TZS FA-2461-6-BA First Austria Weather Station User Manual

August 16, 2024
TZS

TZS FA-2461-6-BA First Austria Weather Station User Manual

FEATURES

  • Time in optional 12/24 hour format.
  • Daily Alarm Function
  • Snooze function(OFF or 1~60min)
  • Low battery indicate
  • Humidity: Indoor & Outdoor measurable range: 20%RH ~ 95%RH
  • Temperature:
    • Indoor temperature measurement ranges: -9.9°C (14.2°F) ~ 50°C (122°F)
    • Outdoor temperature measurement ranges: -25°C (-13°F) ~ 50°C (122°F)
    • Temperature alternatively in °C or °F.
    • Outdoor thermometer ice alert
  • Maximum /minimum value record of temperature and humidity
  • Wireless Outdoor Sensor:
    • Wall Mount or Table Stand
    • 433.92MHz RF transmitting frequency
    • 60-meter transmission range in an open area
  • Weather forecasting function
  • Power Supply:
    • Weather Station:
    • Battery: 2 x LR06 AA
    • Wireless Outdoor Sensor:
    • Battery: 2 x LR03 AAA

MAIN UNIT APPEARANCE

Part A- LCD (Fig. A) A1: Weather Forecasting

  • A2: Outdoor Temperature
  • A3: Outdoor Humidity
  • A4: Indoor Temperature
  • A5: Indoor Humidity
  • A6: Time

Part B – Back button and power (Fig. B)

  • B1: “SNOOZE/LIGHT” touch key
  • B2: “SET” button
  • B3: “MEM” button
  • B4:“+” button
  • B5: “-” button
  • B6: Battery compartment

WIRELESS OUTDOOR SENSOR

Part C – Wireless Outdoor Sensor

C1: Wireless Outdoor Sensor battery compartment Wireless remote sensor (transmitter)

  • Transmitter frequency: 433.92 MHz.
  • The range of transmission is up to 60m (200 feet).
  • Insert the 2 batteries into the transmitter.
  • Pay attention to observing the correct polarity.

INITIAL OPERATION

  • Open the Weather Station Battery compartment cover
  • Insert 2 x AA batteries observing polarity [ “+” and “ –“ marks]
  • When you insert the batteries, all the icons on the LCD will light up for 3 seconds, and you will hear a beep tone, then detect indoor temperature & humidity.
  • The Weather Station will now start to make a connection to the outdoor remote sensor.
  • This operation takes about 3 minutes and is displayed by a flashing reception RF antenna the symbol in the “OUTDOOR” display area on the receiver.
  • This now, Opens the remote Sensor battery compartment cover, Insert 2 x AAA batteries observing polarity [ “+” and “–“ marks]
  • After the receiver has created a connection to the outdoor remote sensor, After 3 minutes it will Exit RF mode.

MANUAL TIME SETTING

  • Press and hold the “SET” button for 2 seconds, and the temperature unit starts to flash. Now use the “+” and “-” buttons to set the temperature unit in °C or °F you need.
  • Press the “SET” button to confirm your setting, and the 12/24HR starts to flash. Now use the “+” and “-” buttons to set the 12/24 hour mode you need.
  • Press “SET” to confirm your setting, and the Time zones start to flash, Now use the “+” and “-” buttons to set the correct time zone (-12 to +12).
  • Press “SET” to confirm your setting, and the Hour display starts to flash. Now use the “+” and “-” buttons to set the correct hour.
  • Press “SET” to confirm your setting, and the minute display starts to flash. Now use the “+” and “-” buttons to set the correct minute.
  • Press the “SET” button to confirm your setting, and the weather forecast pattern display starts to flash. Now use the “+” and “-” buttons to select the current weather pattern.
  • Press “SET” to confirm your setting and to end the setting procedures, Then it will return to the normal mode.

F.Y.I.

  • If there is no valid operation within 20 seconds, it will automatically return to normal time mode from the set mode.

Setting the daily alarms

  • Press once “+” button, LCD the “ ”, and the alarm function is ON. Then press once “+” button, the “ ” icon will disappear from the display, and the alarm function is OFF.
  • Press once “SET” button, LCD alarm time, then Press and hold the “SET” button for 2 seconds until the hour of the Alarm time starts to flash. Use the “+” and “-” buttons to set the required hour.
  • Press the “SET” button to confirm your setting, The Minute of the Alarm time starts to flash. Use the “+” and “-” buttons to set the required minute.
  • Press the “SET” button to confirm your setting, and the snooze time of the Alarm starts to flash. Use the “+” and “-” buttons to set the minute of snooze you need.
  • Press the “SET” button to confirm your settings and to end the setting procedure.

F.Y.I.

  • If there is no valid operation within 20 seconds, it will automatically return to normal time mode from the alarm time set mode.
  • The alarm will sound for 2 minutes if you do not deactivate it by pressing any button. In this case, the alarm will be repeated automatically after 24 hours.
  • Rising alarm sound (crescendo, duration: 2 minutes) changes the volume 4 times whilst the alarm signal is heard. Switching off the alarm signal
  • When the alarm is ringing, press any button except the “SNOOZE/LIGHT” button to stop the alarm signal. It is not necessary to reactivate the alarm. It will ring again this time the next day.

Snooze function
When the alarm is ringing, touch the “SNOOZE/LIGHT” button the alarm mode will go to SNOOZE mode. The alarm signal sounds again after already been set.

RF Transmission Procedure

  • The weather station automatically starts receiving a transmission from the outdoor thermo sensor for outdoor temperature & humidity after the batteries are inserted. transmission from the outdoor thermo sensor for outdoor temperature after batteries are inserted.

  • The remote sensor will automatically transmit temperature and humidity signals to the Weather Station after batteries are inserted.

  • If the Weather Station fails to receive a transmission from the outdoor sensor (“- -.-” display on the LCD), press and hold the “-” button for 3 seconds to receive transmission manually. RF icon “ ” flashes on the LCD. The Weather Station to receive the remote sensor. Query Maximum/minimum numerical value

  • When the indoor/outdoor temperature/humidity is shown on the LCD, The weather station begins to record the temperature/humidity maximum and minimum numerical values.

  • Press once “MEM” button once, and the LCD will display the maximum value of temperature/ humidity, The LCD will display the minimum value of temperature/humidity if once “MEM” button again when the maximum value is displayed.
    at the same time, there are “MAX” or “MIN” displayed on the LCD.

  • The temperature/humidity maximum/minimum value will RE recorded after pressing and holding the “MEM” button for 3 seconds.

F.Y.I.

  • If the temperature reading is below ranges, the LL.L will be displayed. If the temperature reading is above ranges, the HH.H will be displayed.

Ice alert

  • The ice alert symbol appears and flashes next to the outdoor temperature when the outdoor temperature at –1°C to + 3°C or +30°F to + 37°F.

Weather forecasting function

  • Please take the weather forecast from your local weather forecasting service into account as well as the forecast from your weather station. If there are discrepancies between the information from your device and the local weather forecasting service, please take the advice of the latter as authoritative.

  • The weather forecast is calculated based on the following humidity & temperature data and may deviate from the actual weather conditions if the station in the central heating room or the humidity & temperature record is big different from the real natural state.
    Please see table 1&2

  • The weather station displays the following weather symbols: sunlight light cloudy, cloudy and rainy

  • The weather symbols indicate the weather fluctuation over the next eight hours and not the current weather.

Download PDF:TZS FA-2461-6-BA First Austria Weather Station User Manual

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals