ACiQ-06W-HH-MC Platinum Single Zone Air Handler Remote Controller Owner’s Manual

August 27, 2024
ACiQ

ACiQ-06W-HH-MC Platinum Single Zone Air Handler Remote Controller

“`html

Specifications:

  • Models Covered: ACiQ-06W-HH-MC, ACiQ-09W-HH-MC, ACiQ-12W-HH-MC,
    ACiQ-18W-HH-MC, ACiQ-24W-HH-MC, ACiQ-30W-HH-MC, ACiQ-36W-HH-MC

  • Version Date: 08-11-24

Product Usage Instructions:

Handling the Remote Controller

Inserting and Replacing Batteries:

  1. Slide the back cover from the remote control downward to expose
    the battery compartment.

  2. Insert the batteries, ensuring the correct alignment of the (+)
    and (-) ends with the symbols inside the compartment.

  3. Slide the battery cover back into place.

Battery Notes:

Dispose of batteries according to local laws if not planning to
use the device for more than 2 months.

Notes for Using Remote Control:

Comply with FCC rules. The device must not cause harmful
interference and should accept any interference.

Buttons and Functions

ON/OFF: Turns the unit on or off.

SET: Scrolls through operation functions such
as Breeze away, Active clean, Fresh/UV-C lamp, Sleep, Follow Me, AP
mode. Press OK to confirm selection.

TEMP: Decreases temperature in increments.
Minimum temperature is 16°C (60°F).

FAN SPEED: Select fan speeds in the order AU,
20%, 40%, 60%, 80%, 100%. Use TEMP buttons to adjust fan speed.

SWING: Starts and stops horizontal louver
movement. Hold for 2 seconds to activate vertical louver auto
swing.

FAQ:

Q: How do I dispose of the batteries properly?

A: Refer to local laws for proper disposal of
batteries if not using the device for more than 2 months.

Q: What should I do if the remote control is not

functioning?

A: Ensure batteries are inserted correctly and
have sufficient power. If issues persist, contact customer support
for assistance.

“`

PLATINUM SINGLE-ZONE & MULTI-ZONE WALL-MOUNTED AIR HANDLER
REMOTE CONTROLLER OWNER’S MANUAL
Models Covered: ACiQ-06W-HH-MC ACiQ-09W-HH-MC ACiQ-12W-HH-MC ACiQ-18W-HH-MC ACiQ-24W-HH-MC ACiQ-30W-HH-MC ACiQ-36W-HH-MC

IMPORTANT NOTE:

Thank you for purchasing our air conditioner. Please read this manual

carefully before operating your new air conditioning unit. Make sure to save

this manual for future reference.

VERSION DATE: 08-11-24

Table of Contents
Remote Controller Specifications ………………………………………………02 Handling the Remote Controller …………………………………………….03 Buttons and Functions ………………………………………………………….04 Remote Screen Indicators ……………………………………………………..06 How to Use Basic Functions ………………………………………………….07 How to Use Advanced Functions …………………………………………..10
01

Remote Controller Specifications
RG10L(G2HS)/BGEF, RG10L(G2HS)/BGEFU1, RG10L1(G2HS)/BGEF, RG10L1(G2HS)/BGEFU1, RG10L10(G2HS)/BGEF,RG10P(G2HS)/BGEF, RG10P(G2HS)/BGEFU1, RG10P1(G2HS)/BGEF, RG10L(D2HS)/BGEF, RG10L(D2HS)/BGEFU1, RG10L1(D2HS)/BGEF, RG10L1(D2HS)/BGEFU1, RG10P1(G2HS)/BGEFU1RG10L10(D2HS)/BGEF
3.0V( Dry batteries R03/LR03×2) 8m -5°C~60°C(23°F~140°F)
Quick Start Guide

1
FIT BATTERIES

2
AUTO COOL DRY HEAT FAN
SELECT MODE

3
SELECT TEMPERATURE

6

5

4

AU-100%

PRESS POWER BUTTON

POINT

Mode

HEDARCTYOAOULTO

SET TEMPERATURE LOMWEHDIGFAHN

On/Off Fan

Timer Swing

My Mode Follow Me

Sleep

Ioniser

LED Self Clean

Turbo

REMOTE

TOWARD

UNIT

SELECT FAN SPEED

NOT SURE WHAT A FUNCTION DOES? Refer to the How to Use Basic Functions and How to Use Advanced Functions sections of this manual for a detailed description of how to use your air conditioner.

SPECIAL NOTE
· Button designs on your unit may differ slightly from the example shown. · If the indoor unit does not have a particular function, pressing that function’s button on
the remote control will have no effect. · When there are wide differences between “Remote controller Manual” and “USER’S
MANUAL” on function description, the description of “USER’S MANUAL” shall prevail.
02

Handling the Remote Controller

Inserting and Replacing Batteries
Your air conditioning unit may come with two batteries(some units). Put the batteries in the remote control before use. 1. Slide the back cover from the remote control
downward, exposing the battery compartment. 2. Insert the batteries, paying attention to match
up the (+) and (-) ends of the batteries with the symbols inside the battery compartment. 3. Slide the battery cover back into place.
BATTERY NOTES
For optimum product performance: · Do not mix old and new batteries, or
batteries of different types. · Do not leave batteries in the remote control
if you don’t plan on using the device for more than 2 months.
BATTERY DISPOSAL
Do not dispose of batteries as unsorted municipal waste. Refer to local laws for proper disposal of batteries.
TIPS FOR USING REMOTE CONTROL · The remote control must be used within 8
meters of the unit. · The unit will beep when remote signal is
received. · Curtains, other materials and direct sunlight
can interfere with the infrared signal receiver. · Remove batteries if the remote will not be
used more than 2 months.

NOTES FOR USING REMOTE CONTROL
The device could comply with the local national regulations. · In Canada, it should comply with
CAN ICES-3(B)/NMB-3(B). · In USA, this device complies with part 15 of the
FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference,
and (2) this device must accept any interference
received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. Changes or modifications not approved by the party responsible for compliance could void user’s authority to operate the equipment.

03

Buttons and Functions

Before you begin using your new air conditioner, make sure to familiarize yourself with its remote control. The following is a brief introduction to the remote control itself. For instructions on how to operate your air conditioner, refer to the How to Use Basic Functions section of this manual.

ON/OFF Turns the unit on or off.
TEMP Increases temperature in 0.5°C (1°F) increments. Max. temperature is 30°C (86°F). NOTE: Press together &
buttons at the same time for 3 seconds will alternate the temperature display between the °C & °F.
SET Scrolls through operation functions as follows: Breeze away( )Active clean( )Fresh/UV-C lamp( ) Sleep( ) Follow Me( ) AP mode ( )Breeze away…
The selected symbol will flash on the display area, press the OK button to confirm.
TEMP Decreases temperature in 0.5OC(1OF) increments. Min. temperature is 16OC(60OF).
FAN SPEED Selects fan speeds in the following order: AU 20% 40% 60%80% 100%.
Press the TEMP or button to increase/decrease the fan speed in 1% increments.
SWING Starts and stops the horizontal louver movement. Hold down for 2 seconds to initiate vertical louver auto swing feature.

MODE Scrolls through operation modes as follows: AUTO COOL DRY HEAT FAN
NOTE: HEAT mode is not supported by the cooling only appliance.
Eco Intelligent eye Used to detect the people activities in the room to save energy.
OK Used to confirm the selected functions.
TIMER
Set timer to turn unit on or off
ECO/GEAR Press this button to enter the energy efficient mode in a sequence of following:
ECO GEAR(75%) GEAR(50%) Previous setting mode ECO……
HUMIDITY Adjust the room humidity during Dry operation in a range of 35%~85%. Press this button to increase the humidity in 5% increments. NOTE: After setting, the humidity settings will display on the screen.
LED urns indoor unit’s LED display and air conditioner buzzer on and off, which create a comfortable and quiet environment.
TURBO Enables unit to reach preset temperature in shortest possible time.

Model: RG10L(G2HS)/BGEF and RG10L(G2HS)/BGEFU1(Fresh feature is not available)
RG10L1(G2HS)/BGEF,RG10L1(G2HS)/BGEFU1 RG10L10(G2HS)/BGEF(20-28OC/68-82OF)

04

ON/OFF Turns the unit on or off.
TEMP Increases temperature in 0.5°C (1°F) increments. Max. temperature is 30°C (86°F). NOTE: Press together &
buttons at the same time for 3 seconds will alternate the temperature display between the °C & °F.
SET Scrolls through operation functions as follows: Self clean( )Fresh/UVC lamp( ) Sleep( ) Follow Me( ) AP mode ( )Self clean…
The selected symbol will flash on the display area, press the OK button to confirm.
TEMP Decreases temperature in 0.5OC(1OF) increments. Min. temperature is 16OC(60OF).
FAN SPEED Selects fan speeds in the following order: AU 20% 40% 60%80% 100%.
Press the TEMP or button to increase/decrease the fan speed in 1% increments.
SWING Starts and stops the horizontal louver movement. Hold down for 2 seconds to initiate vertical louver auto swing feature.

MODE Scrolls through operation modes as follows: AUTO COOL DRY HEAT FAN NOTE: HEAT mode is not supported by the cooling only appliance.
Intelligent eye function Used to select wind flow follow people feature or wind flow away from people feature.
OK Used to confirm the selected functions.
TIMER
Set timer to turn unit on or off ECO/GEAR Press this button to enter the energy efficient mode in a sequence of following:
ECO GEAR(75%) GEAR(50%) Previous setting mode ECO……
HUMIDITY Adjust the room humidity during Dry operation in a range of 35%~85%. Press this button to increase the humidity in 5% increments. NOTE: After setting, the humidity settings will display on the screen.
LED
Turns indoor unit’s LED display and air conditioner buzzer on and off, which create a comfortable and quiet environment.
TURBO Enables unit to reach preset temperature in shortest possible time.

Model: RG10P(G2HS)/BGEF and RG10P(G2HS)/BGEFU1(Fresh feature is not available) RG10P1(G2HS)/BGEF,RG10P1(G2HS)/BGEFU1

05

ON/OFF Turns the unit on or off.
TEMP Increases temperature in 0.5°C (1°F) increments. Max. temperature is 30°C (86°F). NOTE: Press together &
buttons at the same time for 3 seconds will alternate the temperature display between the °C & °F.
SET Scrolls through operation functions as follows: Breeze away( )Active clean( )Fresh/UV-C lamp( ) Sleep( ) Follow Me( ) AP mode ( )Breeze away…
The selected symbol will flash on the display area, press the OK button to confirm.
TEMP Decreases temperature in 0.5OC(1OF) increments. Min. temperature is 16OC(60OF).
FAN SPEED Selects fan speeds in the following order: AU 20% 40% 60%80% 100%.
Press the TEMP or button to increase/decrease the fan speed in 1% increments.
SWING Starts and stops the horizontal louver movement. Hold down for 2 seconds to initiate vertical louver auto swing feature.

MODE Scrolls through operation modes as follows: AUTO COOL DRY HEAT FAN NOTE: HEAT mode is not supported by the cooling only appliance.
Eco Intelligent eye Used to detect the people activities in the room to save energy. OK Used to confirm the selected functions. TIMER Set timer to turn unit on or off
ECO/GEAR Press this button to enter the energy efficient mode in a sequence of following:
ECO GEAR(75%) GEAR(50%) Previous setting mode ECO……
HUMIDITY Adjust the room humidity during Dry operation in a range of 35%~85%. Press this button to increase the humidity in 5% increments. NOTE: After setting, the humidity settings will display on the screen.
LED
Turns indoor unit’s LED display and air conditioner buzzer on and off, which create a comfortable and quiet environment.
TURBO Enables unit to reach preset temperature in shortest possible time.

Model: RG10L(D2HS)/BGEF and RG10L(D2HS)/BGEFU1(Fresh feature is not available) RG10L1(D2HS)/BGEF,RG10L1(D2HS)/BGEFU1
RG10L10(D2HS)/BGEF(20-28OC/68-82OF)

06

Remote Screen Indicators

Information are displayed when the remote controller is power up.

Wind flow follow people (some units) Breeze Away display
Not applicable for this unit Not applicable for this unit
ECO intelligent eye display (some units)

Active clean feature display Fresh/UV-C lamp feature display Sleep mode display
Follow me feature display
Wireless control feature display (some units) Low battery detection display(If flashes)

Transmission Indicator
Lights up when remote sends signal to indoor unit

MODE display Displays the current mode, including:

TIMER ON display

ECO display Displays when ECO feature is activated

TIMER OFF display
Silence feature display

FAN SPEED display

Displays selected fan speed:

Silence
LOW MED

1% 2%-20% 21%-40% 41%-60%
61%-80%

HIGH

81%-100%

AUTO

Horizontal louver swing display(some units)

GEAR display Displays when GEAR feature is activated
LOCK display Displays when LOCK feature is activated.
Temperature/Timer/Fan speed
display Displays the set temperature by default, or fan speed or timer setting when using TIMER ON/OFF functions.
Temperature range: 16-30oC/60-86 oF (20-28oC/68-82oF) (Model dependent)

This fan speed can not be adjusted in AUTO or DRY mode.

Vertical louver auto swing display
TURBO mode display

Timer setting range: 0-24 hours
Fan speed setting range: AU -100%

Not applicalbe for

Humidity setting range:

this unit

35% -85%

This display is blank when

operating in FAN mode.

Note:

All indicators shown in the figure are for the purpose of clear presentation. But during the actual

operation, only the relative function signs are shown on the display window.

07

How to Use Basic Functions

ATTENTION Before operation, please ensure the unit is plugged in and power is available.

AUTO Mode Select AUTO mode

Set your desired temperature

Turn on the air conditioner

MODE

NOTE:
1. In AUTO mode, the unit will automatically select the COOL, FAN, or HEAT function based on the set temperature.
2. In AUTO mode, fan speed can not be set.

COOL or HEAT Mode Select COOL/HEAT mode

Set the temperature

Set the fan speed

Turn on the air conditioner

MODE

DRY Mode Select DRY mode
MODE

Set your desired temperature

Turn on the air conditioner

NOTE: In DRY mode, fan speed can not be set since it has already been automatically controlled.

FAN Mode

Select FAN mode

Set the fan speed

Turn on the air conditioner

MODE

NOTE: In FAN mode, you can’t set the temperature. As a result , no temperature displays in remote screen.
08

Setting the TIMER
TIMER ON/OFF – Set the amount of time after which the unit will automatically turn on/off.

TIMER ON setting
Press TIMER button to initiate the ON time sequence.

Press Temp. up or down button for for multiple times to set the desired time to turn on the unit.
x5

Point remote to unit and wait 1sec, the TIMER ON will be activated.
1sec

TIMER OFF setting
Press TIMER button to initiate the OFF time sequence.

ON/OFF

MODE FAN
SLEEP

TEMP

SCHUOTRT TIMER ON

TIMER OFF

Press Temp. up or down button for for multiple times to set the desired time to turn off the unit.
x10

Point remote to unit and wait 1sec, the TIMER OFF will be activated.
1sec

ON/OFF

MODE FAN
SLEEP

TEMP

SCHUOTRT TIMER ON

TIMER OFF

NOTE: 1. When setting the TIMER ON or TIMER OFF, the time will increase by 30 minutes increments with each
press, up to 10 hours. After 10 hours and up to 24, it will increase in 1 hour increments. (For example, press 5 times to get 2.5h, and press 10 times to get 5h,) The timer will revert to 0.0 after 24. 2. Cancel either function by setting its timer to 0.0h.

TIMER ON & OFF setting(example) Keep in mind that the time periods you set for both functions refer to hours after the current time.

xn

xn

ON/OFF

MODE FAN
SLEEP

TEMP

SCHUOTRT TIMER ON

TIMER OFF

ON/OFF

MODE FAN
SLEEP

TEMP

SCHUOTRT TIMER ON

TIMER OFF

Timer starts

Unit turns
ON

Unit turns
OFF

Current time 1PM

2:00PM 3:00PM

3:30PM

4PM

5PM

6PM

2.5 hours later 5 hours later

Example: If current timer is 1:00PM, to set the timer as above steps, the unit will turn on 2.5h later (3:30PM) and turn off at 6:00PM.

09

How to Use Advanced Functions
Swing function Press Swing button
Swing

2s
Swing

The horizontal louver will swing up and down automatically when pressing Swing button. Press again to make it stop.
Airflow direction
Swing

LED DISPLAY

LED

Press LED button

Keep pressing this button more than 2 seconds, the vertical louver swing function is activated. (Model dependent)
If continue to press the SWING button, five different airflow directions can be set. The louver can be move at a certain range each time you press the button. Press the button until the direction you prefer is reached(some units only).

5s

LED

Press this button more than 5 seconds(some units)

Press this button to turn on and turn off the display on the indoor unit.

Keep pressing this button more than 5 seconds, the indoor unit will display the actual room temperature. Press more than 5 seconds again will revert back to display the setting temperature.

Turbo Function

Press Turbo button
Turbo

When you select Turbo feature in COOL mode, the unit will blow cool air with strongest wind setting to jump-start the cooling process.
When you select Turbo feature in HEAT mode, the unit will blow heat air with strongest wind setting to jump-start the heating process(some units). For units with Electric heat elements, the Electric HEATER will activate and jump- start the heating process.

10

ECO/GEAR function
Press this button to enter the energy efficient mode in a sequence of following: ECO GEAR(75%) GEAR(50%) Previous setting mode ECO…… Note:This function is only available under COOL mode
ECO operation:
Under cooling mode, press this button, the remote controller will adjust the temperature automatically to 24OC/75 OF, fan speed of Auto to save energy (only when the set temperature is less than 24O C/75OF). If the set temperature is above 24OC/75 OF, press the ECO button, the fan speed will change to Auto, the set temperature will remain unchanged. NOTE: Pressing the ECO button, or modifying the mode or adjusting the set temperature to less than 24 OC/75OF will stop ECO operation. Under ECO operation, the set tmeperature should be 24OC/75 OF or above, it may result in insufficient cooling. If you feel uncomfortable, just press the ECO button again to stop it.
GEAR operation: Press the ECO/GEAR button to enter the GEAR operation as following: 75%(up to 75% electrial energy consumption)
50%(up to 50% electrial energy consumption)
Previous setting mode.
ECO Intelligent Eye Function(For models of RG10L series) Press this button
Under ECO Intelligent eye mode, with the built-in infrared sensor, the unit can detect the people’s activities in the room. In Cooling and heating mode ,when you are away for 30 minutes, the unit automatically lowers the frequency to save energy (for inverter models only). And the unit will automatically resume operation if sensing human activity again.
11

Silence function
2s Keep pressing Fan button for more than 2 seconds to activate/disable Silence function(some units). Due to low frequency operation of compressor, it may result in insufficient cooling and heating capacity. Press ON/OFF, Mode, Sleep, Turbo or Clean button while operating will cancel silence function.
FP function
Press this button 2 times during one second under HEAT Mode and setting temperature of 16 OC/60OF or 20O C/68O F(for models RG10L10(G2HS)/BGEF & RG10L10(D2HS)/BGEF only).
2
The unit will operate at high fan speed (while compressor on) with temperature automatically set to 8 C/46 F.

Note: This function is for heat pump air conditioner only. Press this button 2 times during one second under HEAT Mode and setting temperature of 16 C/60 F or 20 C/68 F(for model RG10L10(G2HS)/BGEF& RG10L10(D2HS)/BGEF) to
activate FP function.Press On/Off, Sleep, Mode, Fan and Temp. button while operating will
cancel this function.

LOCK function

5s
+ Turbo

5s
Humidity

Press together Turbo button and Humidity button at the same time more than 5 seconds to activate Lock function.
All buttons will not response except pressing these two
buttons for two seconds again to disable locking.

12

Intelligent Eye Function(For models of RG10P series)
Press this button
Under Intelligent eye mode, with the built-in infrared sensor, the unit can detect the people’s activities in the room. The wind can flow away from people, but also can follow people.In Cooling and heating mode ,when you are away for 30 minutes, the unit automatically lowers the frequency to save energy(for inverter models only). And the unit will automatically resume operation if sensing human activity again. For details, please see ” Intelligent Eye operation ” in “Owner’s Manual & Installation Manual” .

SET function

SET

OK

Press the SET button to enter the function setting, then press SET button or TEMP or TEMP button to select the desired function. The selected symbol will flash on the display area, press the OK button to confirm. To cancel the selected function, just perform the same procedures as above.
Press the SET button to scroll through operation functions as follows: Breeze away ( ) Active clean/Self clean ( ) Fresh/UV-C lamp( ) Sleep( ) Follow Me( ) AP mode ( ) Breeze away…. [ ]: Model dependent

Breeze Away function( ) (some units) :
This feature avoids direct air flow blowing on the body and makes you feel indulging in silky coolness.
NOTE: This feature is available under cool, Fan and Dry mode only.

Active clean function( ) (some units) :
The Active Clean Technology washes away dust, mold, and grease that may cause odors when it adheres to the heat exchanger by automatically freezing and then rapidly thawing the frost. When this function is turned on, the indoor unit display window appears “CL”, after 20 to 45 minutes, the unit will turn off automatically and cancel CLEAN function.

13

,,

Self clean function (some units) :
Airborne bacteria can grow in the moisture that condenses around heat exchanger in the unit. With regular use, most of this moisture is evaporated from the unit. Under Self clean operation, the unit unit will clean itself automatically. After cleaning, the unit will turn off automatically. Note: You can only activate this function in COOL or DRY mode.
FRESH/UV-C lamp function( ) (some units) :
When this function is selected, the Ionizer or UV-C lamp(model dependent) will be activated. If has both features, these two features will be activated at the same time. This function will help to purify the air in the room.
Sleep function( ) :
eTnheergSyLEusEePwfuhnilcetiyoonuisslueseepd(atonddedcorne,atsneeed the same temperature settings to stay comfortable). This function can only be
aFcUotriSvtEahtRee,ddSevMtiaaAilr,NesmUeeoAtLe,.,scleoenptroolp. eration,, in
NOTE: The SLEEP function is not available in FAN or DRY mode.

Follow me function( ) :
The FOLLOW ME function enables the remote control to measure the temperature at its current location and send this signal to the air conditioner every 3 minutes interval. When using AUTO, COOL or HEAT modes, measuring ambient temperature from the remote control(instead of from the indoor unit itself) will enable the air conditioner to optimize the temperature around you and ensure maximum comfort.
NOTE: Press and hold Turbo button for seven seconds to start/stop memory feature of Follow Me function.
If the memory feature is activated, ” On ” displays for 3 seconds on the screen. If the memory feature is stopped, ” OF” displays for 3 seconds on the screen. While the memory feature is activated, press the ON/OFF button, shift the mode or power failure will not cancel the Follow me function.
AP function( )(some units) :
Choose AP mode to do wireless network configuration. For some units, it doesn’t work by pressing the SET button. To enter the AP mode, continuously press the LED button seven times in 10 seconds.

14

The design and specifications are subject to change without prior notice for product improvement. Consult with the sales agency or manufacturer for details.
CR318-RG10LP(OEM+UV) 16122000A77108

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals