READ AND SAVE THESE INSTRUCTIONS

WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:

  1. Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer at the address or telephone number listed in the warranty.

  2. Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.

  3. Installation work and electrical wiring must be done by a qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction codes and standards.

  4. Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent back drafting.
    Follow the heating equipment manufacturer’s  guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities.

  5. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.

  6. Ducted fans must always be vented to the outdoors.

  7. Acceptable for use over a tub or shower when connected to a GFCI (Ground Fault Circuit Interrupter) – protected branch circuit (ceiling installation only).

  8. This unit must be grounded.

  9. Do not use this fan with any solid-state speed control device.

  10. Do not use replacement parts that have not been recommended by Broan NuTone LLC.

  11. If the fan makes excessive noise or if there is unusual noise or smells of smoke. Disconnect power supply and contact customer service.

  12. The wearing of safety glasses and gloves is recommended when installing, maintaining or cleaning the unit to reduce the risk of injury that could be caused by the presence of thin metal and/or moving parts.

For Warranty Statement, Service Parts, Technical Support, or to Register your product, please visit our website or call:
In the United States – Broan-NuTone.com 800-558-1711.
In Canada – Broan-NuTone.ca 800-567-3855.

CAUTION

  1. For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapours.
  2. Install the fan at least 8 feet (2.4 m) above the floor.
  3. To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall spray, construction dust, etc. off power unit.
  4. Please read specification label on product for further information and requirements.

CLEANING & MAINTENANCE

TO CLEAN THE GRILLE: Remove the grille and grille trim. Plastic parts can be cleaned with mild detergent, such as dishwashing liquid. Dry with a soft cloth. DO NOT USE ABRASIVE CLOTH, STEEL WOOL PADS OR SCOURING POWDERS.

TO CLEAN INTERIOR OF THE UNIT: Once the grille and grille trim are removed, gently vacuum interior of the unit with the dusting brush attachment.

The motor is permanently lubricated and never needs oiling. If the motor bearings are making excessive or unusual noises, replace the blower assembly (includes motor and impeller).

OPERATION

Use an on/off switch to operate the fan.
Refer to Broan’s catalog for a complete line of accessories/controls to effectively adapt these fans to your requirements.

IMPORTANT – The ducting from this fan to the outside of the building has a strong effect on the air flow, noise and energy use of the fan. Use the shortest, straightest duct routing possible for best performance, and avoid installing the fan with smaller ducts than recommended. Insulation around the ducts can reduce energy loss and inhibit mild growth. Fans installed with existing ducts may not achieve their rated airflow.

OPTION – To mount housing anywhere between ceiling framing: Use optional Hanger Bar Kit (sold separately from local distributors or website). Follow mounting instructions included with kit.

Scan this QR code for Installation video.

Remove from packaging. Remove blower assembly and wiring panel.

Mount housing.

Choose one option to mount housing to ceiling structure:

**New Construction

**

Other options:

  • Hanger bars (sold separately Model Number MHB4)
  • Flange Install (see Installation video)

Retrofit

Note: If you are installing retrofit, bend the ears in and use the mask from packaging to cut opening to correct size (if needed).

Angled Screw Holes

Choose one option to attach duct connector.

New Construction
Install duct connector (use screw from parts bag and ensure tabs engage in housing), then attach new construction duct work with foil tape.

Retrofit
Pull duct work into housing and attach to duct connector with foil tape, then install duct connector (use screw from parts bag and ensure tabs engage in housing).

Pro Tip : First and last 18″ of the ducting should be rigid or stretched straight for expected performance.

Connect wiring.

Scan this QR code for helpful hints.

Attach wire enclosure by tab and screw.

Re-install wiring panel and secure with screw from parts bag.

Install the blower assembly with provided screws. Plug in blower.

Note : For new construction, use mask to protect blower until ceiling is finished.

Install the grille trim with screws from parts bag.

Install the grille by sliding clips into grille trim.