Metra MEW Wristband Capturer Instruction Manual
- September 3, 2024
- Metra
Table of Contents
MEW Wristband Capturer
“`html
Specifications:
- Manufacturer: Metra inzeniring d.o.o.
- Trade Mark: Metra MEW System
- Model/Type ref.: Metra Wristband Capturer
- Part Number: 1389 2ABT80006P1389
- Year of Construction: 2019
Product Description:
Metra Wristband Capturer is a retaining module for Metra RFID
wristbands. It is integrated into different Metra MEW products such
as Tripod Turnstile and Turnstile Access Terminal.
The RFID ISO reader reads ISO 15693, ISO 14443A, ISO 14443B, and
Mifare compatible RFID media. The Metra Wristband Capturer grants
the exit signal only when the ticket is successfully erased and
retained, reducing system operation costs and chances of fraud.
Connections:
There is a single connector dedicated to power and data (LIN)
connection. Pay attention not to mix MEW and CAN WBC
connection.
Regulated DC power supply is required for proper operation.
Connect the device with the supplied cable and 4-pin connector to
the control unit that controls the operation of the entire
device.
Operating Indicator:
When the unit is running in idle mode, the Metra logo on the
front panel blinks in Metra invite rhythm.
Usage Instructions:
-
Connect the device to a regulated DC power supply using the
provided cable and 4-pin connector. -
Ensure proper connection to the control unit to manage device
operation. -
Make sure the RFID wristband is successfully read by the
capturer before granting exit signal.
FAQ:
Q: What RFID media does the Metra Wristband Capturer read?
A: The capturer reads ISO 15693, ISO 14443A, ISO 14443B, and
Mifare compatible RFID media.
Q: What is the purpose of the ticket retain feature?
A: The ticket retain feature allows for the re-use of various
tickets, reducing system operation costs and chances of fraud.
“`
smarter locking
Metra Wristband Capturer Technical Manual MEW edition
smarter locking
TABLE OF CONTENTS
1 REGULATORY INFORMATION …………………………………………………………………………………………………… 3 2 PRODUCT
DESCRIPTION ………………………………………………………………………………………………………….. 4 3 CONNECTIONS
……………………………………………………………………………………………………………………….. 4
Control Device connection ……………………………………………………………………………………………….. 5 Control
Device connector pin out details ……………………………………………………………………………. 5 4 OPERATING
INDICATOR……………………………………………………………………………………………………………5 5
Signalization……………………………………………………………………………………………………………………………6 6 DIP SWITCH
SETTINGS …………………………………………………………………………………………………………….. 6 Special modes of
operation ………………………………………………………………………………………………. 6
TEST mode of operation (SW1) ………………………………………………………………………………….. 7 Silicone
wristbands operation (SW2) ………………………………………………………………………….. 7 Debug message
(SW3) ………………………………………………………………………………………………. 7 Automatic capturing (SW4)
……………………………………………………………………………………….. 7 7 MOUNTING
INSTRUCTIONS………………………………………………………………………………………………………7 8 TECHNICAL DATA
……………………………………………………………………………………………………………………. 9
Metra Wristband Capturer – Technical Manual ©2021Metra inzeniring d.o.o. All Rights reserved. No part of this manual may be reproduced in any form or by any means without prior written permission of Metra inzeniring d.o.o. The contents of this manual are subject to change without notice. All efforts have been made to ensure the accuracy of the contents of this manual, however, should any errors be detected, Metra inzeniring would greatly appreciate being informed of them. Metra inzeniring d.o.o. can assume no responsibility for any errors in this manual.
© Metra 2021, All Rights reserved
[rev.2 – 15092021] The content of this document is subject to change without notice
Page 2
smarter locking
1 REGULATORY INFORMATION
Manufacturer:
Trade Mark: Model/Type ref.: Part Number: Includes FCC ID: Year of
Construction:
Metra inzeniring d.o.o. IOC Trzin Spruha 19 SI-1236 Trzin, Slovenia Metra MEW System Metra Wristband Capturer 1389 2ABT80006P1389 2019
phone: +386 1 56 10 740 fax: +386 1 56 10 744 web: www.metra.si
© 15th September 2021 Metra inzeniring d.o.o. All Rights reserved. The contents of this document are subject to change without notice.
This product is in conformity with the essential requirements and other
relevant requirements of the following EU Directives: · RoHS Recast (RoHS2)
Directive 2011/65/EU of the European Parliament and of the Council on the
restriction of the use of certain hazardous substances in electrical and
electronics equipment. · The Electromagnetic Compatibility (EMC) Directive
2014/30/EU ensures that electrical and
electronic equipment does not generate, or is not affected by, electromagnetic
disturbance.
Environmental Information for EU customers WEEE Directive Statement: This symbol indicates the product is in conformity with the protection requirements of European Council Directive 2012/19/EU. It requires that products marked with this symbol must not be disposed of with unsorted municipal waste. This product must be disposed of separately from household waste via designated collection facilities appointed by local authorities. Please contact your local authorities or waste disposal service for more detailed information.
This product includes “Metra Wristband Collector” FCC ID 2ABT80006P1389. This
device complies with part 15 of the FCC Rules. Operation is subject to the
following two conditions: (1) This device may not cause harmful interference,
and (2) this device must accept any interference received, including
interference that may cause undesired operation.
This device has been tested and found to comply with the limits for a Class B
digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates uses and can radiate radio
frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and
on, the user is encouraged to try to correct the interference by one or more
of the following measures: · Reorient or relocate the receiving antenna. ·
Increase the separation between the equipment and receiver. · Connect the
equipment into an outlet on a circuit different from that to which the
receiver is connected. · Consult the dealer or an experienced radio/TV
technician for help. Any Changes or modifications not expressly approved by
the party responsible for compliance could void the user’s authority to
operate the equipment.
© Metra 2021, All Rights reserved
[rev.2 – 15092021] The content of this document is subject to change without notice
Page 3
smarter locking
2 PRODUCT DESCRIPTION
Metra Wristband Capturer is a retaining module for Metra RFID wristbands. It is integrated in different Metra MEW products such as Tripod Turnstile and Turnstile Access Terminal.
Ticket retain feature allows re-using of various tickets. For that innovative
feature Metra has developed patented in 1998 contact-less “Wristband Capturer”
(WBC) together with contactless RFID Wristband.
RFID ISO reader reads ISO 15693, ISO 14443A, ISO 14443B and Mifare compatible
RFID media. The Metra Wristband Capturer grants the exit signal only when the
ticket is successfully erased and retained. This dramatically cuts costs of
the system operation and the chance of fraud. A ticket will be retained under
following conditions:
· Retain request written on it/assigned to it. · It is presented to the
retaining device.
3 CONNECTIONS
There is a single connector dedicated to power and data (LIN) connection.
*NOTE: Pay attention not to mix MEW and CAN WBC connection.
© Metra 2021, All Rights reserved
[rev.2 – 15092021] The content of this document is subject to change without notice
Page 4
smarter locking
Control Device connection
WARNING · Mind the power and LIN polarity! Wrong polarity could result in
irreparable damage to the
device. · Respect power requirements data! Using unsuitable power supply could
result in damage
to the power supply and to the device.
Regulated DC power supply is required for proper operation. See chapter
“Technical Data” for power requirements. Connect the device with the supplied
cable and 4-pin connector to the control unit that controls the operation of
the entire device. For control device connector pin out details see next
chapter.
For connection on Control Device side consult appropriate Technical Manual
such as “Metra Turnstile Access Terminal Technical Manual” or “Metra Tripod
Turnstile – Technical Manual”.
Control Device connector pin out details
4 OPERATING INDICATOR
When the unit is running in idle mode, Metra logo on the front panel is
blinking in Metra invite rhythm.
© Metra 2021, All Rights reserved
[rev.2 – 15092021] The content of this document is subject to change without notice
Page 5
smarter locking
5 SIGNALIZATION
While reading RFID wristband BLUE LED signals normal operation accompanied with short beep and appropriate direction light signal. In case approached RFID wristband is denied or error occurs during reading, LED blinks fast in RED for 2 seconds and RED cross appears on semaphore. It’s accompanied with 2 second beeping acoustic signal.
6 DIP SWITCH SETTINGS
For normal operation all 4 DIP switches must be set to `0′ or OFF position.
Any other setting is reserved for special operating / test / debug mode.
To change between different operating modes, use a small flat screwdriver or
similar object to push DIP switch pins to desired position.
NOTE Switches #1 through #4 must be set to OFF position (switch down) for
normal operation mode.
Special modes of operation
Look up the table for desired application in the coding table below. Set switches #1 to #4 to indicated positions. Use only one application at a time. · 0 indicates the corresponding switch is in OFF position (switch down) · 1 indicates the corresponding switch is in ON position (switch up)
switch # DIP SW1 DIP SW2 DIP SW3 DIP SW4
application TEST MODE enabled. Operation is adapted to silicone wristbands. Debug message is enabled. Automatic capturing of RFID media presented on cover reader.
NOTE The device should always operate in NORMAL mode.
© Metra 2021, All Rights reserved
[rev.2 – 15092021] The content of this document is subject to change without notice
Page 6
smarter locking
TEST mode of operation (SW1)
Set DIP switch 1 to position 1′ all other switches are set to
0′. TEST mode
is reserved for service personnel and can be used only with special test
software.
Silicone wristbands operation (SW2)
Set DIP switch 2 to position 1′ all other switches are set to
0′. In this
mode, the front door will remain open for a moment longer so that the user has
extra time to insert the softer wristband.
Debug message (SW3)
Set DIP switch 3 to position 1′ all other switches are set to
0′. This mode
is reserved for service personnel and can be used only with special test
software.
Automatic capturing (SW4)
Set DIP switch 4 to position 1′ all other switches are set to
0′. This
feature is not yet implemented and is meant only for debug
7 MOUNTING INSTRUCTIONS
Mounting slides positions on the Wristband Capturer
Mounting guides positions on the mounting surface
STEP 1: Position the capturer Put the Wristband Capturer onto the provided mounting surface so that the mounting slides of the Wristband Capturer mate with the mounting guides of the mounting surface.
© Metra 2021, All Rights reserved
[rev.2 – 15092021] The content of this document is subject to change without notice
Page 7
smarter locking
STEP 2: Secure the position Push the Wristband Capturer housing towards the
mounting surface (red arrow), then push the metal carrier plate against the
cover back wall (green arrow) to secure the position and then tighten the nut
(blue arrow).
STEP 3: Connect the Power/LIN Check that no cables are in the way of the
wristband collecting pan or the flip antenna.
© Metra 2021, All Rights reserved
[rev.2 – 15092021] The content of this document is subject to change without notice
Page 8
8 TECHNICAL DATA
smarter locking
Operating voltage Operating temperature range Operating relative humidity
range
Audio signal Visual signalization
Network type Dimensions in mm (w/h/l)
24V DC regulated -10 °C to +50 °C 20% to 80% (non-condensing) Integrated piezoelectric beeper Metra logo on front panel MEW (LIN) 147 / 75 / 230
© Metra 2021, All Rights reserved
[rev.2 – 15092021] The content of this document is subject to change without notice
Page 9
References
- Metra - The Smart Locker System for hybrid offices, smart buildings, campuses and leisure facilities
- Metra - The Smart Locker System for hybrid offices, smart buildings, campuses and leisure facilities