Saxby lighting 107141 RularPRO EM LED Batten Instruction Manual
- August 16, 2024
- saxby lighting
Table of Contents
Saxby lighting 107141 Rular PRO EM LED Batten Instruction Manual
Warning
This is a Class 1 product and must be earthed. Please read these
instructions carefully before commencing any work
This unit must be fitted by a competent and qualified electrician.
Check the pack and make sure you have all the parts listed.
Install in accordance with the IEE Wiring regulations and current Building
Regulations. To prevent electrocution switch off at mains supply before
installing or maintaining this ftting. Ensure other persons cannot restore the
electrical supply without your knowledge. If you are in any doubt, please
consult a qualified electrician. This light ftting should be connected to a
fused circuit.
If replacing an existing fitting, make a careful note of the connections.
Waste electrical products should not be disposed of with household waste.
Please recycle where facilities exist. Check with your local authority or
retailer for recycling advice.
Layout
Plan the desired layout of these fittings carefully, ensuring the cables will
reach the distances between the junction box and the. each light ftting Avoid
locating any cables in positions that would cause a hazard. Position cables
and outdoor rated junction boxes (not supplied) away from areas where they may
be at risk from being out, rapped o damaged.
The mains supply cable must have a minimum cross section area of 1.0mn’.
Cables must be protected using suitable conduit or plastic trucking.
Take care not to drill into any pipes or mains cables beneath the surface
during mounting holes preparation.
This product can be installed on the ceiling or wall,
Installation
Existing fittings must be completely removed before installation of a new
product. Before removing the existing fitting, carefully note the position of
each set of wires.
Note that the switch is turned off before installation.
‘The mounting surface must be flat and smooth to ensure a good fit.
The wastage is changeable by using the wattage switch on the driver.
For the 107141 is the 31.5W / 20W selectable
For the 107142 is the 39W / 26W selectable
For the 107143 is the 44W / 35W selectable
The colour is changeable between 3000/4000/6000K using the CCT switch on the
driver before installation.
Choose your preferred wattage and colour before installing by wattage switch
or CCT switch on the driver. Note: Before you change the wattage or colour,
please turn off the power switch for safety.
- Hold the product in place and mark the position of the fixing holes. This may require the help of an assistant. If wall mounting, ensure that the product is level.
- Take care to avoid damaging any concealed wiring and pipes. The correct fixings should be used for bricks, cavity walls or plasterboard.
- Ensure the ceiling or wall is capable of holding the weight of the product and then fix brackets in place.
- Rotate both ends of the product in the direction of the arrow to open the diffuser cover.
- Find the EM kit inside the lamp, drill out the the hole on one side of the lamp body to insert the Test Switch.
- Pull the supply cable through the middle grommet and fix the light fitting into position using appropriate fixings.
- Connect the supply cable to the quick fit terminal block as detailed wiring diagram.
- Connect the battery output cable to the EM driver.
- Close diffuser cover into place.
- Replace fuse or circuit breaker and switch on. Your light is now ready for use.
CONNECTION
Model | X |
---|---|
4FT | 1050±10mm |
5FT | 1350±10mm |
6FT | 1650±10mm |
Wiring
This product is Class I product must be earthed. They must be joined
together and well insulated with good quality insulation tape. This is to
ensure earth continuity throughout your property. Having correctly identified
the wiring from your existing light fitting and connect to the connection
block inside the product in the way on the right:
Check that…
- You have correctly identified the wires.
- The connections are tight.
- No loose strands have been left out of the connection block.
Maintained(Unstitched) Wiring:
The product on permanently and comes on during a power failure.
Maintained (Switched) Wiring:
The product is used as a normal light switch on/off, light turns on/off. Comes
on during a power failure.
Non-Maintained Wiring:
The product is normally off and comes on during a power failure.
Technical data
Supply
Voltage: 220-240 V, 50 Hz
Bulb: 107141: 31.5W/20W LED module (SMD) CCT, 3000K/4000K/6000K
Type: 107142 39W/26W LED module (SMD) CCT, 3000K/4000K/6000K 107143:
44W/35W LED module (SMD) CCT, 3000K/4000K/6000K This product contains a light
source of energy efficiency class C.
Non-replaceable light source
Conformity with all relevant UKCA Directive requirements.
This product is Class 1, must be connected to earth.
Waste electrical products should not be disposed of with household waste. Please recycle where facilities exist. Check with your Local Authority o local store for recycling advice.
This product is not suitable for dimming.
This product s for indoor use only.
Replaceable control gear by a professional
Conformity with all relevant EC Directive requirements.
Duration: 3 hours (180 Minutes)
Mains input current: 22mA
input power in mains operation: 2.5W
Emergency power: 1W (Battery)
Battery Specification: LiFePO4 3.2V 1500mAH
Battery Charge Time: 24 Hours
Battery charge current: 200mA
Battery warranty: 5 years Operating
Temperature: 0°C-45°C
Care and Safety
Live Voltages may be present in this unit even when turned off or when
completely disconnected.
We recommend cleaning with a soft dry cloth. Do not use solvents or abrasive
cleaners s these could damage the finish.
For your safety, always switch off the power supply before cleaning.