Specifications:
-
Product: TPOne Programmable Room Thermostat
-
Functionality: Programmable room thermostat for intelligent
heating control -
Default Temperature Settings:
- Weekdays: 6:30 – 22:30 (Weekend: 07:30 – 22:30)
- Comfort Mode: 11:30 – 13:30
Product Usage Instructions:
Accessing Menu:
To access the menu, press the “Menu” button. The User Menu will
be displayed first. Use the navigation buttons to scroll through
various options.
Selecting Options:
Press “OK” to select menu options or confirm settings. The “OK”
indicator will be displayed when available. Press “O” to exit an
option.
Comfort Modes:
-
Away Mode: Selects the away comfort
temperature when the home is unoccupied. Set the temperature in
User Menu > Temperatures. -
Asleep Mode: Sets the nighttime comfort
temperature. Select the required temperature in User Menu >
Temperatures.
Activating Hot Water Settings:
To activate hot water settings, access the User Menu, go to
Installer Settings, find Hot Water Setup, change setting to Yes,
then set up the schedule in scheduling.
Scheduling Programs:
In the User Menu, scroll down to Schedule, select heating, then
choose hot water by scrolling up. Set the schedule accordingly.
FAQ:
Q: How do I reset the TPOne thermostat to factory
settings?
A: To reset to factory settings, navigate to Installer Settings
and look for Factory Reset option. Confirm the reset to revert all
settings to default.
Q: Can I override the programmed schedule temporarily?
A: Yes, you can manually override the programmed schedule by
adjusting the temperature using the up and down buttons on the
thermostat.
“`
About the heating in your home….
What is a programmable room thermostat?
A programmable thermostat allows you to set On’ and
Off’ time periods to
suit your own lifestyle. A room thermostat works by sensing the air
temperature and switching on the heating when the air temperature falls below
the thermostat setting, switching it off once this set temperature has been
reached. The TPOne programmable room thermostat has made intelligent heating
control easier than ever before.
Accepting schedule default settings
The TPOne has pre-set times and temperatures already programmed in, which
often suit most people. (see table below).
TPOne Thermostat
1
2
3
Comfort modes Display
Navigation
TEMPERATURE DEFAULTS
6:30 – 22:30 (Weekend 07:30 – 22:30)
06:30 – 08:30 (Weekend
07:30 – 09:30)
06:30 – 08:30 (Weekend
07:30 – 09:30)
AM 20°C PM 20°C
11:30 – 13:30
15°C 15°C
Navigation
Menu
Press Menu to access the intuitive text menu. The common feature User Menu will be displayed first. Additional settings can found in the User Setting option and more advance settings can be found in the Installer Setting option.
Select / Press OK to select menu options or confirm settings. OK will be shown on the Confirm display when it can be used or is required.
Press O to exit a menu option. Pressing O while in a setting will result in that Menu Back setting change not be accepted. O will also exit the menu system. O will be
shown on the display when it can be used
The Navigation buttons are used to navigate the TPOne menus and change
Navigation
setting values. The up & down buttons are also used to manually change the required temperature. Navigation arrows will be shown on the display when
these buttons can be used.
Comfort modes
Home Mode selects the home comfort temperature typically when the home is
occupied during the day. The required temperatures for Home mode are
selectable in the Temperature setting (see User Menu > Temperatures.) A
separate Home AM and Home PM temperature can be chosen and these are
automatically set according to the time of the day. Note: When in Home mode if
the home button is pressed again a 1, 2 or 3 hour heating boost is selected
and the current home period is extended by the chosen time period. The chosen
boost period is displayed under the Home icon on the display.
Away Mode selects the away comfort temperature typically when the home is
unoccupied during the day. The required temperature for Away mode is
selectable in the Temperature setting (see User Menu > Temperatures).
Asleep Mode selects the nighttime comfort temperature which is set between the
end of the last home period of the day and the beginning of the first home
period of the following day. The required temperature for Asleep mode is
selectable in the Temperature setting (see User Menu > Temperatures).
Standby The TPOne can be placed in Standby Mode. While in Standby the TPOne
will not control the heating system other than to protect against frost damage
(see User Menu > Installer Settings > Frost Protect for information on frost
protect). Standby can be cancelled by pressing the Standby button again or by
selecting another comfort mode. Note: the standby option places the heating
control in standby only, if Hot Water is set up this is not affected. To
switch Hot Water control off see User Menu > Hot Water > Mode
Icons
16:30 – 22:30 16:30 – 22:30
Note: Where TPOne has been set up for domestic hot water control the default
schedule for hot water is the same as for heating. In schedule set up user can
set one, two or three ON periods, TPOne will automatically fill in gaps with
OFF periods
Activating hot water settings
To activate the hot water settings you need to access the user menu and find
Installer Settings and scroll through until you find Hot Water Setup then
press OK, you will see No and then you can press the right hand arrow and this
will change to Yes now allowing you to set up the schedule in scheduling.
Scheduling Programs
Access the user menu and scroll down to schedule then press OK, once here
press on and you will see heating appear with an up and down arrow, scroll up
and you will see hot water then press ok and you can set the schedule
accordingly.
Installer details
For a visual guide please go to YouTube and search for Danfoss TPOne www.youtube.com