“`html
Specifications
Specification | Value |
---|---|
Power Supply | 110 – 230 V AC |
Frequency | 50 – 60 Hz |
Interfaces | M-Bus, USB/LAN, RS232/Rep Modem Rx/Tx |
Operating Temperature | Not specified |
Humidity | 10% – 90% relative humidity, non-condensing |
Weight | Approximately 472 g |
Product Usage Instructions
1. General Information on the Guide
The guide is intended for trained specialized personnel. Basic
working steps are not included.
2. Package Content
Before installation or first-time use of the IZAR CENTER, check
the package content which includes: RS 232 (male), Interface cable
RS232 (female), and USB cable.
3. Description
The IZAR CENTER sends requests to connected meters via the
M-Bus. This action can be manual or automatic. For automatic meter
reading, a memory-equipped IZAR CENTER is needed with programmed
reading intervals. Meter data is stored internally and can be
transmitted to reading software.
4. Installation and Removal
Mounting IZAR CENTER: Follow the provided
instructions for mounting the IZAR CENTER securely.
Removing IZAR CENTER: To remove the IZAR
CENTER, follow the reverse steps of installation.
5. Electrical Connection
M-Bus Connections: Use the specified
connections for M-Bus devices.
LAN Connections: Use the specified connections
for LAN devices.
FAQ
Q: Can the IZAR CENTER be used with both USB and LAN
connections simultaneously?
A: Yes, the IZAR CENTER supports both USB and LAN connections
for communication with devices.
Q: How can I check the operating status of the IZAR
CENTER?
A: The operating status is indicated by a red light which shows
the bus load percentage from 0 to 100%.
“`
Deutsch English Français
IZAR CENTER
Einbauanleitung Installation guide Guide d’installation
29 30 31 32 33 34
M-Bus USB/LAN RS232/Rep Modem Rx/Tx
1 2 3 4 5 6
Diese Anleitung ist dem Endkunden auszuhändigen. This guide must be given to
the end consumer. Ce guide doit être donné au client
final.
IZAR
CENTER 250 Memory
IZAR CENTER
I
29 30 31 32 33 34
68
M-Bus USB/LAN RS232/Rep Modem Rx/Tx
Deutsch English Français
IZAR
CENTER 250 Memory
67
1 2 3 4 5 6
66
65 16
II
29 30 31 32 33 34
M-Bus USB/LAN RS232/Rep Modem Rx/Tx
1 2 3 4 5 6
IZAR CENTER 250
Memory
PC (USB, LAN, RS232)
– 2 –
29 30 31 32 33 34
M-Bus USB/LAN RS232/Rep Modem Rx/Tx
1 2 3 4 5 6
Modem
IZAR CENTER 250
Memory
29 30 31 32 33 34
M-Bus USB/LAN RS232/Rep Modem Rx/Tx
1 2 3 4 5 6
PC (USB, LAN, RS232)
IZAR CENTER 250
Memory
Deutsch
IZAR CENTER
1. Allgemeines zur Anleitung
Die Anleitung wendet sich an ausgebildetes Fachpersonal. Grundlegende
Arbeitsschritte sind deshalb nicht aufgeführt.
2. Verpackungsinhalt
Kontrollieren Sie bitte vor der Montage bzw. Inbetriebnahme des IZAR CENTER
den Verpackungsinhalt.
IZAR CENTER RS 232 (male) Schnittstellenkabel RS232 (female) USB Kabel
3. Beschreibung
Der IZAR CENTER schickt eine Anfrage an die am M-Bus angeschlossenen Zähler.
Diese Aktion kann manuell durch den Benutzer oder automatisch durch den IZAR
CENTER ausgeführt werden.
Zur automatischen Zählerauslesung wird ein IZAR CENTER mit Memory benötigt, in
den ein allgemeines oder zählerindividuelles Ausleseintervall programmiert
wird. Der Zähler antwortet auf diese Anfrage, indem er seine aktuellen Werte
an den IZAR CENTER schickt.
Die Zählerdaten werden in einem internen Speicher abgelegt und können von dort
aus automatisiert an eine Ablesesoftware (IZAR@NET Software) übertragen
werden.
– 3 –
IZAR CENTER
Deutsch
4. Technische Daten
Bezeichnung
Wert
Spannungsversorgung 110 … 230 V AC
Frequenz
50 … 60 Hz
Gehäuse Schutzklasse
Hutschienengehäuse mit Sicherungsautomatenprofil aus wärmebeständigem Kunststoff (ABS) IP 20
Schnittstellen
USB, Ethernet LAN, RS232 (für PC, Modem), M-Bus Ausgang und M-Bus Repeater Eingang
M-Bus Übertragungsraten 300, 600, 1200, 2400, 4800, 9600 Baud; AutobaudErkennung über RS232
Betriebstemperatur
-20 °C … +70 °C
Luftfeuchtigkeit Gewicht
10 % … 90 % relative Luftfeuchtigkeit, nicht kondensierend
ca. 472 g
– 4 –
Deutsch
IZAR CENTER
5. Hinweise
Das Gerät muss unter strikter Einhaltung der in der vorliegenden technischen Beschreibung angegebenen Vorschriften installiert und verwendet werden. Jegliche Manipulation oder Installation, die nicht ordnungsgemäß und entsprechend der genannten Vorschriften erfolgt, entbindet Diehl Metering von jeglicher Verantwortung. Diese liegt ausschließlich beim Verursacher.
Der IZAR CENTER darf nur von Fachkräften montiert und in Betrieb genommen werden.
6. Montage / Demontage
Vor jeder Montage oder Demontage muss die Stromzuführung (Buchse 16, Abb. I)
unterbrochen werden.
IZAR CENTER montieren
Schnappen Sie den IZAR CENTER auf die Hutschiene auf. Der schwarze
Sicherungsbügel (Buchse 65, Abb. I) muss dabei nach unten zeigen und hörbar
einrasten.
IZAR CENTER demontieren
Benutzen Sie einen spitzen Gegenstand (z.B. Schraubendreher) und ziehen Sie
den schwarzen Sicherungsbügel an der unteren Kante des IZAR CENTERs nach
unten.
– 5 –
IZAR CENTER
Deutsch
Die Verriegelung wird damit gelöst und Sie können den IZAR CENTER von der Hutschiene abnehmen.
7. Elektrischer Anschluss (siehe Abb. I)
Bei Anschluss von LAN- und M-Bus Kabeln über lange Strecken oder zwischen
Gebäuden ist die Zwischenschaltung eines Blitzschutzes erforderlich. Folgende
Typen sind hierfür qualifiziert.
M-Bus Verbindungen:
Dehn BXT und Dehn-Modul BXT ML2 BD S48, Diehl Metering Art.-Nr. 3055664
LAN Verbindungen:
Dehn DPA M CAT6 RJ45 S48, Diehl Metering Art.-Nr. 3055635
Die Stromversorgung muss nicht unterbrochen werden, um M-Bus Geräte am IZAR CENTER anzuschließen.
Klemme / Beschreibung Buchse
1
M-Bus Repeater Eingang +
2
M-Bus Repeater Eingang –
5, 6
Schutzerde
16
110 … 230 V AC
Euro-Norm Schutzkontaktstecker
– 6 –
Deutsch
IZAR CENTER
Klemme / Beschreibung Buchse
20
Aufkleber mit Seriennummer und MAC-
Adresse
29, 31 33 M-Bus Ausgang +
30, 32, 34
65
M-Bus Ausgang Sicherungsbügel
66
Stecker für USB Anschluss
67
Stecker Mini DIN (8 pol.) für Anschluss
PC, Modem (RS232 Schnittstelle)
68
Stecker für LAN Anschluss
M-Bus-Zähler
Anschluss über die M-Bus Ausgangsklemmen.
Der M-Bus ist polaritätsunabhängig, es muss nur jeweils ein + und ein –
Ausgang mit dem entsprechenden M-Bus Zähler verbunden werden. Alle M-Bus
Ausgänge sind parallel geschaltet.
Repeater
M-Bus Ausgang eines weiteren IZAR CENTERs an die Klemmen 1 und 2 anschließen.
Verbinden Sie die Klemme 5 oder 6 mit einen Schutzerdepotential. Schutzerde
muss am IZAR CENTER angeschlossen sein.
– 7 –
IZAR CENTER
Deutsch
Modem, PC
Anschluss an Buchse 67. Verwenden Sie dazu das mitgelieferte
Schnittstellenkabel (maximale Kabellänge 10 m).
USB
Verwenden Sie das mitgelieferte USB Kabel (maximale Kabellänge 3 m).
(Anschlussbeispiel siehe Abb. II)
8. Anzeigeelemente Fünf LEDs auf der Frontseite des IZAR CENTERs zeigen die
jeweiligen Betriebszustände an.
M-Bus
Anzeige Betriebszustand
grün gelb
rot
0 … 100 % Buslast
100 … 130 % Buslast (Warnung) Die maximale M-Bus Leistung ist erreicht.
Schließen sie keine weiteren M-Bus Zähler mehr an. In diesem Zustand ist der
IZAR CENTER noch voll funktionsfähig
Überlast In diesem Fall sind entweder zu viele M-Bus Zähler angeschlossen,
oder die Busleitungen haben einen Kurzschluss. Bei Busüberlast wird die M-Bus
Spannung für ca. 2 Sekunden abgeschaltet. Danach wird der Busstrom überprüft
und gegebenenfalls wiederum abgeschaltet.
– 8 –
Deutsch
IZAR CENTER
Kommunikation
Eingangskanal USB/LAN RS232/Rep Modem Rx/Tx
Anzeige / Betriebszustand
Grün (Eingang USB ist aktiv) Gelb (Eingang LAN ist aktiv)
Grün (Eingang RS232 ist aktiv) Gelb (Eingang Repeater ist aktiv)
Grün (Eingang RS232 ist aktiv) Gelb (Eingang Repeater ist aktiv)
Grün (Daten werden empfangen) Gelb (Daten werden gesendet)
9. Wartung Der IZAR CENTER benötigt keine besondere Wartung. Nicht mit
Lösungsmitteln oder Scheuermittel reinigen, da diese das Kunststoffgehäuse
beschädigen können. Wenn nötig, Tuch oder feuchten Schwamm zur Reinigung
verwenden.
10. Lagerung Der IZAR CENTER kann an einem trockenen Ort bei Temperaturen
zwischen -20 °C und +70 °C gelagert werden.
11. Umwelthinweis Das Gerät darf nicht mit dem Hausmüll entsorgt werden.
Senden Sie es zum Recycling an den Hersteller zurück.
– 9 –
IZAR CENTER
Deutsch
12. Vereinfachte EU- und UK-Konformitätserklärung und UK PSTI Statement of
Compliance
Hiermit erklärt Diehl Metering, dass der in dieser Bedienungsanleitung
beschriebene Funktyp mit der Richtlinie 2014/53/EU und den UK Radio Equipment
Regulations 2017 konform ist.
Zusätzlich erklärt Diehl Metering, dass der in dieser Bedienungsanleitung
beschriebene Funktyp mit den UK PSTI Regulations konform ist.
Der vollständige Text der EU- und UK-Konformitätserklärung und der PSTI
Statement of Compliance ist unter der folgenden Internetadresse verfügbar:
https://www.diehl.com/metering/de/support-center/ download-center/
– 10 –
English
IZAR CENTER
1. General information on the guide The guide is intended for trained specialised personnel. For this reason no basic working steps are included.
2. Package content
Please check the package content before you install or
use the IZAR CENTER for the first time. IZAR CENTER
RS 232 (male) Interface cable RS232 (female) USB cable
3. Description
The IZAR CENTER sends a request to the meters connected to the M-Bus. This
action can be performed manually by the user or automatically by the IZAR
CENTER.
For the automatic meter reading a IZAR CENTER with memory is required, where a
general or meter individual reading interval is programmed. The meter responds
to this request by sending the current values to the IZAR CENTER.
The meter data are stored in an internal memory and from there they can be
transmitted automatically to a reading software (IZAR@NET Software).
– 11 –
IZAR CENTER
English
4. Technical data
Designation Power supply Frequency Housing
Protection class Interface
M-Bus transmission rate
Operating temperature Relative humidity Weight
Value
110 … 230 V AC 50 … 60 Hz Top hat rail housing with circuit breaker profile
from heat-resistant plastic (ABS) IP 20 USB, Ethernet LAN, RS232 (for PC,
modem), M-Bus output and M-Bus Repeater input 300, 600, 1200, 2400, 4800, 9600
baud; autobaud detection via RS232 -20 °C … +70 °C
10 % … 90 % relative humidity, non-condensing approx. 472g
– 12 –
English
IZAR CENTER
5. Instructions
The device must be installed and used in firm compliance with the specified rules in the present technical description. Any manipulation or installation, that is not properly carried out and does not correspond to the mentioned regulations, obviates any responsibility on the part of Diehl Metering. In this case, the responsibility lies solely with the originator.
The IZAR CENTER should be mounted and put into operation by qualified experts only.
6. Installation / removal Before every installation or removal the power
supply (socket 16, fig. I) must be interrupted.
Install IZAR CENTER
Snap the IZAR CENTER onto the hat rail. The black safety catch (socket 65,
fig. I) must point downwards and engage audibly. Remove IZAR CENTER
Use a pointed object (e.g. screwdriver) and pull the black safety catch on the
lower edge of the IZAR CENTERs downwards.
– 13 –
IZAR CENTER
English
The locking is released and you can remove the IZAR CENTER from the hat rail.
7. Electrical connection (see fig. I)
If LAN- and M-Bus cables are connected over long distances or between
buildings, the interconnection of a lightning protection is required. The
following types are qualified for this purpose. M-Bus connections:
Dehn BXT and Dehn module BXT ML2 BD S48, Diehl Metering art. no. 3055664
LAN connections:
Dehn DPA M CAT6 RJ45 S48, Diehl Metering art. no. 3055635
The power supply must not be interrupted to connect M-Bus devices to IZAR CENTER.
Terminal / Description socket
1
M-Bus repeater input +
2
M-Bus repeater input –
5, 6
Protective ground
16
110 … 230 V AC
Euro safety plug
– 14 –
English
IZAR CENTER
Terminal / Description socket
20 29, 31 33
Sticker with serial number and MAC address
M-Bus output +
30, 32, 34 M-Bus output –
65
Safety catch
66
Plug for USB connection
67
Plug mini DIN (8 pol.) for connection PC,
modem (RS232 interface)
68
Plug for LAN connection
M-Bus meter
Connection via the M-Bus output terminal
The M-Bus is not polarity-conscious, a + and a – output must be connected to
the corresponding M-Bus meter. All the M-Bus outputs are connected in
parallel.
Repeater
Connect M-Bus output of a further IZAR CENTER to the terminals 1 and 2.
Connect terminal 5 or 6 with a protective ground potential. Protective ground
must be connected to IZAR CENTER.
– 15 –
IZAR CENTER
English
Modem, PC
Connection to socket 67 Use the supplied interface cable (maximum cable length
10m).
USB
Use the supplied USB cable (maximum cable length 3 m). (Connection example see
fig. II.)
8. Display elements Five LEDs on the front side of the IZAR CENTER show the
corresponding operational conditions.
M-Bus
Display green yellow
red
Operational condition
0 … 100 % bus load
100 … 130 % bus load (warning) The maximum M-Bus performance is achieved. Do
not connect further M-Bus meters. The IZAR CENTER is fully operational in this
condition.
Overload In this case, too many M-Bus meter are connected or the bus wires
have a short-circuit. If there is a bus overload, the M-Bus voltage is
switched off for 2 seconds. Then the bus supply is checked and is also
switched off if required.
– 16 –
English
IZAR CENTER
Communication
Input cable USB/LAN RS232/Rep Modem Rx/Tx
Display / operational condition
Green (input USB is active) Yellow (input LAN is active)
Green (input RS232 is active) Yellow (input Repeater is active)
Green (input RS232 is active) Yellow (input Repeater is active)
Green (data are received) Yellow (data are sent)
9. Maintenance The IZAR CENTER does not require any special maintenance. Do
not use solvents or abrasive cleaning agents, as these may damage the plastic
housing. If required, use a cloth or moist sponge for cleaning.
10. Storage The IZAR CENTER can be stored in a dry place at temperatures
between -20 °C and +70 °C.
11. Environmental note The device must not be disposed together with the
domestic waste. Return it to the manufacturer for recycling.
– 17 –
IZAR CENTER
English
12. Simplified EU and UK Declaration of Conformity and UK PSTI Statement of
Compliance
Hereby, Diehl Metering declares that the radio equipment type described in
this manual is in compliance with Directive 2014/53/EU and the UK Radio
Equipment Regulations 2017.
In addition to this, Diehl Metering declares that the radio equipment type
described in this manual is in compliance with the UK PSTI Regulations.
The full text of the EU Declaration of Conformity and UK Declaration of
Conformity and of the PSTI Statement of Compliance is available at the
following internet address:
https://www.diehl.com/metering/en/support-center/ download-center/
– 18 –
Français
IZAR CENTER
1. Généralités sur le mode d’emploi
Ce guide s’adresse au personnel spécialisé et qualifié. Les étapes de travail
fondamentales n’y sont donc pas mentionnées.
2. Contenu de l’emballage
Contrôlez le contenu de l’emballage avant le montage ou la mise en service de
IZAR CENTER.
IZAR CENTER RS 232 (mâle) Câble d’interface RS232 (femelle) Câble USB
3. Description
IZAR CENTER envoie une requête aux compteurs connectés au M-Bus. Cette action
peut être exécutée manuellement par l’utilisateur ou automatiquement par
l’IZAR CENTER.
Pour un relevé du compteur automatique il faut disposer d’un IZAR CENTER avec
mémoire, dans laquelle l’intervalle de lecture générale ou spécifique est
programmée. Le compteur répond à cette requête en envoyant les valeurs
actuelles au IZAR CENTER.
Les données du compteur sont enregistrées pour rester en mémoire interne et
peuvent être transmises à un logiciel (IZAR@NET Software).
– 19 –
IZAR CENTER
Français
4. Caractéristiques techniques
Désignation Alimentation électrique Fréquence Boîtier
Classe de protection Interfaces
Taux de transmission M-Bus Température de service L’humidité de l’air
Poids
Valeur
110 … 230 V AC
50 … 60 Hz
Boîtier du rail DIN avec disjoncteur automatique en plastique résistant à la
chaleur (ABS).
IP 20
USB, Ethernet LAN, RS232 (pour PC, modem), M-Bus sortie et M-Bus Répéteur
entrée
300, 600, 1200, 2400, 4800, 9600 baud; détection autobaud via RS232
-20 °C … +70 °C
10 % … 90 % l’humidité relative de l’air, sans condensation
env. 472 g
– 20 –
Français
IZAR CENTER
5. Indications
L’appareil doit être installé et utilisé en respectant strictement les prescriptions mentionnées dans les instructions techniques fournies. Toute manipulation ou installation se déroulant incorrectement et non conformément aux prescriptions mentionnées dégage Diehl Metering de toute responsabilité. Elle incombe exclusivement à son auteur.
Seul un personnel qualifié est autorisé à installer ou à mettre en marche l’IZAR CENTER.
6. Montage / Démontage Débrancher l’alimentation (prise 16, fig. I) avant le
montage ou le démontage.
Montage de IZAR CENTER
Clipser l’IZAR CENTER sur le rail DIN. Le crochet de fixation noir (prise 65,
fig. I) doit montrer vers le bas et l’encliquetage doit être audible.
Démontage de IZAR CENTER
Utiliser un objet pointu (par ex. un tournevis) et abaisser le crochet de
fixation noir au bord inférieur de l’IZAR CENTER.
– 21 –
IZAR CENTER
Français
Le verrouillage est ainsi débloqué et vous pouvez retirer le IZAR CENTER du rail DIN.
7. Raccordement électrique (voir fig. I)
Si des câbles LAN et M-Bus sont raccordés sur de longues distances ou entre
des bâtiments, la mise en place de parafoudre est nécessaire. Nous avons
qualifié les prochains types : M-Bus connections :
Dehn BXT et Dehn-Modul BXT ML2 BD S48, Diehl Metering Art.-No. 3055664
LAN connections:
Dehn DPA M CAT6 RJ45 S48, Diehl Metering Art.-No. 3055635
Il n’est pas nécessaire de débrancher l’alimentation pour connecter ou déconnecter un compteur M-Bus à l’IZAR CENTER.
Borne / prise Description
1
M-Bus Répéteur entrée +
2
M-Bus Répéteur entrée –
5, 6
Terre
16
110 … 230 V AC
Fiche de contact de sécurité (norme
Euro)
– 22 –
Français
IZAR CENTER
Borne / prise Description
20 29, 31 33
Autocollant avec numéro de série et l’adresse MAC
M-Bus sortie +
30, 32 34
M-Bus sortie –
65
Crochet de fixation
66
Connecteur USB
67
Connecteur Mini DIN (8 pol.) pour PC,
Modem (interface RS232)
68
Connecteur LAN
Compteur M-bus
Connexion via la borne de sortie M-Bus
Le M-Bus n’est pas polarisé, mais il faut utiliser une sortie + et une sortie
– pour chaque compteur M-Bus. Toutes les sorties M-Bus sont en parallèle.
Répéteur
Connecter la sortie M-Bus d’un autre IZAR CENTER aux bornes 1 et 2.
Connecter la Terre à la borne 5 ou 6. La Terre doit être connectée à IZAR CENTER.
Modem, PC
Connecter sur la prise 67. Utiliser le câble fourni avec le modem (longueur
maximale du câble : 10m). – 23 –
IZAR CENTER
Français
USB
Utiliser le câble USB fourni (longueur maximale du câble : 3 m). (Exemple de
connexion voir fig. II)
8. Eléments d’affichage Les états de fonctionnement sont indiqués par cinq
LED sur la face avant de IZAR CENTER.
M-Bus
Affichage vert jaune
rouge
Etat de fonctionnement
0 … 100 …charge du bus
100 … 130 %…charge du bus (avertissement) La performance maximale M-Bus est
atteinte. Ne pas connecter plus de compteurs M-Bus. Dans ce cas l’IZAR CENTER
est au maximum de sa capacité.
Surcharge Dans ce cas, trop de compteurs M-Bus sont connectés ou la ligne
M-Bus est en court-circuit. S’il y a une surcharge, le courant M-Bus est coupé
pour env. 2 secondes. Le courant Bus est vérifié et, si besoin, coupé de
nouveau.
– 24 –
Français
IZAR CENTER
Communication
Canal d’entrée USB/LAN RS232/Rép Modem Rx/Tx
Affichage / état de fonctionnement
Vert (entrée USB activée) Jaune (entrée LAN activée)
Vert (entrée RS232 activée) Jaune (entrée Répéteur activée)
Vert (entrée RS232 activée) Jaune (entrée Répéteur activée)
Vert (données reçues) Jaune (données transmises)
9. Entretien
L’IZAR CENTER n’a besoin d’aucun entretien particulier. N’utilisez pas des
produits chimiques abrasifs et à base de solvant parce que le boîtier en
plastique pourrait être endommagé. Si nécessaire, nettoyez avec un chiffon ou
une éponge humide.
10. Entreposage
L’IZAR CENTER peut être stocké à un lieu sec entre -20 °C et +70 °C.
11. Faits concernant lenvironnement L
appareil ne doit pas être jeté dans les ordures ménagères. Retournez-le au
fabricant pour le recyclage.
– 25 –
IZAR CENTER
Français
12. Déclarations de conformité simplifiées UE, UK et UK PSTI Statement of
Compliance
Par la présente, Diehl Metering déclare que le type d’équipement radio décrit
dans ce guide d’installation est conforme à la directive 2014/53/UE et au
règlement UK sur les équipements radio 2017.
Diehl Metering déclare également que le type d’équipement radio décrit dans ce
guide d’installation est conforme aux réglementations UK PSTI.
Les textes complets des déclarations de conformité UE, UK et de la UK PSTI
Statement of Compliance sont disponibles à l’adresse internet suivante :
https://www.diehl.com/metering/en/support-center/ download-center/
– 26 –
Technische Änderungen vorbehalten · Technical changes reserved
Mat.-Nr. 3061583 · 29/8/2024
Diehl Metering GmbH Industriestrasse 13 91522 Ansbach Phone: +49 981 1806-0
Fax: +49 981 1806-615 metering-germany-info@diehl.com
www.diehl.com/metering
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>