FIELDMANN FVC 2011-EK FVC 2013-EK Submersible Pump User Manual
- September 3, 2024
- FIELDMANN
Table of Contents
- FVC 2011-EK FVC 2013-EK Submersible Pump
- GENERAL SAFETY REGULATIONS
- MACHINE DESCRIPTION AND INCLUDED CONTENTS
- PUTTING INTO OPERATION
- OPERATING INSTRUCTIONS
- MAINTENANCE AND STORAGE
- TECHNICAL SPECIFICATIONS
- WHAT TO DO “WHEN…”
- DISPOSAL
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Submersible Pump
USER’S MANUAL
FVC 2011-EK
FVC 2013-EK
FVC 2011-EK FVC 2013-EK Submersible Pump
User Manual
FVC 2011-EK FVC 2013-EK Submersible Pump
Thank you for purchasing this submersible pump. Before you start using it, please, carefully read this user ‘s manual and save it for possible future use.
GENERAL SAFETY REGULATIONS
Important safety notices
Carefully unpack the product and take care not to throw away any part of the
packaging before you find all the parts of the product.
Read all warnings and instructions. Not following warnings or instructions may
lead to injury by electrical shock, a fire and/or serious injuries.
ATTENTION: Protect yourself against electrical shock!
Packaging
The device is located in a package that prevents damage during transport. This
package is a resource and so can be handed over for recycling.
Operating instructions
Before you start working with the submersible pump, read the following safety
instructions and user’s manual.
Learn about all parts and the correct use of the device. Keep the user’s
manual in a safe place where it can be easily retrieved for future use. If you
hand over the device to somebody else, do so together with the user’s manual.
Following the instructions in the included user’s manual is a prerequisite for
safe use of the garden machine. The user’s manual also contains operating,
maintenance and repair instructions.
The manufacturer takes no responsibility for accidents or damages resulting
from not following the instructions in this manual.
MACHINE DESCRIPTION AND INCLUDED CONTENTS
Carefully take the machine out of the packaging and check whether all the following parts are present:
Machine description (see pic. 1)
‘
- Pump body
- Power cord with electrical plug
- Hose connection with option to connect to a 1″/2″ hose
- Pump tube bend
- Hose connection with the pump tube bend – assembled
- Switching float
- Height setting for the switching float
Supplied contents
Submersible pump
Operating instructions
Hose connection with pump tube bend
If there are parts missing or they are damaged, please contact the vendor from whom you bought the machine.
PUTTING INTO OPERATION
Installation
Submersible pumps are installed as follows:
in a permanent position with a rigid pipe.
in a permanent position with a flexible pipe.
You should never install the pump by hanging it on the outlet hose or power
cord without additional support.
The submersible pump must be hung on a holder, or it must be placed on the
bottom of the tank.
For the pump to function correctly the bottom part of the tank must be
protected against any kind of dirt (applies to clean water pumps) and against
any larger residue (for the size of dirty material see the technical
specifications of the individual models).
If the water level declines too much, any residue in the pumping pit will
quickly dry out and prevent the pump from starting again. It is therefore
essential to regularly inspect the submersible pump (by starting it).
The float is set up in such a way that the pump may be started immediately.
After carefully reading these instructions you can prepare your pump for
operation, however, keep the following points in mind:
Check that the pump is standing on the bottom of the tank.
Check that the outlet hose has been attached correctly.
Check that the electrical connection is 230 V ~ 50 Hz.
Check that the power socket is in good condition.
Ensure that the moisture from the water can never get to the electrical power
source.
Prevent the pump from running empty.
Before putting the pump into operation, please check the following points:
The switching float is installed in such a way that it is possible to reach the
activation level or the shut off level with only a small amount of force.
After checking this installation, place the pump into a tank with water and
carefully lift the switching float by hand and then put it down again. During
this activity watch that the pump has started and then turned itself off.
Ensure that the distance between the switching float and the pawl holder is not
too small. It is not possible to guarantee correct operation when the gap is
too small.
As soon as you set the switching float, check that it is not touching the
underlay before the pump turns off.
The activity position of the switching float can be set by adjusting the float
in the holder of the pawl.
ATTENTION: Danger of running when empty.
Note: The tank for the pump should have the minimum dimensions of 40 × 40
× 50 cm (height × width × depth), for the float to freely move with the switch.
Connecting to the mains
Your new submersible pump is equipped with a power plug, preventing discharge,
meeting strict norms. The pump is designed to be connected to a safety power
socket 230 V ~ 50 Hz. Check that it is in perfect condition. Insert the plug
into the socket and the pump is ready for use.
ATTENTION: If the power cord or power plug are in any way damaged by an
external action, do not repair the power cord and contact an authorised
service centre!
ATTENTION: This repair should only be performed by an authorised service
centre.
OPERATING INSTRUCTIONS
Purpose of use
This pump may be used anywhere, where you wish to transfer water from one
location to another, e.g. at home, agriculture, gardening, plumbing and for
many other applications.
This product is designed for private household use.
It is not suitable for professional use.
The submersible pump is suitable for work with water in a water distribution
system and for chlorinated pool water.
It is not suitable for work with waste water in sewage systems, salt water,
aggressive or easily combustible substances, for work in food processing or as
a pump for water jets on garden ponds.
It is not designed for pumping drinking water!
Instructions for use
ATTENTION: Before setting up the machine or carrying out maintenance on
the machine, or if the electric power cable has become jammed or is damaged,
always disconnect it from the electric power socket!
Before using the submersible pump, please fi rst carefully read all the safety
instructions and instructions for use for the pump. Only after reading these
instructions will you be able to safely and reliably use all the functions of
the pump. You must conform to all local regulations in force in your country.
These regulations are effective together with the particulars specifi ed in
these instructions.
ATTENTION: If you will be using the pump near pools or garden ponds, or
in their protective zone, the electrical grid must be equipped with a circuit
breaker. The pump must not be used, if there are people in the pool or garden
pond! Also do not use it if there are fish or other living creatures in the
pool or garden pond. Contact an expert company for installation.
The submersible pump is designed to pump water at a maximum temperature of 35
°C.
The pump must not be used for other liquids, particularly motor oils, cleaning
agents and other chemical products!
Electrical safety
The pump can be connected to any power plug installed according to given
norms.
The plug must be powered at 230 V ~ 50 Hz.
ATTENTION – Important for the protection of your personal safety. Before fi rst starting your new submersible pump have a professional check the following items:
- Grounding
- Neutral conductor
- The current circuit breaker must conform to energy safety norms and must function perfectly.
- The electrical connection must be protected against moisture.
- If there exists a danger of the electrical connection being fl ooded, it must be moved higher.
- Under all circumstances prevent the circulation of aggressive liquids and coarse materials.
- The submersible pump must be protected against frost.
- The pump must be protected against running empty.
- Prevent children from accessing parts of the pump by appropriate measures.
MAINTENANCE AND STORAGE
This submersible pump is approved as a maintenance-free, high quality product undergoing several final inspections. We recommend you perform regular inspections and maintenance, which will ensure a long lifetime and continuous performance.
ATTENTION: Disconnect the power source before performing any maintenance.
Maintenance
If the pump is regularly moved during operation, it should be rinsed out
with water after each use with clean water.
If the pump is permanently installed, the working order of the switching
float should be checked every 3 months.
Any fibrous deposits that could deposit themselves inside the pump,
should be removed using a current of water.
Mud should be cleaned from the floor of the pumping pit every 3 months.
** Remove deposits on the float using clean water.
Cleaning the pump impeller**
If an excessive amount of debris accumulates in the body of the pump, flush the
pump out with clean water.
TECHNICAL SPECIFICATIONS
| FVC 2011-EK| FVC 2013-EK
---|---|---
Voltage/Frequency| 230 V~50 HZ| 230 V ~ 50 HZ
Power input| 250 W| 400 W
Maximum transferred amount| 5000 l/h| 7500 l/h”
Maximum delivery| 6 m| 5 m
Maximum submersible depth| 5 m| 4 m
Maximum temperature of the media| 35 °C| 35 °C
Maximum value of solid particles in the media| Dia. 5 mm| Dia. 35 mm
Height of the switching point: On| Approx. 50 cm| Approx. 50 cm
Height of the switching point: Turned off| Approx. 5 cm| Approx. 5 cm
WHAT TO DO “WHEN…”
When… | Causes | Repairs |
---|---|---|
The pump does not start | – No power supply | |
– The float does not switch | – Check the power supply |
– Move the float to a higher position
Not flowing| – The suction sieve is clogged
– The pressure hose is bent| – Flush out the suction sieve with a current of
water
– Straighten the hose
The pump does not turn off| – The float cannot fall lower| – Place the pump
correctly on the floor of the tank
Insuffi cient flow| – The suction sieve is clogged
– Lowered pump capacity due to dirty and silted water| – Clean the suction
sieve
– Clean the pump and flush the hose with clean water
The pump turns off after a short time| – The temperature fuse stops the pump
due to dirty water
– The water is too hot. The temperature fuse stops the pump| – Disconnect
the power plug. Clean the pump and the pumping pit
– Check that the maximum water temperature of 35 °C is not exceeded
Note: Not covered by warranty:
Damage to the rotating mechanical gasket caused by running the pump empty, or
by foreign objects in the water
Blocking of the running wheel by foreign objects
Damage during transport
Damage caused by unprofessional alterations by persons
DISPOSAL
INSTRUCTIONS AND INFORMATION REGARDING THE DISPOSAL OF USED PACKAGING
MATERIALS
Dispose of packaging material at a public waste disposal site.
DISPOSAL OF USED ELECTRICAL AND ELECTRONIC APPLIANCES
The meaning of the symbol on the product, its accessory or packaging indicates
that this product shall not be treated as household waste. Please, dispose of
this product at your applicable collection point for the recycling of
electrical & electronic equipment waste. Alternatively in some states of the
European Union or other European states you may return your products to your
local retailer when buying an equivalent new product. The correct disposal of
this product will help save valuable natural resources and help in preventing
the potential negative impact on the environment and human health, which could
be caused as a result of improper liquidation of waste. Please ask your local
authorities or the nearest waste collection centre for further details. The
improper disposal of this type of waste may fall subject to national
regulations for fines.
For business entities in the European Union
If you wish to dispose of an electrical or electronic device, request the
necessary information from your seller or supplier.
Disposal in other countries outside the European Union
If you wish to dispose of this product, request the necessary information
about the correct disposal method from local government departments or from
your seller.
This product meets all the basic EU regulation requirements that relate to it.
Changes to the text, design and technical specifications may occur without
prior notice and we reserve the right to make these changes.
FAST CR, as.
U Sanitasu 1621, 251 01 Ridany, Czech Republic
tel: +420 323 204 11+, fax: +420 323 204710
EU DECLARATION OF CONFORMIT
Product / brand: | Submersible Pump / FIELDMANN |
---|---|
Type / model: | FVC 2011-EK as factory model Q1CP-250B |
AC 230 – 240 V, 50Hz, 250W, Class I, IPX8
Manufacturer:| FAST ČR, a.s.
U Sanitasu 1621, 251 01 Říčany, Czech Republic
VAT no: CZ24777749
This declaration of conformity is issued under the sole responsibility of the
manufacturer.
Person in charge of completing the technical documentation: FAST ČR, a.s.
The object of the declaration described above is in conformity with the
relevant Union harmonization legislation:
Directive MD 2006/42/EC
Directive EMC 2014/30/EU
Directive RoHS 2011/65/EU
The relevant harmonized standards and the other technical specifications:
EN 60335-1:2012+A11+A13+A1+A14+A2+A15
EN IEC 55014-1:2021
EN IEC 60335-2-41:2021+A11
EN IEC 55014-2:2021
EN 62233:2008
EN IEC 61000-3-2:2019+A1
EN 61000-3-3:2013+A1
Place of issuance: Prague Name:
Petr Uher – Responsible Person
Date of issuance: 30. 08. 202
Signature: EU DECLARATION OF CONFORMIT
FAST CR, as.
U Sanitasu 1621, 251 01 Ridany, Czech Republic
tel: +420 323 204 11+, fax: +420 323 204710
Product / brand: | Submersible Pump / FIELDMANN |
---|---|
Type / model: | FVC 2011-EK as factory model Q1CP-250B |
AC 230 – 240 V, 50Hz, 250W, Class I, IPX8
Manufacturer:| FAST ČR, a.s.
U Sanitasu 1621, 251 01 Říčany, Czech Republic
VAT no: CZ24777749
This declaration of conformity is issued under the sole responsibility of the
manufacturer.
Person in charge of completing the technical documentation: FAST ČR, a.s.
The object of the declaration described above is in conformity with the
relevant Union harmonization legislation:
Directive MD 2006/42/EC
Directive EMC 2014/30/EU
Directive RoHS 2011/65/EU
The relevant harmonized standards and the other technical specifications:
EN 60335-1:2012+A11+A13+A1+A14+A2+A15
EN IEC 55014-1:2021
EN IEC 60335-2-41:2021+A11
EN IEC 55014-2:2021
EN 62233:2008
EN IEC 61000-3-2:2019+A1
EN 61000-3-3:2013+A1
Place of issuance: Prague Name:
Petr Uher – Responsible Person
Date of issuance: 30. 08. 202
Signature:
Read User Manual Online (PDF format)