BROOKFIELD AMETEK DAA Series DIN Adapter Instruction Manual

August 30, 2024
BROOKFIELD AMETEK

DAA Series DIN Adapter

Specifications:

  • Standard Version (Part Number DAA) includes DIN spindles 85,
    86, and 87, sample chambers ULA-DIN-6Y and DAA-1, locating channel
    ULA-DIN-7Y, clamp assembly DAA-2Y, water jacket ULA-40Y, and 6 tube
    end caps ULA-34.

  • Magnetic Version (Part Number DAAM) includes the same parts
    except for DIN spindles 85M, 86M, and 87M.

Product Usage Instructions:

Assembly:

  1. Attach the locating channel to the Viscometer/Rheometer Pivot
    cup by screwing the upper mounting screw into the hole at the rear
    of the Pivot cup.

  2. Attach the clamp assembly to the locating channel by screwing
    the lower mounting screw on the locating channel into the hole at
    the back of the clamp assembly.

  3. To control sample temperature, insert the sample chamber into
    the water jacket.

Operation:

  1. Pour the sample into the Sample Chamber.
  2. Insert the Spindle into the Sample Chamber.
  3. Install the Sample Chamber onto the clamp assembly. Slide it up
    into the clamp and tighten the Hand-wheel.

FAQ:

Q: How can I control the sample temperature?

A: You can control the sample temperature by inserting the
sample chamber into the water jacket. If the water jacket does not
slide easily onto the Sample Chamber, lubricate the O-rings with
silicone oil.

Q: What should I do if my viscometer has an older pivot

cup?

A: If your viscometer has a Type I or Type II pivot cup, it
should be replaced with a Type III cup. Contact AMETEK Brookfield
or your local authorized dealer for more information.

800-628-8139 or 508-946-6200 brookfieldengineering.com

DIN Adapter Instructions
Accessories Operation Instructions
These instructions apply to both the Standard Coupling Nut and Magnetic Coupling for Spindle Connection.

The DIN Adapter Accessory components are as follows: the Standard Version, part number DAA, includes: DIN spindles 85, 86 and 87, sample chambers ULA- DIN-6Y and DAA-1, locating channel ULA-DIN-7Y, clamp assembly DAA-2Y, water jacket ULA-40Y and 6 tube end caps ULA-34. The Magnetic Version, part number DAAM (part number DAAMC for the Magnetic Compliant version), includes the same parts with the exception of DIN spindles 85M, 86M and 87M. All of these components are shown in Figure 1.

ULA-DIN-87 SPINDLE
ULA-DIN-86 SPINDLE
ULA-DIN-6Y INSERT
ASSEMBLY

VISCOMETER PIVOT CUP
ULA-DIN-85 SPINDLE
ULA-DIN-7Y LOCATING CHANNEL ASSEMBLY
DAA-2Y CLAMP ASSEMBLY
DAA-1 SAMPLE CHAMBER

Magnetic Version

ULA-DIN-87M SPINDLE

ULA-DIN-85M SPINDLE

ULA-DIN-86M SPINDLE

ULA-44 O-RING
ULA-40SY WATER JACKET SUB-ASSEMBLY ULA-44 O-RING
ULA-34 TUBE END CAP (Set of 6) (used with DAA-1 SAMPLE CHAMBER)
Figure 1 : DIN Adapter Components

DAA-6 CARRYING CASE

M95-083-2.0

©2024 AMETEK Brookfield. All rights reserved

When an older dial reading viscometer is used, the viscometer pivot cup may need to be replaced with the current design as shown in Figure 2. If your viscometer has a Type I or Type II pivot cup, the cup should be replaced with a Type III cup. Contact AMETEK Brookfield or your local authorized dealer for information.
Figure 2: Pivot Cup Compatibility

TYPE I
TYPE II
TYPE III THREADED HOLE

Assembly
With the Viscometer/Rheometer set up on the lab stand and leveled, the DIN Adapter Accessory is assembled as follows:
1. Attach the locating channel to the Viscometer/Rheometer Pivot cup, shown in Figure 3, by screwing the upper mounting screw into the hole at the rear of the Pivot cup. Note: The pin is at the bottom of the locating channel.

Locating Channel
Upper Mounting Screw

Pivot Cup

Locating Pin
Lower Mounting Screw
Figure 3: Installing the Locating Channel

Locating Channel

Locating Pin
“Notch” for Locating Pin

Lower Mounting Screw

Clamp Assembly
Figure 4: Installing the Clamp Assembly

2. Attach the clamp assembly to the locating channel, as shown in Figure 4, by screwing the lower mounting screw on the locating channel into the hole at the back of the clamp assembly. Note: The pin is at the bottom of the locating channel.
3. Temperature of the sample may be controlled through the use of a water jacket. To control temperature, insert either sample chamber into the water jacket as shown in Figure 5. If the water jacket does not slide onto the Sample Chamber easily, the “O” rings may need to be lubricated with silicone oil. Note: If sample chamber DAA-1 is used, the end cap is also installed.

M95-083-2.0

©2024 AMETEK Brookfield. All rights reserved

Figure 5: Installing the Water Jacket

Figure 6: Installing the Water Bath

4. The water jacket is connected to a circulating water bath as shown in Figure 6. For temperatures from -15°C to 65°C, gum rubber tubing (Brookfield Part No. EX-TUBING) is used. For temperatures from 65°C to 100°C, Fluran® tubing (Brookfield Part No. ULA-45) should be used.

Operation
1. Pour the sample into the Sample Chamber. 2. Insert the Spindle into the Sample Chamber. 3. Install the Sample Chamber onto the clamp assembly, see Figure 7. Slide the Sample Chamber/Water Jacket
up into the clamp and tighten the Hand-wheel. Figure 7: Installing the Sample Chamber/Water Jacket

HANDWHEEL
SPINDLE
SAMPLE CHAMBER WATER JACKET

Handwheel
Coupling Nut (Attached to Spindle)
Sample Chamber
Water Jacket

Standard Coupling Nut

Magnetic Coupling

4. Install the Spindle onto the viscometer/rheometer pointer shaft, see Figure 8. For the Standard Coupling Nut, lift the coupling when attaching the spindle to avoid damage to the instrument. (Note: spindles have a left-handed thread for installation.) For the Magnetic Coupling, attach the spindle coupling to the viscometer by carefully inserting the spindle coupling into the instrument coupling. When properly installed, there should be no gap between the spindle coupling and the instrument coupling.

M95-083-2.0

©2024 AMETEK Brookfield. All rights reserved

Figure 8: Installing the Spindle
POINTER SHAFT COUPLING NUT
(attached to spindle)

Instrument Coupling
Spindle Coupling (attached to spindle)

Standard Coupling Nut

Magnetic Coupling

5. If the viscometer is a digital model, enter the proper spindle entry code (85, 86 or 87) following the procedure in the viscometer/rheometer operating manual. If a model Dial Reading is used, the spindle factors are found on page 4 of this manual.
6. The viscometer/rheometer speed may now be set and readings can be taken as described in the viscometer/rheometer operating manual.

M95-083-2.0

©2024 AMETEK Brookfield. All rights reserved

Spindle Factors, DV-Series Viscometers

Speed, RPM

Spindle 85

0.3

38.12

0.6

19.06

1.5

7.62

3

3.81

6

1.91

12

0.95

30

0.38

60

0.19

Spindle 86
N/A N/A 22.81 11.40 5.70 2.85 1.14 0.57

Spindle 87
378.00 189.00 75.60 37.80 18.90
9.45 3.78 1.89

Shear Rate, Sec-1
0.39 0.77 1.94 3.87 7.74 15.48 38.70 77.40

Spindle Factors, Spindle 85 with RV, HA, HB Dial Reading and DV-Series Viscometers

Speed,

Shear

RPM

RV

HA

HB Rate,

Sec-1

0.5

N/A

N/A

N/A

0.65

1.0

N/A

N/A

N/A

1.29

2.0

N/A

N/A

N/A

2.58

2.5

48.80

N/A

N/A

3.23

4

30.50

N/A

N/A

5.16

5

24.40

48.80

N/A

6.45

10

12.20

24.40

N/A

12.90

20

6.10

12.20

48.80

25.80

50

2.44

4.88

19.52

64.50

100

1.22

2.44

9.76

129.00

Spindle Factors, Spindle 86 with RV, HA, HB Dial Reading and DV-Series Viscometers

Speed,

RPM

RV

0.5

N/A

1.0

N/A

2.0

N/A

2.5

N/A

4

91.25

5

73.00

10

36.50

20

18.25

50

7.30

100

3.65

HA
N/A N/A N/A N/A N/A N/A 73.00 36.50 14.60 7.30

HB
N/A N/A N/A N/A N/A N/A N/A N/A 58.40 29.20

Shear Rate, Sec-1
0.65 1.29 2.58 3.23 5.16 6.45 12.90 25.80 64.50 129.00

Spindle Factors, Spindle 87 with RV, HA, HB Dial Reading and DV-Series Viscometers

Speed,

Shear

RPM

RV

HA

HB Rate,

Sec-1

0.5

N/A

N/A

N/A

0.65

1.0

N/A

N/A

N/A

1.29

2.0

N/A

N/A

N/A

2.58

2.5

485.20

N/A

N/A

3.23

4

303.25

N/A

N/A

5.16

5

242.6

485.20

N/A

6.45

10

121.3

242.60

N/A

12.90

20

60.65

121.30

485.20

25.80

50

24.26

48.52

194.08

64.50

100

12.13

24.26

97.04

129.00

Table 1: Viscometer Factors

M95-083-2.0

©2024 AMETEK Brookfield. All rights reserved

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals