SJE RHOMBUS 1011423 TA AB-01X Liquid Level Alarm System Owner’s Manual
- September 2, 2024
- SJE RHOMBUS
Table of Contents
SJE RHOMBUS 1011423 TA AB-01X Liquid Level Alarm System
Product Specifications
- Voltage: Primary: 120 VAC, 60 Hz, 2.4 watts max. (alarm condition) Secondary: 9 VDC
- Battery Backup Power: 9 VDC
- Alarm Enclosure: 15.24 x 10.16 x 5.71 cm (6 x 4 x 2.25 inch), NEMA 1 plastic
- Alarm Horn: 87 decibels at 3 meters (10 feet)
- Auxiliary Alarm Contacts (optional): (CSA certified only unit) Voltage: 120 VAC Current: 5 amps maximum N/O 3amps maximum N/C
- Power Cord: 1.8 meter (6 foot)
Product Usage Instructions
Installation
- Choose a suitable location for the alarm system indoors.
- Connect the power cord to a primary 120 VAC outlet.
- Ensure the battery backup power is connected to maintain functionality during power outages.
- If using Auxiliary Alarm Contacts, follow the provided instructions for installation.
Operation
- Ensure the alarm system is powered on.
- The system will trigger an alarm in case of liquid level reaching the set thresholds.
- If an alarm is activated, investigate and address the liquid level issue promptly.
- The system features auto-reset for convenience after an alarm event.
Maintenance
- Regularly check the functionality of the alarm system by triggering test alarms.
- Inspect the battery backup power to ensure it is operational.
- Clean the alarm enclosure periodically to prevent dust accumulation.
Frequently Asked Questions (FAQ)
-
Q: How can I test if the alarm system is functioning correctly?
A: You can trigger a test alarm by manually simulating a liquid level rise. Follow the instructions in the user manual for testing procedures. -
Q: What should I do if the alarm keeps sounding without a real issue?
A: Check the sensor and liquid level settings to ensure they are correctly configured. If the issue persists, contact customer service for assistance.
TANK ALERT® AB ALARM SYSTEM
Easy-to-install liquid level alarm system with auto-reset and battery backup
features for indoor use.
This alarm system monitors liquid levels in lift pump chambers, sump pump
basins, holding tanks, sewage, agricultural, and other water applications. The
Tank Alert® AB alarm system can serve as a high or low level alarm depending
on the float switch model used. The alarm horn sounds when a potentially
threatening liquid level condition occurs. The horn can be silenced, but the
alarm light remains on until the condition is remedied. Once the condition is
cleared, the alarm will automatically reset. A green “Power On” light
indicates 120 VAC primary power to the alarm. Low battery chirp feature
indicates when battery should be replaced.
FEATURES
- NEMA 1 enclosure, designed for ease of installation, rated for indoor use
- Automatic alarm reset
- Red “alarm” light and green “power on” light, alarm “test” switch, and horn “silence” switch
- Alarm horn sounds at 87 decibels at 3 meters (10 feet)
- Can be used with any UL Listed / Recognized switching mechanism rated to include 1 amp, 9 VDC load
- If primary power fails, the alarm system continues to work due to battery backup feature (battery not included)
- Complete package includes standard SJE SignalMaster® control switch with 4.57 meters (15 feet) of cable (other lengths available) and mounting clamp
- Switching mechanism operates on low voltage and is isolated from the power line to reduce the possibility of shock
- Low battery chirp
- Easy access battery compartment
- External terminal block for easy float switch installation
Alarm Systems
OPTIONS
When ordered with the alarm, this system is available with:
- Alternate float switch models for high or low level warning
- Auxiliary dry normally open and normally closed contacts (Tank Alert® AB auxiliary contacts included is CSA certified only.)
- Splice kit
SPECIFICATIONS
- Voltage: Primary: 120 VAC, 60 Hz, 2.4 watts max. (alarm condition)
- Secondary: 9 VDC
- Battery Backup Power: 9 VDC
- Alarm Enclosure: 15.24 x 10.16 x 5.71 cm (6 x 4 x 2.25 inch), NEMA 1 plastic
- Alarm Horn: 87 decibels at 3 meters (10 feet)
- Auxiliary Alarm Contacts (optional): (CSA certified only unit)
- Voltage: V120 AC
- Current: 5 amps maximum N/O
- 3 amps maximum N/C
- Power Cord: 1.8 meter (6 foot)
- Float Switch Connection Terminal: For float switch connection only. Do not apply power. (Voltage across terminals is 8-9 VDC).
- Float Switch: SJE SignalMaster® control switch with mounting clamp
- Cable: 4.57 meters (15 feet), flexible 18 gauge, 2 conductor (UL) SJOW, water-resistant (CPE)
- Float: 7.0 cm diameter x 12.3 cm long (2.74 inch x 4.83 inch), high impact, corrosion resistant polypropylene housing for use in sewage and water up to 60°C (140°F)
ORDERING INFORMATION
STANDARD ALARM (120 VAC) | Shipping Weight |
---|---|
Part # | Description |
1011421 | TA AB-01H (120 VAC w/15′ SJE SignalMaster® High Level) |
1011424 | TA AB-01L (120 VAC w/15′ SJE SignalMaster® Low Level) |
1011423 | TA AB-01X (120 VAC no float) |
- H = High Level L = Low Level X = No Float
- MASTER CARTON holds 16 boxed units.
- SEE INTERNATIONAL PRICE BOOK FOR LIST PRICING.
Option | Description |
---|---|
AUX | Auxiliary Alarm Contacts (CSA certified only unit, factory |
installed)
OPTIONS
Control Switch Options
The Tank Alert® AB alarm system comes standard with a 4.57 meter (15 ft.) SJE
SignalMaster® control switch with mounting clamp. Other float switches are
available. See the control switch section of this catalog.