steinel RS PRO DL 150 SC LED Luminaire with Active Motion Detector Instruction Manual

August 26, 2024
STEINEL

steinel RS PRO DL 150 SC LED Luminaire with Active Motion Detector

Specifications

  • Brand: RS PRO
  • Model: DL 150 SC / DL 200 SC
  • Light Distribution Curve: 73 mm
  • Switchable Light Temperature: 3,000 K (warm white), 4,000 K (neutral white), 5,700 K (cold white)
  • Protection Rating: IP20 (ceiling/suspended ceiling), IP54 (room side)

Product Usage Instructions

Make sure to follow the provided electrical wiring diagram. The power supply cable consists of two wires: L = Phase (usually black, brown, or gray) N = Neutral wire (usually blue). Note that the light source of this fixture cannot be replaced. If replacement is necessary, the entire fixture must be replaced.

  • Be cautious of the electrical risks involved in the mounting process. Follow these steps:
  • For Under-ceiling Mounting: Range of 2.8m, use appropriate mounting brackets and springs.
  • For Side Motion Detection: Range of 7m, use under-ceiling mounting with proper adjustment.
  • For Forward Motion Detection: Range of 1m, ensure proper under-ceiling mounting.
  • Follow the specified mounting steps and use the correct number of spring clips based on ceiling thickness.
  • The product can be controlled via Android or iOS devices.
  • Default settings include a start-up time of up to 10 seconds, light intensity at 50%, and auto-adjustment based on ambient light up to 2,000 Lux. Basic light settings can be customized for both ambient and main lighting.
  • Exercise caution when performing maintenance tasks to avoid electrical hazards.
  • Regularly check for any signs of wear or damage and ensure all connections are secure. Remember to disconnect the power before any maintenance procedures.

FAQ

  • Q: Can the light temperature be adjusted?
  • A: Yes, the light temperature can be switched between warm white (3,000 K), neutral white (4,000 K), and cold white (5,700 K).
  • Q: What is the protection rating for this product?
  • A: The product has an IP20 protection rating for the ceiling/suspended ceiling side and IP54 for the room side.
  • Q: How should I handle maintenance tasks?
  • A: When performing maintenance, always ensure to disconnect the power supply to avoid any electrical hazards. Check for wear and tear regularly and maintain secure connections.

About this document

Under copyright. Reproduction either in whole or in part only with our consent.
Subject to change in the interest of technical progress.

  • Hazard warning!
  • Warning of hazards from electricity!
  • Do not cover the luminaire with thermal insulation materials!

General safety precautions

Failure to observe these operating instructions presents hazards!
These instructions contain important information on the safe use of this product. Particular attention is drawn to potential hazards. Failure to observe this information may lead to death or serious injuries.

  • Read instructions carefully.
  • Follow safety advice.
  • Keep instructions within easy reach.
  • Working with electrical current may produce hazardous situations.
  • Touching live parts can result in electrical shock, burns or death.
  • Work on mains voltage must only be performed by qualified, skilled personnel.
  • National wiring regulations and electrical operating conditions must be observed (e.g. DE: VDE 0100, AT: ÖVE-ÖNORM E8001-1, CH: SEV 1000).
  • Only use genuine replacement parts.
  • The external flexible cable or cord of this luminaire cannot be replaced.
  • If the cord is damaged, the luminaire shall be destroyed.
  • Supply cord 60227 IEC52; 2×0.75mm2.

System description

Proper use – DL 150/200 SC

  • Sensor-switched LED luminaire with active motion detector.
  • Recessed mounting.
  • Indoor use only.

DL 150/200 SC operating principle

  • The HF/radar motion detector emits high-frequency electromagnetic waves (5.8 GHz) and detects the echo reflected by objects.
  • The echo changed by the movement of the body is converted electronically and switches the luminaire ON automatically.
  • Movement can also be detected through thin walls, doors, and panes of glass.
  • Even the tiniest of movements can be detected.
  • No inadvertent triggering by heat sources or temperature fluctuations.
  • The sensor‘s detection zone can be precisely limited by using the reach setting capability on the web interface and via app.

Note
The high-frequency output of the HF sensor is approx. 1 mW – that‘s 1000 times less than the transmission power of a mobile phone or the output of a microwave.

Package contents

  • 1 LED luminaire
  • 1 junction box
  • 3 mounting springs
  • 3 connection clamps
  • 1 safety data sheet (A)
  • 1 Quick start guide (B)

Product Dimensions

Product Components

  • A …Luminaire
  • B … Junction box
  • C … Mounting springs
  • D … Connection clamps

Light distribution curve

Electrical connection

Circuit diagram

The mains supply lead is a 2-core cable:

  • L = phase conductor (usually black, brown, or grey)
  • N = neutral conductor (usually blue)

The luminaire can also be connected to the power supply downstream of a mains switch if it is ensured that the mains switch is left ON all the time.
The light source of this luminaire cannot be replaced. If the light source needs to be replaced (e.g. at the end of its service life), the complete luminaire must be replaced.

Installation

Hazard from electrical power.
Touching live parts can result in electrical shock, burns, or death.

  • Switch OFF the power and interrupt the power supply.
  • Using a voltage tester, check to make sure that the power supply is disconnected.
  • Make sure the power supply remains interrupted.

Risk of damage to property!
Mixing up connection leads may produce a short circuit.

  • Identify connection leads.
  • Connect the leads correctly.

Preparing for installation

  • Check all components for damage. Do not use the product if it is damaged.
  • Select an appropriate site to install the product.
  • Consider reach.
  • Take reach and motion detection into consideration.
  • Vibration-free.
  • No obstacles in the detection zone.
  • Not in explosive atmospheres.
  • Not on normally flammable surfaces.
  • Do not look into the light source from a short distance (< 30 cm).
  • Spaced at a distance of at least 50 cm from other LED luminaires.
  • Do not cover the luminaire with thermal insulation materials.

Reach, recessed mounting

  • Detecting motion across the direction in which a person walks – recessed mounting

  • Detecting motion in the direction in which a person walks – recessed mounting

Mounting procedure

  • Check to make sure the power supply is switched OFF.

  • Drill a hole.

  • Decide about the amount of the mounting springs.

Warning: It is not possible to remove the mounting spring after the first installation.

  • Press the mounting spring to the correct position.

  • Move the switch according to the required color temperature.

Optional accesory dimensions

  • Connect the mains power supply lead as shown in the wiring diagram.

  • → “4. Electrical connection”

  • Mount the luminaire into a ceiling.

IP rating

  • IP20 – in-ceiling side

  • IP54 – room side

  • Do not cover the luminaire with thermal insulation materials!

  • Switch ON the power supply.

  • Make settings via the app.

  • → “6. Function”

Function

Functions are set via the Steinel Connect app.
Steinel Connect app
To configure the luminaire via smartphone or tablet, you must download the STEINEL Connect app from your app store.
You will need a Bluetooth-capable smartphone or tablet.

Functions that can be set via the Steinel Connect app:

  • Time setting.
  • Reach setting.
  • Twilight setting.
  • Basic light level function.
  • Main light / basic light level adjustable.
  • Extended reach adjustment.
  • Group interconnection.
  • Twilight setting by teach-in.

Note
To rule out malfunctioning, a minimum distance of 3 m must be allowed from the Wi-Fi router and the access points.

Factory settings (state on leaving the factory)

  • Reach: max.
  • Main light time setting: 10 sec.
  • Basic light time setting: 1 min.
  • Twilight level: 2,000 lux
  • Basic light dimming level: 50 %

Commissioning/power interruption
The settings and current operating status of the LED luminaire are saved automatically in the event of power failure or disconnection from the power supply. Settings are reactivated as soon as the mains power supply is restored.

Reach setting (sensitivity)
Reach is the term used to describe the diameter of the more or less circular detection zone produced on the ground after mounting the sensor luminaire at a height of 2,8 m.

  • Set to maximum = max. reach (3,5 m)
  • Set to minimum = min. reach (1 m)

Time setting
The time (stay-ON time) can be set to any period from approx. 5 seconds to a maximum of 60 minutes. Every movement detected re-activates the luminaire.

Note
After the unit switches OFF, it takes approx. 1 second before it can start detecting movement again. The unit can then switch ON again in response to movement.
The shortest time setting is recommended when adjusting the detection zone and performing the functional test.

Twilight setting
The response threshold (twilight) can be infinitely varied from approx. 2 to 2,000 lux.

  • = daylight mode (depending on ambient light level)
  • = night-time operation (approx. 2 lux)

The control dial must be turned to when adjusting the detection zone and performing the functional test in daylight.

Basic light level

  • The brightness of the basic light level setting can be varied between 1% and 50%.
  • The period for which the basic light level stays ON for can be infinitely varied between 10 minutes and 30 minutes or set to remain ON all night.

Main light level
The brightness of the main light level setting can be varied between 50% and 100%.

Grouping

  • The unit can be operated as a separate luminaire or several luminaires can be interconnected in groups via wireless communication.
  • All luminaires belonging to a group operate in line with the group parameters set in the Steinel Connect app.
  • Reach can be set individually for all lights in the lighting group.

Fade time

  • Fade time can be used to set the rate of dimming on switching the light ON and OFF (1 s – 3 s).

Neighbouring-light function

  • The neighboring light function can be activated and deactivated via the Steinel Connect app.
  • This function assigns the neighboring groups to the active lighting group.
  • The active group responds to activation signals from the neighboring group assigned to it and switches to main light or basic light as defined in the settings.

Maintenance and care

  • The tool requires no maintenance.

Hazard from electrical power

  • Contact between water and live parts can result in electric shock, burns or death.
  • Only clean tool in a dry state.

Risk of damage to property!

  • Using the wrong cleaning product can damage the light.
  • Clean the tool with a moist cloth without detergent.

Important note: the control gear cannot be replaced.

Disposal
Electrical and electronic equipment, accessories and packaging must be recycled in an environmentally compatible manner.

  • Do not dispose of electrical and electronic equipment as domestic waste.

EU countries only
Under the current European Directive on Waste Electrical and Electronic Equipment and its implementation in national law, electrical and electronic equipment no longer suitable for use must be collected separately and recycled in an environmentally compatible manner.

Declaration of Conformity
STEINEL GmbH hereby declares that the RS PRO DL 150 SC and RS PRO DL 200 SC radio equipment type conform to Directive 2014/53 EU. The full wording of the EU Declaration of Conformity is available for downloading from the following internet address: www.steinel.de

Manufacturer’s warranty

Manufacturer’s warranty of STEINEL GmbH, Dieselstrasse 80-84, DE-33442 Herzebrock-Clarholz, Germany.
All STEINEL products meet the highest quality standards. For this reason, we, the manufacturer, are pleased to provide you, the customer, with a warranty under the following terms and conditions:
The warranty covers the absence of deficiencies that are proven to be the result of a material defect or fault in manufacturing and which are reported to us immediately after detection and within the warranty period.
The warranty shall cover all STEINEL Professional products sold and used in Germany.

Our warranty cover for consumers

  • The provisions below apply to consumers. A consumer is any natural person who, on entering into the purchase transaction, neither acts in exercising their commercial nor their self-employed activity.
  • You can opt for warranty cover in the form of repair or replacement which will be provided free of charge (if applicable, in the form of a successor model of the same or higher quality) or in the form of a credit note.
  • In the case of sensors, floodlights, and outdoor and indoor lights, the warranty period for the STEINEL Professional product you have purchased is 5 years in each case from the date on which the product was purchased.
  • We shall bear the shipping costs but not the transport risks involved in the return shipment.

Our warranty covers for entrepreneurs

  • The provisions below apply to entrepreneurs. Entrepreneur is a natural or legal person or partnership with a legal personality who or, on entering into the purchase transaction, acts in exercising their or its commercial or self-employed activity.
  • We have the option of providing warranty cover by rectifying deficiencies free of charge, replacing a product free of charge (if applicable, in the form of a successor model of the same or higher quality) or by issuing a credit note.
  • In the case of sensors, floodlights, and outdoor and indoor lights, the warranty period for the STEINEL Professional product you have purchased is 5 years in each case from the date on which the product was purchased.
  • Within the scope of warranty cover, we shall not bear your expenses accruing from subsequent fulfillment nor shall we bear your expenses for removing the defective product and installing a replacement product.

Statutory rights accruing from defects, gratuitousness
The warranty cover described here shall be applicable in addition to the statutory rights of warranty – including special consumer protection provisions – and shall not restrict or replace them. Exercising your statutory rights in the event of defects is gratuitous.
Exemptions from the warranty
All replaceable lamps are expressly excluded from this warranty.
In addition to this, the warranty shall not cover:

  • any wear resulting from use or any other natural wear of product parts or any deficiencies in the STEINEL Professional product that are attributable to wear caused by use or other natural wear,
  • any improper or non-intended use of the product or any failure to observe the operating instructions,
  • any unauthorized additions, alterations or other modifications to the product or any deficiencies attributable to the use of the accessory, supplementary or replacement parts which are not genuine STEINEL parts,
  • any maintenance or care of products that is not carried out under the operating instructions,
  • any attachment or installation that is not under STEINEL’s installation instructions,
  • any damage or loss occurring in transit.

Application of German law
The warranty shall be governed by German law excluding the United Nations Convention concerning the International Sale of Goods (CISG).

Making claims
If you wish to make a warranty claim, please send your product complete and carriage paid with the original receipt of purchase, which must show the date of purchase and product designation, either to your retailer or directly to us at STEINEL (UK) Ltd. – 25 Manasty Road, Axis Park, Orton Southgate, GB- Peterborough Cambs PE2 6UP United Kingdom.
For this reason, we recommend that you keep your receipt of purchase in a safe place until the warranty period expires.

Technical specifications

Troubleshooting

Unit without power.

  • Fuse is not switched ON or is faulty.
  • Switch ON fuse.
  • Change the faulty fuse.
  • Break in wiring.
  • Check wiring with a voltage tester.
  • Short circuit in mains power supply lead.
  • Check connections.
  • Any mains switch OFF
  • Switch ON mains switch.

The unit does not switch ON.

  • The wrong twilight setting was selected.
  • Reset the twilight setting.
  • Mains switch OFF.
  • Turn on the mains switch.
  • The fuse is not switched ON or is faulty.
  • Switch ON fuse.
  • Change the faulty fuse.
  • Rapid movements are being suppressed to minimize malfunctioning or detection zones too small or incorrectly defined.
  • Check and adjust the detection zone.
  • The light source is faulty.
  • The light source cannot be changed. Completely replace the unit.

The unit does not switch OFF

  • Continued movement within the detection zone.
  • Check the detection zone.
  • If necessary, limit or change the detection zone.

The unit switches ON when it should not.

  • Recessed light not mounted for detecting movement reliably.
  • Securely mount recessed light.
  • Movement occurred but was not identified by the observer (movement behind the wall, a small object moving in the immediate proximity of lamp, etc.).
  • Check the detection zone.
  • If necessary, limit or change the detection zone.