SPECIFICATIONS
ELECTRICAL DATA
TYPE | Cool & heat inverter |
---|---|
INDOOR UNIT | ASYG07LMCA |
OUTDOOR UNIT | AOYG07LMCA |
COOLING CAPACITY | 2.00 kW |
HEATING CAPACITY | 3.00 kW |
POWER SOURCE | 230 V |
FREQUENCY | 50 Hz |
RUNNING CURRENT | Cooling |
Heating | 3.3 A |
INPUT WATTS | Cooling |
Heating | 0.77 kW |
EER Cooling | 4.30 kW/kW |
COP Heating | 3.90 kW/kW |
MOISTURE REMOVAL | 1.0 L/h |
AIR CIRCULATION HIGH | 750 m3/h |
MAXIMUM CURRENT | Cooling |
Heating | 7.5 A |
FAN MOTOR
POWER SOURCE | 230 V |
---|
INDOOR UNIT
Cooling
| High| 1,320 r.p.m.
Medium| 1,160 r.p.m.
Low| 930 r.p.m.
Quiet| 680 r.p.m.
INDOOR UNIT
Heating
| High| 1,320 r.p.m.
Medium| 1,160 r.p.m.
Low| 980 r.p.m.
Quiet| 710 r.p.m.
OUTDOOR UNIT
| Cooling| 730 r.p.m.| 860 r.p.m.
Heating| 650 r.p.m.| 760 r.p.m.
NOISE LEVEL
INDOOR UNIT
Cooling
| High| 43 dB
---|---|---
Medium| 40 dB
Low| 32 dB
Quiet| 21 dB
INDOOR UNIT
Heating
| High| 43 dB
Medium| 38 dB
Low| 33 dB
Quiet| 22 dB
OUTDOOR UNIT
| Cooling| 45 dB| 50 dB
Heating| 45 dB| 50 dB
COMPRESSOR AND REFRIGERANT
COMPRESSOR TYPE
| Hermetic type, 4 pole, 3 phase,
DC inverter motor, Rotary
---|---
DISCRIMINATION| 5SS072XHA01| ASM89D10UFZ
WEIGHT (with oil)| 6.0 kg| 8.9 kg
PRECHARGED REFRIGERANT| 700 g| 850 g
REFRIGERANT TYPE| R410A
Pipe length
FULL CHARGE
| 15 m| 700 g| 850 g
20 m| 800 g| 950 g
ADDITIONAL CHARGE| 20 g/m
MAXIMUM PIPING HEIGHT| 15 m
DIMENSIONS
INDOOR UNIT H x W x D | 268 x 840 x 203 mm |
---|---|
OUTDOOR UNIT H x W x D | 535 x 663 x 293 mm |
WEIGHT
INDOOR UNIT Net / Shipping | 8.5 kg / 10.5 kg |
---|---|
OUTDOOR UNIT Net / Shipping | 21 kg / 25 kg |
DIMENSIONS
INDOOR UNIT
REFRIGERANT SYSTEM DIAGRAM
CIRCUIT DIAGRAM
INDOOR PCB CIRCUIT DIAGRAM
INDOOR UNIT
MAIN PCB
ASYG07LMCA : K12JY-1202HSE-C2
ASYG09LMCA : K12JY-1200HSE-C1
ASYG12LMCA : K12JY-1201HSE-C1
INDOOR UNIT
INDICATOR PCB
K12JZ-1200HSE-D0
OUTDOOR PCB CIRCUIT DIAGRAM
INVERTER ASSEMBLY
AOYG07LMCA : EZ-0122CHUE
AOYG09LMCA : EZ-012PHUE
AOYG12LMCA : EZ-012RHUE
OUTDOOR UNIT
MAIN PCB
AOYG07LMCA : K12JX-1204HUE-C1
AOYG09LMCA : K12JX-1202HUE-C1
AOYG12LMCA : K12JX-1203HUE-C1
ERROR DETECTION
INDOOR UNIT
REMOTE CONTROL
If you use a wireless remote control, the lamp on the photo detector unit will
output error codes by way of blinking patterns.
If you use a wired remote control, error codes will appear on the remote
control display.
See the lamp blinking patterns and error codes in the table.
An error display is displayed only during operation.
: 0.5s ON / 0.5s OFF
: 0.1s ON / 0.1s OFF
( ) : Number of flashing
Indoor unit lamps| Wired remote control|
Description
---|---|---
OPERATION (green)| TIMER (orange)| ECONOMY (green)
(1)| (1)| | | Serial communication error
(1)| (2)| | | Wired remote control communication error
(1)| (5)| | | Check run unfinished
(3)| (2)| | | Indoor unit PCB model information error
(3)| (5)| | | Manual auto switch error
(4)| (1)| | | Room temp. sensor error
(4)| (2)| | | Indoor unit Heat Ex. Middle temp. sensor error
(5)| (1)| | | Indoor unit fan motor error
(5)| (3)| | | Drain pump error
(5)| (7)| | | Damper error
(5)| (8)| | | Intake grill error
(5)| (15)| | | Indoor unit error
(6)| (2)| | | Outdoor unit main PCB model information error or
communication error
(6)| (3)| ****| | Inverter error
(6)| (4)| | | Active filter error, PFC circuit error
(6)| (5)| | | Trip terminal L error
Wired remote control display (Option)
If an error occurs, the following display will be shown.
(“Er” will appear in the set room temperature display.)
Indoor unit lamps| Wired|
Description
---|---|---
OPERATION (green)| TIMER (orange)| ECONOMY (green)| remote control
(6)| (10)| | | Display PCB microcomputers communication error
(7)| (1)| | | Discharge temp. sensor error
(7)| (2)| | | Compressor temp. sensor error
(7)| (3)| | | Outdoor unit Heat Ex. liquid temp. sensor error
(7)| (4)| | | Outdoor temp. sensor error
(7)| (5)| | | Suction Gas temp. sensor error
(7)| (6)| | | • 2-way valve temp. sensor error
• 3-way valve temp. sensor error
(7)| (7)| | | Heat sink temp. sensor error
(8)| (2)| | | • Sub-cool Heat Ex. gas inlet temp. sensor error
• Sub-cool Heat Ex. gas outlet temp. sensor error
(8)| (3)| | | Liquid pipe temp. sensor error
(8)| (4)| | | Current sensor error
(8)| (6)| | | • Discharge pressure sensor error
• Suction pressure sensor error
• High pressure switch error
(9)| (4)| | | Trip detection
(9)| (5)| | | Compressor rotor position detection error (permanent stop)
(9)| (7)| | | Outdoor unit fan motor error
(9)| (9)| | | 4-way valve error
(10)| (1)| | | Discharge temp. error
(10)| (3)| | | Compressor temp. error
(10)| (4)| | | High pressure error
(10)| (5)| | | Low pressure error
(13)| (2)| | | Branch boxes error
PARTS
INDOOR UNIT
ASYG07LMCA
ASYG09LMCA
ASYG12LMCA
Ref. | Description | Part number |
---|---|---|
1 | Remote Control | 9319208008 |
2 | Remote Control Holder | 9318912005 |
3 | Bracket Panel | 9332882018 |
4 | Electric Filter Holder | 9332911008 |
5 | Air Clean Filter Assy | 9317250009 |
6 | Air Filter | 9332875003 |
7 | Front Panel Sub Assy (FUJITSU) | 9332994001 |
8 | Intake Grille (FUJITSU) | 9333052007 |
9 | Wire Cover | 9332894004 |
10 | Wire Shield | 9332906004 |
11 | Louver with Shaft cover | 9333353005 |
12 | Diffuser Assy | 9332998009 |
13 | Screw cap | 9309002081 |
Ref. | Description | Part number |
---|---|---|
21 | Cover Shield | 9332915006 |
22 | Control Box | 9332892000 |
23 | Box Shield Assy | 9332877007 |
24 | Main PCB (07) | 9709427033 |
24 | Main PCB (09) | 9709427019 |
24 | Main PCB (12) | 9709427026 |
25 | Terminal | 9900720001 |
26 | Earth Terminal | 9332880007 |
27 | Display Assy | 9709430019 |
28 | Room Thermistor Holder | 9332868005 |
— | Thermistor Assy | 9900714024 |
Ref. | Description | Part number |
---|---|---|
31 | Evaporator Total Assy | 9332989007 |
32 | Fan Motor | 9603269005 |
33 | Crossflow Fan Assy | 9316830004 |
34 | Bearing C Assy | 9306628017 |
35 | Casing Assy | 9333009001 |
Ref. | Description | Part number |
---|---|---|
41 | Casing | 9332890006 |
42 | Motor Holder L/R | 9332859003 |
43 | Cable Guide | 9332903003 |
44 | Casing Cover F | 9332909005 |
45 | Casing Cover B | 9332908008 |
46 | R and L Louver A | 9332891003 |
47 | Step Motor | 9900790004 |
48 | Step Motor | 9900790011 |
49 | Fan Guard | 9332905007 |
50 | Drain Cap | 9316177017 |
51 | Drain Hose Assy | 9316904002 |
OUTDOOR UNIT
Ref. | Description | Part number |
---|---|---|
1 | Protective Net | 9332855005 |
2 | Thermistor Holder | 9332505009 |
3 | Top Panel Assy | 9332977004 |
4 | Front Panel Assy | 9332965001 |
5 | Cabinet Left Assy | 9332962000 |
6 | Cabinet Right Assy | 9332963007 |
7 | Switch Cover A Assy | 9332964004 |
8 | Switch Cover B | 9332843002 |
9 | Fan Motor | 9603074043 |
10 | Propeller Fan | 9309909014 |
11 | Base Assy (07, 09) | 9332888003 |
11 | Base Assy (12) | 9332888010 |
12 | Drain Assy | 9332574005 |
— | Emblem | 9319151007 |
OUTDOOR UNIT
Ref. | Description | Part number |
---|---|---|
21 | Reactor Assy | 9900787028 |
22 | PCB Holder | 9332506006 |
23 | Main PCB with Terminal (07) | 9709435052 |
23 | Main PCB with Terminal (09) | 9709435038 |
23 | Main PCB with Terminal (12) | 9709435045 |
24 | Heat Sink B | 9332522006 |
— | Thermistor Assy | 9900719029 |
— | Thermistor | 9900717025 |
OUTDOOR UNIT
AOYG07LMCA
AOYG09LMCA
Ref. | Description | Part number |
---|---|---|
31 | Condenser Total Assy | 9332924008 |
32 | Compressor Assy | 9317083034 |
33 | Solenoid | 9970079030 |
34 | 4-way Valve Assy | 9333012001 |
35 | Expansion Valve Coil | 9970137013 |
36 | Pulse Motor Valve Sub Assy | 9333023007 |
OUTDOOR UNIT AOYG12LMCA
Ref. | Description | Part number |
---|---|---|
41 | Condenser Total Assy | 9333013008 |
42 | Compressor Assy | 9332603002 |
43 | Solenoid | 9970079030 |
44 | 4-way Valve Assy | 9333979007 |
45 | Expansion Valve Coil | 9970137013 |
46 | Pulse Motor Valve Sub Assy | 9333023007 |
ACCESSORIES
1302G4184
Documents / Resources
|
FUJITSU ASYG07LMCA Split Type Room Air Conditioner Wall Mounted
Type
[pdf] Owner's Manual
ASYG07LMCA, ASYG07LMCA Split Type Room Air Conditioner Wall Mounted Type,
Split Type Room Air Conditioner Wall Mounted Type, Air Conditioner Wall
Mounted Type, Wall Mounted Type, Mounted Type, AOYG07LMCA, ASYG09LMCA,
AOYG09LMCA, ASYG12LMCA, AOYG12LMCA
---|---
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>