ECCO EC101 Connect Kit Instruction Manual

August 16, 2024
ECCO

ECCO EC101 Connect Kit

Specifications

  • Input Voltage: 12VDC
  • Input Current: Varies based on the hardware selected
  • Temp. Range: Page 1 of 7

IMPORTANT! Read all instructions before installing and using. Installer: This manual must be delivered to the end user.

WARNING!
Failure to install or use this product according to the manufacturer’s recommendations may result in property damage, serious injury, and/or death to those you are seeking to protect!

Do not install and/or operate this safety product unless you have read and understood the safety information contained in this manual.

  1. Proper installation combined with operator training in the use, care, and maintenance of emergency warning devices are essential to ensure the safety of emergency personnel and the public.
  2. Emergency warning devices often require high electrical voltages and/or currents. Exercise caution when working with live electrical connections.
  3. This product must be properly grounded. Inadequate grounding and/or shorting of electrical connections can cause high current arcing, which can cause personal injury and/or severe vehicle damage, including fire.
  4. Proper placement and installation are vital to the performance of this warning device. Install this product so that the output performance of the system is maximized and the controls are placed within convenient reach of the operator so that they can operate the system without losing eye contact with the roadway.
  5. Do not install this product or route any wires in the deployment area of an airbag. Equipment mounted or located in an airbag deployment area may reduce the effectiveness of the airbag or become a projectile that could cause serious personal injury or death. Refer to the vehicle owner’s manual for the airbag deployment area. It is the responsibility of the user/operator to determine a suitable mounting location ensuring the safety of all passengers inside the vehicle particularly avoiding areas of potential head impact.
  6. It is the responsibility of the vehicle operator to ensure daily that all features of this product work correctly. In use, the vehicle operator should ensure the projection of the warning signal is not blocked by vehicle components (i.e., open trunks or compartment doors), people, vehicles, or other obstructions.
  7. The use of this or any other warning device does not ensure all drivers can or will observe or react to an emergency warning signal. Never take the right-of-way for granted. It is the vehicle operator’s responsibility to be sure they can proceed safely before entering an intersection, drive against traffic, respond at a high rate of speed, or walk on or around traffic lanes.
  8. This equipment is intended for use by authorized personnel only. The user is responsible for understanding and obeying all laws regarding emergency warning devices. Therefore, the user should check all applicable city, state, and federal laws and regulations. The manufacturer assumes no liability for any loss resulting from the use of this warning device.

Specifications

  • Input Voltage: 12VDC
  • Input Current : Varies based on the hardware selected
  • Temp. Range:
    • 40ºC to 65ºC
    • 40ºF to 149ºF

Kit Contents

This kit is designed to integrate one 12+ Pro lightbar (standard wiring option) and up to four different directional lights within the same ECCO CONNECT system. The flash patterns come pre-programmed in the SIB. Use the instructions below to install this system. If you run into any questions, please reach out to our Tech Support team. We’ll be happy to assist.

Installation and Mounting

  1. Install the SIB, SWITCHNODE, and (if ordered) EZ0000 controller inside the cab on a flat surface that is safe from moisture. Follow the provided instructions for mounting each product.
  2. Mount the exterior lighting directionals in the desired locations of the vehicle. Note: Drill a 1” hole for the wire exit of the directional.
  3. Mount the 12+ Pro lightbar per the install instructions included with the lightbar. Route the control cable back to the Switch node. The control cable is included with a lightbar and comes in three different lengths (15’, 23’, 48’). Program the 12+ flash patterns using the “Pattern Select” wire (purple wire). Reference the install instructions included with the 12+ for details. Note: The 12+ flash patterns run independently from the rest of the system and will not be in sync.

Wiring Instructions

  1. Use 8 AWG Ring Terminal and 8 AWG wires to connect the Switch node positive terminal to +12V or +24V.
  2. Use 10-12 AWG Ring Terminal and 10 AWG wire to connect the Switch node negative terminal to the ground.
  3. Connect the EZ0000 power and input connectors into the SIB. Connect the two red wires to +12V or +24V and black to the ground.
  4. Connect the Switch node to the Serial Interface Box by plugging the CAN 690-0499-00 and 690-1051-00.
  5. Route Cables from the Switch node to each directional. Connect Deutsch connections.
  6. Connect the 12+ lightbar to the Switch node using the lightbar connector.
  7. Connect Switchnode Junction Harness according to the image below.
  8. If you are connecting the SIB input wires to switches, select the desired SIB input wires to use based on the flash pattern table in this install guide. The remaining unused input wires can be trimmed and capped.
  • A – SIB AUX PORT
    • FRONT RIGHT
    • 12+ CONNECTOR WITH BROWN & ORANGE WIRES
    • 12+ CONNECTOR WITH GREEN & YELLOW WIRES
    • FRONT LEFT
    • REAR LEFT
    • 12+ CONNECTOR WITH BLUE WIRE
    • (NOT USED)
    • REAR RIGHT

List of primary/secondary colors by product

Reference the guidance below to connect each product back to the correct Switchnode outputs. The 12+ Pro will use three connectors (#2, 3, 6)

Two different cable options are available to connect the directionals to the Switch node. Cables can be combined to create a longer extension. Note, that the lightbar does not require extension cables, use the control cable provided with the lightbar to route back to the Switch node. Route the cables below using the guidance provided below.

Warranty

Manufacturer Limited Warranty and Limitation of Liability:
The manufacturer warrants that on the date of purchase, this product will conform to the Manufacturer’s specifications for this product (which are available from the Manufacturer upon request). This Limited Warranty extends for sixty (60) months from the date of purchase.

DAMAGE TO PARTS OR PRODUCTS RESULTING FROM TAMPERING, ACCIDENT, ABUSE, MISUSE, NEGLIGENCE, UNAPPROVED MODIFICATIONS, FIRE, OR OTHER HAZARD; IMPROPER INSTALLATION OR OPERATION; OR NOT BEING MAINTAINED BY THE MAINTENANCE PROCEDURES OUTLINED IN MANUFACTURER’S INSTALLATION AND OPERATING INSTRUCTIONS VOIDS THIS LIMITED WARRANTY.

Exclusion of Other Warranties

THE MANUFACTURER MAKES NO OTHER WARRANTIES, EXPRESSED OR IMPLIED. THE IMPLIED WARRANTIES FOR MERCHANTABILITY, QUALITY, OR FITNESS FOR A PARTICULAR PURPOSE, OR ARISING FROM A COURSE OF DEALING, USAGE, OR TRADE PRACTICE ARE HEREBY EXCLUDED AND SHALL NOT APPLY TO THE PRODUCT AND ARE HEREBY DISCLAIMED, EXCEPT TO THE EXTENT PROHIBITED BY APPLICABLE LAW. ORAL STATEMENTS OR REPRESENTATIONS ABOUT THE PRODUCT DO NOT CONSTITUTE WARRANTIES.

Remedies and Limitation of Liability:

MANUFACTURER’S SOLE LIABILITY AND BUYER’S EXCLUSIVE REMEDY IN CONTRACT, TORT (INCLUDING NEGLIGENCE), OR UNDER ANY OTHER THEORY AGAINST MANUFACTURER REGARDING THE PRODUCT AND ITS USE SHALL BE, AT MANUFACTURER’S DISCRETION,
THE REPLACEMENT OR REPAIR OF THE PRODUCT, OR THE REFUND OF THE PURCHASE PRICE PAID BY THE BUYER FOR A NON-CONFORMING PRODUCT. IN NO EVENT SHALL THE MANUFACTURER’S LIABILITY ARISING OUT OF THIS LIMITED WARRANTY OR ANY OTHER CLAIM RELATED TO THE MANUFACTURER’S PRODUCTS EXCEED THE AMOUNT PAID FOR THE PRODUCT BY THE BUYER AT THE TIME OF THE ORIGINAL PURCHASE. IN NO EVENT SHALL MANUFACTURER BE LIABLE FOR LOST PROFITS, THE COST OF SUBSTITUTE EQUIPMENT OR LABOR, PROPERTY DAMAGE, OR OTHER SPECIAL, CONSEQUENTIAL, OR INCIDENTAL DAMAGES BASED UPON ANY CLAIM FOR BREACH OF CONTRACT, IMPROPER INSTALLATION, NEGLIGENCE, OR OTHER CLAIM, EVEN IF MANUFACTURER OR A MANUFACTURER’S REPRESENTATIVE HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. THE MANUFACTURER SHALL HAVE NO FURTHER OBLIGATION OR LIABILITY CONCERNING THE PRODUCT OR ITS SALE, OPERATION, AND USE, AND THE MANUFACTURER NEITHER ASSUMES NOR AUTHORIZES THE ASSUMPTION OF ANY OTHER OBLIGATION OR LIABILITY IN CONNECTION WITH SUCH PRODUCT.

This Limited Warranty defines specific legal rights. You may have other legal rights which vary from jurisdiction to jurisdiction.
Some jurisdictions do not allow the exclusion or limitation of incidental or consequential damages.

Frequently Asked Questions

  • Q: What should I do if I encounter issues with the installation?
    • A: If you have any questions or encounter issues during installation, please reach out to our Tech Support team for assistance.

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>