SJE RHOMBUS Tank Alert I Alarm System Owner’s Manual
- August 14, 2024
- SJE RHOMBUS
Table of Contents
SJE RHOMBUS Tank Alert I Alarm System
Product Usage Instructions
Installation:
- Ensure the power line is properly connected to reduce the possibility of shock.
- Mount the alarm enclosure in a suitable indoor location.
- Connect the float switch to the designated terminal without applying power.
- Place the alarm horn where it can be heard clearly in case of an alarm condition.
Operation
To operate the liquid level alarm system:
- Ensure the power cord is connected to a suitable power source.
- If the water level reaches the set high or low levels, the alarm will activate.
- Monitor the alarm and take appropriate action to address the water level issue.
FAQ
Q: What should I do if the alarm does not sound when the water level is high/low?
A: Check the power connection, float switch, and ensure the alarm settings are correctly configured. If issues persist, contact customer support for assistance.
Q: Can I use this alarm system outdoors?
A: No, this alarm system is designed for indoor use only.
This alarm system monitors liquid levels in lift pump chambers, sump pump
basins, holding tanks, sewage, agricultural, and other water applications.
The Tank Alert® I alarm system can serve as a high or low level alarm
depending on the float switch model used.
The alarm horn sounds when a potentially threatening liquid level condition
occurs. The horn can be silenced, but the warning light remains on until the
condition is remedied. A green “power on” light indicates power to the alarm
panel.
FEATURES
- NEMA 1 enclosure, designed for ease of installation, rated for indoor use
- Red “alarm” light, green “power on” light, alarm “test” switch, and horn “silence” switch
- Alarm horn sounds at 86 decibels at 10 feet (3 meters)
- Can be used with any UL Listed / Recognized switching mechanism rated to include 1 amp, 12 VAC load
- Alarm system (when installed on separate circuit) operates even if the pump circuit fails
- Switching mechanism operates on low voltage and is isolated from the power line to reduce the possibility of shock
OPTIONS
When ordered with the alarm, this system is available with:
- Alternate float switch models for high or low level warning
- 120 VAC primary voltage or 230 VAC primary voltage (230 VAC model is not UL Listed or CSA Certified)
TANK ALERT® I – Easy-to-install liquid level alarm system for indoor use
Part #| Description (120V)| Shipping Weight| List
Price
---|---|---|---
1007457| 101-01H (120 VAC w/15’ SJE SignalMaster® High Level)| 3.58 lbs|
$204.00
1009207| 101-01HSPKT (120 VAC w/15’ SJE SignalMaster® High Level) with
splice kit| 3.58 lbs.| $215.00
1003104| 101-01H (120 VAC w/15’ Sensor Float® High Level)| 3.58 lbs.|
$216.00
1003365| 101-01L (120 VAC w/15’ Sensor Float® Low Level)| 3.58 lbs.|
$216.00
1002235| 101-01X (120 VAC no float)| 2.14 lbs.| $147.00
Part #| Description (230V)| Shipping Weight| List
Price
1008009| 101-02H (230 VAC w/15’ SJE SignalMaster® High Level)| 3.58
lbs.| $284.00
1003364| 101-02H (230 VAC w/15’ Sensor Float® High Level)| 3.58 lbs.|
$297.00
1005420| 101-02L (230 VAC w/15’ Sensor Float® Low Level)| 3.58 lbs.|
$297.00
1005419| 101-02X (230 VAC no float)| 2.14 lbs.| $228.00
H = High Level L = Low Level X = No Float SPKT = Splice Kit MASTER CARTON holds 16 boxed units.
CONTROL SWITCH OPTIONS
The Tank Alert® I alarm system comes standard with a 15 foot SJE SignalMaster® control switch with mounting clamp. Other float switches are available. See control switch section of the catalog. To determine the price of alarm with an alternate float, add the price of the part number with “no float” to the price of the float switch.
SPECIFICATIONS
- VOLTAGE FOR 120 VAC MODEL:
- PRIMARY: 120 VAC, 50/60 Hz, 5 watts max. (alarm condition)
- SECONDARY: 12 VAC
- VOLTAGE FOR 230 VAC MODEL (not UL Listed or CSA Certified):
- PRIMARY: 230 VAC, 50/60 Hz, 5 watts max. (alarm condition)
- SECONDARY: 12 VAC
- ALARM ENCLOSURE: 6 x 4 x 2.5 inch (15.24 x 10.16 x 6.35 cm), NEMA 1 metal
- ALARM HORN: 86 decibels at 10 feet (3 meters)
- POWER CORD: 6 foot (1.8 meter)
- FLOAT SWITCH CONNECTION TERMINAL: For float switch connection only. Do not apply power. (Voltage across terminals is 12 VAC.)
- FLOAT SWITCH: SJE SignalMaster® control switch with mounting clamp
- CABLE: 15 feet (4.57 meters), flexible 18 gauge, 2 conductor (UL) SJOW, water-resistant (CPE)
- FLOAT: 2.74 inch diameter x 4.83 inch long (7 cm x 12.3 cm), high impact, corrosion resistant polypropylene housing for use in sewage and non-potable water up to 140°F (60°C)
- MAXIMUM WATER DEPTH: 30 feet (9 meters), 13 psi
- ELECTRICAL: 5 amps, 125 VAC/250 VAC, 50/60 Hz