Shinko RD71JE5 Infrared Temperature Sensor Instruction Manual
- June 3, 2024
- Shinko
Table of Contents
Shinko RD71JE5 Infrared Temperature Sensor
Preface
Thank you for purchasing our Infrared Temperature Sensor RD-715-HA. This manual contains instructions for the mounting, functions, operations and notes when operating the RD-715-HA. To ensure safe and correct use, thoroughly read and understand this manual before using this sensor. To prevent accidents arising from the misuse of this sensor, please ensure the operator receives this manual.
Caution
- This sensor should be used in accordance with the specifications described in the manual.
- If it is not used according to the specifications, it may malfunction or cause a fire.
- Be sure to follow all of the warnings, cautions, and notices. If they are not observed, serious injury or malfunction may occur.
- The contents of this instruction manual are subject to change without notice.
- Care has been taken to ensure that the contents of this instruction manual are correct, but if there are any doubts, mistakes or questions, please inform our sales department.
- This instrument is designed to be used in close proximity to the target object. Measures must be taken to ensure that the operator cannot touch power terminals or other high-voltage sections.
- Any unauthorized transfer or copying of this document, in part or in whole, is prohibited.
- Shinko Technos Co., Ltd. is not liable for any damage or secondary damage(s) incurred as a result of using this product, including any indirect damage.
Safety Precautions (Be sure to read these precautions before using our
products.)
The safety precautions are classified into categories: “Warning” and
“Caution”. Depending on the circumstances, procedures indicated by Caution may
result in serious consequences, so be sure to follow the directions for usage.
- Procedures that may lead to dangerous conditions and cause death or serious injury, if not carried out properly.
- Procedures that may lead to dangerous conditions and cause superficial to medium injury or physical damage or may degrade or damage the product, if not carried out properly.
Warning
- To prevent an electrical shock or fire, only Shinko or other qualified service personnel may handle the inner assembly.
- To prevent an electrical shock, fire or damage to the instrument, parts replacement may only be undertaken by Shinko or other qualified service personnel.
Safety Precautions
- To ensure safe and correct use, thoroughly read and understand this manual before using this instrument.
- This instrument is intended to be used for industrial machinery, machine tools and measuring equipment. Verify correct usage after purpose-of-use consultation with our agency or main office.(Never use this instrument for medical purposes with which human lives are involved.)
- External protection devices such as protective equipment against excessive temperature rise, etc. must be installed, as a malfunction of this product could result in serious damage to the system or injury to personnel. Proper periodic maintenance is also required.
Caution with Respect to Export Trade Control Ordinance
To avoid this instrument from being used as a component in, or as being
utilized in the manufacture of weapons of mass destruction (i.e. military
applications, military equipment, etc.), please investigate the end users and
the final use of this instrument. In the case of resale, ensure that this
instrument is not illegally exported.
Model
How to Read the Model Label
The model label is attached to the surface of the electronics (Status
indicator side). Lot No. the label is attached to the reverse side of the
electronics.
Target Objects
- Non-problematic objects Food, paper, plastics, cloth, leather, cigarettes, medicine, chemicals, rubber, asphalt, coal, etc.
- Difficult objects Plated lustrous metals, uncoated or unpainted metals, etc.
- Slightly problematic objects
- Low lustrous metals, thin transparent plastics, etc.
- If Ensure the installation location corresponds to the following conditions. measurement is difficult, black body tape can be used to raise emissivity.
Installation
Ensure the installation location corresponds to the following conditions.
- The sensing head should be kept as close as possible to the object.
- The ambient temperature of the sensing head should not exceed 120 (248 ). The ambient temperature of the electronics should not exceed 80 (176 ).
- The sensor lens should be protected from being covered with powder, dust, etc.
- Use an air purge collar (ASAP, sold separately) when using this sensor in a place where a lot of fumes, dust or moisture is present. (Airflow: 2 to 10 liter/sec)
- Install this sensor away from electrical noise, motors or generators.
- For the mounting method of the mounting bracket (TFB, sold separately), see pages 3, 4. For the mounting method of the Air purge collar (ASAP, sold separately), see pages 4, 5.
Target Spot Size versus Distance from Sensing Head
- (Fig. 3.1-1) shows the relationship between the target spot size and distance from the sensing head. (Fig. 3.1-1 is not to scale.)
- Take these values into consideration when installing the sensor. Field of view D:S = 15:1
Mounting
There are 3 methods for mounting the sensing head.
- Direct mounting
- Mounting when the mounting bracket (TFB, sold separately) is used
- Mounting when the air purge collar (ASAP, sold separately) is used
Direct Mounting
There are 3 methods for mounting the sensing head.
- Direct mounting
- Mounting when the mounting bracket (TFB, sold separately) is used
- Mounting when the air purge collar (ASAP, sold separately) is used
Direct Mounting
The sensing head is threaded (M12 x 1) for direct mounting.
The sensing head is threaded (M12 x 1) for direct mounting. If the mounting bracket is used, the sensing head can be easily adjusted. Mounting bracket (TFB) dimensions (Scale: mm)
The mounting procedure is shown below.
- Fix the mounting bracket at the desired site using a screw (M3 size – not included).
- Remove the hexagonal nut (SW 14) from the sensing head, and pass the sensing head through the mounting bracket. Secure it using the hexagonal nut.
Mounting When the Air Purge Collar (ASAP, sold separately) is Used
- The air purge collar is used to suppress rises in temperature of the sensing head, and to keep fumes, dust, gases, and other contaminants away from the lens. The mounting bracket (TFB, sold separately) is also necessary
- Airflow: 2 to 10 liters/minute
- Use clean, oil-free compressed air.
- Fix the mounting bracket (TFB) at the desired site using a screw (M3 size – not included).
- Pass the air purge collar through the mounting bracket, and secure it using the hexagonal nut.
Attach the tube and air pump to the air purge collar. Refer to the tube size and air pump specifications recommended below. Recommended tube size: Inside diameter: 4 mm; Outside diameter: 6 mm Recommended air pump: The air pump should fit the tube size and deliver a discharge air flow rate corresponding to the air purge collar (2 to 10 liters/minute).
Wiring
Turn OFF the power supply to the indicator/controller before wiring. Working on or touching the terminal with the power switched ON may result in severe injury or death due to electrical shock. When using the sensor in an environment where electrical noise is present, use a shielded wire, and connect it to the ground terminal of the indicator/controller. If the indicator/controller does not have a ground terminal, connect to the ground terminal of the control panel. The wiring example for the RD-715-HA, power supply (RDP-24) and digital indicating controller (ACS-13A- /A) is shown below.
- White: Power supply Loop current (+ side)
- Brown: Power supply Loop current (- side)
- Black: Shielded wire
- Green: Not used (Do not connect anything.)
- Yellow: Not used (Do not connect anything.)
- Emissivity can be set on the ACS-13A- /A Digital Indicating Controller.
- For details, refer to the Instruction Manual for the ACS-13A- /A.
- If a fixed emissivity of 0.950 is used, any indicator/controller can be used.
Measurement
- If the ambient temperature is rapidly changing, leave the sensor for more than 20 minutes as it is, then measures the temperature.
- Do not measure temperature near a large magnetic field (for example Arc welding machine, induction heater, etc.). Measurement errors will be caused due to electromagnetic disturbance.
After completing the installation for the target object and wiring, start the operation following the procedures below.
- Turn the power to the sensor ON (RDP-24).
- Turn ON the power to the indicator/controller (ACS-13A- /A).
- Measure the temperature.
Status indicator of the electronics
Specifications
Performance
Output
Other
External Dimensions (Scale: mm)
Troubleshooting
If problems arise, please check the following content.
Inquiries
For any inquiries about this unit, please contact our agency or the vendor
where you purchased the unit after checking the model and lot number.
- Model: RD-715-HA
- Lot No.: 072013
In addition to the above, please let us know the details of the malfunction, or discrepancy, and the operating conditions.
SHINKO TECHNOS CO., LTD. OVERSEAS DIVISION
2-5-1, Senbahigashi, Minoo, Osaka, 562-0035, Japanhttps://shinko-
technos.co.jp/e/ overseas
@shinko-technos.co.jp Tel: +81-72-727-6100
Fax: +81-72-727-7006