SJE RHOMBUS Installer Friendly Series IFS DRIP Irrigation Control Panel Owner’s Manual

August 14, 2024
SJE RHOMBUS

SJE RHOMBUS Installer Friendly Series IFS DRIP Irrigation Control Panel

Specifications

  • Part # 1018134
  • Part # 1021573
  • Part # 1021563
Description Voltage (VAC) FLA (Full Load Amps)
IFS Drip Panel 120/208/240V 7-15
IFS Drip Panel with Pressure Switch 120V 7-15
IFS Drip Panel with Pressure Switch 120/208/240V 7-15

Product Usage Instructions

Panel Layout and Touch Pad Features:
The panel layout may vary with options. The touch pad features include various indicators and buttons for monitoring and controlling the system.

Components

  • Exterior Alarm Test/Normal/Silence Switch
  • Alarm horn (83 to 85 decibel rating)
  • Circuit breaker for pump disconnect and branch circuit protection
  • Circuit board with terminal blocks for float and valve connections
  • Float and valve connections
  • Magnetic motor contactor for pump control
  • Large incoming power/pump connection terminal block
  • Ground lugs

Operation:
The operation of the IFS Drip Control Panel involves four float switches controlling the operation. Timers on the PCB manage pump dosing cycles. When the liquid level activates the timer on float, the following operations occur:

  1. Rest time
  2. The pump turns on and the spin filter valve opens for the user-programmed length of time.
  3. The spin filter valve closes, and the pump continues to run for the user-programmed dose time.
  4. The pump continues to run, and the flush valve opens for the user-programmed length of time.
  5. The pump turns off, and the flush valve remains open for the user-programmed drain time.
  6. The flush valve closes for the user-programmed off time.

The Installer Friendly Series Drip irrigation control panel is designed to control one 120V or 230V single phase pump for subsurface irrigation systems. The IFS Drip panel features a simple, easy-to-use touch pad on the inner door for programming and monitoring system operation: rest for standard time, rest for peak enable time, spin filter flush time, dose time, field flush time, field drain time, and low alarm activation.

TOUCH PAD FEATURES

  • A. Alarm Power indicator/fuse; LED indicator light illuminates if alarm power is present in panel
  • B. Alarm Power replace indicator illuminates if alarm fuse is blown
  • C. Control Power indicator/fuse; LED indicator light illuminates if control power is present in panel
    • NOTE : If control power is not present panel will go into alarm mode.
  • D. HOA (Hand/Off/Automatic) indicators/buttons control pump mode with LED indication
  • E. Float Status indicators illuminate when floats are activated; alarm will activate and indicator will flash if a float operates out of sequence
  • F. Pump Run indicator illuminates when pump is called to run
  • G. Cycle Status indicators allows user to see which cycle (dose, flush, or drain) is activated
  • H. Advance and Pause buttons allow user to cycle though system functions for testing
  • I. Rest Time indicator illuminates in between cycles
  • J. Count indicator illuminates when viewing panel data
  • K. Program indicator illuminates when programming panel
  • L. Flush Valve indicator illuminates when flush valve is called to energize
  • M. Spin Valve indicator illuminates when spin valve is called to energize
  • N. Seven-Segment LED Display for high water alarm count, float status sequence error count, low level cutout float open low alarm count, standard dose count, power-fail count, pump on/off cycle count, pump run times (hh:mm), and peak dose count
  • O. Next, Up, Select Buttons are used to navigate through the display.

NOTE : LED display will turn off after one minute of not being used.

COMPONENTS

  1. Enclosure measures 12 x 10 x 6 inches (30.48 x 24.4 x 15.24) NEMA 4X (ultraviolet stabilized thermoplastic, padlockable with integral mounting flanges, drip shield, (2) heavy duty cover latches, and stainless steel ¼ turn set screw; for outdoor or indoor use)
  2. Red LED beacon provides 360° visual check of alarm condition
  3. Exterior Alarm Test/Normal/Silence Switch allows horn and beacon to be tested and horn to be silenced in an alarm condition; alarm automatically resets once alarm condition is cleared (Not shown)
  4. Alarm horn provides audio warning of alarm condition (83 to 85 decibel rating) (Not shown)
  5. Circuit breaker provides pump disconnect and branch circuit protection
  6. Circuit board provides power to main circuit board and contains terminal blocks for float and valve connections
  7. Float connections
  8. Valve connections
  9. Magnetic motor contactor controls pump by switching electrical lines
  10. Large incoming power/pump connection terminal block
  11. Ground lugs

Note : Options, voltage, and amp range selected may change enclosure size and component layout.
Note : Schematic/Wiring Diagram and Pump Specification Label are located inside the panel.

INSTALLER FRIENDLY SERIES DRIP
Single phase, simplex subsurface touch pad drip irrigation for pump control and system monitoring.

Part # Description VAC                     FLA

1018134| IFS Drip Panel| 120/208/240V| 7-15
1021573| IFS Drip Panel with Pressure Switch| 120V| 7-15
1021563| IFS Drip Panel with Pressure Switch| 120/208/240V| 7-15

IFS Drip Control Panel Operation
Four (4) float switches (low level, timer on/off, peak enable, and high alarm floats) control the operation. Timers internal to the PCB control the pump dosing cycles. When the liquid level activates the timer on float, the following operations occur:

  1. Rest time
  2. The pump turns on and the spin filter valve opens for the user-programmed length of time.
  3. The spin filter valve closes and the pump continues to run for the user-programmed dose time.
  4. The pump continues to run and the flush valve opens for the user-programmed length of time.
  5. The pump turns off and the flush valve remains open for the user-programmed drain time.
  6. The flush valve closes for the user-programmed off time.

California Prop 65 requires the following: WARNING: Cancer and Reproductive Harm  www.P65Warnings.ca.gov

www.sjerhombus.com   email : customer.service@sjeinc.com
SEE PRICE BOOK FOR PRICING

FAQ’s

Q: How do I know if there is an alarm condition?
A: The Alarm Power indicator/fuse LED will illuminate if alarm power is present in the panel, and the Alarm Power replace indicator will illuminate if the alarm fuse is blown.

Q: What happens if control power is not present?
A: If control power is not present, the panel will go into alarm mode.

Q: How can I control the pump mode?
A: Use the HOA (Hand/Off/Automatic) indicators/buttons for controlling the pump mode with LED indication.

Q: How do I navigate through the display?
A: Utilize the Next, Up, Select Buttons to navigate through the display. The LED display will turn off after one minute of not being used.