FUJITSU ASYG24LFCC Split Type Room Air Conditioner Wall Mounted Type User Manual

October 30, 2023
FUJITSU

FUJITSU ASYG24LFCC Split Type Room Air Conditioner Wall Mounted Type

Product Information

Specifications

  • The ASYG24LFCC AOYG24LFCC is a cool and heat inverter type air conditioner with a cooling capacity of 7.10 kW and a heating capacity of 8.00 kW. It operates on a power source of 230 V and a frequency of 50 Hz. The running current for both cooling and heating is 9.7 A, with an input wattage of 2.20 kW for cooling and 2.21 kW for heating. The E.E.R. for cooling is 3.23 kW/kW, while for heating it is 3.61 kW/kW. The moisture removal capacity is 2.7 L/hr, and the maximum air circulation for high is 1,120 m3/hr. The maximum current for cooling is 13.5 A, and for heating, it is 18.5 A.
  • The fan motor power source is 230 V, and the motor has four speeds – high, medium, low, and quiet. The indoor unit (cool) fan motor has a speed of 1,480 r.p.m. at high speed, while the outdoor unit (cool) fan motor has a speed of 1,100 r.p.m. at high speed. The indoor unit (heat) fan motor has a speed of 1,220 r.p.m. at high speed, while the outdoor unit (heat) fan motor has a speed of 1,050 r.p.m. at high speed.
  • The noise level for the indoor unit (cool) is 49 dB at high speed, 42 dB at medium speed, and 37 dB at low and quiet speeds. The noise level for the indoor unit (heat) is 48 dB at high speed, 42 dB at medium speed, and 37 dB at low and quiet speeds. The noise level for the outdoor unit (cool) is 55 dB, while for the outdoor unit (heat) it is 56 dB.
  • The compressor and refrigerant type is hermetic type, 6 pole, rotary. The precharged refrigerant is R410A, with a full charge of 1,800 g and an additional charge of 2,100 g. The maximum height difference is 20 m, with a pipe length of 15 m and an additional refrigerant charge of 20 g/m.

Product Dimensions

  • The indoor unit has dimensions of 320 x 998 x 238 mm and weighs 18 kg for shipping and 14 kg for net weight. The outdoor unit has dimensions of 620 x 790 x 290 mm and weighs 45 kg for shipping and 41 kg for net weight.

Refrigerant System Diagram

The refrigerant system diagram includes components such as a pressure switch, muffler, 3-way valve, compressor, 4-way valve, sub-accumulator, heat exchanger (indoor unit), strainer, expansion valve, heat exchanger (outdoor unit), and cooling flow and heating flow. The refrigerant pipe diameter for liquid is 1/4 (6.35 mm), and for gas is 5/8 (15.88 mm).

Indoor Unit Circuit Diagram

  • The indoor unit circuit diagram includes components such as a fan motor, diffuser, and thermistors for pipe temperature and room temperature. It also includes an indicator PCB, wired remote control (option), and thermal fuse 102.

Product Usage Instructions

  1. Install the indoor and outdoor units according to the dimensions specified in the manual.
  2. Connect the refrigerant pipes according to the refrigerant system diagram.
  3. Connect the power source and frequency according to the specifications.
  4. Set the fan motor speed according to your preference using the wired remote control (optional).
  5. Set the temperature and mode (cooling or heating) using the wired remote control (optional).
  6. Monitor the noise level and adjust the fan motor speed and mode accordingly.
  7. Clean the air filters regularly to maintain optimum performance.
  8. In case of an error detection, refer to the error detection section in the manual and contact a qualified technician for assistance.

SPECIFICATIONS

ELECTRICAL DATA

TYPE Cool & heat inverter
INDOOR UNIT ASYG24LFCC
OUTDOOR UNIT AOYG24LFCC
COOLING CAPACITY 7.10 kW
HEATING CAPACITY 8.00 kW
POWER SOURCE 230 V
FREQUENCY 50 Hz
RUNNING CURRENT COOLING
HEATING 9.7 A

INPUT WATTS

| COOLING| 2.20 kW
HEATING| 2.21 kW
E.E.R.                     COOLING| 3.23 kW/kW
COP                       HEATING| 3.61 kW/kW
MOISTURE REMOVAL| 2.7 L/hr
AIR CIRCULATION HIGH| 1,120 m3/hr

MAXIMUM CURRENT

| COOLING| 13.5 A
HEATING| 18.5 A

FAN MOTOR

POWER SOURCE 230 V

INDOOR UNIT

(Cool)

| High| 1,480 r.p.m.
Medium| 1,220 r.p.m.
Low| 1,020 r.p.m.
Quiet| 860 r.p.m.

INDOOR UNIT

(Heat)

| High| 1,480 r.p.m.
Medium| 1,220 r.p.m.
Low| 1,020 r.p.m.
Quiet| 860 r.p.m.
OUTDOOR UNIT (Cool)| 1,100 r.p.m.
OUTDOOR UNIT (Heat)| 1,050 r.p.m.

NOISE LEVEL

INDOOR UNIT

(Cool)

| High| 49 dB
---|---|---
Medium| 42 dB
Low| 37 dB
Quiet| 32 dB

INDOOR UNIT

(Heat)

| High| 48 dB
Medium| 42 dB
Low| 37 dB
Quiet| 32 dB
OUTDOOR UNIT (Cool)| 55 dB
OUTDOOR UNIT (Heat)| 56 dB

COMPRESSOR AND REFRIGERANT

TYPE

| Hermetic type, 6 pole, Rotary
---|---
DISCRIMINATION| N-SF17ND1A
WEIGHT WITH OIL| 10.6 kg
PRECHARGED REFRIGERANT| 1,800 g
REFRIGERANT TYPE| R410A
Pipe length FULL CHARGE| 15 m| 1,800 g
30 m| 2,100 g
ADDITIONAL CHARGE| 20 g/m
MAXIMUM HEIGHT DIFFERENCE| 20 m

DIMENSIONS

INDOOR UNIT           H x W x D 320 x 998 x 238 mm
OUTDOOR UNIT       H x W x D 620 x 790 x 290 mm

WEIGHT

INDOOR UNIT     Shipping / Net 18 kg / 14 kg
OUTDOOR UNIT Shipping / Net 45 kg / 41 kg

DIMENSIONS

Unit: mm

INDOOR UNIT

  • Drain hose length: 670 mm
  • Drain hose diameter
  • Inside: 12 mm
  • Outside: 16 mm

OUTDOOR UNIT

DIAGRAMS

REFRIGERANT SYSTEM DIAGRAM

  • Cooling flow
  • Heating flow

Refrigerant pipe diameter

  • Liquid: 1/4″ (6.35 mm)
  • Gas: 5/8″ (15.88 mm)

CIRCUIT DIAGRAM

INDOOR PCB CIRCUIT DIAGRAM

INDOOR UNIT

  • MAIN PCB
  • K09DR-1207HSE-C1

INDOOR UNIT

  • INDICATOR PCB
  • K05CY-0902HSE-D0

OUTDOOR PCB CIRCUIT DIAGRAM

OUTDOOR UNIT

  • MAIN PCB
  • K11BS-1205HUE-C1

ERROR DETECTION

INDOOR UNIT and WIRED REMOTE CONTROL

  • If you use a wireless remote control, the lamp on the photo detector unit will output error codes by way of blinking patterns.
  • If you use a wired remote control, error codes will appear on the remote control display.
  • See the lamp blinking patterns and error codes in the table. An error display is displayed only during operation.

Troubleshooting with the wired remote control

  • If an error occurs, the following display will be shown.
  • (“Er” will appear in the set room temperature display.)
  1. : 0.5s on / 0.5s off
  2. : 0.1s on / 0.1s off
  3. ( ) : Number of flashing

PARTS

INDOOR UNIT

Ref Description Parts number
1 Front Panel Total Assy 9318738001
2 Front Panel 9314991080
3 Intake Grille Assy 9385985049
4 Air Filter 9315014016
5 Receiver Window 9315010018
6 Clamper Grille 9306755010
7 Wire Clamper 9315015013
8 Cap (Screw) 9309002074
9 Bracket Panel 9315023018
10 Remote Control 9379219037
11 Remote Control Holder 9305642045
Air Clean Filter Assy 9315212016
Ref Description Parts number
21 Evaporator Total Assy 9315338112
22 Connection Pipe Assy 9315355058
23 Water Seal 9315251015
24 Evaporator Holder R 9314994012
25 Evaporator Holder L 9314995019
26 Rear Bracket 9315022011
27 Filter Guide 9315013019
28 Filter Guard 9315411013
29 Bearing C Assy 9306628017
30 Crossflow Fan Assy 9315024015
31 Holder (Room Thermistor) 9315252012
32 Pipe Thermistor 9900551018
Ref Description Parts number
41 Casing Assy 9315331045
42 Casing 9314993015
43 Casing Cover B 9315016010
44 Casing Cover L 9315017017
45 Casing Cover R 9315018014
46 Casing Cover F 9315019011
47 Drain Cap 9367677009
48 Drain Hose Assy 9315769015
49 Bush B 9312156016
50 Spacer D 9315282019
51 Louver U 9315000026
--- --- ---
52 Louver Z 9315001023
53 Diffuser U 9315002020
54 Diffuser Z 9315003027
55 Spring C 9314142017
56 Piller A 9315009012
57 Joint B 9315006011
58 R and L Louver 9311997016
Fan Guard 9305751051
Fan Guard Holder Right 9315814012
Fan Guard Holder Left 9315815019
Ref Description Parts number
61 Control Box Cover 9314997013
62 Control Box 9314996016
63 Main PCB 9708540207
64 Terminal 9900447014
65 Terminal Earth 9315028020
66 Motor Case 9314998034
67 Fan Motor Assy 9602703012
68 Motor Step (Red) 9900384029
69 Motor Step (Green) 9900384036
70 Motor Step (Blue) 9900139063
71 Indicator PCB 9707210057
72 Clamper (Motor) 9315012012
73 Gear A 9309994003
74 Joint A 9315005014
75 Link A 9315008015
76 Link Holder 9315007018
Bush B 9312156016

OUTDOOR UNIT

Ref. Description Part number
1 Protective Net 9331640015
2 Top Panel Assy 9318464139
3 Front Panel Assy 9318463040
4 Cabinet Left Assy 9318461015
5 Cabinet Right Assy 9318462012
6 Grip 9317588003
7 Switch Cover Assy 9318499001
8 Motor Bracket Assy 9319124001
9 Fan Motor 9602724017
10 Propeller Fan 9313808013
11 Base Assy 9316885066
Emblem 9319151007
Drain Assy 9303029022
21 Shield Panel 9319542003
22 Inverter Case Assy 9319548012
23 PCB Holder 9319547015
24 Main PCB 9708996165
25 Heat Sink 9319540009
26 Terminal Bracket 9319543017
27 Terminal 6P 9900435028
Outdoor Thermistor 9900565008
Thermistor Assy 9900727017
Compressor Thermistor 9900777012
31 Condenser Total Assy 9317089166
32 Compressor 9810244000
33 2-way Valve Assy 9314554018
34 3-way Valve Sub Assy 9319098005
35 4-way Valve Assy 9319874012
36 Solenoid 9970110023
37 Pulse Motor Valve Assy 9314557019
38 Expansion Valve Coil 9970095030

ACCESSORIES

INDOOR UNIT

OUTDOOR UNIT

Documents / Resources

| FUJITSU ASYG24LFCC Split Type Room Air Conditioner Wall Mounted Type [pdf] User Manual
ASYG24LFCC, ASYG24LFCC Split Type Room Air Conditioner Wall Mounted Type, Split Type Room Air Conditioner Wall Mounted Type, Room Air Conditioner Wall Mounted Type, Conditioner Wall Mounted Type, Wall Mounted Type, Mounted Type, AOYG24LFCC
---|---

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

FUJITSU User Manuals

Related Manuals