Panasonic WH-WDG05LE5 Heat Pump Outdoor Unit Instruction Manual

August 15, 2024
Panasonic

WH-WDG05LE5 Heat Pump Outdoor Unit

“`html

Specifications:

  • Model: Aquarea Single Fan L generation
    AIO

  • Flow Rate:

    • 5kW – 14.3 l/min, 22 mm
    • 7kW – 20.7 l/min, 22 mm
    • 9kW – 25.8 l/min, 28 mm

Product Information:

Description: Typical schematic drawing for
piping layout of L Generation AIO

Legend:

  • H1 – Heat Pump Outdoor unit

  • H3 – Refrigerant inside the Heat Pump is R290

  • H4 – Magnetic Particle Filter is inside Indoor unit

  • H5 – Mains (city) water connection

  • H6 – 10L Expansion Vessel (heating) is inside Indoor unit,
    additional vessel maybe required to meet system requirements

  • H8 – Auto Bypass – minimum 1 full bore recommended

  • H11 – Heat Distribution system

  • H21 – Expansion Vessel (Cold Water)

  • H22 – Domestic Hot Water Circuit

  • H30 – Anti-freeze valves (PAW-A2W-AFVLV)-optional, 2 required
    per heat pump

  • H85 – Discharge pipework (Must be compliant with local
    laws)

Product Usage Instructions:

Piping Layout:

Ensure the correct piping layout is followed as per the provided
schematic drawing for the L Generation AIO model.

Electrical Layout:

Refer to the installation manual for the electrical layout
schematic and follow the guidelines provided for direct,
single-zone setup with Panasonic controls.

FAQ:

Q: What is the flow rate for each model?

A: The flow rates are as follows:

  • 5kW model – 14.3 l/min, 22 mm
  • 7kW model – 20.7 l/min, 22 mm
  • 9kW model – 25.8 l/min, 28 mm

Q: What are the key components included in the product?

A: The product includes components such as the Heat Pump Outdoor
unit, Refrigerant R290, Magnetic Particle Filter, Expansion
Vessels, and various valves for proper operation.

“`

H22

General Notes:
· Scan QR Code for a link to the Aquarea Installation Guide

H21

WH-WDG05LE5 (5kW) WH-WDG07LE5 (7kW) WH-WDG09LE5 (9kW)
H1 H3
H30

WH-ADC0509L3E5UK H4 H6
H85

H8
T

H11

· Please ensure that you have attended training and have read the installation and operation manuals regarding this product
· Panasonic accept no responsibility for the design or errors, schematic is for indication purposes only
· Pending of water test, correct inhibitor levels and biocide should be used
· Freeze protection must be considered using either glycol or anti-freeze valve’s
· By-pass required if flow rate is not sufficient when rad valves are closed
· Please ensure PRV/ PTRV discharge discharge pipework is compliant with local laws
· Maximum distance between indoor and outdoor unit is 30m
Flow Pipework Return Pipework Discharge pipework Isolation Valve Anti-freeze valves (optional)
Non Return Valve
Pressure Regulator
Safety Valve Bypass Valve

H5

Legend:
H1 Heat Pump Outdoor unit H3 Refrigerant inside the Heat Pump is R290 H4 Magnetic Particle Filter is inside Indoor unit H5 Mains (city) water connection H6 10L Expansion Vessel (heating) is inside Indoor unit,
additional vessel maybe required to meet system requirements H8 Auto Bypass – minimum 1″ full bore recommended

H11 Heat Distribution system H21 Expansion Vessel (Cold Water)
H22 Domestic Hot Water Circuit
H30 Anti-freeze valves (PAW-A2W-AFVLV)-optional, 2 required per heat pump H85 Discharge pipework (Must be compliant with local laws)

Aquarea Single Fan L generation AIO

Model

Flow Rate

Min. Pipe Size Ø*

5kW

14.3 l/min

22 mm

7kW

20.7 l/min

22 mm

9kW

25.8 l/min

28 mm

  • calculated at dT5. Pipework sizes stated for copper

Description:
Typical schematic drawing for piping layout of L Generation AIO
Piping Layout Schematic:
Direct, single zone, Panasonic controls

*Panasonic is not responsible, directly, or indirectly, towards users and in general towards any third party for any delays, inaccuracies, errors, omissions, damages (direct, indirect, consequential, and punishable) arising from such contents. Drawing Number:

Issue:

Texts, photos, graphics, may not be published, rewritten, marketed, and distributed by users and third parties in general, in any way and in any form if not expressly indicated in written form by Panasonic itself.

L-AIO-D-1P

1.0

Notes:
Note E26: Main Board PCB – The maximum cable length for sensor inputs in 30 meters and the maximum cable length for outputs and other inputs is 50m
Note E33: Panasonic Remote Controller – The Panasonic heat pump controller can be used as a room thermostat for one circuit only. The maximum cable length is 50 meters

E33 WH-ADC0509L3E5UK

WH-WDG05LE5 (5kW) WH-WDG07LE5 (7kW) WH-WDG09LE5 (9kW)

T
E63

Legend:
E33 Panasonic remote controller E63 Connection to the outdoor unit: The outdoor unit power supply comes/communication from the indoor unit,
so it is not necessary to bring a direct power supply to the outdoor unit

Aquarea L generation AIO WH-ADC0509L3E5UK

Model
WH-WDG05LE5 WH-WDG07LE5 WH-WDG09LE5

Power Supply Cord Isolating Devices

1

25A

2

15/16A

Recommended RCD
30mA, 2P, type A
30mA, 2P, type AC

  • Refer to installation manual for IEC/EN61000-XX compliance requirements

Description:
Typical schematic drawing for electrical layout of L Generation AIO
Piping Layout Schematic:
Direct, single zone, Panasonic controls

*Panasonic is not responsible, directly, or indirectly, towards users and in general towards any third party for any delays, inaccuracies, errors, omissions, damages (direct, indirect, consequential, and punishable) arising from such contents. Drawing Number:

Issue:

Texts, photos, graphics, may not be published, rewritten, marketed, and distributed by users and third parties in general, in any way and in any form if not expressly indicated in written form by Panasonic itself.

L-AIO-D-1P

1.0

E26 E33
E33

Notes:
Note E26: Main Board PCB – The maximum cable length for sensor inputs is 30 meters and the maximum cable length for outputs and other inputs is 50m

E60

E61

E62

E63

LN

L1 N1

12

3

Outdoor Unit
connection

Consumer Unit

Legend:
E26 Main board PCB – see notes E26 E33 Panasonic remote controller E60 Indoor Unit Power Supply E61 Unit Power Supply 1 – Main compressor unit power supply E62 Unit Power Supply 2 – Electric Back-Up Heater E63 Connection to the outdoor unit: The outdoor unit power supply/ communication comes from the indoor unit,
so it is not necessary to bring a direct power supply to the outdoor unit

Aquarea L generation AIO WH-ADC0509L3E5UK

Model
WH-WDG05LE5 WH-WDG07LE5 WH-WDG09LE5

Power Supply Cord Isolating Devices

1

25A

2

15/16A

Recommended RCD
30mA, 2P, type A
30mA, 2P, type AC

  • Refer to installation manual for IEC/EN61000-XX compliance requirements

Description:
PCB Connections – AIO heat pump system
Piping Layout Schematic:
Direct, single zone, Panasonic controls

*Panasonic is not responsible, directly, or indirectly, towards users and in general towards any third party for any delays, inaccuracies, errors, omissions, damages (direct, indirect, consequential, and punishable) arising from such contents. Drawing Number:

Issue:

Texts, photos, graphics, may not be published, rewritten, marketed, and distributed by users and third parties in general, in any way and in any form if not expressly indicated in written form by Panasonic itself.

L-AIO-D-1-P

1.0

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals