FUJITSU ARYC45LCTU Split Type Air Conditioner Duct Type User Manual

October 30, 2023
FUJITSU

FUJITSU ARYC45LCTU Split Type Air Conditioner Duct Type

FUJITSU-ARYC45LCTU-Split-Type-Air-Conditioner-Duct-Type-
PRODUCT

Split Type Air Conditioner Duct Type (50Hz)
The Split Type Air Conditioner Duct Type (50Hz) comes with an indoor unit and an outdoor unit. The product specifications, dimensions, refrigerant system diagram, circuit diagram, indoor PCB circuit diagram, outdoor PCB circuit diagram, error detection, parts (indoor unit), parts (outdoor unit), and accessories are included in the manual.

Specifications

Type Indoor Unit Outdoor Unit
Cooling Capacity 12.5 kW (ARYC45LCTU), 14.0 kW (ARYC54LCTU) 14.0 kW

(AOYD45LATT), 16.0 kW (AOYD54LATT)
Heating Capacity| 14.0 kW (ARYC45LCTU), 16.0 kW (ARYC54LCTU)| 14.0 kW (AOYD45LATT), 16.0 kW (AOYD54LATT)
Power Source| 400 V 50 Hz 3 4 W| 400 V 50 Hz 3 4 W
Running Current| Cooling: 6.1 A (ARYC45LCTU), 6.9 A (ARYC54LCTU)
Heating: 5.5 A (ARYC45LCTU), 6.5 A (ARYC54LCTU)| Cooling: 4.65 kW (AOYD45LATT), 4.37 kW (AOYD54LATT)
Heating: 3.67 kW (AOYD45LATT), 4.37 kW (AOYD54LATT)
Input Watts| Cooling: 4.06 kW (ARYC45LCTU), 3.81 kW (ARYC54LCTU)
Heating: 3.08 kW (ARYC45LCTU), 3.66 kW (ARYC54LCTU)| Cooling: 3,450 g (AOYD45LATT), 4,200 g (AOYD54LATT)
Heating: 3,450 g (AOYD45LATT), 4,950 g (AOYD54LATT)
E.E.R.| Cooling: 3.08 kW/kW (ARYC45LCTU), 3.01 kW/kW (ARYC54LCTU)
Heating: 3.81 kW/kW (ARYC45LCTU), 3.66 kW/kW (ARYC54LCTU)|
Starting Current| Cooling & Heating: 10.0 A (ARYC45LCTU), 10.0 A
(ARYC54LCTU)| Cooling & Heating: 11.0 A (AOYD45LATT), 12.0 A
(AOYD54LATT)
Moisture Removal| 1.5 L/hr (ARYC45LCTU), 2.5 L/hr (ARYC54LCTU)|
Aircirculation Indoor| Cooling: 3,350 m3/h (ARYC45LCTU), 3,350 m3/h (ARYC54LCTU)
Heating: 6,900 m3/h (ARYC45LCTU), 6,900 m3/h (ARYC54LCTU)|
Aircirculation Cooling| | Cooling: 6,200 m3/h (AOYD45LATT), 6,900 m3/h (AOYD54LATT)
Air circulation Heating| | Heating: 6,900 m3/h (AOYD45LATT), 6,900 m3/h (AOYD54LATT)
Maximum Current| | Cooling & Heating: 11.0 A (AOYD45LATT), 12.0 A
(AOYD54LATT)

Dimensions
The indoor unit has a height of 400 mm, a width of 1,050 mm, and a depth of 500 mm. The outdoor unit has a height of 1,290 mm, a width of 900 mm, and a depth of 330 mm.

Refrigerant System Diagram
The refrigerant system diagram shows the components of the indoor and outdoor units, including the compressor, heat exchanger, pressure sensor, and thermistors.

Product Usage Instructions

  1. Ensure that the product is properly installed according to the installation instructions provided in the manual.
  2. Connect the product to a power source with a voltage of 400 V and frequency of 50 Hz.
  3. Turn on the product and select the desired mode (cooling or heating) using the remote control.
  4. Adjust the temperature setting using the remote control.
  5. To prevent malfunction, follow the recommended maximum pipe length and maximum pipe height for the product.
  6. Clean the air filters regularly to ensure optimal performance.
  7. If an error occurs, refer to the error detection section in the manual for troubleshooting steps.

SPECIFICATIONS

ELECTRICAL DATA

TYPE Cooling & Heating
INDOOR UNIT ARYC45LCTU
OUTDOOR UNIT AOYD45LATT
COOLING CAPACITY 12.5 kW
HEATING CAPACITY 14.0 kW
POWER SOURCE 400 V 50 Hz 3  4 W
RUNNING CURRENT Cooling
Heating 5.5 A

INPUT WATTS

| Cooling| 4.06 kW| 4.65 kW
Heating| 3.67 kW| 4.37 kW

E.E.R.

| Cooling| 3.08 kW/kW| 3.01 kW/kW
Heating| 3.81 kW/kW| 3.66 kW/kW
STARTING CURRENT| 10.0 A| 10.0 A
MOISTURE REMOVAL| 1.5 L/hr| 2.5 L/hr
AIRCIRCULATION INDOOR| 3,350 m3/h| 3,350 m3/h
AIRCIRCULATION OUTDOOR| Cooling| 6,900 m3/h| 6,900 m3/h
Heating| 6,200 m3/h| 6,900 m3/h
MAXIMUM CURRENT| 11.0 A| 12.0 A

FAN MOTOR

INDOOR UNIT

| Discrimination| MFA-60TTFS
---|---|---
High speed| 1,300 r.p.m.| 1,300 r.p.m.
Middle speed| 1,150 r.p.m.| 1,150 r.p.m.
Low speed| 1,000 r.p.m.| 1,000r.p.m.
OUTDOOR UNIT

(cool / heat)

| Discrimination| MFE-54TV
Upper fan| 900 / 780 r.p.m.| 900 / 850 r.p.m.
Lower fan| 800 / 750 r.p.m.| 800 / 850 r.p.m.

NOISE LEVEL

INDOOR UNIT

| High speed| 47 dB| 47 dB
---|---|---|---
Middle speed| 43 dB| 43 dB
Low speed| 40 dB| 40 dB
OUTDOOR UNIT| Cooling| 54 dB| 55 dB
Heating| 54 dB| 56 dB

Note : Static pressure : 100pa Duct length : Inlet 1m, Outlet 2m

DIMENSIONS

INDOOR UNIT       H x W x D 400 x 1,050 x 500 mm
OUTDOOR UNIT  H x W x D 1,290 x 900 x 330 mm

WEIGHT

INDOOR UNIT       Gross / Net 51 kg / 46 kg
OUTDOOR UNIT Gross / Net 117 kg / 107 kg

COMPRESSOR AND REFRIGERANT

TYPE

| Hermetic type, Inverter, 4 poles, 3 phase,

DC motor, Twin Rotary

---|---
DISCRIMINATION| 808 677 80
WEIGHT (with oil)| 25.6 kg
REFRIGERANT TYPE| R410A
PRECHARGED REFRIGERANT| 3,450 g
MAX PIPE LENGTH| 75 m
MAX PIPE HEIGHT| 30 m
Pipe length FULL CHARGE| 30 m| 3,450 g
45 m| 4,200 g
60 m| 4,950 g
75 m| 5,700 g
ADDITIONAL CHARGE| 50 g/m

OUTLINE AND DIMENSIONS

FUJITSU-ARYC45LCTU-Split-Type-Air-Conditioner-
Duct-Type-fig-1

FUJITSU-ARYC45LCTU-Split-Type-Air-Conditioner-Duct-Type-
fig-2

REFRIGERANT SYSTEM DIAGRAMFUJITSU-ARYC45LCTU-Split-Type-Air-Conditioner-
Duct-Type-fig-3

CIRCUIT DIAGRAMFUJITSU-ARYC45LCTU-Split-Type-Air-Conditioner-Duct-Type-
fig-4

INDOOR PCB CIRCUIT DIAGRAM

INDOOR PCB CIRCUIT DIAGRAMINDOOR PCB CIRCUIT DIAGRAM

FUJITSU-ARYC45LCTU-Split-Type-Air-Conditioner-Duct-Type-
fig-5

OUTDOOR PCB CIRCUIT DIAGRAM

INVERTER ASSEMBLY AOYD45LATT : EZ-0071HUE AOYD54LATT : EZ-0072HUEFUJITSU-
ARYC45LCTU-Split-Type-Air-Conditioner-Duct-Type-fig-6

FUJITSU-ARYC45LCTU-Split-Type-Air-Conditioner-Duct-Type-
fig-7

FUJITSU-ARYC45LCTU-Split-Type-Air-Conditioner-Duct-Type-
fig-8

FUJITSU-ARYC45LCTU-Split-Type-Air-Conditioner-Duct-Type-
fig-9

FUJITSU-ARYC45LCTU-Split-Type-Air-Conditioner-Duct-Type-
fig-10

FUJITSU-ARYC45LCTU-Split-Type-Air-Conditioner-Duct-Type-
fig-11

FUJITSU-ARYC45LCTU-Split-Type-Air-Conditioner-Duct-Type-
fig-12

ERROR DETECTION

  • REMOTE CONTROL Troubleshooting at the remote control LCD This is possible only on the wired remote control.
  • Self-diagnosis If an error occurs, the following display will be shown.(“EE” will appear in the set room temperature display.)

FUJITSU-ARYC45LCTU-Split-Type-Air-Conditioner-Duct-Type-
fig-13

  • If “CO” appears in the unit number display, there is a remote control error. Refer to the installation instruction sheet included with the remote control.
Error code Error contents

01

13

26

27

|

Indoor signal error

00| Wired remote controller abnormal
02| Indoor room temperature sensor error
04| Indoor heat exchanger temperature sensor (middle) error
28| Indoor heat exchanger temperature sensor (inlet) error
09| Float switch operated
0c| Outdoor discharge pipe temperature sensor error
06| Outdoor heat exchanger temperature sensor (outlet) error
0A| Outdoor temperature sensor error
0E| Heat sink thermistor (Inverter) error
15| Compressor temperature sensor error
1d| 2-way valve temperature sensor error
1E| 3-way valve temperature sensor error
29| Outdoor heat exchanger temperature sensor (middle) error
2d| Heat sink thermistor (P.F.C.) error
20| Indoor manual auto switch abnormal
2A| Power supply frequency detection error
17| IPM protection
18| CT error
1A| Compressor location error
1b| Outdoor fan error
1F| Connected indoor unit abnormal
1c| Outdoor unit computer communication error
2E| Inverter error
12| Indoor fan abnormal
0F| Discharge temperature error
24| Excessive high pressure protection on cooling
2c| 4-way valve abnormal
16| Pressure switch abnormal, Pressure sensor abnormal
2b| Compressor temperature error
2F| Low pressure error
19| Active filter abnormal
25| P.F.C. circuit error
30| Refrigerant circuit address set-up error
31| Master unit, Slave unit set-up error
32| Connected the indoor number set-up error
33| P.F.C. PCB error

OUTDOOR UNIT TEST RUN
CAUTION: Always turn on the power 6 hours prior to the start of the operation in order to protect the compressor. Check items before performing the test run Make sure to perform the test run. Before performing the test run, be sure to check the following points.

  1. Is gas leaking? Check connection of each pipe (flare connection part, brazing part).
  2. Is a breaker installed to the power cable of the outdoor unit ?
  3. Has each cable been securely connected to the terminal according to the specifications ?
  4. Are the 3-way valves (gas pipes and liquid pipes) of the outdoor units open?
  5. Has the power been supplied to the unit for at least 6 hours ?
  6. Has the necessary local setting been done ?
  7. Check insulation resistance of 1 M or more using a 500V mega tester. If no problems are found with the above items, perform the test run according to “Test run method”. If any problems are found, immediately resolve the problem and re-check the items.

Test run method
CAUTION: If the test run is performed for 1 outdoor unit in a group control system installation, the test run will also be performed for the other units. Therefore, make sure that all of the units have been installed before starting a test run. (Group control system installation described in “SPECIAL INSTALLATION METHODS” in the installation manual of the indoor unit.) Operate [ENTER] (TEST RUN) switch on the display board by the following procedure .FUJITSU-ARYC45LCTU-Split-Type-Air-Conditioner-Duct-Type-
fig-15

Operating procedures for the test run

  1. Check the 3-way valves (both at the liquid side and gas side) are opened.
  2. Set the operation mode to “COOL” or “HEAT”.
    POWER|

ERROR

| TEST RUN

(L1)

| PUMP DOWN

(L2)

| LOW NOISE (L3)      (L4)| PEAK CUT

(L5)     (L6)  (L7)

---|---|---|---|---|---
MODE
| | | | | | | |

Sign   lights on.
In the first test run, be sure to set the operation mode to “COOL”. The operation mode cannot be switched between “COOL” and “HEAT” during the test run. To switch the operation mode between “COOL” and “HEAT”, stop the test run, switch the operation mode, and then start the test run again.

  1. Press [ENTER] (TEST RUN) switch for more than 3 seconds.
    POWER|

ERROR

| TEST RUN

(L1)

| PUMP DOWN

(L2)

| LOW NOISE (L3)      (L4)| PEAK CUT

(L5)     (L6)  (L7)

---|---|---|---|---|---
MODE
| | | | | | | |

“TEST RUN” LED will light on.
If the compressor is operating at starting the test run, the compressor will stop and, after a while, the test run will start. Either of the above “LOW NOISE” or “PEAK CUT” will light on during the test run if local setting function is selected.

  1. Confirm operating status.
  2. Press [ENTER] (TEST RUN) switch again.
    POWER|

ERROR

| TEST RUN

(L1)

| PUMP DOWN

(L2)

| LOW NOISE (L3)      (L4)| PEAK CUT

(L5)     (L6)  (L7)

---|---|---|---|---|---
MODE
| | | | | | | |

“TEST RUN” LED lights off, and TEST RUN stops.
Test run will finish after about 60 minutes automatically. At the same time, “TEST RUN” LED will light off. Test run may be stopped before operating for 60 minutes if an error occurs after a starting test run.

OUTDOOR UNIT ERROR CODE DISPLAY
When an error occurs, “short-press” the [ENTER] switch once. The number of blinks of the LED indicates the type of error. How to check error code?

  • Display when an error occurs
    POWER|

ERROR

| TEST RUN (L1)| PUMP DOWN (L2)| LOW NOISE (L3)     (L4)| PEAK CUT

(L5)     (L6)     (L7)

---|---|---|---|---|---
MODE
| Blinks

(Hi-speed)

| | | | | | |

  • Check that the “ERROR” LED blinks, and then “short- press” the [ENTER] switch once.
  •  Display while an error code is blinking
    POWER|

ERROR

| TEST RUN (L1)| PUMP DOWN (L2)| LOW NOISE (L3)     (L4)| PEAK CUT

(L5)     (L6)     (L7)

---|---|---|---|---|---
MODE
Blinks (Twice)| Blinks| | | | | | |

  • The “POWER MODE” LED will blink twice and the “ERROR” LED will blink several times. The number of blinks of the “ERROR” LED varies according to the type of error. For details, refer to the right table.

Error code check table

Number of blinks (LED) Error type
1 Serial forward transfer error
2 Discharge thermistor error
3 Heat-exchange thermistor (outlet) error
4 External temperature thermistor error
5 Heat-exchange thermistor (intermediate) error
6 Discharge temperature protection (permanent stoppage)
7 Compressor thermistor error
8 Heatsink thermistor (inverter) error
9 Pressure switch (sensor) error
10 Compressor temperature protection (permanent stoppage)
11 Connection with indoor unit error
12 Current trip (permanent stoppage)
13 Detection of compressor position error (permanent stoppage)
14 Compressor start up error (permanent stoppage)
15 Fan motor (1) error (permanent stoppage)
16 Fan motor (2) error (permanent stoppage)
17 Heatsink thermistor (P.F.C.) error
18 Inverter error
19 P.F.C. error
20 Low pressure abnormal
21 Indoor unit abnormality condition

SPECIAL INSTALLATION  SETTING
OUTDOOR UNIT   PUMP DOWN (Refrigerant collecting operation) Perform the following procedures to collect the refrigerant when moving the indoor unit or outdoor unit

WARNING: Never touch electrical components such as the terminal blocks or reactor except the switch on the display board. It may cause a serious accident such as electric shock.

CAUTION

  • Perform the pump down operation before disconnecting any refrigerant pipe or electric cable.
  • Collect refrigerant from the service port or the 3-way valve if pump down cannot be performed.
  • In case of a group control system installation, do not turn the power off pump down is completed in all outdoor units.
  • (Group control system installation described in “SPECIAL INSTALLATION METHODS” in the installation manual of the indoor unit.)
  • Operate [PUMP DOWN] switch on the display board in the manner described below.FUJITSU-ARYC45LCTU-Split-Type-Air-Conditioner-Duct-Type-fig-16FUJITSU-ARYC45LCTU-Split-Type-Air-Conditioner-Duct-Type-fig-17

Preparation for pump down
Confirm that the power is off, and then open the service panel.

Pump down procedure

  1. Check the 3-way valves (both at the liquid side and gas side) are opened.
  2. Turn the power on.
    POWER|

ERROR

| TEST RUN

(L1)

| PUMP DOWN

(L2)

| LOW NOISE (L3)  (L4)| PEAK CUT

(L5)  (L6)  (L7)

---|---|---|---|---|---
MODE
| | | | | | | |
3. Press [PUMP DOWN] switch for 3 seconds or more after 3 minutes after power on.
POWER|

ERROR

| TEST RUN (L1)| PUMP DOWN (L2)| LOW NOISE (L3) (L4)| PEAK CUT

(L5)  (L6)  (L7)

---|---|---|---|---|---
MODE
| | | | | | | |

LED display lights on as shown in the above figure, and the fans and the compressor start operating. If the [PUMP DOWN] switch is pressed while the compressor is operating, the compressor will stop, then start again in about 3 minutes.

  1. LED display will change as shown below about 3 minutes after the compressor starts. Fully close the 3- way valve on the liquid pipe side at this stage.
    POWER|

ERROR

| TEST RUN (L1)| PUMP DOWN (L2)| LOW NOISE (L3) (L4)| PEAK CUT

(L5)  (L6)  (L7)

---|---|---|---|---|---
MODE
| | | | | | | |

If the valve on the liquid pipe side is not closed, the pump down cannot be performed.

  1. When LED display changes as shown in the below figure, close the 3-way valve on the gas pipe side tightly.
    POWER|

ERROR

| TEST RUN (L1)| PUMP DOWN (L2)| LOW NOISE (L3) (L4)| PEAK CUT

(L5)  (L6)  (L7)

---|---|---|---|---|---
MODE
| | | | | | | |

If the valve on the gas pipe side is not closed, refrigerant may flow into the piping after the compressor stopsFUJITSU-ARYC45LCTU-Split-Type-Air-
Conditioner-Duct-Type-fig-18

  1. LED display changes after 1 minute as shown in the figure below
    POWER|

ERROR

| TEST RUN

(L1)

| PUMP DOWN

(L2)

| LOW NOISE (L3) (L4)| PEAK CUT

(L5)  (L6)  (L7)

---|---|---|---|---|---
MODE
 |  |  |  |  |  |  |  |

Fans and compressor stop automatically. If the pump down is successfully completed (the above LED display is shown), the outdoor unit remains stopped until the power is turned off.

  1. Turn the power off.
    POWER|

ERROR

| TEST RUN

(L1)

| PUMP DOWN

(L2)

| LOW NOISE (L3) (L4)| PEAK CUT

(L5)  (L6)  (L7)

---|---|---|---|---|---
MODE
 |  |  |  |  |  |  |  |

PUMP DOWN is completed. Note : To stop pump down, press the [PUMP DOWN] switch again. To start the pump down again after the compressor is automatically stopped due to an error, turn the power off and open the 3-way valves. Wait 3 minutes, turn the power on and start the pump down again. When starting the operation after completion of the pump down, turn the power off, and then open the 3-way valves. Wait 3 minutes, turn the power on and perform a test run in the “COOL” operation mode.FUJITSU-ARYC45LCTU-Split-Type-Air-
Conditioner-Duct-Type-fig-19

Ref.| Description| Parts number|
---|---|---|---
1| Plate Top Sub Assy| 9372576014|
2| Kit (Panel Front Sub Assy)| 9372637029
3| Panel Fan Assy| 9372035009
4| Bracket Motor Assy| 9372037003
5| Motor, Induct| 9602802012
6| Casing A| 9372057018
7| Casing B| 9372058015
8| Sirocco Fan| 9372059012
9| Kit (Panel Rear Sub Assy)| 9372636022
10| Room Thermistor| 9703299216
11| Evaporator Assy| 9373875017
12| Pipe Thermistor| 9703297113
13| Drain Pan Assy| 9372579015
14| Kit (Panel Right Sub Assy)| 9372916025
15| Kit (Panel Left Sub Assy)| 9372581018
16| Drain Pan Sub Assy| 9372582015
17| Cover Box| 9372061008

FUJITSU-ARYC45LCTU-Split-Type-Air-Conditioner-Duct-Type-
fig-21

Ref.| Description| Parts number|
---|---|---|---
21| Control Box Assy| 9374854028|
22| Power Supply PCB Assy| 9705668102
23| Controller PCB Assy (45)| 9705246232
 | (K03BZ-0802HSE-C1)|
23| Controller PCB Assy (54)| 9705246225
 | (K03BZ-0801HSE-C1)|
24| Transformer (Power)| 9704129017
25| Terminal 3P| 9703345012
26| Terminal 3P| 9306489045
27| Relay| 9900294014
28| Fuse Holder| 0501454012
29| Fuse| 0600384029
30| Capacitor, Plastic| 9900269111
31| Capacitor Clamp| 9308114006
—| Thermo. Spring A| 313728262708
—| Remote Control| 9372266199

FUJITSU-ARYC45LCTU-Split-Type-Air-Conditioner-Duct-Type-
fig-22

Ref. Description Parts number
1 Top Panel Sub Assy 9374417032
2 Front Panel 9374094028
3 Fan Guard 9374330010
4 Grip Side 9374173013
5 Sevice Panel Sub Assy 9374415076
6 Pipe Cover Front 9378861015
7 Right Panel Sub Assy 9374416158
8 Pipe Cover Rear 9378862012
9 Fan Guard Cover 9378111011
Emblem Rear 9351355005
Protective Net 9375381042

FUJITSU-ARYC45LCTU-Split-Type-Air-Conditioner-Duct-Type-
fig-23

Ref. Description Parts number
11 Motor DC Brushless 9602749010
12 Propeller Fan Assy 9366378020
13 Motor Bracket Sub Assy 9374418145
14 Separate Wall Sub Assy 9374413195
15 Reactor Assy 9900246013
16 Reactor Holder Sub Assy 9379067003
17 Base Assy 9374166220
18 Valve Plate 9378804012
19 Compressor Cover A 9378611023
20 Compressor Cover B 9378612020
21 Condenser A Assy 9374433018
22 Condenser B Assy 9374434015

FUJITSU-ARYC45LCTU-Split-Type-Air-Conditioner-Duct-Type-
fig-24

Ref. Description Parts number
31 Coil (Expansion Valve) 9900190057
32 Expansion Valve Assy 9370947182
33 4-way Valve Assy 9374425167
34 Solenoid 9970055041
35 Accumulator 9379014014
36 3-way Valve Assy 9379079006
37 3-way Valve Assy 9379077002
38 Compressor Assy 9379013017
39 Accumulator Holder 9378800014
40 Comp Plate Assy 9378826014
41 Strainer Assy 9372524039
42 Sensor 9900505011

FUJITSU-ARYC45LCTU-Split-Type-Air-Conditioner-Duct-Type-
fig-25

Ref. Description Parts number
51 Main PCB Assy (45) 9707627022
51 Main PCB Assy (54) 9707627039
52 Filter PCB Assy 9707609011
53 PFC PCB Assy 9707629019
54 Capacitor PCB Assy 9707608014
55 Inverter PCB Assy 9707628012
56 Reactor Assy 9900481018
57 Terminal 9900428082
58 Compressor Thermistor 9900516000
59 Thermistor (Discharge) 9900515003
60 Thermistor (Heat Exchanger Med) 9900513009
61 Thermistor (Heat Exchanger Out) 9900514006
62 Thermistor (Outdoor) 9900517007
63 Heatsink Thermistor (Inverter) 9900518011
64 Heatsink Thermistor (PFC) 9900518028

ACCESSORIES

INDOOR UNIT

FUJITSU-ARYC45LCTU-Split-Type-Air-Conditioner-Duct-Type-
fig-26

OUTDOOR UNITFUJITSU-ARYC45LCTU-Split-Type-Air-Conditioner-Duct-Type-
fig-26

Documents / Resources

| FUJITSU ARYC45LCTU Split Type Air Conditioner Duct Type [pdf] User Manual
ARYC45LCTU, ARYC54LCTU, AOYD45LATT, AOYD54LATT, ARYC45LCTU Split Type Air Conditioner Duct Type, Split Type Air Conditioner Duct Type, Air Conditioner Duct Type, Conditioner Duct Type
---|---

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

FUJITSU User Manuals

Related Manuals