DIEHL IZAR CENTER 25 Meters Memory Installation Guide

September 6, 2024
DIEHL

IZAR CENTER 25 Meters Memory

“`html

Specifications

Specification Value
Power Supply 110 – 230 V AC
Frequency 50 – 60 Hz
Interfaces M-Bus, USB/LAN, RS232/Rep Modem Rx/Tx
Operating Temperature Not specified
Humidity 10% – 90% relative humidity, non-condensing
Weight Approximately 472 g

Product Usage Instructions

1. General Information on the Guide

The guide is intended for trained specialized personnel. Basic
working steps are not included.

2. Package Content

Before installation or first-time use of the IZAR CENTER, check
the package content which includes: RS 232 (male), Interface cable
RS232 (female), and USB cable.

3. Description

The IZAR CENTER sends requests to connected meters via the
M-Bus. This action can be manual or automatic. For automatic meter
reading, a memory-equipped IZAR CENTER is needed with programmed
reading intervals. Meter data is stored internally and can be
transmitted to reading software.

4. Installation and Removal

Mounting IZAR CENTER: Follow the provided
instructions for mounting the IZAR CENTER securely.

Removing IZAR CENTER: To remove the IZAR
CENTER, follow the reverse steps of installation.

5. Electrical Connection

M-Bus Connections: Use the specified
connections for M-Bus devices.

LAN Connections: Use the specified connections
for LAN devices.

FAQ

Q: Can the IZAR CENTER be used with both USB and LAN

connections simultaneously?

A: Yes, the IZAR CENTER supports both USB and LAN connections
for communication with devices.

Q: How can I check the operating status of the IZAR

CENTER?

A: The operating status is indicated by a red light which shows
the bus load percentage from 0 to 100%.

“`

Deutsch English Français

IZAR CENTER
Einbauanleitung Installation guide Guide d’installation

29 30 31 32 33 34
M-Bus USB/LAN RS232/Rep Modem Rx/Tx
1 2 3 4 5 6
Diese Anleitung ist dem Endkunden auszuhändigen. This guide must be given to the end consumer. Ce guide doit être donné au client
final.

IZAR
CENTER 250 Memory

IZAR CENTER

I

29 30 31 32 33 34

68

M-Bus USB/LAN RS232/Rep Modem Rx/Tx

Deutsch English Français
IZAR
CENTER 250 Memory

67
1 2 3 4 5 6

66

65 16

II

29 30 31 32 33 34
M-Bus USB/LAN RS232/Rep Modem Rx/Tx
1 2 3 4 5 6

IZAR CENTER 250
Memory
PC (USB, LAN, RS232)

– 2 –

29 30 31 32 33 34
M-Bus USB/LAN RS232/Rep Modem Rx/Tx
1 2 3 4 5 6
Modem

IZAR CENTER 250
Memory

29 30 31 32 33 34
M-Bus USB/LAN RS232/Rep Modem Rx/Tx
1 2 3 4 5 6

PC (USB, LAN, RS232)

IZAR CENTER 250
Memory

Deutsch

IZAR CENTER

1. Allgemeines zur Anleitung
Die Anleitung wendet sich an ausgebildetes Fachpersonal. Grundlegende Arbeitsschritte sind deshalb nicht aufgeführt.

2. Verpackungsinhalt
Kontrollieren Sie bitte vor der Montage bzw. Inbetriebnahme des IZAR CENTER den Verpackungsinhalt.
IZAR CENTER RS 232 (male) Schnittstellenkabel RS232 (female) USB Kabel

3. Beschreibung
Der IZAR CENTER schickt eine Anfrage an die am M-Bus angeschlossenen Zähler. Diese Aktion kann manuell durch den Benutzer oder automatisch durch den IZAR CENTER ausgeführt werden.
Zur automatischen Zählerauslesung wird ein IZAR CENTER mit Memory benötigt, in den ein allgemeines oder zählerindividuelles Ausleseintervall programmiert wird. Der Zähler antwortet auf diese Anfrage, indem er seine aktuellen Werte an den IZAR CENTER schickt.
Die Zählerdaten werden in einem internen Speicher abgelegt und können von dort aus automatisiert an eine Ablesesoftware (IZAR@NET Software) übertragen werden.

– 3 –

IZAR CENTER

Deutsch

4. Technische Daten

Bezeichnung

Wert

Spannungsversorgung 110 … 230 V AC

Frequenz

50 … 60 Hz

Gehäuse Schutzklasse

Hutschienengehäuse mit Sicherungsautomatenprofil aus wärmebeständigem Kunststoff (ABS) IP 20

Schnittstellen

USB, Ethernet LAN, RS232 (für PC, Modem), M-Bus Ausgang und M-Bus Repeater Eingang

M-Bus Übertragungsraten 300, 600, 1200, 2400, 4800, 9600 Baud; AutobaudErkennung über RS232

Betriebstemperatur

-20 °C … +70 °C

Luftfeuchtigkeit Gewicht

10 % … 90 % relative Luftfeuchtigkeit, nicht kondensierend
ca. 472 g

– 4 –

Deutsch

IZAR CENTER

5. Hinweise

Das Gerät muss unter strikter Einhaltung der in der vorliegenden technischen Beschreibung angegebenen Vorschriften installiert und verwendet werden. Jegliche Manipulation oder Installation, die nicht ordnungsgemäß und entsprechend der genannten Vorschriften erfolgt, entbindet Diehl Metering von jeglicher Verantwortung. Diese liegt ausschließlich beim Verursacher.

Der IZAR CENTER darf nur von Fachkräften montiert und in Betrieb genommen werden.

6. Montage / Demontage
Vor jeder Montage oder Demontage muss die Stromzuführung (Buchse 16, Abb. I) unterbrochen werden.
IZAR CENTER montieren
Schnappen Sie den IZAR CENTER auf die Hutschiene auf. Der schwarze Sicherungsbügel (Buchse 65, Abb. I) muss dabei nach unten zeigen und hörbar einrasten.
IZAR CENTER demontieren
Benutzen Sie einen spitzen Gegenstand (z.B. Schraubendreher) und ziehen Sie den schwarzen Sicherungsbügel an der unteren Kante des IZAR CENTERs nach unten.
– 5 –

IZAR CENTER

Deutsch

Die Verriegelung wird damit gelöst und Sie können den IZAR CENTER von der Hutschiene abnehmen.

7. Elektrischer Anschluss (siehe Abb. I)

Bei Anschluss von LAN- und M-Bus Kabeln über lange Strecken oder zwischen Gebäuden ist die Zwischenschaltung eines Blitzschutzes erforderlich. Folgende Typen sind hierfür qualifiziert.
M-Bus Verbindungen:
Dehn BXT und Dehn-Modul BXT ML2 BD S48, Diehl Metering Art.-Nr. 3055664
LAN Verbindungen:
Dehn DPA M CAT6 RJ45 S48, Diehl Metering Art.-Nr. 3055635

Die Stromversorgung muss nicht unterbrochen werden, um M-Bus Geräte am IZAR CENTER anzuschließen.

Klemme / Beschreibung Buchse

1

M-Bus Repeater Eingang +

2

M-Bus Repeater Eingang –

5, 6

Schutzerde

16

110 … 230 V AC

Euro-Norm Schutzkontaktstecker

– 6 –

Deutsch

IZAR CENTER

Klemme / Beschreibung Buchse

20

Aufkleber mit Seriennummer und MAC-

Adresse

29, 31 33 M-Bus Ausgang +

30, 32, 34
65

M-Bus Ausgang Sicherungsbügel

66

Stecker für USB Anschluss

67

Stecker Mini DIN (8 pol.) für Anschluss

PC, Modem (RS232 Schnittstelle)

68

Stecker für LAN Anschluss

M-Bus-Zähler
Anschluss über die M-Bus Ausgangsklemmen.
Der M-Bus ist polaritätsunabhängig, es muss nur jeweils ein + und ein – Ausgang mit dem entsprechenden M-Bus Zähler verbunden werden. Alle M-Bus Ausgänge sind parallel geschaltet.
Repeater
M-Bus Ausgang eines weiteren IZAR CENTERs an die Klemmen 1 und 2 anschließen.
Verbinden Sie die Klemme 5 oder 6 mit einen Schutzerdepotential. Schutzerde muss am IZAR CENTER angeschlossen sein.

– 7 –

IZAR CENTER

Deutsch

Modem, PC
Anschluss an Buchse 67. Verwenden Sie dazu das mitgelieferte Schnittstellenkabel (maximale Kabellänge 10 m).
USB
Verwenden Sie das mitgelieferte USB Kabel (maximale Kabellänge 3 m). (Anschlussbeispiel siehe Abb. II)

8. Anzeigeelemente Fünf LEDs auf der Frontseite des IZAR CENTERs zeigen die jeweiligen Betriebszustände an.
M-Bus

Anzeige Betriebszustand

grün gelb
rot

0 … 100 % Buslast
100 … 130 % Buslast (Warnung) Die maximale M-Bus Leistung ist erreicht. Schließen sie keine weiteren M-Bus Zähler mehr an. In diesem Zustand ist der IZAR CENTER noch voll funktionsfähig
Überlast In diesem Fall sind entweder zu viele M-Bus Zähler angeschlossen, oder die Busleitungen haben einen Kurzschluss. Bei Busüberlast wird die M-Bus Spannung für ca. 2 Sekunden abgeschaltet. Danach wird der Busstrom überprüft und gegebenenfalls wiederum abgeschaltet.

– 8 –

Deutsch

IZAR CENTER

Kommunikation

Eingangskanal USB/LAN RS232/Rep Modem Rx/Tx

Anzeige / Betriebszustand
Grün (Eingang USB ist aktiv) Gelb (Eingang LAN ist aktiv)
Grün (Eingang RS232 ist aktiv) Gelb (Eingang Repeater ist aktiv)
Grün (Eingang RS232 ist aktiv) Gelb (Eingang Repeater ist aktiv)
Grün (Daten werden empfangen) Gelb (Daten werden gesendet)

9. Wartung Der IZAR CENTER benötigt keine besondere Wartung. Nicht mit Lösungsmitteln oder Scheuermittel reinigen, da diese das Kunststoffgehäuse beschädigen können. Wenn nötig, Tuch oder feuchten Schwamm zur Reinigung verwenden.
10. Lagerung Der IZAR CENTER kann an einem trockenen Ort bei Temperaturen zwischen -20 °C und +70 °C gelagert werden.
11. Umwelthinweis Das Gerät darf nicht mit dem Hausmüll entsorgt werden. Senden Sie es zum Recycling an den Hersteller zurück.

– 9 –

IZAR CENTER

Deutsch

12. Vereinfachte EU- und UK-Konformitätserklärung und UK PSTI Statement of Compliance
Hiermit erklärt Diehl Metering, dass der in dieser Bedienungsanleitung beschriebene Funktyp mit der Richtlinie 2014/53/EU und den UK Radio Equipment Regulations 2017 konform ist.
Zusätzlich erklärt Diehl Metering, dass der in dieser Bedienungsanleitung beschriebene Funktyp mit den UK PSTI Regulations konform ist.
Der vollständige Text der EU- und UK-Konformitätserklärung und der PSTI Statement of Compliance ist unter der folgenden Internetadresse verfügbar:
https://www.diehl.com/metering/de/support-center/ download-center/

– 10 –

English

IZAR CENTER

1. General information on the guide The guide is intended for trained specialised personnel. For this reason no basic working steps are included.

2. Package content
Please check the package content before you install or
use the IZAR CENTER for the first time. IZAR CENTER
RS 232 (male) Interface cable RS232 (female) USB cable

3. Description
The IZAR CENTER sends a request to the meters connected to the M-Bus. This action can be performed manually by the user or automatically by the IZAR CENTER.
For the automatic meter reading a IZAR CENTER with memory is required, where a general or meter individual reading interval is programmed. The meter responds to this request by sending the current values to the IZAR CENTER.
The meter data are stored in an internal memory and from there they can be transmitted automatically to a reading software (IZAR@NET Software).

– 11 –

IZAR CENTER

English

4. Technical data

Designation Power supply Frequency Housing
Protection class Interface
M-Bus transmission rate
Operating temperature Relative humidity Weight

Value
110 … 230 V AC 50 … 60 Hz Top hat rail housing with circuit breaker profile from heat-resistant plastic (ABS) IP 20 USB, Ethernet LAN, RS232 (for PC, modem), M-Bus output and M-Bus Repeater input 300, 600, 1200, 2400, 4800, 9600 baud; autobaud detection via RS232 -20 °C … +70 °C
10 % … 90 % relative humidity, non-condensing approx. 472g

– 12 –

English

IZAR CENTER

5. Instructions

The device must be installed and used in firm compliance with the specified rules in the present technical description. Any manipulation or installation, that is not properly carried out and does not correspond to the mentioned regulations, obviates any responsibility on the part of Diehl Metering. In this case, the responsibility lies solely with the originator.

The IZAR CENTER should be mounted and put into operation by qualified experts only.

6. Installation / removal Before every installation or removal the power supply (socket 16, fig. I) must be interrupted.
Install IZAR CENTER
Snap the IZAR CENTER onto the hat rail. The black safety catch (socket 65, fig. I) must point downwards and engage audibly. Remove IZAR CENTER
Use a pointed object (e.g. screwdriver) and pull the black safety catch on the lower edge of the IZAR CENTERs downwards.
– 13 –

IZAR CENTER

English

The locking is released and you can remove the IZAR CENTER from the hat rail.

7. Electrical connection (see fig. I)
If LAN- and M-Bus cables are connected over long distances or between buildings, the interconnection of a lightning protection is required. The following types are qualified for this purpose. M-Bus connections:
Dehn BXT and Dehn module BXT ML2 BD S48, Diehl Metering art. no. 3055664
LAN connections:
Dehn DPA M CAT6 RJ45 S48, Diehl Metering art. no. 3055635

The power supply must not be interrupted to connect M-Bus devices to IZAR CENTER.

Terminal / Description socket

1

M-Bus repeater input +

2

M-Bus repeater input –

5, 6

Protective ground

16

110 … 230 V AC

Euro safety plug

– 14 –

English

IZAR CENTER

Terminal / Description socket

20 29, 31 33

Sticker with serial number and MAC address
M-Bus output +

30, 32, 34 M-Bus output –

65

Safety catch

66

Plug for USB connection

67

Plug mini DIN (8 pol.) for connection PC,

modem (RS232 interface)

68

Plug for LAN connection

M-Bus meter
Connection via the M-Bus output terminal
The M-Bus is not polarity-conscious, a + and a – output must be connected to the corresponding M-Bus meter. All the M-Bus outputs are connected in parallel.
Repeater
Connect M-Bus output of a further IZAR CENTER to the terminals 1 and 2.
Connect terminal 5 or 6 with a protective ground potential. Protective ground must be connected to IZAR CENTER.

– 15 –

IZAR CENTER

English

Modem, PC
Connection to socket 67 Use the supplied interface cable (maximum cable length 10m).
USB
Use the supplied USB cable (maximum cable length 3 m). (Connection example see fig. II.)

8. Display elements Five LEDs on the front side of the IZAR CENTER show the corresponding operational conditions.
M-Bus

Display green yellow
red

Operational condition
0 … 100 % bus load
100 … 130 % bus load (warning) The maximum M-Bus performance is achieved. Do not connect further M-Bus meters. The IZAR CENTER is fully operational in this condition.
Overload In this case, too many M-Bus meter are connected or the bus wires have a short-circuit. If there is a bus overload, the M-Bus voltage is switched off for 2 seconds. Then the bus supply is checked and is also switched off if required.

– 16 –

English

IZAR CENTER

Communication

Input cable USB/LAN RS232/Rep Modem Rx/Tx

Display / operational condition
Green (input USB is active) Yellow (input LAN is active)
Green (input RS232 is active) Yellow (input Repeater is active)
Green (input RS232 is active) Yellow (input Repeater is active)
Green (data are received) Yellow (data are sent)

9. Maintenance The IZAR CENTER does not require any special maintenance. Do not use solvents or abrasive cleaning agents, as these may damage the plastic housing. If required, use a cloth or moist sponge for cleaning.
10. Storage The IZAR CENTER can be stored in a dry place at temperatures between -20 °C and +70 °C.
11. Environmental note The device must not be disposed together with the domestic waste. Return it to the manufacturer for recycling.

– 17 –

IZAR CENTER

English

12. Simplified EU and UK Declaration of Conformity and UK PSTI Statement of Compliance
Hereby, Diehl Metering declares that the radio equipment type described in this manual is in compliance with Directive 2014/53/EU and the UK Radio Equipment Regulations 2017.
In addition to this, Diehl Metering declares that the radio equipment type described in this manual is in compliance with the UK PSTI Regulations.
The full text of the EU Declaration of Conformity and UK Declaration of Conformity and of the PSTI Statement of Compliance is available at the following internet address:
https://www.diehl.com/metering/en/support-center/ download-center/

– 18 –

Français

IZAR CENTER

1. Généralités sur le mode d’emploi
Ce guide s’adresse au personnel spécialisé et qualifié. Les étapes de travail fondamentales n’y sont donc pas mentionnées.

2. Contenu de l’emballage
Contrôlez le contenu de l’emballage avant le montage ou la mise en service de IZAR CENTER.
IZAR CENTER RS 232 (mâle) Câble d’interface RS232 (femelle) Câble USB

3. Description
IZAR CENTER envoie une requête aux compteurs connectés au M-Bus. Cette action peut être exécutée manuellement par l’utilisateur ou automatiquement par l’IZAR CENTER.
Pour un relevé du compteur automatique il faut disposer d’un IZAR CENTER avec mémoire, dans laquelle l’intervalle de lecture générale ou spécifique est programmée. Le compteur répond à cette requête en envoyant les valeurs actuelles au IZAR CENTER.
Les données du compteur sont enregistrées pour rester en mémoire interne et peuvent être transmises à un logiciel (IZAR@NET Software).

– 19 –

IZAR CENTER

Français

4. Caractéristiques techniques

Désignation Alimentation électrique Fréquence Boîtier
Classe de protection Interfaces
Taux de transmission M-Bus Température de service L’humidité de l’air
Poids

Valeur
110 … 230 V AC
50 … 60 Hz
Boîtier du rail DIN avec disjoncteur automatique en plastique résistant à la chaleur (ABS).
IP 20
USB, Ethernet LAN, RS232 (pour PC, modem), M-Bus sortie et M-Bus Répéteur entrée
300, 600, 1200, 2400, 4800, 9600 baud; détection autobaud via RS232
-20 °C … +70 °C
10 % … 90 % l’humidité relative de l’air, sans condensation
env. 472 g

– 20 –

Français

IZAR CENTER

5. Indications

L’appareil doit être installé et utilisé en respectant strictement les prescriptions mentionnées dans les instructions techniques fournies. Toute manipulation ou installation se déroulant incorrectement et non conformément aux prescriptions mentionnées dégage Diehl Metering de toute responsabilité. Elle incombe exclusivement à son auteur.

Seul un personnel qualifié est autorisé à installer ou à mettre en marche l’IZAR CENTER.

6. Montage / Démontage Débrancher l’alimentation (prise 16, fig. I) avant le montage ou le démontage.
Montage de IZAR CENTER
Clipser l’IZAR CENTER sur le rail DIN. Le crochet de fixation noir (prise 65, fig. I) doit montrer vers le bas et l’encliquetage doit être audible. Démontage de IZAR CENTER
Utiliser un objet pointu (par ex. un tournevis) et abaisser le crochet de fixation noir au bord inférieur de l’IZAR CENTER.

– 21 –

IZAR CENTER

Français

Le verrouillage est ainsi débloqué et vous pouvez retirer le IZAR CENTER du rail DIN.

7. Raccordement électrique (voir fig. I)
Si des câbles LAN et M-Bus sont raccordés sur de longues distances ou entre des bâtiments, la mise en place de parafoudre est nécessaire. Nous avons qualifié les prochains types : M-Bus connections :
Dehn BXT et Dehn-Modul BXT ML2 BD S48, Diehl Metering Art.-No. 3055664
LAN connections:
Dehn DPA M CAT6 RJ45 S48, Diehl Metering Art.-No. 3055635

Il n’est pas nécessaire de débrancher l’alimentation pour connecter ou déconnecter un compteur M-Bus à l’IZAR CENTER.

Borne / prise Description

1

M-Bus Répéteur entrée +

2

M-Bus Répéteur entrée –

5, 6

Terre

16

110 … 230 V AC

Fiche de contact de sécurité (norme

Euro)

– 22 –

Français

IZAR CENTER

Borne / prise Description

20 29, 31 33

Autocollant avec numéro de série et l’adresse MAC
M-Bus sortie +

30, 32 34

M-Bus sortie –

65

Crochet de fixation

66

Connecteur USB

67

Connecteur Mini DIN (8 pol.) pour PC,

Modem (interface RS232)

68

Connecteur LAN

Compteur M-bus
Connexion via la borne de sortie M-Bus
Le M-Bus n’est pas polarisé, mais il faut utiliser une sortie + et une sortie – pour chaque compteur M-Bus. Toutes les sorties M-Bus sont en parallèle.
Répéteur
Connecter la sortie M-Bus d’un autre IZAR CENTER aux bornes 1 et 2.

Connecter la Terre à la borne 5 ou 6. La Terre doit être connectée à IZAR CENTER.

Modem, PC
Connecter sur la prise 67. Utiliser le câble fourni avec le modem (longueur maximale du câble : 10m). – 23 –

IZAR CENTER

Français

USB
Utiliser le câble USB fourni (longueur maximale du câble : 3 m). (Exemple de connexion voir fig. II)

8. Eléments d’affichage Les états de fonctionnement sont indiqués par cinq LED sur la face avant de IZAR CENTER.
M-Bus

Affichage vert jaune
rouge

Etat de fonctionnement
0 … 100 …charge du bus
100 … 130 %…charge du bus (avertissement) La performance maximale M-Bus est atteinte. Ne pas connecter plus de compteurs M-Bus. Dans ce cas l’IZAR CENTER est au maximum de sa capacité.
Surcharge Dans ce cas, trop de compteurs M-Bus sont connectés ou la ligne M-Bus est en court-circuit. S’il y a une surcharge, le courant M-Bus est coupé pour env. 2 secondes. Le courant Bus est vérifié et, si besoin, coupé de nouveau.

– 24 –

Français

IZAR CENTER

Communication

Canal d’entrée USB/LAN RS232/Rép Modem Rx/Tx

Affichage / état de fonctionnement
Vert (entrée USB activée) Jaune (entrée LAN activée)
Vert (entrée RS232 activée) Jaune (entrée Répéteur activée)
Vert (entrée RS232 activée) Jaune (entrée Répéteur activée)
Vert (données reçues) Jaune (données transmises)

9. Entretien
L’IZAR CENTER n’a besoin d’aucun entretien particulier. N’utilisez pas des produits chimiques abrasifs et à base de solvant parce que le boîtier en plastique pourrait être endommagé. Si nécessaire, nettoyez avec un chiffon ou une éponge humide.

10. Entreposage
L’IZAR CENTER peut être stocké à un lieu sec entre -20 °C et +70 °C.

11. Faits concernant lenvironnement Lappareil ne doit pas être jeté dans les ordures ménagères. Retournez-le au fabricant pour le recyclage.

– 25 –

IZAR CENTER

Français

12. Déclarations de conformité simplifiées UE, UK et UK PSTI Statement of Compliance
Par la présente, Diehl Metering déclare que le type d’équipement radio décrit dans ce guide d’installation est conforme à la directive 2014/53/UE et au règlement UK sur les équipements radio 2017.
Diehl Metering déclare également que le type d’équipement radio décrit dans ce guide d’installation est conforme aux réglementations UK PSTI.
Les textes complets des déclarations de conformité UE, UK et de la UK PSTI Statement of Compliance sont disponibles à l’adresse internet suivante :
https://www.diehl.com/metering/en/support-center/ download-center/

– 26 –

Technische Änderungen vorbehalten · Technical changes reserved

Mat.-Nr. 3061583 · 29/8/2024

Diehl Metering GmbH Industriestrasse 13 91522 Ansbach Phone: +49 981 1806-0 Fax: +49 981 1806-615 metering-germany-info@diehl.com
www.diehl.com/metering

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals