FUJITSU AUY12LBAB Inverter Multi Air Conditioner Cassette Type User Manual

October 30, 2023
FUJITSU

INVERTER MULTI
AIR CONDITIONER
CASSETTE TYPEFUJITSU AUY12LBAB Inverter Multi Air Conditioner Cassette
Type - OUTDOOR UNIT FUJITSU GENERAL LIMITED

SPECIFICATIONS

INDOOR UNIT
ELECTRICAL DATA

TYPE COOL & HEAT
MODEL NAME AUY12LBAB
COOLING CAPACITY 3.3 kW
HEATING CAPACITY 3.7 kW
MOISTURE REMOVAL 1.2 L/hr
AIR CIRCULATION HIGH 550 m3/hr

FAN MOTOR

POWER SOURCE 230 V
DISCRIMINATION MFA-14GTCT
HIGH 730 r.p.m.
MIDDLE 670 r.p.m.
LOW 590 r.p.m.

NOISE LEVEL

HIGH 42 dB
MIDDLE 39 dB
LOW 36 dB

DIMENSIONS

INDOOR UNIT       H x W x D 235 x 580 x 580+70 mm
GRILL                   H x W x D 35 x 650 x 650 mm

WEIGHT

INDOOR UNIT     Gross / Net 23 kg  / 18 kg
GRILL                 Gross / Net 4.3 kg  / 2.2 kg

OUTDOOR UNIT
ELECTRICAL SPECIFICATIONS

TYPE Cooling & heating multi
MODEL NAME AOY18LMAK2
COOLING CAPACITY 5.5 kW
HEATING CAPACITY 6.3 kW
POWER SUPPLY 230 V
FREQUENCY 50 Hz

RUNNING CURRENT

| Cooling| 7.3 A| 7.6 A
Heating| 7.3 A| 7.2 A

INPUT

| Cooling| 1.65 kW| 1.73 kW
Heating| 1.65 kW| 1.64 kW

EER

| Cooling| 3.33 kW/kW| 3.35 kW/kW
Heating| 3.82 kW/kW| 3.90 kW/kW
AIR CIRCULATION HIGH| 2,800 m3/hr| 2,800 m3/hr
MAX CURRENT| 10.5 A| 12.5 A

FAN MOTOR

DISCRIMINATION MFB24JTAT
HIGH SPEED (COOL) 780 r.p.m.
HIGH SPEED (HEAT) 780 r.p.m.

NOISE LEVEL

COOL 49 dB(A)
HEAT 50 dB(A)

MEASUREMENT

DIMENSIONS                 H x W x D 650 x 830 x 320 mm
WEIGHT                       Net / Gross 56 kg  / 62 kg

COMPRESSOR AND REFRIGERANT

COMPRESSOR TYPE| Hermetic type, Inverter, 4 poles, 3-phase, DC motor, Twin Rotary
---|---
DISCRIMINATION| TNB220FPCMT
WEIGHT (with oil)| 14.1 kg
STANDARD REFRIGERANT| 1,900 g
REFRIGERANT TYPE| R410A
ADDITIONAL CHARGE| Chargeless
MAX PIPE LENGTH (each unit)| 20 m
MAX PIPE LENGTH (total)| 30 m
MIN. PIPE LENGTH (each unit)| 5 m
MIN. PIPE LENGTH (total)| 10 m
MAX ELEVATION (between indoor units)| 10 m
MAX ELEVATION (between indoor and outdoor)| 10 m

**OUTLINE AND DIMENSIONS

**

INDOOR UNIT
(unit : mm)

FUJITSU AUY12LBAB Inverter Multi Air Conditioner Cassette Type -
DIMENSIONS

OUTDOOR UNIT
Unit : mm

FUJITSU AUY12LBAB Inverter Multi Air Conditioner Cassette Type - DIMENSIONS
1

REFRIGERANT
SYSTEM DIAGRAM

FUJITSU AUY12LBAB Inverter Multi Air Conditioner Cassette Type - SYSTEM
DIAGRAM1

REFRIGERANT
SYSTEM DIAGRAM

FUJITSU AUY12LBAB Inverter Multi Air Conditioner Cassette Type - SYSTEM
DIAGRAM 5

OUTDOOR UNIT

FUJITSU AUY12LBAB Inverter Multi Air Conditioner Cassette Type - OUTDOOR
UNIT

INDOOR PCB CIRCUIT DIAGRAM

FUJITSU AUY12LBAB Inverter Multi Air Conditioner Cassette Type - INDOOR PCB
CIRCUIT DIAGRAM

OUTDOOR PCB CIRCUIT DIAGRAM
CONTROLLER PCB ASSEMBLY
AOY18LMAK2 : K06DY-0602HUE-C1
AOY24LMAM2 : K06DY-0600HUE-C1
FUJITSU AUY12LBAB Inverter Multi Air Conditioner Cassette Type -
PCB

ERROR CONTENTS

Operation can be checked by lighting and flashing of the grille display section OPERATION and TIMER lamps.
Perform judgment in accordance with the following.FUJITSU AUY12LBAB Inverter
Multi Air Conditioner Cassette Type - accordance

TEST RUNNING
When the air conditioner is run by pressing the remote control unit test run button, the OPERATION and TIMER lamps flash slowly at the same time.
CHECK ITEMS
INDOOR UNIT

  1. Is operation of each button on the remote control unit normal?
  2.  Does each lamp light normally?
  3. Do not air flow direction louvers operate normally?
  4.  Is the drain normal?
  5.  Is there any abnormal noise and vibration during operation?
Error display Error contents
OPERATION lamp TIMER lamp

Blinks

|

Blinks

|

Goes off

| Indoor unit Model information abnormal (permanent type)
Pulses 4 times|

Blinks

|

Goes off

|

Indoor unit Drain abnormal (permanent type)

Pulses 6 times|

Blinks

|

Goes off

|

Indoor fan abnormal

Pulses 2 times| Blinks|

Goes off

|

Room air temperature thermistor open circuit

Blinks

|

Room air temperature thermistor short circuit

Pulses 3 times| Blinks|

Goes off

|

Indoor unit Piping thermistor open circuit

Blinks

|

Indoor unit Piping thermistor short circuit

Pulses 5 times|

Blinks

|

Goes off

| Outdoor unit circuit board error or miswiring between outdoor unit and indoor unit

Blinks

| Pulses 5 times|

Goes off

|

Outdoor unit discharge temperature sensor error

Blinks

| Pulses 3 times|

Goes off

|

Outdoor unit piping sensor error

Blinks

| Pulses 4 times|

Goes off

| Outdoor unit outdoor unit temperature sensor error

OUTDOOR UNIT

LED Condition
1 flash Communication abnormal
2 flashes Discharge pipe thermistor abnormal
3 flashes Heat exchanger thermistor abnormal
4 flashes Outdoor air thermistor abnormal
5 flashes 2-way valve (A, B) thermistor abnormal
6 flashes 3-way valve (A, B) thermistor abnormal
7 flashes Compressor thermistor abnormal
8 flashes Pressure switch abnormal
9 flashes Indoor units connection abnormal
10 flashes Current trip (permanent stop)
11 flashes CT abonormal (permanent stop)
12 flashes Compressor location detection abormal (permanent stop)
13 flashes Compressor does not start (permanent stop)
14 flashes Timer reduction

PARTS

INDOOR UNITS

FUJITSU AUY12LBAB Inverter Multi Air Conditioner Cassette Type - INDOOR
UNITSFUJITSU
AUY12LBAB Inverter Multi Air Conditioner Cassette Type - IINDOOR
UNIT

PANEL
UTG-UDYD-W
FUJITSU AUY12LBAB Inverter Multi Air Conditioner Cassette Type -
IPANEL PARTS LIST
INDOOR UNIT

Ref.

|

Description

| Part Number|
---|---|---|---
AUY12LBAB| AUY14LBAB
34| Capacitor (Fan Motor)| 9704305046| 9704305046|
67| Rubber| 9361279001| 9361279001
117-3| Special Washer M6| 313306391007| 313306391007
127| Drain Hose| 9359659013| 9359659013
138| Separate Wall-A| 9359647003| 9359647003
146| Evaporator Assy-IN| 9373214014| 9373214014
160| Drain Pan| 9359651000| 9359651000
164| Fan Motor Assy-IN| 9601040064| 9601040064
184-1| Thermo. Spring-A| 313728262708| 313728262708
185| Rubber Bushing| 313005066051| 313005066051
187| Clamp No. 1219| 313361271706| 313361271706
196| Clamp SKB-150| 313035356905| 313035356905
223| Control Box| 9359661016| 9359661016
234| Thermistor Assy-Room| 9703299032| 9703299032
235| Thermistor Assy-Pipe| 9703297014| 9703297014
236| Controller PCB Assy| 9704557933| 9704557940
240| Remote Control Unit| 9371190037| 9371190037
244| Pipe Cover| 9359646006| 9359646006
287| Cap (Power)| 9352173011| 9352173011
301| Clamp NK-2N| 313985355201| 313985355201
313| Hooking Wire| 9359983002| 9359983002
338| Motor Fixture| 9359656005| 9359656005
381| Locking Spacer| 313209391506| 313209391506
395| Supporter (Eva. )| 9373179016| 9373179016
399| Air Duct| 9359660002| 9359660002
411| Supporter-A| 9359655008| 9359655008
430| Clamp NK-7N| 313095365602| 313095365602
457| Drain Pan Support| 9359652007| 9359652007
462| Top Cover Plate| 9359642015| 9359642015
464| Body-A| 9359643005| 9359643005
465| Body-B| 9359645009| 9359645009
467| Drain Port| 313005415658| 313005415658
468| Special Nut-A (Large)| 313005446653| 313005446653
469| Special Nut-B (Small)| 313005446759| 313005446759
470| Separate Wall-B| 9359648000| 9359648000
474| Turbo Fan| 9359658009| 9359658009
475| Turbo Fan Rubber| 9366013006| 9366013006
476-1| Special Nut M8| 313005360755| 313005360755
476-2| Special Washer| 301801185049| 301801185049
476-3| Special Washer| 9359954002| 9359954002
478| Sensor M. Bracket| 9359654001| 9359654001
479| Float Switch| 313005416154| 313005416154
482| Pump Unit| 9359974000| 9359974000
484| Hanger Metal| 9359644002| 9359644002
488| Drain Pan Plug| 9359653004| 9359653004
495| Clamp No. 2U46| 9352715006| 9352715006
514| Control Box Cover| 9359662006| 9359662006
628| Locking Spacer-B| 313005446558| 313005446558
629| EMI Filter| 0400197119| 0400197119
652-1| Therm. Holder Pipe| 313806262805| 313806262805
743| Remote Control Holder| 9305642014| 9305642014
797| Separate Wall-C| 9359649007| 9359649007
798| Pump Hook Bracket| 9359650003| 9359650003
815| Terminal-3P| 9900203016| 9900203016
824-3| Fuse| 0600222512| 0600222512
834| Wire Cover| 9359878001| 9359878001
835| Cushion-A (For Pump)| 9352211003| 9352211003
836| Cushion-B (For Pump)| 9356084016| 9356084016
875| Filter PCB Assy| 9704561213| 9704561213
964| Flare Nut-1/2| —–| 9373267010
965| Flare Nut-B| 9351062019| 9351062019
989-1| Cord Clamp-A| 9359822011| 9359822011
989-2| Cord Clamp-B| 9359823018| 9359823018
990| Distributor Assy| 9373034049| 9373034049

GRILLE ASSY (UTG-UDYD-W)

Ref.| Description| Part Number|
---|---|---|---
93| Filter| 9359632009|
165| Motor Cover| 9359623014
196| Clamp SKB-150| 313035356905
226| Motor Gear| 9359629009
385| Indicator PCB Assy| 9702224011
392| Cover-A| 9359622017
416| Insulation (Panel)-A| 9359620006
417| Insulation (Panel)-B| 9359621003
690| Joint-A| 9359626008
691| Joint-B| 9359627005
692| Joint Shaft| 9359625001
694| Cam Gear| 9359628002
700| Panel| 9359619017
705| Louver| 9359624011
710| Intake Grille| 9370126006
711-1| Filter Clamp-A| 9359634003
711-2| Filter Clamp-B| 9359635000
758| Decoration Plate-A| 9360039019
763| Receiver Cover| 9359630005
776| Grille Stopper| 9359633013
777| Grille Hook| 9359761006
876-2| Step Motor-V| 9360307019

PARTS
OUTDOOR UNIT
![FUJITSU AUY12LBAB Inverter Multi Air Conditioner Cassette Type

Ref.| Description| Part number|
---|---|---|---
1| Top Panel| 9371925011|
2| Protective Net| 9371934013
3| Front Panel| 9371924014
4| Fan Guard| 9371187013
5| Emblem| 9351355005
6| Side Panel L| 9371926018
7| Side Panel R Sub Assy| 9372306048
8| Connecteor Cover| 9366398004
9| Valve Cover| 9372796016
10| Propeller Fan Assy| 9366378013

OUTDOOR UNIT

Ref.| Description| Part number|
---|---|---|---
11| Control Cover| 9372792018|
12| Controller PCB Assy (18LMAK2)| 9707560039
12| Controller PCB Assy (24LMAM2)| 9707560015
13| Motor Induct| 9601671046
14| Motor Bracket Top| 9371931012
15| Motor Bracket| 9371929019
16| Motor Bracket Center| 9371930015
17| Motor Bracket Bottom| 9371932019
18| Base Assy| 9371920078
19| Condenser Assy| 9372181096
20| Separate Wall| 9372795019
21| Valve Plate| 9371928036
22| 2-Way Valve| 9372204054
23| 3-Way Valve| 9372205044
24| 3-Way Valve| 9372205051
Ref.| Description| Part number|
---|---|---|---
—| Heat Exchanger Thermistor| 9704220059|
—| Thermistor Outdoor| 9703516047
—| Thermistor Heat Sink| 9900195014
—| Relay| 9900117016
—| ACTPM| 9703457012
—| Capacitor for PCB| 9705387010
—| Fan Capacitor| 9900270049
—| Fuse| 0600086039
—| Terminal 8P| 9900203047
—| Fuse Holder| 0501454012
—| Terminal 2P| 9701971015

OUTDOOR UNITFUJITSU AUY12LBAB Inverter Multi Air Conditioner Cassette
Type - OUTDOcOdsR UNIT

Ref.| Description| Part number|
---|---|---|---
31| Compressor Assy| 9373262015|
32| Terminal Cover (Comp)| 9373264019
33| Receiver Tank Assy| 9373426011
34| Strainer Assy| 9366602019
35| Accumulator| 9368391003
36| Solenoid| 9900165079
37| 4-Way Valve| 9900163013
38| Pressure Switch Assy| 9373729044
39| Capilarry Assy| 9373729211
40| Accum Support Assy| 9372252017
—| Thermal Switch| 9377956019
—| Gasket (Comp)| 9373266013
—| Compressor Pressure Switch| 9900186012
—| Compressor Thermal Switch| 9373263012
—| Thermistor Valve| 9900194017
—| Thermistor Discharge| 9704219039
—| Special Nut M8 (Comp)| 9355091008
—| Thermister Holder Pipe| 313714262805

OUTDOOR UNITFUJITSU AUY12LBAB Inverter Multi Air Conditioner Cassette
Type - OUTDOOR UNIT1

FUJITSU AUY12LBAB Inverter Multi Air Conditioner Cassette Type - OOUTDOOR
UNIT

Ref.| Description| Part number|
---|---|---|---
41| Compressor Cover A| 9373730019|
42| Compressor Cover B| 9373730026
43| Joint Pipe (3Way) Assy| 9373729129
44| Expansion Valve Assy| 9373729068
45| Expansion Valve Coil (White connector)| 9900197018
46| Expansion Valve Coil (Red connector)| 9900057022

ACCESSORIES

INDOOR UNIT

Name and Shape Application Part No.
Coupler heat insulation For indoor side pipe joint 9350716029

9352766015

Special nut A (large flange)| For installing indoor unit|

313005446653

Special nut B (small flange)| For installing indoor unit|

313005446759

Template| For ceiling hole cutting|

9360256003

Remote control| Use for air conditioner operation|

9371190037

Battery (penlight)| For remote control unit|

0600185534

Remote control holder| For mounting the remote control unit|

9305642014

Tapping screw ( 3 x 12)| For remote control unit holder installation| 301141533125

GRILLE ASSY

Name and Shape Application Part No.
Bolt For opening the refrigerant valve on the outdoor unit

0700139116

Washer| For mounting grille|

301801155020

Blower cover insulation| For discharged air|

9360047007

OUTDOOR UNIT

Name and Shape Part No.

Drain pipe

|

9303029015

Drain cap|

313166024302

Adapter D (1/2″       3/8″) 12.7mm      9.52mm|

9370244007

0507G2881

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

FUJITSU User Manuals

Related Manuals