Specifications:
- Product Name: SUPER SCOPE PRO
- Manufacturer: Company Name
- Address: No. 43, Yunfeng Road, Xiuquan Street, Huadu District,
Guangzhou, China
Product Information:
Congratulations on choosing our company product! We thank you
for your custom. Please keep in mind that this product, like other
products of the company, adheres to the concept of people-oriented
design and manufacture, and takes product quality as the
foundation. We put the interests of customers first and do our best
to meet customer requirements. Please read this instruction manual
carefully and keep it for future reference. It is essential to
strictly abide by the instructions provided to ensure correct and
safe installation, use, and maintenance of the product.
Safety Instructions:
Please read the instruction manual carefully as it contains
important information about the installation, usage, and
maintenance of the product.
-
Keep the User Manual for future reference.
-
Ensure the unit is unpacked and checked for transportation
damage before use. -
Use the product indoors in a dry location.
-
Only install and operate the unit with a qualified
operator. -
Do not allow children to operate the fixture.
-
Use a safety chain when fixing the unit.
-
Handle the unit by carrying its base instead of head only.
-
Ensure proper ventilation during installation at least 20cm
from adjacent surfaces. -
Check that no ventilation slots are blocked to prevent
overheating. -
Always cut off the power supply before replacing the light
source.
Product Usage Instructions:
1. Color/Gobo/Prism:
Insert information about how to use the color, gobo, and prism
features of the product.
2. Control Panel:
Explain how to navigate and use the control panel
effectively.
3. Connection and Control:
Provide detailed steps on how to connect the product and control
its functions.
FAQ:
Q: Can this product be used outdoors?
A: No, this product is designed for indoor use only. Using it
outdoors may result in damage or safety hazards.
Q: Who should replace the light source in the luminaire?
A: The light source in this luminaire should be replaced by the
manufacturer or its service agent or a similarly qualified person.
Always cut off the power supply before replacing the light
source.
n E-mail:
Address: No. 43, Yunfeng Road, Xiuquan Street, Huadu District, Guangzhou,
China
SUPER SCOPE PRO
CONTENTS
1. Safety Instructions……………………………………………………………………………………….2 2. Technical
Specifications ……………………………………………………………………………….5
2.1. Attachment And Size …………………………………………………………………………….7 3.Color/Gobo/Prism
……………………………………………………………………………….9 4. Control Panel
…………………………………………………………………………………………….10 5. Connection and control
………………………………………………………………………………11
5.1. Power supply connection …………………………………………………………………….11 5.2. DMX 512
Connection…………………………………………………………………………..12 6. How To Set The Unit
…………………………………………………………………………………..13 6.1. Main
Function…………………………………………………………………………………….13 6.2. Channel
Setting………………………………………………………………………………….15 6.3. Address
Setting………………………………………………………………………………….15 6.4. DMX 512 Configuration
……………………………………………………………………….16 7. Electrical Connection Diagram
…………………………………………………………………….19 8.
Troubleshooting…………………………………………………………………………………………20 9. Fixture
Cleaning…………………………………………………………………………………………22 10. Duty exonerative and
copyright protectio…………………………………………………….22
Congratulations on choosing our company product! We thank you for your custom.
Please keep in mind that this product, like other products of the company,
adheres to the concept of
people-oriented design and manufacture, and takes product quality as the
foundation. We put the interests of customers first, and do our best to meet
customer requirements. Please read this instruction manual carefully and keep
it for future reference. In the case of fully
understanding the product information, strictly abide by theUse the
instruction manual to ensure that the product is installed, used and serviced
correctly and safely. Our company is not responsible for any damage to lamps
or other performance due to personal failure to follow the instructions during
installation, use and maintenance.responsibility. Our company reserves the
right to modify the manual at any time and without prior notice.
-1-
1.Safety Instructions
Please read the instruction carefully which includes important information
about the installation, usage and maintenance.
WARNING Please keep this User Manual for future consultation. If you sell the
unit to another user, be sure that they also receive this manual. The
following symbols are used to identify important safety information on the
product and in this manual:
Important: Damages caused by the disregard of this user manual are not subject
to warranty. The dealer will not accept liability for any resulting defects or
problems. Unpack and check carefully to ensure that there is no transportation
damage before
using the unit. This product is for indoor use only. Use only in a dry
location. Do install and operate by qualified operator. The light source in
this luminaire should be replaced by the manufacturer or its service agent
or a similarly qualified person, always cut off the power supply before
replacing he light source. Do not allow children to operate the fixture. Use
safety chain when fixing the unit. Handle the unit by carrying its base
instead of head only.
-2-
The unit must be installed in a location with adequate ventilation, at least
20cm from adjacent surfaces.
Be sure that no ventilation slots is blocked, otherwise the unit will be
overheated. Before operation, ensure that you are connecting this product to
the proper voltage in
accordance with the specifications in this manual or on the product’s
specification label. It’s important to ground the yellow/green conductor to
earth in order to avoid electric shock. Minimum ambient temperature Ta: 0.
Maximum ambient temperature Ta: 40.
Do not operate this product at a lower or higher temperature. Do not connect
the device to any dimmer pack. When the lamp is running, do not place
combustible objects next to it. The shortest
distance between the device and inflammable and explosive objects or materials
is 0.5m. Make sure the power cord is not crimped or damaged; replace it
immediately if damaged. Unit’s surface temperature may reach up to 80. do not
touch the housing
bare-handedduring its operation. Avoid any flammable liquids, water or metal
from entering the unit. Once it happens, cut off the mains power immediately.
Do not operate in a dirty or dusty environment. do clean the fixture
regularly. Do not touch any wire during operation as there might be a hazard
of electric shock. Avoid entanglement of the power cord with other wires. The
minimum distance to objects/surface must be more than 3 meters. In the event
of serious operating problem, stop using the unit immediately. Never turn on
and off the unit time after time. The housing, the lenses, or the ultraviolet
filter must be replaced if they are visibly
damaged. Do not open the housing as there are no user serviceable parts
inside. Do not attempt to operate this unit if it becomes damaged. do not
attempt any
repairs yourself. Repairs carried out by unskilled people can lead to damage
or malfunction. Please contact the nearest authorized technical assistance
center if needed. Disconnect this product from its power source before
servicing. Do use the original packaging if the device is to be transported.
Avoid direct eye exposure to the light source while the product is on.
-3-
Do not operate this product if you see damage on the housing, shields, or
cables. Have the damaged parts replaced by an authorized technician at once.
Installation: The fixture should be fixed on the clamp. Always ensure that the
unit is firmly fixed to
avoid vibration and slipping off during operation. Ensure that the trussing or
area of installation must be able to hold 10 times the weight without any
deformation. Always install a safety cable that can hold at least 12 times the
weight of the fixture when installing.do install and operate by qualified
operator. It must be installed in a place where there is out of the reach of
people.
-4-
2.Technical Specifications
OPTICAL – Light source: 450W white LED module – Zoom range: 4°- 53° – Optical
lens: coated with high anti-reflection coating, diameter 133mm – Color
temperature: 6500K – Color rendering index: RA70 / RA90 (cut into high
rendering index filter) – Illuminance: 26000 Lux@10m – Luminous flux: 21000 Lm
– Light source lifespan: 20000H
COLOR – CMY infinite color mixing – CTO color temperature linear adjustment
(3000K-6500K) – 5 color chips + high-resolution finger + white light, can
realize two-way color rainbow, two-color step-bystep gradient (linear
movement), two-way rotation of color wheel, random color mode.
PATTERN – Rotating gobo wheel:7 kinds of glass patterns + white circle,
pluggable and replaceable, can realize
rotation, flowing water,shaking effects, the outer diameter of the gobo is
22.9mm, and the inner diameter of the gobo is 15mm. – Effect disc (water
texture)+CTO color temperature linear adjustment, which can achieve flowing
and shaking effects. – Eight-direction cutting: 4 pieces of gratings can
achieve fast and smooth cutting, and the eight cutting directions and angles
can be controlled separately, each single piece can achieve complete light
closure, and the entire cutting module can be rotated ±45º.
EFFECT – Prism: 4 prism, capable of bidirectional rotation. – Soft light
effect: adjustable independent soft light effect. – With electric aperture,
5-100% linear adjustment, with macro function and multi-effect change. –
Electronic dimming, 0-100% linear dimming, uniform light spot – Electronic
strobe speed is 1-25 times/second – LED refresh rate: 1000Hz ~ 25KHz
CONTROL – Control channel: 33CH36CH – Protocol: standard DMX512 , RDM , ArtNet
– Data connection: three-core or five-core signal input/output – Display: LCD
liquid crystal screen
-5-
SOFTWARE – Software upgrade via USB or DMX interface – Intelligent temperature
control to ensure LED life
X, Y AXIS MOVEMENT – X axis: 540° 8bit/16bit precision scanning – Y axis: 270°
8bit/16bit precision scanning
POWER AND POWER – Input voltage rangr: AC 100-240V ~ 50/60Hz – Maximum
power:520W – Power factor: 0.98
SIZE AND WEIGHT – size: 442mm×262mm×648mm – N.W: 26.3kg – Carton packing
(default): 495mm×365mm×755mm G.W: 32.1kg (include foldable clamp) – Flycase
Size(2 sets)730×575×845mm G.W95.3 Kg
OTHER – Protection class: Ip20 – Working environment: 0~ 40 – Maximum surface
temperature of the lamp body: 80°C – Maximum lamp current: 5.2A/110V;
2.6A/220V – Optional accessories: FAST LOCK
APPROVALS – The product implementation standard: GB 7000.1-2015 GB7000.
217-2008 – Approved certifications: CERoHs – The product complies with the
following EU directives: – Low Voltage Directive 2014/35/EU . EMC Directive
2014/30/EU
-6-
illuminationdiagram
Distance(m) 10
15
20
30
50
4°
53°
4° Lux Diameter(m)
53° Lux Diameter(m)
26000 0.62
300 11.38
11500 0.93
130 17.07
6500 1.24
75 22.76
2800 1.86
30 34.14
1000 3.1
12 56.9
2.1.Attachment And Size Attachment contents-Fig.1
Certificate of conformity
FAST LOCK (Optional)
power cord
X1
X1
X1
X2
x2
X1
X1
X2
Size-Fig.2
-7-
-8-
3.Color/Gobo/Prism
CMY-color wheel
white
C
3
Blue 1
2 Orange
white
M
3
Red 1
2 Green
white
Y3
Cyan 1
2 CRI
Pattern-Effect disc
CTO
Prism
-9-
4.Control Panel
1
2
7 3 4 85 6
1.Display: To show the various menus and the selected function. 2.Button:
OK confirmation key UP DOWN
To the left To the right
3.Socket version power input: connect the power supply. 4.Power output:
Connect the lamp power output adapter. 5.DMX inputloutput: Used for DMX512
connection, use 3/5 core XLR signal
cable toconnect console and lamps,And input/output DMX signal. 6.Art-net: The
information of the lamp can be transmitted to the main
controllerthrough the network cable, and the lamp can be controlled through
RJ45(optional). 7.Firmware upgrade: Used to upgrade the fixture’s firmware.
8.FUSE:10A.
-10-
5.Connection and control 5.1.Power supply connection
POWER in
out
The L terminal is connected with the brown line.
Watertight seal ring
in
POWER END
The ground wire is connected to the yellow-green wire
The N terminal is connected with the blue line.
Watertight seal ring
– The bus connecting the power supply must be installed by a qualified
professional technician. – After completing all the above operations and
ensuring that it is installed, you can power on the
lamp to operate.
-11-
5.2.DMX 512 Connection
DMX512 in
DMX-input 1- Shield 2 – Signal (-) 3 – Signal (+) 4 – Not connected 5 – Not
connected
in out
in SIGNAL END
DMX – output 1- Shield 2 – Signal (-) 3 – Signal (+) 4 – Not connected 5 – Not
connected
1. At last unit, the DMX cable has to be terminated with a terminator. Solder a 1200hm 1/4W resistor between pin 2(DMX-) and pin 3(DMX+) into a 3-pin XLR- plug and plug it in the DMX-output of the last unit. 2. Connect the unit together in a “daisy chain” by XLR plug cable from the output of the unit to the input of the next unit. The cable cannot be branched or split to a “Y” cable. DMX 512 is a very high-speed signal. Inadequate or damaged cables, soldered joints or corroded connectors can easily distort the signal and shut down the system. 3. The DMX output and input connectors are pass-through to maintain the DMX circuit, when one of the units’ power is disconnected. 4. Each lighting unit needs to have a DMX address to receive the data by the controller. The address number is between 1-512. 5. The end of the DMX 512 system should be terminated to reduce signal errors. 6. 3 pin XLR connectors are more popular than 5 pins XLR. 3 pin XLR: Pin 1: GND, Pin 2: Negative signal (-), Pin 3: Positive signal (+) 5 pin XLR: Pin 1: GND, Pin 2: Negative signal (-), Pin 3: Positive signal (+), Pin4, Pin5 not used.
-12-
6.How To Set The Unit
6.1.Main Function
Turn on the fixture, press the OK button to enter the menu mode, use the UP/DOWN buttons to find the menu, when the preset menu is shown on the display, press the OK button to confirm, use the UP/DOWN buttons to select a submenu, then press the OK button to save Settings, use the left button to return to the previous menu. The main functions are as follows:
Main menu I menu
II menu
III menu
menu
DMX SETTING
Address Channel mode
Input mode NoDMX State
Fixture times
Temperatures RDM info DMX live
Info
Version info
Fan Info
1-512
Standard 33 Extended 36
DMX 512
Artnet
Black
Hold
Power on time
LED on time
All time
LED TEMP
Drive TEMP
UID:0x3888XXXXXXXX
1.Pan
2.Pan fine
3…….
Display
Pan/Tilt
LED Gobo
module module
Blade module
Zoom module
InFan Voltage
OutFan Voltage
InFan1
InFan2
OutFan1
OutFan2
0 – 99999H 0 – 99999H 0 – 99999H
0 – 255 0 – 255
0 – 255 VX.XXX VX.XXX VX.XXX VX.XXX VX.XXX VX.XXX
GoboFan
FrameFan
Person
Pan/Tile Fan mode Display
Art-Net Dimmer Curve Led Preq Set
HeadFan
Pan invert
Tilt invert
Hight Brightness Silent
Super Silent
Language
Backlight time Intensity
Rotation
IP Address Mask Address Net Address Sub Net Address Universe Address Linear
Square 1(Default) Square 2 SCurve 1000 Hz (Default) 3600 Hz 7200 Hz 25000 Hz
OFF ON OFF ON
English Chinese Always Auto (30S) 0 – 100 Normal Rotate 180 Auto
xxx.xxx.xxx.xxx xxx.xxx.xxx.xxx xxx.xxx.xxx.xxx xxx.xxx.xxx.xxx xxx
-13-
Main menu
I menu
Manual Control
Manual
Reset
Test
Test all Test pan/tilt
Test effects
Fixture state
Service
Adjust
II menu
1.Pan 2.Pan fine
3…… Total reset Pan/Tilt reset Gobo reset Color reset Profile reset Focus
reset Effect reset Testing Testing Testing Memory IC Angle Sensor Pan Encodeer
Tilt Encoder Pan Tilt Zoom Focus Cyan Magenta Yellow RotGobo GoboRot Animation
Frame FrameRot Iris Prism Frost Pan Tilt …… Factory Reset
Reset timers
Factory
Update
Logo select
III menu
0 – 255 0 – 255
0 – 255
menu
OK/Reset/Error OK/Reset/Error OK/Reset/Error OK/Reset/Error OK/Reset/Error
OK/Reset/Error OK/Reset/Error OK/Reset/Error OK/Reset/Error OK/Reset/Error
OK/Reset/Error OK/Reset/Error OK/Reset/Error OK/Reset/Error OK/Reset/Error
OK/Reset/Error OK/Reset/Error OK/Reset/Error OK/Reset/Error 0 – 255 0 – 255 0
– 255 YES / NO Reset power on timers Reset led timers Reset all timers
Simple update
Whole update
YES/NO
YES/NO
YES/NO
Display
Pan/Tilt …
ALL
Display
Pan/Tilt
…
ALL
-14-
6.2.Channel Setting
Enter the MENU menu, select the Personal Settings function, select the channel
mode, press the OK button to confirm, you can use the up and down keys to
select:33 channels (default), 36channels, Press the OK key to enter the
selection confirmation and return to the previous menu.
6.36.A.3dAdrdedsrsesSseSttientgting
Enter MENU, select the DMX setting function, select the address code setting,
press the OK button to confirm, the current DMX address will be displayed on
the display. Use the up/down buttons to select addresses 001~512, and press
the OK button to save. Press the OK button to return to the previous menu.
Please refer to the following diagram to address your DMX512 channel for the first 4 units.
Channel mode 33 CH
Unit 1 Address
1
Unit 2 Address
34
Unit 3 Address
67
Unit 4 Address
100
36 CH
1
37
73
109
-15-
6.4.DMX 512 Configuration
Please control the fixture by referring to the configurations below
33 Channel 1 2 3 4 /
36 Channel 1 2 3 4 5
5
6
DMX 0–255 0–255 0–255 0–255 0–255
0–9 10–19 20–29 30–39 40–49 50–59 60–69 70–79 80–89 90–99 100–109 110 –119
120–129 130–139 140–149 150–159 160–169 170–177 178–185 186–193 194–199
200–204 205–209 210–214 215–219 220–229 230–239 240–255
Function Pan positioning Fine Pan positioning Tilt positioning Fine Tilt positioning Speed pan/tilt DeviceSet(Hold 3s No function Fan high speed Fan auto speed Fan slow speed Reset Pan&Tilt Reset CMY Reset Gobo Reset Frame Reset Head Reset other(except P&T) Reset All No function No function Pan invert on Pan invert off Tilt invert on Tilt invert off LED frequency 1kHz LED frequency 3.6kHz LED frequency 7.2kHz LED frequency 25kHz Dimmer curve linear Dimmer curve square Dimmer curve inv–square Dimmer curve “S” Dimmer fast Dimmer smooth No function
6
7
0–255 Cyan
7
8
0–255 Magenta
8
9
0–255 Yellow
Virtual ColorWheel
0–5
CMY enable
6–23
Red
24–41 Green
42–59 Blue
9
10
60–77 Orange
78–95 light blue
96–113 CRI
114–133 CMY enable
134–194 virtual Colorwheel CW slow to fast
195–255 virtual Colorwheel CCW fast to slow
RotgoboWheel
0–9
Open
10–19 RotGobo1
20–29 RotGobo 2
30–39 RotGobo 3
40–49 RotGobo 4
-16-
Note
33 Channel 36 Channel
10
11
11
12
12
13
13
14
14
15
15
16
16
17
17
18
18
19
19
20
20
21
21
22
22
23
23
24
24
25
DMX 50–59 60–69 70–79 80–87 88–95 96–103 104–111 112 –119 120–127 128–135
136–139 140–194 195–249 250–255
0–127 128–189 190–193 194–255
0–255
0 –127 128–255
0–255 0–255 0–255 0–255 0–255 0–255 0–255 0–255 0–255
0 –10 11–20 21 –30 31 –40 41 –50 51 –60 61 –70 71 –80 81 –255
0–127 128–159 160–191 192–255
0–9 10–63 64–127
Function RotGobo 5 RotGobo 6 RotGobo 7 RotGobo1shake,slow to fast
RotGobo2shake,slow to fast RotGobo3shake,slow to fast RotGobo4shake,slow to
fast RotGobo5shake,slow to fast RotGobo6shake,slow to fast RotGobo7shake,slow
to fast Open RotGoboWheel CW fast to slow RotGoboWheel CCW slow to fast Random
Gobo GoboRot GoboRot indexing 0°– 360° RotGobo CW fast to slow Stop RotGobo
CCW slow to fast CTO
Effect wheel Animation index Animation rotation BladeA position1 BladeA
position2 BladeB position1 BladeB position2 BladeC position1 BladeC position2
BladeD position1 BladeD position2 Frame Rot Framing Macro No function
Square
Rectangle
Triangle
Trapezoid
Sector
Semi-circle Parallelogram No function
Iris
Iris Indexing
Slow close fast open ; slow–fast
Fast close slow open; slow– fast
Slow close slow open ;slow–fast Prism&PrismRot Prism out
Prism In & indexing
Forwards prism rotation from slow to fast
-17-
Note
33 Channel 36 Channel
25
26
26
27
27
28
/
29
28
30
/
31
29
32
30
33
31
34
32
35
33
36
DMX 128–191 192–207 208–223 224–239 240–255
0–255 0–255 0–255 0–255 0–255
0–9 10–19 20–68 69–79 80–128 129–139 140–188 189–255 0–255
0–255
0–127 128–158 159–190 191–225 226–255
0–255
Function Backwards prism rotation from fast to slow
prism flickered 90°
prism flickered 180°
prism flickered 270°
prism flickered 360°
Frost
Focus8bit
FocusFine16bit
Zoom8bit
ZoomFine16bit Strobe Strobe closed Strobe open Normal strobe effect slow to
fast Strobe open Pulse strobe Strobe open Random strobe Strobe open
Dimmer
Dimmer Fine
Auto Focus Auto Focus Disable 10m Auto Focus Enable 15m Auto Focus Enable 20m
Auto Focus Enable 30m Auto Focus Enable Auto FocusFine
Note
-18-
7.Electrical Connection Diagram
-19-
8.Troubleshooting
The following are common faults of lamps and corresponding solutions. Faults
that cannot be repaired by yourself should be handled by professionally
qualified personnel. Disconnect the power supply to the lamp during
maintenance!
The light source is not bright – Check that a suitable light source is
installed for the luminaire. – Check whether the power supply connection of
the lamp or the control switch is in poor contact. – Check whether the light
source has reached the end of its service life or is damaged, and replace it
with a high-quality light source of the same specification. – Measure whether
the power supply is insufficient. – Check whether the light source has not
cooled down completely due to abnormal operation. Let the lamp cool down for
more than 15 minutes to allow the light source to cool down. After returning
to the normal startup range, turn the power on again and it can be used
normally. – Check whether the DMX512 controller sends a command to turn on the
light source. – Check whether the light source and trigger circuit are
disconnected or defective. – Check whether the wiring terminals on the
internal trigger are in poor contact and tighten the plug. – Check the “Fan
Speed and Voltage” in the “Basic Information” menu to see if the speed of
FAN1/FAN2/FAN3 is above 500RPN. If it is below 500RPM, the light source will
not light up. Replace the fan with the same specification. – Check whether the
over-temperature protection temperature switch inside the lamp is damaged. Go
to the menu “Basic Information” and select “Equipment Temperature” to check –
whether the temperature measuring plate shows that the temperature is too high
or there is no temperature display. The beam appears dim and uneven – The
light source may have reached the end of its service life and does not emit
enough light. Replace it with a light source of the same specification. –
Check whether there is dust accumulated in the optical part and clean it. –
Measure whether the power supply is insufficient. – Finely adjust the screw
device used to change the height of the lamp until the ideal light is
achieved. Enter the menu “Service Options” and select “Calibration” to enter
color and pattern adjustment, which can be adjusted to the center. The
projected image is blurry – Check whether the DMX512 controller channel value
corresponding to the electronic focus system is suitable for the current
projection distance. – Check whether the mechanical part of the focusing
system is stuck, remove the dust and add antifreeze and temperature-resistant
lubricating oil. The light source of the lamp works intermittently – Check
whether the fan is running normally or is blocked by dust and paper debris. –
Check whether the inlet and outlet cooling air vents are blocked by dust. –
Check whether the lamp has reached the end of its service life.
-20-
– Check whether the power supply is insufficient, and whether the power switch
and wiring are in poor contact or aging. – Check whether the over-temperature
protection temperature switch inside the lamp is damaged. Although it emits
light, the lamp does not accept instructions from the controller – Check
whether the digital start address value and function options of the lamp are
correct. – Check whether the connection of the communication control line is
correct. The communication line is too long or has been interrupted. – Check
whether the control equipment fails and whether the signal amplifier connected
in series fails. – Check whether the communication line is too long or if
other devices interfere with each other. – Optimize wiring, shorten the length
of control signal lines, and route high-voltage and low-voltage lines
separately – Add signal amplifier isolator. – The signal line is made of high-
quality shielded twisted pair (impedance characteristic is 75), and the signal
terminal resistor is connected at the end of the lamp. – Check that the
circuit board communication IC or CPU is burned out because the bulb performs
an abnormal operation when it is not completely cooled, causing the
instantaneous ultra-high voltage leakage generated by the trigger, and replace
the PCB board. The lamp cannot be started – Check whether the power supply
parameters match the lamps. – Check whether the fuse at the light fixture’s
power input is blown. – Check that the lamp has poor contact or falls off due
to extrusion deformation, vibration of internal parts, moisture, etc. during
long-distance transportation. – Check whether the internal wires and
connectors of the lamp are desoldered or loose. – Check whether the electrical
components of the lamp (such as power switch, transformer, ballast, capacitor,
varistor, filter, power supply PCB board, motor control PCB board, etc.) are
loose, short-circuited, burned out, etc. Some functions of the lamp cannot
accept controller instructions – Check whether the control device sends
correct action instructions for these functions. – Check whether the
mechanical parts corresponding to these functions are loose or deformed. –
Check whether the motor sockets corresponding to these functions are loose or
the corresponding driver chips are burned out. – Check whether the motor wires
corresponding to these functions are broken at the corners. – Check whether
the motors corresponding to these functions are damaged. During operation, the
x or Y direction of the lamp does not move normally – Click the previous step
to check one by one. – Check whether the corresponding drive belts in the X
and Y directions of the lamp are detached or broken. – Check whether the data
feedback receiver (photoelectric sensor) corresponding to the X and Y
directions in the lamp is damaged. – Restart the computer and reset it once.
-21-
9.Fixture Cleaning
It is absolutely essential that the fixture is kept clean to ensure the
maximum light-output and allow the fixture to function reliably throughout its
life. The fixture must be cleaned regularly to avoid dust, dirt and smoke-
fluid residues building up on or within the fixture. The cleaning frequency
depends on the application environment. Clean the fixture immediately if the
dust enters it to avoid damage to the optical lens due to excessive dust. A
soft lint-free cloth moistened with any good glass cleaning fluid is
recommended, under no circumstances should solvents be used. Always dry the
parts carefully. * Clean the external optical lens at least every 20 days and
the internal optical lens every 30 days.
CAUTION Disconnect from mains before starting maintenance operation.
10.Duty exonerative and copyright protectio
- Light source belongs to consumption products, not within the scope of warranty. The manufacturer shall not bear any responsibility for any damage caused by failure to
operate in accordance with this instruction. All the information in this manual shall be interpreted by the manufacturer. All the information in this manual shall not be copied without permission. The data contained in this statement are subject to change in the future without prior notice.
-22-
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>