Compressor temperature sensor
8 flash| Heat sink temperature sensor
9 flash| Pressure switch abnormal
10 flash| Compressor temperature abnormal
12 flash| IPM error
13 flash| Compressor rotor position cannot detect
14 flash| Compressor cannot operate
15 flash| Outdoor fan abnormal (upper fan)
16 flash| Outdoor fan abnormal (lower fan)
5 sec. on/

1 sec. off repeat

|

Protect operation

1 sec. on/

1 sec. off repeat

|

Pump down operation

off| No error

SPECIAL INSTALLATION SETTING

PUMP DOWN (Refrigerant collecting operation)
Perform the following procedures to collect the refrigerant when moving the indoor unit or outdoor unit

When the product is stopped:

1| Press the PUMP DOWN switch on the outdoor unit.

(The LED on the outdoor unit circuit board starts flashing.) (1 sec. on / 1 sec. off repeated)

---|---
2| The pump down operation (cooling operation) begins right away. After oparation starts, close the three-way valve (liquid).
3| After 2 – 3 minutes, operation stops. Close the three-way valve (gas) within one minute after operations stops.
4| The LED will go out three minutes after it stops. Disconnect the power supply after confirming that the LED has gone out.

When the product is operating:

1| Press the PUMP DOWN switch on the outdoor unit. The LED on the outdoor unit circuit board starts flashing ( 1 sec. on / 1 sec. off repeated), and operation stops.

At this point, recovery has not been completed, so do not close the three-way valves. (liquid and gas)

---|---
2| The pump down operation (cooling operation) be- gins after three minutes. Close the three-way valve (liquid) after operation starts.
3| After 2 – 3 minutes, operation stops. Close the three-way valve (gas) within one minute after operations stops.
4| The LED will go out three minutes after it stops. Dis- connect the power supply after confirming that the LED has gone out.

When the pump down operation is repeated, temporarily disconnect the power supply after opening the closed valves (both liquid and gas). Reconnect the power supply after 2 – 3 minutes and perform the pump down operation.

When the start of the operation after pump down operation has been completed, temporarily disconnect the power supply after opening the closed valves (both liquid and gas).
Reconnect the power supply after 2-3 minutes and be sure to perform a test operation for cooling.

FUJITSU-AUYA36LATN-Split-Type-Air-Conditioner-FIG-
\(20\)

DANGER
This part (Choke coil) generates high voltages. Never touch this part.

| Tightening torque
---|---

Blank cap

| 6.35 mm (1/4 in.)| 20 to 25 N-m (200 to 250 kgf-cm)
9.52 mm (3/8 in.)| 20 to 25 N-m (200 to 250 kgf-cm)
12.70 mm (1/2 in.)| 25 to 30 N-m (250 to 300 kgf-cm)
15.88 mm (5/8 in.)| 30 to 35 N-m (300 to 350 kgf-cm)
19.05 mm (3/4 in.)| 35 to 40 N-m (350 to 400 kgf-cm)
Charging port cap| 10 to 12 N-m (100 to 120 kgf-cm)
Spindle (Hexagon wrench)| 6 to 7 N-m (60 to 70 kgf-cm)

FUJITSU-AUYA36LATN-Split-Type-Air-Conditioner-FIG-
\(22\)

PARTS

INDOOR UNIT Intake grille sub assy

FUJITSU-AUYA36LATN-Split-Type-Air-Conditioner-FIG-
\(23\)

Ref. No. Description Parts number Ord. Q’ty
1 Decoration Plate 9378017016
2 Intake Grille Sub Assy 9362818131
3 Intake Grille 9362767019
4 Filter 9362766005
5 Grille Reinforcement-T (A) 9362738002
6 Grille Reinforcement-T (B) 9362739009
7 Grille Reinforcement-T (C) 9362740005
8 Grille Reinforcement-T (D) 9362741002
9 Grille Reinforcement-T (E) 9362742009
10 Insulation (Grille)-A 9362780001
11 Insulation (Grille)-B 9362781008
12 Grille Hook Holder 9362782005
13 Grille Hook-A 9362779012
14 Grille Hook-B 9362778015
15 Grille Spring 9362755009
16 Grille Hinge Wire 9362754002

FUJITSU-AUYA36LATN-Split-Type-Air-Conditioner-FIG-
\(24\)

Ref. No. Description Part number Ord. Q’ty
21 Panel Frame Holder 9362758017
22 Panel Base 9362759014
23 Joint A 9362773003
24 Joint Shaft 9362771009
25 Louver Supporter 9362770019
26 Joint Gear 9362772006
27 Rubber Support Holder 9362799003
28 Step Motor 9900362027
29 Motor Gear 9362764001
30 Motor Holder 9362765008
31 Panel Frame Holder 9362761017
32 Panel Base Holder 9362760010
33 Louver Assy 9362836012
34 Wire Cover-B 9362788007
35 Spacial Nut-A (Large) 313005446653
36 Spacial Nut-B (Small) 313005446759
PCB Holder 9364855004
Indicator PCB Assy 9705891036

FUJITSU-AUYA36LATN-Split-Type-Air-Conditioner-FIG-
\(25\)

FUJITSU-AUYA36LATN-Split-Type-Air-Conditioner-FIG-
\(26\)

Ref. No. Description Parts number Ord. Q’ty
41 Evaporator A Assy 9373799047
42 Evaporator B Assy 9373800040
43 Distributor Assy 9371325101
44 Coupling Pipe Assy 9373038290
45 Separate Wall 9362737005
46 Clamp No.1219 313361271706
47 Pipe Thermistor 9703297021
48 Thermistor Spring-A 313728262708
49 Evaporator Holder Assy 9362802017
50 Wind Guide Board 9373444015
51 Reinforcement (Eva. )-A 9362749008
52 Reinforcement (Eva. )-B 9362750004
53 Kit (Drain Pan Assy) 9370934021
54 Reinforcement (Drain Pan) 9362757003
55 Rubber Cap 313005174654
56 Pump Unit 9900360030
57 Drain Hose 9362784009
58 Drain Port 9362786003
59 Drain pump Holder 9362753005
60 Pump Cover-A 9362775007
61 Pump Cover-B 9362776004
62 Cushion Rubber (Pump) 9362777001
63 Float Switch 9900361020
Rubber (Discharge Pipe) 313194159807

INDOOR UNIT Fan motor

FUJITSU-AUYA36LATN-Split-Type-Air-Conditioner-FIG-
\(27\)

Ref. No. Description Parts number Ord. Q’ty
81 Panel Top 9362732048
82 Cabinet A 9362800013
83 Cabinet B 9362801010
84 Cabinet C 9362733007
85 Cabinet D 9362734004
86 Inner Box 9362768009
87 Fan Motor Assy 9602486014
88 Fan Motor Holder 9378019010
89 Motor Rubber 9378020016
90 Turbo Fan Assy 9362803014
91 Washer (Turbo Fan) 9362756006
92 Cabinet-E 9362735001
93 Hook 9362736008
94 Terminal Base 9378027015
95 Terminal-3P 9306489045
96 Terminal Cover 9378023017
97 Wire Cover 9370624007
98 Pipe Cover Assy 9362819022
99 Clamp No.1219 313361271706

FUJITSU-AUYA36LATN-Split-Type-Air-Conditioner-FIG-
\(29\)

INDOOR UNIT Control unit

FUJITSU-AUYA36LATN-Split-Type-Air-Conditioner-FIG-
\(30\)

Ref. No.|

Description

| Parts number| Ord. Q’ty
---|---|---|---
101| Control Box| 9368523015|
102| Bellmouth B| 9362774000
103| Control Box Assy| 9368533007
104| Controller PCB Assy (36)| 9707393101
104| Controller PCB Assy (45)| 9707393095
105| Power Supply PCB Assy| 9707398052
106| Spacer| 0600118075
107| Reactor Assy| 9707457018
108| Clamp NK-4N| 313714328805
109| Terminal-3P| 9703345012
110| Room Thermistor| 9703299063
111| Control Box Cover| 9368524005
112| Wire Cover A| 9362789004

FUJITSU-AUYA36LATN-Split-Type-Air-Conditioner-FIG-
\(31\)

Ref.

No.

| Description| Parts number| Ord.

Q’ty

---|---|---|---
1| Top Panel Sub Assy| 9374417025|
2| Front Panel| 9374094028|
3| Fan Guard| 9374330010|
4| Grip Side| 9374173013|
5| Service Panel Sub Assy| 9374415069|
6| Right Panel Sub Assy| 9374416141|
7| Valve Cover| 9374174010|
—| Emblem Rear| 9351355005|

FUJITSU-AUYA36LATN-Split-Type-Air-Conditioner-FIG-
\(32\)

Ref. No. Description Parts number Ord. Q’ty
9 Propeller Fan Assy 9366378020
10 Motor DC Brushless 9601882015
11 Condenser A Assy 9374433018
12 Condenser B Assy 9374434015
13 Sepa Wall 9374629015
14 Cap Foot 9374345014
15 Base Assy 9374166046
16 Coil Choke 9703458019

FUJITSU-AUYA36LATN-Split-Type-Air-Conditioner-FIG-
\(33\)

Ref. No. Description Parts number Ord. Q’ty
17 3-Way Valve Assy 9377958013
18 3-Way Valve Assy 9377959010
19 Compressor Assy 9378035010
20 Accumulator Assy 9375250034
21 Solenoid 9900165055
22 Pressure Switch 9900186012
23 4-Way Valve 9970035029
24 Check Valve Assy 9374274017
25 Coil (Expansion Valve) 9900197025
26 Strainer Assy 9372524039
42 Expansion Valve Assy 9370947175
54 Compressor Cover A 9374430109
55 Compressor Cover B 9374431106
56 Compressor Cover C 9372067086
57 Compressor Cover D 9375382025
58 Solenoid 9900165055

FUJITSU-AUYA36LATN-Split-Type-Air-Conditioner-FIG-
\(34\)

Ref.| Description| Parts number|
---|---|---|---
27| Inverter Box A| 9374603015|
28| Inverter Box B| 9374625017
29| Inverter Box C| 9374605026
30| Inverter Box Duct| 9374609017
31| Inverter Box Cover| 9374608010
32| Heat Sink B| 9374607020
33| ACTPM| 9707592016
36| Posistor| 9704265012
37| Inverter PCB Assy (36)| 9707537024
37| Inverter PCB Assy (45)| 9707537017
38| Power PCB Assy| 9705647022
39| Clamp (Cord)| 9356857009
40| Terminal| 9900203023
41| Fuse (Small)| 0600376116
43| Thermistor (Dischage)| 9704219084
44| Thermistor (Heat Exchanger)| 9900374037
45| Thermistor (Out Temp)| 9900378035
46| Compressor Thermistor| 9900156060
47| Heatsink Thermistor| 9900311018
48| Wire (Pressure Switch)| 9367595051
50| Thermistor (Heat Exchanger)| 9900403010
51| Fuse Holder (Small)| 0501456016
52| Fuse Holder (Large)| 0501454012
53| Fuse (Large)| 0600086039

ACCESSORIES

INDOOR UNIT

FUJITSU-AUYA36LATN-Split-Type-Air-Conditioner-FIG-
\(35\)

OUTDOOR UNIT

Documents / Resources

| FUJITSU AUYA36LATN Split Type Air Conditioner [pdf] Installation Guide
AUYA36LATN Split Type Air Conditioner, AUYA36LATN, Split Type Air Conditioner, Type Air Conditioner, Air Conditioner, Conditioner
---|---

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

FUJITSU User Manuals

Related Manuals