ABESTORM Guardian SNS65S Controls Crawlspace Dehumidifier User Manual

August 26, 2024
ABESTORM

ABESTORM Guardian SNS65S Controls Crawlspace Dehumidifier

Guardian SNS65S
Abestorm Solutions INC.
Add: 8605 SANTA MONICA BLVD#79525
WEST HOLLYWOOD,California,90069 USA
E-mail: sales@abestorm.com
Note: as we keep upgrading our product, we reserve the right to modify the product without notice in advance.

Warranty Registration

Congratulations on purchasing a new Guardian Dehumidifier. Your new dehumidifier comes with an extensive warranty plan. To register, simply fill out and return the warranty form provided in the dehumidfier box.
Be sure to note your dehumidifier serial number as you will need it for registration.

Safety Notes

  • The Guardian Series Dehumidifier must always be connected using a grounded electrical connection (as required for all electrical appliances). If non-grounded wiring is used, all I liability reverts to owner and the warranty is voided.
  • Guardian Dehumidifiers should only be maintained and repaired by a qualified technician.
  • Guardian Dehumidifiers are only intended for operation when oriented with the unit sitting on its feet and level. Operating the unit in any other orientation could allow water to flood electrical components.
  • Always unplug dehumidifier before moving.
  • If there is a chance that water flooded the dehumidifier, it should be opened and allowed to dry thoroughly before reconnecting to electrical power and restarting.
  • To ensure proper operation, neither the inlet nor discharge should be positioned against a wall The inlet requires a minimum of 6′ clearance and the discharge requires a minimum of 6′ clearance.
  • For better use of the dehumidifier, both air inlet and air outlet should be facing the open area of the space.
  • Do not insert your fingers or any object into the inlet or discharge.
  • All work on the dehumidifier should be done with the unit “off’ and unplugged.
  • Do not use water to clean the exterior of the machine. To clean unit, unplug from power, then use a damp cloth to wipe exterior.
  • Do not stand on the machine or use it as a device to hang clothes.

Identification

For future reference, write down the model, serial number, and date of purchase for your dehumidifier. This is extremely helpful if you need to seek assistance in the future. The data label on the side of your unit has the key characteristics of your specific machine.

  • Model Number: Guardian SNS65S
  • Serial Number: ____ _
  • Date of Purchase: ____ _
  • For additional questions concerning your dehumidifier, the following options are available:
  • Contact your installing contractor
  • E-mail: sales@abestorm.com

Electrical Supply

  • Power Supply: 115 V, 60 Hz AC, Single Phase
  • Outlet Requirement: 3-Prong, GFCI
  • Circuit Protector: 15 Amp

WARNING
240 Volts AC may cause serious injury from electric shock.

To reduce risk of injury

  1. Disconnect electrical power before servicing
  2. Only plug unit into grounded electrical circuit
  3. Do not use an extension cord.
  4. Do not use a plug adapter

Principle of Operation
The Guardian Series Dehumidifier utilizes its integral humidistat to monitor the conditioned space. When the relative humidity goes above the selected set point, the dehumidifier will energize. Air is drawn across an evaporator coil, which is cooler than the dew point of air. This means moisture will condense out of the air. The air is then reheated through the condenser coil and distributed back into the room.

Installation
The area to be controlled should be sealed with a vapor barrier. If unit is installed in a crawlspace, all vents should be sealed.
Do not install your dehumidifier in a corrosive environment. Some liquid vapor barriers dry via “solvent evaporation”. Always make sure that barrier is completely dry and area is throughly ventilated before installing dehumidifier.

  1. Step #1: Place dehumidifier on a level surface.
    Do not place directly on vapor barrier. For example, use blocks, or pavers to create a level surface.
    If the unit is handled in such a manner that the compressor did not remain in the upright position, you will need to place it on a level surface, then wait a minimum of 2 hours before turning “on”.

  2. Step #2: Set Up Drain Line.
    The included drain line attaches to unit via a compression type fitting on the discharge end of the unit. To attach drain line, remove the compression nut and slide it over the end of the hose to be at tached to unit. Slide compression nut side of hose over the insert on the compression fitting com pletely. Tighten compression nut.

  3. Step #3: Plug unit into 15 amp grounded circuit.

Key Functions

  1. Power Key 
    Use this button to turn the dehumidifier on and off. Press once to turn machine on. You will hear one beep and the light will illuminate green. Press the power button a second time and you will hear one beep as the machine shuts down. Note that there is a one-minute fan delay on shutdown.

  2. Arrow Buttons
    Use the up and down arrow button to set the desired humidity setpoint on the display screen.
    The setpoint can be any number between 35-90%. Creating a setpoint means that when the indoor humidity is lower than the set point, the machine will stop automatically. Conversely, when the indoor humidity is higher than the set level, the unit will operate. NOTE:The humidty levels displayed are approximate only (+/- 5%)

  3. Continuous Mode

    • To switch into continuous mode, simply use the down arrow to set the humidity below 35%. The Cont. light should illuminate green on the display board to indicate that you have successfully switched into continuous mode. The display screen will show “CO”.
    • When set to continuous, the dehumidifier will run constantly, regardless of the humidity level. To stop the machine, turn the unit off or switch back to normal humidistat operation. If you would like to switch back to normal humidistat operation, simply move the setpoint above 35%.
  4. Drain Button
    Hold this button down for at least 3 seconds to switch the drain system to use. Either pump drain system or gravity drain system.
    Water Pump Drainage Mode
    If the “Pump” light is turned ON, it indicates that the pump drain system is in use.
    The “Drain” button can be pressed once to force the water pump to remove the collected moisture from the water tray for 28 seconds. This button is not valid when the pump is draining.
    If the water pump float switch detected a high level of water in the tray, the pump will automatically run and drain the collected moisture for 28 seconds. If a high level of water is still detected, after the pump runs for 28 seconds, the screen will display an “E4” error code, and the entire machine will be turned off.
    Gravity Drainage Mode
    If the “Pump” light is turned OFF, it indicates that the gravity drain system is in use.
    The Water Tray Plug should be removed from the dehumidifier to properly use this drain system. This allows the dehumidifier to continuously drain the moisture collected.

  5. Wi-Fi Connection 
    Hold the “UP and DOWN” key combination to activate the Wi-Fi Connection function. For details, please refer to the “New Abestorm-C App Wi-Fi Connection Guide”.

Indicator Lights

  1. Humidity Display Screen
    • The display screen has two functions:
    • When the unit is powered on, it shows the humidity of the space.
    • While setting the desired humidity level, the screen will show the set humidity. After a brief delay, the display will revert to current humidity level.
  2. Power Indicator Light
    • This light indicates that the unit is properly powered on and ready to operate. Always make sure the unit is “off’ prior to performing any service.
    • When the power light is blinking, it means that the unit has reached the humidity setpoint.
  3. Continuous Mode/AutoDefrost Light
    • When this light illuminates green, it indicates that the dehumidifier is set to continuous operation mode.
    • When the light glows red, it means the unit is in auto defrost mode and clearing the evaporator coil of any ice buildup.
  4. Compressor Light
    • When the compressor light glows red, it indicates the compressor has been initiated but is currently warming up.
    • Once the compressor light switches to green, it indicates the compressor is in working status.
  5. Wi-Fi Light
    • The light remains off when the Wi-Fi is not connected, flashes when the Wi-Fi is connected, and stays illuminated when the Wi-Fi has been successfully connected and is operating normally.
  6. Pump Pattern Light
    • Water pump mode, this light is on; Gravity drain mode, this light is off. The default mode of the device is gravity drainage.

Remote Control Instructions

Guardian Dehumidifiers can be controlled using an optional remote accessory.The Guardian Remote Control connects to your Sentinel Series Dehumidifier via a 25′ CAT 5 cable. The remote control contains an integrated sensor which gives you multiple options for remotely controlling your unit, in addition to monitoring the conditions surrounding the dehumidifier.
One application for the remote control is to install the dehumidifier in one room with the conditioned air ducted into a second room that contains the remote. For example, the dehumidifier could be installed in a laundry room and ducted into a living room. The remote would then be mounted in the living room so the remote sensor can control the humidity and provide easy controls for the user.
Another useful application for the remote control is if the dehumidifier is in area that’s difficult to access on a regular basis. For instance, if your dehumidifier is installed in your crawl space, the remote could be mounted in your living space or garage. This provides you with an easy way to monitor the dehumidifier.

  1. On/Off (Power)Button
    Press the on/off button and the machine will st art running (one beep). Press the button again to t he turn the machine off.

  2. Up Button
    Use the Up and Down arrow buttons to adjust the humidity level.

  3. Mode M
    Use the Mode button to switch between dehumidification and a ducted application.

    • The symbol on the display board indicates the sensor on the remote control is being utilized
    • The symbol on the display board indicate s the sensor on the dehumidifier is being utilized.
  4. ABESTORM-Guardian-SNS65S-Controls-Crawlspace-Dehumidifier- 014. Temperature T
    Press the temperature button to display the current temperature on the screen. Press the button again to turn off the display. 5o Continuous C
    Press this button to switch the unit into continuous mode. cont. will appear on the display to indicate continuous mode.

  5. Drain Pump P
    Use this button if the unit will not be in use for an extended period of time. Pressing the drain pump button will remove water from the pump reservoir, so the unit can be safely moved or stored. THIS FUNCTION IS ONLY AVAILABLE ON THE Guardian SNS65S / Guardian SNS90 / Guardian SNS100 /Guardian SNS120 model.

NOTE: Symbols indicated above will only appear when the dehumidifier is powered on.

Operating Instructions

  1. Start the Machine
    Press the power key to turn the machine on.

  2. Adjust the Settings
    Use the up and down arrow keys to adjust your desired setpoint (typically 50-55%).

  3. Stop the Machine
    Press the power key again and the machine will stop. Note the fan will continue to operate for 1 minute after the unit has turned off. NOTE: Do not disconnect the power cord to force unit to stop. Always use the power button.

  4. Water Drainage
    During normal operation, the dehumidifier will automatically drain by the force of gravity. If you want to move or store your machine, wait at least 10 minutes to allow the machine to completely defrost, then lean unit gently towards drain to ensure that it is completely drained.

Diagram

ABESTORM-Guardian-SNS65S-Controls-Crawlspace-Dehumidifier-
\(10\)

Maintenance

WARNING
Always unplug the unit before doing any maintenance.

Cleaning the machine body
Use a soft damp cloth to clean exterior of unit. Do not use any soap or solvents.

Replacement filter and steps

  1. As shown in the figure above, tilt the filter into the filter slot.
  2. Push the filter upwards until it touches the top of the air filter slot.
  3. Push the bottom of the filter into the filter groove.
  4. Let the filter slide down freely.

Cleaning the filter

  1. Unplug the unit.
  2. Push up the filter.
  3. Clean the filter mesh by vacuuming or washing with warm water (no soap or solvents).
  4. Be sure filter is completely dry before restarting unit.

Coil Maintenance
Once per year , clean the coils with an approved coil cleaner.
Coil cleaner should be a self-insing, foaming cleaner such as WEB® Coil Cleaner.

Dehumidifier Storage
If the unit will be stored for an extended period of time, complete the following steps:

  1. Turn off the unit and allow to dry.
  2. Wrap and secure the power cord.
  3. Cover the filter mesh.
  4. Store in a clean, dry space.

Ducting Installation

Maximum length for ducting= 6′
Note: The supply duct adapter is standard on all units.ABESTORM-Guardian-
SNS65S-Controls-Crawlspace-Dehumidifier- \(13\)

Removing Supply Duct Adapter
If it is necessary to remove the adapter, place hand at bottom of adapter and use your fingers to pull out and down on base of adapter This will lift hooks out of cover  holes.

Installing Supply Duct Adapter
To install adapter, line up with holes on the side of unit and push up from base of adapter.

ABESTORM-Guardian-SNS65S-Controls-Crawlspace-Dehumidifier-
\(14\)

Troubleshooting

ABESTORM-Guardian-SNS65S-Controls-Crawlspace-Dehumidifier-
\(12\)

Pump Alarm- Trouble Code E4
If a pump alarm is shown on the display, complete the following steps:

  1. Reset the unit by disconnecting the power cord and then reconnecting it.
    NOTE: UNIT WILL NOT FUNCTION UNTIL ERROR CODE HAS BEEN CLEARED.

  2. Manually check to see if pump is operational by pressing the drain button. Check if the pump energizes and de-energizes properly. Additionally, check to see if any water purged from the system.

  3.  If you haven’t cleaned the system recently, check the discharge line for an obstruction, then clean the balance of the pump system (see “Maintenance” on page 7 for details).

  4. Replace the hoses and/or pump, if maintenance alone isn’t sufficient.

Water Pump Matainence and Application

Normal use of water pump

  1. Determine whether the forced drainage function is useful
    When the power is on, press the “Drain” button, the water pump runs normally, the pumping water is normal, there is no vibration and noise, and the water flows smoothly.

  2. ABESTORM-Guardian-SNS65S-Controls-Crawlspace-Dehumidifier- \(15\) Determine whether the automatic drainage function of the water pump water level line is useful
    Press the button, the machine will perform dehumidification work. When the water level in the water collector reaches a certain height, the floating ball rises, and the water pump automatically enters the water pumping state, without vibration and noise, and the water flows smoothly.

  3. Turn on the power and run the dehumidifier
    If there is no abnormality in the forced drainage function and the automatic drainage function, the user can rest assured to use this equipment. If the water pumping is abnormal, the machine will display an error code of “E4”, at this time, the user can simply repair the pump failure by himself.
    When the user is unable to repair, contact the manufacturer via email or phone.

Usage of gravity drainage pipe(lt can choose gravity drain or pump drain with the working environment).

For gravity drainage, the dehumidifier should be placed on a plane with a certain height. Pull out the screw tooth rubber plug at the outlet of the water collector of the dehumidifier, and plug in the water pipe. The condensate dripping from the coil will be discharged along the water pipe, which can be collected into the water storage container or discharged out of the room (Note: the water pipe should not be higher than the dehumidifier and should be discharged towards the ground). ABESTORM-Guardian-SNS65S-Controls-
Crawlspace-Dehumidifier- \(18\)

Water pump function

  1. Solve the inconvenience that gravity drainage can only place the machine at a fixed height, it can be put in various places in the house for work.
  2. The drainage pipe can be laid at will, without space restriction, up to 19.6 ft.
  3. It can be allowed to pump water automatically when it reaches a certain water level, or it can be pumped manually at any time, which is more flexible and convenient.
  4. The advantages of the water pump itself, low noise, low vibration, small size, long life, self-priming function, simple maintenance and easy replacement.
  5. Use the rubber stopper plug the drain hole when you use the pump drain

The fault judgment and maintenance method of the water pump
Problem judgment when “E4” error code appears:

  1. The drainage hose is blocked or bent and deformed by foreign matter.
  2. The drainage height exceeds the standard.
  3. Water level switch failure.
  4. Water pump failure or expiration of service life.
  5. Internal water pump hose is blocked or bent and deformed by foreign matter. ABESTORM-Guardian-SNS65S-Controls-Crawlspace-Dehumidifier- \(19\)

Pump repair method

  1. Use a Phillips screwdriver to unscrew the five screws on the water pump panel, you can see the fixed state of the water pump.
  2. Use a Phillips screwdriver to loosen the four screws of the water pump fixing bracket.
  3. Pull out the hose fixed in the water storage box, and take out the water pump for replacement.
  4. Install the new water pump to its original position according to the above steps. ABESTORM-Guardian-SNS65S-Controls-Crawlspace-Dehumidifier- \(20\)

Guardian SNS65S Spare Parts

All Sentinel Models-Parts

Part# **Description
S-100| Remote Control Package(cable+remote)
S-101| Remote Control
S-102| Remote Control Cable,25′
S-107| Fiexible Supply Duct,72″
S-108| Main Control Board
S-109| Display Board
S-110| RH/Temperature Sensor
Guardian SNS65S Parts
Part# Description
S-500| Fan Motor
S-501| Complete Fan Assembly
S-502| Fan Capacitor
S-503| Compressor
S-504| Compressor Capacitor
S-505| Coil Assembly
S-508| RH/Temperature Sensor Cable
S-509| Display Cable
S-510| CAT 5 Prot Internal Cable
S-513| Foot.adjustable
S-514| Condensate Pump Assembly
Guardian SNS65S Filters
Part# ****Description**
S-517| MERV-8 Filter

Limited Warranty

  • This limited warranty starts from the date of purchase. Abestorm Solutions Inc. warrants to the original purchaser that this Abestorm product is free from manufacturing defects in material or workmanship for the limited warranty period of:
  • Six (6) Month parts and labor. This includes the shipments charges for replacement parts or unit.
  • One (1) year parts and labor. This does not include the shipment charge to send the defective product back to be repaired or replaced.
  • Three (3) years parts and labor on Refrigeration System ONLY (Compressor, Condenser, and evaporator). Transportation cost, not included.
  • Five (5) years parts on Refrigeration System ONLY(Compressor, Condenser, and evaporator). Transportation cost, not included.
  • This limited warranty is valid only on products purchased from the manufacturer or Abestorm authorized dealer and operated, installed, and maintained according to the instructions included in this user guide or furnished with the product. Abestorm Solutions Inc will not provide in-home service during or after the warranty period. You may be responsible for the shipping charge to bring the product to the manufacturer for service.
  • To receive warranty service, the purchaser must contact Abestorm at 888-276-9833 or sales@abestorm.com  A proof of purchase or order number is required to receive warranty service. During the applicable warranty period, a product will be repaired or replaced at the sole option of Abestorm.
  • IMPORTANT NOTICE: Keep the item’s packaging in case warranty service is required.

Limited Warranty Exclusions
This limited warranty covers manufacturing defects in materials or workmanship encountered in normal household, commercial or noncommercial use of this product and shall not cover the following:

  • Damage occurs in uses for which this product was not intended for.
  • Damage caused by unauthorized modification or alteration of the product.
  • Cosmetic damage including scratches, dents, chips, and other damage to the product’s finishes.
  • Damage caused by abuse, misuse, pest infestation, accident, fire, floods, or other acts of nature.
  • Damage caused by incorrect electrical line current, voltage, fluctuations, and surges.
  • Damage caused by failure to perform proper maintenance of the product.

The use of this product in SPA or a room with OUTDOOR POOL invalidate or voids limited warranty.

ABESTORM-Guardian-SNS65S-Controls-Crawlspace-Dehumidifier-
\(1\)

If you have any questions, please feel free to contact us at (888)276-9833 or visit www.abestorm.com
Register your unit for warranty using this link: https://www.abestorm.com /service-warranty

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>